• Title/Summary/Keyword: National grid system

Search Result 986, Processing Time 0.03 seconds

Grid Voltage Regulation with MMC-HVDC System

  • Quach, Ngoc-Thinh;Jeong, Woo-Cheol;Yang, Hang-Jun;Choi, Jong-Yun;Kim, Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.146-147
    • /
    • 2014
  • This paper presents an operation of the modular multilevel converter-high voltage direct current (MMC-HVDC) system as a Statcom to support the grid voltage. The advantage of the MMC-HVDC system is that it can control the active and reactive powers independently. The proposed control scheme will be designed by combining this performance and the control method of the Statcom. The grid voltage is regulated by the control of the reactive power, meanwhile the active power is controlled according to its applications. The simulation results based on the PSCAD/EMTDC simulation program will evaluate the effectiveness of the control scheme.

  • PDF

Establishment of Cyber Security Countermeasures amenable to the Structure of Power Monitoring & Control Systems (전력계통 제어시스템 구조에 따른 사이버 보안대책 수립)

  • Woo, Pil Sung;Kim, Balho H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1577-1586
    • /
    • 2018
  • The emergence of the Smart Grid is an integrated solution for the next generation power system that combines IT technology in the power system to create optimal energy utilization and various services. However, these convergence technologies (power systems and information communications) are not only improving the related technologies but also producing various problems especially exposure to cyber risk. In particular, the intelligent power grid has security vulnerabilities through real-time information sharing among various organically linked systems, and it is more complicated than the cyber risk problem in the existing IT field and is directly connected to national disaster accidents. Therefore, in order to construct and operate a more stable smart grid, this paper analyzes the system of power system control system in Korea, and proposes a cyber security element definition and a countermeasure establishment method of power monitoring & control systems based on security standards of smart grid (No. SPS-SGSF-121-1-1).

Seamless Transfer Operation Between Grid-connected and Stand-Alone Mode in the Three-phase Inverter (3상 인버터의 계통연계 및 독립운전모드 전환 연구)

  • Lee, Wujong;Jo, Hyunsik;Lee, Hak Ju;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.201-207
    • /
    • 2013
  • This paper propose seamless transfer operation between grid-connected and stand-alone mode in the three-phase inverter for microgrid. The inverter operates grid-connected mode and stand-alone mode. Grid-connected mode is the inverter connected to grid and stand-alone mode is to deliver energy to the load from inverter at grid fault. When conversion from gird-connected to stand-alone mode, the inverter changes current control to voltage control. When grid restored, the inverter system is conversion from stand-alone to grid-connected mode. In this case, load phase and grid phase are different. Therefore, synchronization is essential. Thus Seamless transfer operation stand-alone to grid-connected mode. In this paper, propose sealmless transfer operation between grid-connceted and stand-alome mode, and this method is verified through simulation and experiment.

A Plan for Construction of the National Electrical Safety Grid to Prevent the Fires Caused by Electrical Faults (전기화재 예방을 위한 국가전기안전망 구축 방안)

  • Bae, Seok-Myeong;Jeon, Jeong-Chay;Park, Chan-Eom;Bae, Seok-Myeong;Ko, Won-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2267-2273
    • /
    • 2009
  • In this paper, in order to monitor and manage an electrical risk factor like as leakage current, load current, and arc-fault, a real time monitoring and management system being operated in the ubiquitous environment was developed, and a plan of construction of an electrical safety grid using the system was proposed. For confirmation of usefulness and reliability of the proposed safety system and grid, the developed intelligent panels were applied to 28 Korean traditional houses in Jeonjoo city, and the grid including the panels was operated. If the proposed National Electrical Safety Grid is completely constructed in the houses of general electrical users, the Grid will have an effect on that a main manager on electrical safety transfers from management system by general people to real-time management system by expert. As a result, the electrical fires caused by an over-load, an arc-fault, and an earth-fault will be prevented.

Independent Generation System Design for the Economic Management of Electrical Charging Stations (전기충전소의 경제적 운영을 위한 독립발전 시스템 설계)

  • Seo, Jin-Gyu;Kim, Kyu-Ho;Rhee, Sang-Bong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.222-227
    • /
    • 2015
  • This paper presents the optimal energy generation systems for economical EVs(Electric Vehicles) charging stations located in an island area. The system includes grid electricity, diesel generator and renewable energy sources of wind turbines and PV(Photovoltaic) panels. The independent generation system is designed with data resources such as annual average wind speed, solar radiation and the grid electricity price by calculating system cost under different structures. This sensitive analysis on the varying data resources allows for the configuration of the most economical generation system for charging stations by comparing initial capital, operating cost, NPC(Net Present Cost) and COE(Cost of Energy). Depending on the increase of the grid cost, the NPC variation of the most economical system which includes renewable energy generations and grid electricity can be smaller than those of other generation systems.

A Cognitive Radio based for Smart Grid AMI Network using Adaptive Algorithm

  • Thapa, Prakash;Acharya, Shree Krishna;Paik, Jong-Gil;Choi, Sang-Gil;Jun, Hae-Ji;Kim, Seong-Whan;Lee, Seong Ro;Lee, Yeonwoo
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.8 no.3
    • /
    • pp.69-77
    • /
    • 2016
  • Maximum utilization of unused license spectrum is one of key factor in cognitive radio network which can handle the large number of systems and devices connected on smart grid AMI network. The central intelligence control system has responsibility to accept new technologies and users for automation. To ensure a reliable communication in smart grid system through cognitive network, a minimum mean square error (MSE) signal using unused licensed spectrum (or frequency) is necessary to be detected with small decision error. In this paper, we introduce a user control wireless smart grid system with minimum MSE using LMS algorithm.

AN ACCURATE AND EFFICIENT CALCULATION OF HIGH ENTHALPY FLOWS USING A HIGH ORDER NEW LIMITING PROCESS

  • Noh, Sung-Jun;Lee, Kyung-Rock;Park, Jung-Ho;Kim, Kyu-Hong
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.15 no.1
    • /
    • pp.67-82
    • /
    • 2011
  • Calculation of accurate wall heat flux for high enthalpy flows requires a dense grid system, which leads to significantly large computational time. A high-order scheme can improve the efficiency of calculation because wall heat flux can be obtained accurately even with a relatively coarse grid system. However, conventional high order schemes have some drawbacks such as oscillations near a discontinuity and instability in multi-dimensional problem. To resolve these problems, enhanced Multi-dimensional Limiting Process(e-MLP) was applied as a high-order scheme. It could provide robust and accurate solutions with high order accuracy in calculation of high enthalpy flows within a short time. We could confirm the efficiency of the high order e-MLP scheme through grid convergence tests with different grid densities in a hypersonic blunt nose problem.

Grid Voltage Estimation Scheme without Phase Delay in Voltage-sensorless Control of a Grid-connected Inverter (전압센서를 사용하지 않는 계통연계 인버터의 제어 및 위상지연을 개선한 계통전압 추정 기법)

  • Kim, Hyun-Sou;Kim, Kyeong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.1
    • /
    • pp.89-93
    • /
    • 2017
  • This study proposes a grid voltage estimation scheme without a phase delay in the voltage-sensorless control of a grid-connected inverter to enhance its economic feasibility, such as manufacturing cost and system complexity. The proposed scheme estimates grid voltages using a disturbance observer (DOB)-based current controller to control the grid-connected inverter without grid-side voltage sensors. The proposed voltage-sensorless control scheme can be applied successfully to grid-connected inverters, which should be operated with synchronization to the grid, considering the phase angle of the grid can be effectively detected through estimating the grid voltages by DOB. However, a problem associated with the phase delay in estimated grid voltages remains because the DOB has dynamic behavior similar to low-pass filter. Hence, the estimated grid voltages are compensated by a phase lead compensator to overcome the limitation. The effectiveness of the proposed control and estimation schemes is proven through simulations and experiments using a 2 kVA prototype inverter.

Proposed measure for Smart Grid's Personal Information Security Issue (스마트 그리드 개인정보 보안이슈 방안 제시)

  • Choi, Heesik;Cho, Yanghyun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.4
    • /
    • pp.41-49
    • /
    • 2016
  • Smart Grid is a next generation of new power growth electrical grid which provide high quality of electrical service by using Information Technologies to increase intelligence and performance. By using Smart Grid system, it can support energy management such as increase quality of electrical power, decrease energy and decrease emissions. However, Smart Grid uses information of energy consumption and when Smart Grid collects information, it will create private information. In this thesis, it will address issues of security private information which caused by Smart Grid for administrative measure and efficiency of Smart Grid in domestic. Also, cryptographic module algorithm, latest security solutions and strong wireless security policy for network environment such as wireless communication Iinternet are require for Smart Grid perform successfully and protect national power network equipment from cyber-attack and can stop leakage of user's personal information. Finally, it is urgent to prepare protection measures of National industrial facilities and power grid which can prepare for a cyber terrorism and penetration attacks and build emergency countermeasure management team for Smart Grid are require for safe Smart Grid environment.

An Orthologous Group Clustering Technique based on the Grid Computing

  • Oh, J.S.;Kim, T.K.;Kim, S.S.;Kwon, H.R.;Kim, Y.C.;Yoo, J.S.;Cho, W.S.
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2005.09a
    • /
    • pp.72-77
    • /
    • 2005
  • Orthologs are genes having the same function across different species that specialize from a single gene in the last common ancestor of these species. Orthologous groups are useful in the genome annotation, studies on gene evolution, and comparative genomics. However, the construction of an orthologous group is difficult to automate and it takes so much time. It is also hard to guarantee the accuracy of the constructed orthologous groups. We propose a system to construct orthologous groups on many genomes automatically and rapidly. We utilize the grid computing to reduce the sequence alignment time, and we use clustering algorithm in the application of database to automate whole processes. We have generated orthologous groups for 20 complete prokaryotes genomes just in a day because of the grid computing. Furthermore, new genomes can be accommodated easily by the clustering algorithm and grid computing. We compared the generated orthologous groups with COGs (Clusters of orthologous Group of proteins) and KO (KEGG Ortholog). The comparison shows about 85 percent similarity compared with previous well-known orthologous databases.

  • PDF