• Title/Summary/Keyword: National Isolation Unit

Search Result 60, Processing Time 0.025 seconds

Isolation Effectiveness by Progressive Space Organization in Negative Pressured Isolation Unit (음압격리병실에 있어서 단계별 공간구성의 격리효과)

  • Kwon, Soonjung;Sung, Minki
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.4
    • /
    • pp.79-86
    • /
    • 2016
  • Purpose: The purpose of this study is to identify the effect of Progressive Space Organization (ante-rooms) in Negative Pressured Isolation Unit(NPIU) such as National and Regional Isolation Units in Korea in order to build basic data for the evidence based design of Airborne Infection Isolation Units which should prepare and respond effectively to the public health crisis due to the hazardous airborne infectious disease. Methods: 1) Gas(SF6) test and analysis on the 23 Korean Isolation Units under operation. 2) Assessment of the isolation level of the space components by checking the Gas concentration. 3) Analysis of the Isolation Effectiveness according to Space Organizational levels. Results: 1) The higher segregation level is, the lower Gas(SF6) concentration is. 2) Too many segregations(anterooms) of Isolation Unit are not efficient for the prevention of infectious bacillus spread. For example, 4 level of segregation has similar segregation effect to the 3 level of segregation. Implications: Many anterooms in front of the isolated patient bedroom will guarantee the safe environment against the danger of hazardous airborne nosocomial infection. On the other hand, too many segregations is inefficient, expensive, inconvenient, narrow(unflexible) and so on. This study can be used as basic data for further development of design guidelines of isolation units.

Ethnography on Isolation Unit for Hematopoietic Stem Cell Transplantation: Focusing on Patients (조혈모세포이식 병동에 관한 문화기술지: 환자를 중심으로)

  • Kang, Young-Ah;Yi, Myung-Sun
    • Asian Oncology Nursing
    • /
    • v.9 no.1
    • /
    • pp.31-42
    • /
    • 2009
  • Purpose: The purpose of the study was to understand how patients experience everyday life in an isolation unit for hematopoietic stem cell transplantation (HSCT). Method: The data were collected from 25 patients with HSCT at the isolation unit from January to March in 2008 in one general hospital in Korea. The data were collected by participant observations and ethnographic interviews and were analyzed using ethnographic method. Results: Four themes regarding environmental area emerged: 'barrier pulling up the drawbridge', 'very strange world', 'small and restricted space tied by IV and other treatment lines', and 'loud noise in a silent space.' Three themes regarding patients emerged: 'facing fear and anxiety', 'continuation of loneliness and lethargy', and 'compromising with a very long, dull, and boring time'. These themes describe how patients with HSCT suffer from continuous physical and psychosocial problems in a confined space, while endeavoring to control these problems and to search for hope for a new life. Conclusion: The results of the study provide an in-depth understanding of the experience and culture of patients in an isolation unit for HSCT. They would be used in developing practical programs to decrease patient's culture shock including fear and anxiety at isolation unit for HSCT.

  • PDF

A Study on the Area Composition Analysis of the National Designated Isolation Unit Wards(NDIUs) - Focused on the NDIU wards issued in 2016 (국가지정입원격리병상의 시설별 면적구성에 관한 연구 - 2016년 국가지정입원격리병상 확충사업대상을 중심으로)

  • Yoon, Hyung Jin;Kwon, Soon Jung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.2
    • /
    • pp.73-82
    • /
    • 2017
  • Purpose: Since the facility guidelines for National Designated Isolation Unit wards(NDIUs) had been edited since 2016, all hospital who want to expand or install NDIU should adapt the new guidelines. Instead of providing area requirement, by the way, only essential or optional facility requirements are suggested except patient bedroom in the guidelines. So, as analyze area and area composition of the NDIUs, it could be expected that this study has a role as an area planing reference for not only NDIU but also another airborne infection isolation room. Methods: For the area analysis, 18 sample hospitals are selected among 2016 year applicants. All rooms in NDIUs are grouped as zones whether those are negative air pressurized or not and programed room or not. At the end, area of the zones are summarized and analysed a relationship between area increase and bed number by both correlation analysis and regression analysis. In addition, department usable and gross area per bed, N/G ratio, G/N ratio, and average area ratio of each zone is calculated. Results: First of all, rooms in none negative air pressurized zone of the NDIUs haven't shown a regular installation so that only those in negative air pressurized zone are targeted for the area analysis. Second of all, patient room unit(0.92) and support area(0.79), by correlation analysis, are correlated with total net area. Patient room unit(0.94) and total net area(0.79) are also shown a correlation with bed number. Department usable area($R^2=0.63$, y=36.278x + 102) and patient room unit area($R^2=0.89$, y= 27.993x - 0.8924) has a relationship with bed number by regression analysis. Average N/G is shown as 0.85 and G/N 1.36. Average area ratio of circulation, doffing area, patient room unit, and support area are 25.4%, 9.1%, 50.9%, and 14.6% in order. Implications: This study is a basic research for exploring the NDIUs guidelines to find resonable evidence to develop it for its practical use. Still, it is possibly expected that the guideline is to be developed by post occupancy evaluation in the area of where minimum requirement or facility grade needs to be defined, and by further studies with various perspectives.

Effect of the Management of Infection for Methicillin Resistant Staphylococcus aureus at an Neurosurgical Intensive Care Unit (신경외과중환자실 내에서 MRSA 감염관리 효과)

  • Kim, Yun-Kyung;Lee, Ji-Min;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.11 no.2
    • /
    • pp.114-119
    • /
    • 2009
  • Purpose: The effectiveness of an infection control program is important to hospital quality improvement and decreases of mortality rate and prevalence. Methicillin resistant Staphylococcus aureus (MRSA) is the most common pathogen causing nosocomial infection. The aim of the study was to identify the most important risk factors for acquiring an MRSA, to evaluate the MRSA incidence rates after the nursing intervention in Neurosurgery intensive care unit (ICU). Methods: Clinical data were collected prospectively from December 2008 until July 2009 in Neurosurgery ICU. The patients were divided into preintervention and postintervention groups. An infection was defined as an MRSA if it occurred 48 hr after admission to the Unit. Infection control program including hand washing, education of health care workers about MRSA, standard precaution and contact isolation of patients were applied for three month. Results: A total of 85 patients were included in the study. Forty-five patients of S. aurerus were detected. Among 45 of S. aurerus, MRSA were isolated from 38 patients. The incidence MRSA rate of postintervention group was 26.9% while incidence MRSA rate of preintervention group was 66.7%. In total, The incidence MRSA rate was 44.7%. The incidence of MRSA have decreased in the postintervention as compared with the preintervention group. Conclusion: The infection control program for MRSA was effective to decrease the MRSA isolation rate. The health care workers regular hand washing, education of nosocomial infection control is important enough to be emphasized.

  • PDF

Methodology of seismic-response-correlation-coefficient calculation for seismic probabilistic safety assessment of multi-unit nuclear power plants

  • Eem, Seunghyun;Choi, In-Kil;Yang, Beomjoo;Kwag, Shinyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.967-973
    • /
    • 2021
  • In 2011, an earthquake and subsequent tsunami hit the Fukushima Daiichi Nuclear Power Plant, causing simultaneous accidents in several reactors. This accident shows us that if there are several reactors on site, the seismic risk to multiple units is important to consider, in addition to that to single units in isolation. When a seismic event occurs, a seismic-failure correlation exists between the nuclear power plant's structures, systems, and components (SSCs) due to their seismic-response and seismic-capacity correlations. Therefore, it is necessary to evaluate the multi-unit seismic risk by considering the SSCs' seismic-failure-correlation effect. In this study, a methodology is proposed to obtain the seismic-response-correlation coefficient between SSCs to calculate the risk to multi-unit facilities. This coefficient is calculated from a probabilistic multi-unit seismic-response analysis. The seismic-response and seismic-failure-correlation coefficients of the emergency diesel generators installed within the units are successfully derived via the proposed method. In addition, the distribution of the seismic-response-correlation coefficient was observed as a function of the distance between SSCs of various dynamic characteristics. It is demonstrated that the proposed methodology can reasonably derive the seismic-response-correlation coefficient between SSCs, which is the input data for multi-unit seismic probabilistic safety assessment.

Studies on the Isolation and Identification of Xylanase and Mannanase Producing Aspergillus niger (Xylanase와 Mannanase를 생산하는 Aspergillus niger의 분리와 동정에 관한 연구)

  • Kim, Byoung-Suk;Cho, Jin-Kook;Song, Jin-Ook;Lee, Hak-Kyo;Hwang, Seong-Gu
    • Journal of Animal Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.427-432
    • /
    • 2009
  • This study was undertaken to screen a high xylanase and mannanase producing microbes. In the first experiment, screening was undertaken against 50 samples of microorganisms having xylanase and mannanase activities from soil and fallen leaves. The screening process has focused on picking out fungi having high xylanase and mannanase activities under the solid-state fermentation. The xylanase and mannanase activities of 6 screened microbes were 0.9~1.6 unit/mL and 0.2~0.4 unit/mL, respectively, under the submerged fermentation condition. However, under the solid-state fermentation, xylanase and mannanase activities were 103.7~220.0 unit/g and 20.1~40.3 unit/g, respectively. Finally one microbe (E-3) was selected and its xylanase and mannanase activities were 197.3 unit/g and 39.9 unit/g, respectively. The morphological and molecular biological classification of E-3 showed 99% homology with the Aspergillus niger.

National Level Response to Pandemic (H1N1) 2009 (정부의 신종인플루엔자 A(H1N1) 대응)

  • Lee, Dong-Han;Shin, Sang-Sook;Jun, Byung-Yool;Lee, Jong-Koo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.2
    • /
    • pp.99-104
    • /
    • 2010
  • The World Health Organization (WHO) announced the emergence of a novel influenza on April 24, 2009, and they declared pandemic on June 11. In Korea, the proportion of influenza-like illness and the consumption of antiviral agents peaked in early November. The government established the Central Headquarters for Influenza Control and operated the emergency response system. In the quarantine stations, we checked the body temperature and collected quarantine questionnaires from all the arrivals from infected countries. We also isolated the confirmed cases in the national isolation hospitals. However, as the community outbreaks were reported, we changed strategy from containment to mitigation. We changed the antiviral agent prescription guideline so that doctors could prescribe antiviral agents to all patients with acute febrile respiratory illness, without a laboratory diagnosis. Also the 470 designated hospitals were activated to enhance the efficacy of treatment. We vaccinated about 12 million people and manage the adverse event following the immunization management system. In 2010, we will establish additional national isolation wards and support hospitals to establish fever clinics and isolation intensive care unit (ICU) beds. We will also make a computer program for managing the national isolation hospitals and designated hospitals. We will establish isolation rooms and expand the laboratory in quarantine stations and we will construct a bio-safety level 3 laboratory in each province. In addition, we plan to construct a bio-safety level 4 laboratory at a new Korea Centers for Disease Control and Prevention (KCDC) facilities in Ossong.

Knowledge and Practice of Middle East Respiratory Syndrome Isolation Precaution among Hospital Nurses (병원 간호사의 중동호흡기증후군 격리 지침에 대한 지식과 수행도)

  • Kim, Sunju;Song, Rhayun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.25 no.1
    • /
    • pp.46-57
    • /
    • 2018
  • Purpose: The purposes of the study were to examine the knowledge and practice about Middle East Respiratory Syndrome (MERS) isolation precaution, and to explore influencing factors of the isolation practice among hospital nurses. Methods: A total of 182 nurses were recruited from four general hospitals where MERS patients had been treated. The knowledge and practice of MERS isolation precaution were measured by the scales developed based on the CDC guidelines. The collected data were analyzed by SPSS/WIN 22 with descriptive statistics, T-test, One-way ANOVA, Pearson correlation coefficients, and hierachical multiple regression analysis. Results: The nurses were 30 years old in average, and half of them had less than 5 years of clinical experience. and knowledge on droplet precautions (${\beta}=.171$, p=.019) were the significant predictors, explaining 19.6% of variance in the MERS isolation guideline practice. Clinical experience (${\beta}=.225$, p=.002), working at infection unit (${\beta}=-.203$, p=.011). Conclusion: The knowledge on droplet precaution and general knowledge on MERS were the important modifiable factor to improve the MERS isolation guideline practice among hospital nurses, even after adjusting clinical experience and demographic variables. It is necessary to develop an efficient education program on specific guidelines for prevention and management of infection by improving the knowledge on infectious disease such as MERS as well as droplet precaution which are modifiable factors.