• Title/Summary/Keyword: National Image Performance

Search Result 1,459, Processing Time 0.028 seconds

Basic Study for Selection of Factors Constituents of User Satisfaction for Micro Electric Vehicles (초소형전기차 사용자만족도 구성요인 선정을 위한 기반연구)

  • Jin, Eunju;Seo, Imki;Kim, Jongmin;Park, Jejin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.581-589
    • /
    • 2021
  • With the recent increase in the introduction of micro-electric vehicles in Korea, interest in micro-electric vehicle user satisfaction is increasing to revitalize related markets. In this paper, a basic study was conducted on the development of public services using micro-electric vehicle based on the constituent factors of user satisfaction. The survey includes: ① 'Analytic Hierarchy Process (AHP) for selecting the priority factors of user satisfaction of micro-electric vehicles', ② 'A survey of micro-electric vehicles image' to collect data in advance for providing users' preferences and transportation services for micro-electric vehicles, ③ In order to investigate the user satisfaction level of users who actually operated micro-electric vehicles, the order of 'user satisfaction survey of micro-electric vehicle drivers' was conducted. In the Analytic Hierarchy Process (AHP) analysis, it was found that users regarded as important in the order of 'user utilization data', 'vehicle movement data', and 'charging service data'. In the micro-electric vehicle image survey, users perceived micro-electric vehicles more positively in terms of "safety", 'durability', 'Ride comfort', 'design', 'MOOE (Maintenance and other operating expense)', and 'environment-friendly' when comparing micro-electric vehicles with electric motorcycles. In the survey on the user satisfaction of micro-electric vehicle drivers, the use of micro-electric vehicle did not directly affect work performance efficiency, and there was an experience of being disadvantaged on the road due to the size of the micro-electric vehicle, and driving in a cluster of micro-electric vehicle for outdoor advertisements. The city's public relations effect was great, but it was concerned about safety. In the future, based on the results of this study, we plan to build a user satisfaction structural equation model, preemptively discover feedback R&D for micro-electric vehicle utilization services in the public field, and actively seek to discover new public mobility support services.

Classification of Urban Green Space Using Airborne LiDAR and RGB Ortho Imagery Based on Deep Learning (항공 LiDAR 및 RGB 정사 영상을 이용한 딥러닝 기반의 도시녹지 분류)

  • SON, Bokyung;LEE, Yeonsu;IM, Jungho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.3
    • /
    • pp.83-98
    • /
    • 2021
  • Urban green space is an important component for enhancing urban ecosystem health. Thus, identifying the spatial structure of urban green space is required to manage a healthy urban ecosystem. The Ministry of Environment has provided the level 3 land cover map(the highest (1m) spatial resolution map) with a total of 41 classes since 2010. However, specific urban green information such as street trees was identified just as grassland or even not classified them as a vegetated area in the map. Therefore, this study classified detailed urban green information(i.e., tree, shrub, and grass), not included in the existing level 3 land cover map, using two types of high-resolution(<1m) remote sensing data(i.e., airborne LiDAR and RGB ortho imagery) in Suwon, South Korea. U-Net, one of image segmentation deep learning approaches, was adopted to classify detailed urban green space. A total of three classification models(i.e., LRGB10, LRGB5, and RGB5) were proposed depending on the target number of classes and the types of input data. The average overall accuracies for test sites were 83.40% (LRGB10), 89.44%(LRGB5), and 74.76%(RGB5). Among three models, LRGB5, which uses both airborne LiDAR and RGB ortho imagery with 5 target classes(i.e., tree, shrub, grass, building, and the others), resulted in the best performance. The area ratio of total urban green space(based on trees, shrub, and grass information) for the entire Suwon was 45.61%(LRGB10), 43.47%(LRGB5), and 44.22%(RGB5). All models were able to provide additional 13.40% of urban tree information on average when compared to the existing level 3 land cover map. Moreover, these urban green classification results are expected to be utilized in various urban green studies or decision making processes, as it provides detailed information on urban green space.

Influence of CSR Activities on Corporate Reputation Depending on Brand Equity (기업의 브랜드자산에 따른 CSR활동이 기업평판에 미치는 영향)

  • Yoon, Ki-chang
    • Journal of Venture Innovation
    • /
    • v.1 no.2
    • /
    • pp.13-34
    • /
    • 2018
  • In this case, research has been conducted to verify that the purpose of establishing a reputation for establishing a reputation for identifying brand equity is research and investigation in the context of establishing a reputation for establishing a reputation, and conducting research on CSR activities that are essential to the essential activities of companies. The survey conducted a survey on behalf of the National Center for Adult Women and Girls and Girls ' Generation, using the final round of Section 305 to develop a series of findings, including the analysis of the feasibility analysis, feasibility analysis, reliability, correlation analysis, and factors analysis. A summary of the effects of research on corporate reputation on corporate reputation according to corporate CSR activities is as follows. 1st. Brand equity will have a positive effect on the Company's reputation. The hypothesis had a significant impact on brand recognition, brand loyalty, and perceived quality, but did not have significant impact on the brand image. 2st. Brand equity will have a positive effect on ethical responsibility. The hypothesis had a significant impact on brand recognition, brand loyalty, and perceived quality, but did not have significant impact on the brand image. 3st, the brand equity will have a positive effect on the benefit of the benevolent. The hypothesis had a significant impact on brand recognition, brand loyalty, and perceived quality, but did not have significant impact on the brand image. 4st, The theory that the influence of positive(+) will affect the company's reputation has a significant impact on both ethical and philanthropic factors. 5st. The ethical responsibility was found to have no effect on the usefulness of the brand between brand assets and corporate reputation. 6st. The philanthropic responsibility was partly attributable to the fact that there was a substitution between brand equity and corporate reputation. In sum, the company needs to prioritize its brand recognition before establishing its reputation, and the reason why it should be implemented is that the other elements of the brand equity should be evaluated with the presence of other elements of the brand equity, thereby ensuring continued compliance with continuous CSR activities. As a result, consumers expect to see the performance-based role of the company as a strategic and long-term perspective, as consumers want to see the CSR activity and the corporate reputation in a long-term manner, as opposed to the financial responsibility and legal responsibilities of the past, as opposed to the past.

A Study on the Factors Affecting the Service Failure ZOT and severity Perception (서비스실패의 허용영역과 심각성 지각에 영향을 미치는 요인에 관한 연구)

  • Ock, Jung Won;Yun, Dae Hoong;Eum, Seong Won;Yim, Sun Joo
    • Journal of Service Research and Studies
    • /
    • v.6 no.2
    • /
    • pp.215-232
    • /
    • 2016
  • As the development of service marketing, research on service failure has gained more and more attention. This research aims to explore factors influencing the service failure severity perception, focus on consumers' internal propensity, ZOT(zone of tolerance) about service and comparison with other consumers in service failure situation. According to study results, it revealed that past experience satisfaction has negative effect on the zone of tolerance about service failure. Company image also has negative effect on the ZOT about service failure. While service importance has negative effect on the ZOT about service failure, it has positive effect on the perceive service failure severity. The ZOT about service failure has negative effect on perceived serviced failure severity. In contrast, social comparison perception level has no effect on perceived service failure severity, and negative affectivity also has no effect on that. In Conclusion, five hypothesis are accepted among seven hypothesis. This study gives important point to researchers and service providers in the service industry. For researchers, the result will be helpful them to further develop service failure and recovery framework. For service providers, the results will suggest specific guidelines for recovering the service failure. They can place emphasis on the serious point, so they can get a effective performance from the recovery strategy.

Neural Basis Involved in the Interference Effects During Dual Task: Interaction Between Calculation and Memory Retrieval (이중과제 수행시의 간섭효과에 수반되는 신경기반: 산술연산과 기억인출간의 상호작용)

  • Lee, Byeong-Taek;Lee, Kyoung-Min
    • Korean Journal of Cognitive Science
    • /
    • v.18 no.2
    • /
    • pp.159-178
    • /
    • 2007
  • Lee & Kang (2002) showed that simultaneous phonological rehearsal significantly delayed the performance of multiplication but not subtraction, whereas holding an image in the memory delayed subtraction but not multiplication. This result indicated that arithmetic function is related to working memory in a subsystem-specific manner. The aim of the current study was to examine the neural correlates of previous finding using fMRI. For this goal, dual task conditions that required suppression or no suppression were manipulated. In general, several areas were more activated in the interference conditions than in the less interference conditions, although both conditions were dual condition. More important finding is that the specific areas activated in the phonological suppression rendition were right inferior frontal gyrus, left angular, and inferior parietal lobule, while the areas activated in the other condition were mainly in the right superior temporal gyrus and anterior cingulate gyrus. Furthermore, the areas activated in the phonological or visual less suppression condition were right medial frontal gyrus, left middle frontal gyrus, and bilateral medial frontal gyri, anterior cingulate cortices, and parahippocampal gyri, respectively. These results revealed that sharing the processing code invokes interference, and its neural basis.

  • PDF

Erosion and Sedimentation Monitoring of Coastal Region using Time Series UAV Image (시계열 UAV 영상을 활용한 연안지역 침식·퇴적 변화 모니터링)

  • CHO, Gi-Sung;HYUN, Jae-Hyeok;LEE, Geun-Sang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.2
    • /
    • pp.95-105
    • /
    • 2020
  • In order to promote efficient coastal management, it is important to continuously monitor the characteristics of the terrain, which are changed by various factors. In this study, time series UAV images were taken of Gyeokpo beach. And the standard deviation of ±11cm(X), ±10cm(Y), and ±15cm(Z) was obtained as a result of comparing with the VRS measurement performance for UAV position accuracy evaluation. Therefore, it was confirmed that the tolerance of the digital map work rule was satisfied. In addition, as a result of monitoring the erosion and sedimentation changes using the DSM(digital surface model) constructed through UAV images, an average of 0.01 m deposition occurred between June 2018 and December 2018, and in December 2018 and June 2019. It was analyzed that 0.03m of erosion occurred. Therefore, 0.02m of erosion occurred between June 2018 and June 2019. From the topographical change analysis results, the area of erosion and sediment height was analyzed, and the area of erosion and sedimentation was widely distributed in the ±0.5m section. If we continuously monitor the topographical changes in the coastal regions by using the 3D terrain modeling results using the time series UAV images presented in this study, we can support the coastal management tasks such as supplement or dredging of sand.

Realization of the multi-phase level CGH according to the multi-channel encoding method using a PAL-SLM (PAL-SLM을 이용한 다채널 부호화 방법에 따른 다위상형 CGH의 광학적 구현)

  • Jung, Jong-Rae;Baek, Woon-Sik;Kim, Jung-Hoi;Kim, Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.299-308
    • /
    • 2004
  • We proposed more efficient encoding methods that can design a multi-channel multi-level phase only computer-generated hologram(CGH) that can reconstruct many objects simultaneously without a conjugate image. We used a fabrication technique for the pixel oriented CGH for designing the pattern of the proposed multi-channel CGH. We investigated the difference of the optical efficiency(η), mean square error(MSE) and signal-to-noise ratio(SNR) of multi-channel CGHs that were designed by three kinds of encoding methods according to the number of quantization phase levels, and we estimated the performance of the pattern of the proposed multi-channel CGH. Generally, as the number of input objects' reference patterns stored in the CGH is increased, the reconstruction quality of the CGH is degraded. But we observed through computer simulation that the diffraction efficiency of the 1-ch CGH is 70%, and those of the 2-ch, 4-ch, 8-ch CGHs are 62%, 62% and 63%. Therefore we found that the diffraction efficiencies of the multi-channel CGHs using the newly proposed encoding method are similar to that of 1-ch CGH. We implemented the CGH optically using a liquid crystal spatial light phase modulator that consisted of a PAL-SLM efficiently coupled with a XGA type LCD by an optical lens and an LD for illuminating the LCD. We discussed the output images that are reconstructed from the PAL-SLM.

Optimized Hardware Design of Deblocking Filter for H.264/AVC (H.264/AVC를 위한 디블록킹 필터의 최적화된 하드웨어 설계)

  • Jung, Youn-Jin;Ryoo, Kwang-Ki
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.1
    • /
    • pp.20-27
    • /
    • 2010
  • This paper describes a design of 5-stage pipelined de-blocking filter with power reduction scheme and proposes a efficient memory architecture and filter order for high performance H.264/AVC Decoder. Generally the de-blocking filter removes block boundary artifacts and enhances image quality. Nevertheless filter has a few disadvantage that it requires a number of memory access and iterated operations because of filter operation for 4 time to one edge. So this paper proposes a optimized filter ordering and efficient hardware architecture for the reduction of memory access and total filter cycles. In proposed filter parallel processing is available because of structured 5-stage pipeline consisted of memory read, threshold decider, pre-calculation, filter operation and write back. Also it can reduce power consumption because it uses a clock gating scheme which disable unnecessary clock switching. Besides total number of filtering cycle is decreased by new filter order. The proposed filter is designed with Verilog-HDL and functionally verified with the whole H.264/AVC decoder using the Modelsim 6.2g simulator. Input vectors are QCIF images generated by JM9.4 standard encoder software. As a result of experiment, it shows that the filter can make about 20% total filter cycles reduction and it requires small transposition buffer size.

Strength Properties of Wooden Model Retaining Wall Using Preservative Treated Square Timber of Domestic Pinus rigida Miller (리기다소나무 방부 정각재를 이용한 목재 옹벽의 강도 성능 평가)

  • Park, Jun-Chul;Kim, Keon-Ho;Lee, Dong-Heub;Hwang, Won-Joung;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.532-540
    • /
    • 2010
  • The strength properties of wooden model retaining wall made of pitch pine (Pinus rigida Miller) was evaluated. Three different types of wooden model retaining wall were made of the 11cm square timber treated with CUAZ-2 (Copper Azole). The retaining wall was made into the 4 layers of crossbar and the 3 layers of vertical-bar, of which the size was 86 cm high, 200 cm long and 96 cm wide. Type I was control and in Type II 20 cm vertical-bars and 93 cm vertical-bars were arranged alternately to decrease wood usage. TypeIII was similar to TypeII except that the connection between crossbars was reinforced with the wooden armature. In each type, the strength properties of retaining wall were investigated by horizontal loading test and the deformation of structure by image processing (AICON 3D DPA-PRO system). In horizontal loading test of Type I, Type II and Type III was 63.17, 57.80, and 60.97 kN/m, respectively. The deformation of the top layer in Type II was 1.5 times larger than in Type I and Type III. Consequently, the economic efficiency and strength performance were better in Type III than in Type I and Type II.

A Study on Microorganisms Antifouling and Optical Properties of the Sensing Membrane Surface Modified by Hydrophobic Sol-gels (소수성 졸-겔로 개질된 센서 막 표면의 미생물 비점착과 광학 특성 연구)

  • Kim, Sun-Yong;Rhee, Jong Il
    • Applied Chemistry for Engineering
    • /
    • v.19 no.2
    • /
    • pp.222-227
    • /
    • 2008
  • In this work we have studied the antifouling properties of the hydrophobic sol-gel modified sensing membrane and its optical properties for sensor application. E. coli JM109, B. cereus 318 and P. pastoris X-33 were cultivated in confocal cultivation dishes with glass surface, respectively. The glass surface was coated with the hydrophobic sol-gels prepared by the dimethoxy-dimethyl-silane (DiMe-DMOS) and tetramethyl-orthosilicate (TMOS). After cultivation, microorganisms adhered on the surface coated with sol-gels and glass surface were dyed by gram-staining method and the numbers of microorganisms were analyzed based on the image data of the scanning electronic microscope (SEM). A great number of microorganisms, about $2{\sim}3{\times}10^4/mm^2$, was adhered on the glass surfaces which no hydrophobic sol-gels were coated. However, the antifouling effect of the hydrophobic sol-gels was large, that microorganisms of less than $200{\sim}300/mm^2$ were adhered on the coated glass surface. The performance of the sensing membranes for detection of pH and dissolved oxygen was enhanced by recoating the light insulation layer prepared with the mixture of the hydrophobic sol-gel and graphite particles.