• Title/Summary/Keyword: National Fire Perpormance Code

Search Result 1, Processing Time 0.016 seconds

A Model Experiment Study to Secure the Straight Line Distance between the Air Inlet and Exhaust Section of the Living Room (거실제연설비중 공기유입구와 배출구간 직선거리 확보를 위한 모형실험연구)

  • Saeng-Gon Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.439-450
    • /
    • 2023
  • Purpose: When conducting fire inspections in Korea, there are objects that violate the fire protection regulations that require a straight line distance of more than 5m between the air inlet and the discharge section if the floor area is less than 400m2, and this paper analyzes the reasons and conducts a model experimental study to support the need for related fire protection regulations. Method: Domestic firefighting objects were investigated and confirmed, domestic and foreign papers, policies, and laws and regulations were examined, and spaces with a straight line distance of less than 5m and more than 5m between the air inlet and discharge section were selected and analyzed through model experiments in a living room of less than 400m2 . Result: When examining the domestic fire protection regulations (NFPCNational Fire Perpormance Code), the separation distance between the air inlet and the outlet is more than 5m when the floor area is less than 400m2 , but as a result of the actual investigation, it was confirmed that there are firefighting objects that cannot keep the separation distance. In addition, when a paper review of overseas fire protection regulations for a straight line distance of more than 5m showed that there was no regulation on the straight line distance between the air inlet and the discharge section, the model experiment showed that the discharge speed was better when the straight line distance between the air inlet and the discharge section was more than 5m than when it was less than 5m. Conclusions: In this study, when examining overseas fire laws and regulations by comparing the performance of the fire protection ratio for the straight line distance between the air inlet and the exhaust section, there is no mandatory regulation for the straight line distance, but the domestic fire protection regulations (NFPCNational Fire Perpormance Code) require more than 5m. It is hoped that this will be reflected in the design stage in the future, and a foundation will be laid to reduce the responsibility and burden of fire superintendents.