• 제목/요약/키워드: National monitoring

검색결과 7,930건 처리시간 0.042초

인후두 역류환자에서 이동성 24시간 이중 탐침 산도 검사와 인후두 역류 소견 점수와의 상관관계 (Relationship between Ambulatory 24-hour Double Probe pH Monitoring and Reflux Finding Score in Patients with LPR)

  • 박영대;강대운;이진춘;이병주;왕수건;김광하
    • 대한후두음성언어의학회지
    • /
    • 제19권2호
    • /
    • pp.136-141
    • /
    • 2008
  • Background and Objectives: Laryngopharyngeal reflux (LPR) is a very common disease among outpatients of department of otorhinolaryngology. Although there are several diagnostic tools for LPR disease and ambulatory 24-hour double-probe pH monitoring is gold standard method, empirical diagnosis by reflux symptom index and reflux finding score (RFS) are mainly used. So we analyzed the relationship between ambulatory 24-hour double-probe pH monitoring and RFS in patients with LPR. Subjective and Method: Fifty patients with LPR symptoms and abnormal RFS and ambulatory 24-hour double probe monitoring were enrolled. Each items and sum of laryngeal reflux score were compared the results of ambulatory 24-hour double-probe pH monitoring in upper (UES) and lower (LES) esophageal sphincter. Results: There were no significant correlation between the results of ambulatory 24-hour double-probe pH monitoring in UES (pH<4 and pH<5) and each item and sum of RFS. However, supine time and reflux number of UES (pH<5) were showed the partial correlations with diffuse laryngeal edema and thick endolaryngeal mucus (p=0.03, p=0.01). Although there were no relationship between the results of ambulatory 24-hour double-probe pH monitoring in LES and sum of RFS, the significant correlations presented between granuloma and total time (p=0.008), upright time (p=0.008, reflux number (p=0.049) of LES. Conclusion: Although granuloma among items of RFS showed significantly correlation with the results of ambulatory 24-hour double-probe pH monitoring in LES, there were no significant correlation between the results of ambulatory 24-hour double-probe pH monitoring in UES and LES and items and sum of RFS.

  • PDF

Development of Multiple CMP Monitoring System for Consumable Designs

  • Park, Sun-Joon;Park, Boum-Young;Kim, Sung-Ryul;Jeong, Hae-Do;Kim, Hyoung-Jae
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권1호
    • /
    • pp.11-14
    • /
    • 2007
  • Consumables used in Chemical Mechanical Polishing (CMP) have been played important role to improve quality and productivity. Since the properties of consumables constantly change with various reasons, such as shelf time, manufactured time, lot to lot variation from supplier and so on, CMP results are not constant during the process. Also, CMP process results are affected by multiple sources from wafer, conditioner, pad and slurry. Therefore, multiple sensing systems are required to monitor CMP process variation. In this paper, the authors focus on development of monitoring system for CMP process which consist of force, temperature and displacement sensor to measure the signal from CMP process. With monitoring systems mentioned above, complex CMP phenomena can be investigated more clearly.

Remote Monitoring of Abrupt Overflowing in Common Utility Duct Using Reflective Side-Polished Optical Fiber Submersion Sensor

  • Lee, Cherl-Hee;Kim, Cheol;Kang, Shin-Won;Song, Jae-Won
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.166-169
    • /
    • 2008
  • The submersion monitoring system based on a reflective side-polished optical fiber submersion sensor with an optical fiber mirror was shown to be an effective alarm system with remote monitoringwhen the drainage capacity of a common utility duct is exceeded due to heavy rainfall. The proposed sensor was connected to an existing installed optical fiber network at a height of 250mm in a common utility duct, and then tested under sample materials(distilled water, river water, sea water, foul water, muddy water, petroleum, edible oil) at a distance of 1km from the sensor for remote sensing. In experiments, the proposed real-time sensor system reduced maintenance cost and improved monitoring efficiency by using a reflection-type side-polished optical fiber submersion sensor efficient for remote monitoring of a common utility duct.

Runtime Software Monitoring Based on Binary Code Translation for Real-Time Software

  • Choi, Kiho;Kim, Seongseop;Park, Daejin;Cho, Jeonghun
    • Journal of Information Processing Systems
    • /
    • 제15권6호
    • /
    • pp.1462-1471
    • /
    • 2019
  • Real-time embedded systems have become pervasive in general industry. They also began to be applied in such domains as avionics, automotive, aerospace, healthcare, and industrial Internet. However, the system failure of such domains could result in catastrophic consequences. Runtime software testing is required in such domains that demands very high accuracy. Traditional runtime software testing based on handwork is very inefficient and time consuming. Hence, test automation methodologies in runtime is demanding. In this paper, we introduce a software testing system that translates a real-time software into a monitorable real-time software. The monitorable real-time software means the software provides the monitoring information in runtime. The monitoring target are time constraints of the input real-time software. We anticipate that our system lessens the burden of runtime software testing.

이동 로봇 섀시 누전 모니터링 센서 개발 (Development of Leakage Current Sensor for Mobile Robot Chassis)

  • 김청월;권익현;김성득;이영태
    • 반도체디스플레이기술학회지
    • /
    • 제17권3호
    • /
    • pp.104-107
    • /
    • 2018
  • In this paper, we developed a sensor for monitoring the leakage current through the chassis of the robot. The leakage current sensor needs to be developed because it is a necessary part to prevent electric shock accidents that may occur through the chassis of a robot or an electric vehicle. This leakage monitoring sensor was developed to be mounted directly on the chassis of the robot. This sensor protects the control system from noise by discharging static and high-frequency noise that may occur in the chassis of the robot and monitors the leakage current by measuring the amount of current discharged through the ground. In this paper, a leakage monitoring sensor was developed with a simple structure using resistors, capacitors and OP-AMP, and the performance was evaluated.

흡수분광법을 적용한 시안화이온의 연속 모니터링 장치 구성 및 적용 (A Continuous Monitoring System for the Determination of Cyanide Ions Using Nickel Complexation Reaction)

  • 김경민;이상학;김영호;김규만;오상협
    • 응용화학
    • /
    • 제16권1호
    • /
    • pp.25-28
    • /
    • 2012
  • A determination method of cyanide ion (CN-) using nickel complexation reaction by continuous monitoring system. The mechanical parameters and chemical conditions of the complexation reaction were investigated prior to application of continuous monitoring system for determination of cyanide. On the optimized conditions, the calibration curve was linear over the range from 5.0×10-6 to 1.0×10-4 M. In this range, 2.40% of the reproducibility (RSD, n=3) was obtained. The limit of detection (3σ/s) was calculated to be 1.8×10-6 M.

지하수 중 다환방향족탄화수소류(PAHs, Polycyclic Aromatic Hydrocarbons)의 동시분석법 마련 및 수질실태조사 (Preparation of Simultaneous Analysis Method of PAHs (Polycyclic Aromatic Hydrocarbons) and Monitoring PAHs in Groundwater)

  • 김덕현;박선화;윤종현;최효정;김문수;정도환;김영;김현구
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권4호
    • /
    • pp.67-76
    • /
    • 2020
  • Polycyclic aromatic hydrocarbons (PAHs) are organic compounds that tend to persist in environmental media for a long period of time. This work presents a 2-year monitoring study of occurrence of three PAHs (benzo(a)pyrene, naphthalene, and fluoranthene) in groundwater. The groundwater samples were collected from 106 sites of nation's groundwater quality monitoring network and analyzed by simultaneous analysis method to quantify the concentrations of the PAHs. Benzo(a)pyrene was not detected in all samples. Naphthalene and fluoranthene concentrations ranged from not detected to 12.8 ng/L and not detected to 10.5 ng/L with their detection frequency being 57.8 and 4.2%, respectively. The concentrations of PAHs in ground- and drinking waters are not currently regulated in Korea, but the concentration levels of naphthalene and fluoranthene found in this work were lower than the regulatory limits of other countries (naphthalene 0.001~0.07 mg/L, fluoranthene 0.001~1.4 mg/L). The monitoring result of this study revealed that PAHs exist as trace amounts in domestic groundwater, however continuos monitoring is necessary to protect groundwater from PAHs contamination with growing industrialization and urbanization.

Intraoperative Nerve Monitoring during Minimally Invasive Esophagectomy and 3-Field Lymphadenectomy: Safety, Efficacy, and Feasibility

  • Srinivas Kodaganur Gopinath;Sabita Jiwnani;Parthiban Valiyuthan;Swapnil Parab;Devayani Niyogi;Virendrakumar Tiwari;C. S. Pramesh
    • Journal of Chest Surgery
    • /
    • 제56권5호
    • /
    • pp.336-345
    • /
    • 2023
  • Background: The objective of this study was to demonstrate the safety, efficacy, and feasibility of intraoperative monitoring of the recurrent laryngeal nerves during thoracoscopic and robotic 3-field esophagectomy. Methods: This retrospective analysis details our initial experience using intraoperative nerve monitoring (IONM) during minimally invasive 3-field esophagectomy. Data were obtained from a prospectively maintained database and electronic medical records. The study included all patients who underwent minimally invasive (video-assisted thoracic surgery/robotic) transthoracic esophagectomy with neck anastomosis. The patients were divided into those who underwent IONM during the study period and a historical cohort who underwent 3-field esophagectomy without IONM at the same institution. Appropriate statistical tests were used to compare the 2 groups. Results: Twenty-four patients underwent nerve monitoring during minimally invasive 3-field esophagectomy. Of these, 15 patients underwent thoraco-laparoscopic operation, while 9 received a robot-assisted procedure. In the immediate postoperative period, 8 of 24 patients (33.3%) experienced vocal cord paralysis. Relative to a historical cohort from the same institution, who were treated with surgery without nerve monitoring in the preceding 5 years, a 26% reduction was observed in the nerve paralysis rate (p=0.08). On follow-up, 6 of the 8 patients with vocal cord paralysis reported a return to normal vocal function. Additionally, patients who underwent IONM exhibited a higher nodal yield and a decreased frequency of tracheostomy and bronchoscopy. Conclusion: The use of IONM during minimally invasive 3-field esophagectomy is safe and feasible. This technique has the potential to decrease the incidence of recurrent nerve palsy and increase nodal yield.

무인모니터링 시스템을 활용한 논습지에 도래하는 조류 개체군 동태 연구 (Study of Population Dynamics of Birds Using Unmanned Monitoring System in Rice Paddy)

  • 남형규;김명현;권순익;어진우;송영주
    • 한국습지학회지
    • /
    • 제20권2호
    • /
    • pp.124-130
    • /
    • 2018
  • 본 연구는 무인모니터링 시스템을 활용하여 논에 도래하는 조류의 현황과 개체군 변동 특성을 확인하기 위해 수행되었다. 무인모니터링 시스템을 이용한 조사와 전문가에 의한 현장 조사를 비교하여 개체군 변동 특성의 유사성을 파악하였고, 무인모니터링 시스템 조사를 통해 확인된 조류의 개체군 변동을 시공간적으로 평가하였다. 무인모니터링 시스템을 활용한 조사는 철원, 당진, 부안, 해남 4곳에서 2014년 1월 1일부터 2016년 12월 31일까지 06:00부터 20:00까지 14시간 동안 10분 단위로 촬영하였다. 전문가에 의한 현장 조사는 2016년 1월부터 12월까지 당진에서 월 1회 수행되었다. 무인모니터링 시스템을 활용하여 조사기간 동안 한 대의 무인모니터링 시스템에서 총 91,980장의 이미지를 획득하였다. 획득한 이미지 자료를 분석하여 백로류, 도요물떼새류, 오리기러기류의 동정 및 개체군 변동을 확인하였다. 무인모니터링 시스템과 현장 조사를 비교해보면 수조류 군집 변동 패턴이 현장 조사 결과와 유사한 것을 확인 할 수 있었다. 특히 백로류의 개체군 변동의 유사성이 가장 높게 나타났다. 무인모니터링 시스템을 이용하여 지역별 백로류의 개체군 변동 특성을 확인한 결과 지역에 따라 개체군 변동 특성이 다르게 나타나는 것을 확인할 수 있었다. 또한 무인모니터링 시스템은 월 단위, 일 단위, 분 단위와 같이 다양한 시간 스케일에서 개체군 변동 특성을 확인 할 수 있는 장점을 가지는 것으로 나타났다. 무인모니터링 시스템을 이용한 장기적인 자료 축적은 논습지를 활용하는 수조류 군집의 세부적인 장기변동 특성뿐만 아니라 미래 예측에도 유용하게 이용될 것으로 기대된다.

초등학교 학교급식 학부모 식재료 검수 및 모니터링 활동에 대한 실태조사 (The Survey of Materials Receiving and Monitoring of Parents in Primary School Food Service)

  • 김명희;윤경옥
    • 한국지역사회생활과학회지
    • /
    • 제18권2호
    • /
    • pp.313-321
    • /
    • 2007
  • The study examined the level of understanding and satisfaction of parents who should receive the food materials and monitor the food service, and would provided the basic data for more desirable school feeding system. The analysis was based on the participation level in materials receiving and food service monitoring, condition of equipment, knowledge about materials and the opinions about monitoring education. 160 monitors out of Daejeon primary schools were used and 60% of them were in the age of thirties and the others were in forties. Equipment condition for material receiving was good and most of the monitors were familiar with the ways of using the machines. Difficulties of material receiving were found in meat(65.6%) and sea food(21.9%), and the ratios of activities and the intention to participate in monitoring education were high with 25.0% and 72.5% respectively. Most of the monitors thought sanitary conditions of food materials(100.0%) and delivery persons(96.9%) were very good or good. And 90% of the respondents changed their perception of school food service positive after monitoring. In conclusion, most of the parents wanted to participate in the monitoring and material receiving actively and showed great willingness to receive monitoring education.

  • PDF