• Title/Summary/Keyword: National Artifact

Search Result 284, Processing Time 0.028 seconds

Comparison of Image Quality among Different Computed Tomography Algorithms for Metal Artifact Reduction (금속 인공물 감소를 위한 CT 알고리즘 적용에 따른 영상 화질 비교)

  • Gui-Chul Lee;Young-Joon Park;Joo-Wan Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.541-549
    • /
    • 2023
  • The aim of this study wasto conduct a quantitative analysis of CT image quality according to an algorithm designed to reduce metal artifacts induced by metal components. Ten baseline images were obtained with the standard filtered back-projection algorithm using spectral detector-based CT and CT ACR 464 phantom, and ten images were also obtained on the identical phantom with the standard filtered back-projection algorithm after inducing metal artifacts. After applying the to raw data from images with metal artifacts, ten additional images for each were obtained by applying the virtual monoenergetic algorithm. Regions of interest were set for polyethylene, bone, acrylic, air, and water located in the CT ACR 464 phantom module 1 to conduct compare the Hounsfield units for each algorithm. The algorithms were individually analyzed using root mean square error, mean absolute error, signal-to-noise ratio, peak signal-to-noise ratio, and structural similarity index to assess the overall image quality. When the Hounsfield units of each algorithm were compared, a significant difference was found between the images with different algorithms (p < .05), and large changes were observed in images using the virtual monoenergetic algorithm in all regions of interest except acrylic. Image quality analysis indices revealed that images with the metal artifact reduction algorithm had the highest resolution, but the structural similarity index was highest for images with the metal artifact reduction algorithm followed by an additional virtual monoenergetic algorithm. In terms of CT images, the metal artifact reduction algorithm was shown to be more effective than the monoenergetic algorithm at reducing metal artifacts, but to obtain quality CT images, it will be important to ascertain the advantages and differences in image qualities of the algorithms, and to apply them effectively.

Study on Characteristics of ECG Electrodes for Motion Artifact Reduction (동잡음 저감을 위한 심전도 전극 특성에 대한 연구)

  • Kang, Young-Hwan;Park, Jae-Soon;Cho, Bum-Ki;Choi, Sang-Dong;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.6
    • /
    • pp.366-371
    • /
    • 2017
  • In this paper, we introduce an electrocardiogram (ECG) system designed to solve problems caused by wetgels and motion artifacts in measuring active movement. The system is called a dry-contact ECG and was designed by considering impedance matching between skin and electrode as well as the frictional electricity between electrode and clothes. In order to create the system, we measured impedance on the skin-electrode interface, and the result was applied to the electronic circuit scheme. Moreover, we added an electrode on the back of the measurement electrode to make a flow path to ground the electrical noise. The final ECG circuit and novel electrode were used to detect real human cardiac signals from a subject who was tested while standing still and walking. The signals obtained from the two activities were nicely shaped, without any motion artifact noise. We took electrode size into account in this study because the impedance depended on the area of the electrode. An electrode of 50 mm diameter showed the best curve for the ECG signal without any electrical noise.

Conservation of Seated Iron Śākyamuni Buddha Statue from Goryeo Dynasty (고려(高麗) 철제석가여래좌상(鐵製釋迦如來坐像)의 보존)

  • Huh, Ilkwon;Yoo, Jayoung
    • Conservation Science in Museum
    • /
    • v.11
    • /
    • pp.9-16
    • /
    • 2010
  • The National Chuncheon Museum has carried out a conservation process in order to prevent corrosion of the seated iron Śākyamuni Buddha statue from Goreyo Dysnasty for its exhibition. Before the conservation process, the surface of the artifact showed exfoliation and the artifact was damaged from rear to legs so exhibition was impossible. Therefore a process to get rid of pollution and to reinforce and protect the artifact was carried out. Before the reinforcing process, a basic test was carried out using micro crystalline wax type with reference to foreign and domestic experiment results. As a result, as wax(in xylene) 5wt% of Dongnam petrochemical Ltd. showed no efflorescence and little change in surface color and was convenient to use, it was chosen as a reinforcing agent and used to suppress corrosion. For the restoration of damaged parts, an internal support was made and used with an epoxy resin, allowing removable restoration, thus increasing effectiveness for exhibition.

The Impact of Total Radiation Flux on Organic Materials under LED Lighting

  • Kim, Ji Won;Lee, Jin Hwan;Kim, Kyu Lin;Ryu, Jae Hyung;Kang, Dai Ill
    • Journal of Conservation Science
    • /
    • v.36 no.4
    • /
    • pp.236-243
    • /
    • 2020
  • In this study, an accelerated aging experiment for fabric and paper was conducted using two light emitting diode(LED) sources with different wavelength characteristics, and the discoloration under each lighting type was examined. Hanji(Korean traditional paper) and related textiles showed more discoloration under blue LEDs, while the blue wool standard showed more discoloration under white LEDs. This, indicated that the deterioration varied depending on the sample color. The the effect of the light source on artifact deterioration was primarily related to the total radiation flux(expressed in mill watts), rather than the total luminous flux(expressed in lumens). In addition, the discoloration of the investigated artifacts was dependent on the color rendering of the lighting.

Magnetization Transfer Contrast Angiography for Organized Thrombosed Intracranial Aneurysm in TOF MR Angiography: a Case Report

  • Kang, Dong-Hun;Lee, Hui Joong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.266-271
    • /
    • 2018
  • A 66-year-old woman was referred for treatment of incidental detection of two intracranial aneurysms. Time-of-flight MR angiography (TOF MRA) revealed two aneurysms at the M1 segment of the right middle cerebral artery, and clinoid segment of left internal carotid artery, respectively. On digital subtraction angiography, there was a saccular aneurysm on the left internal carotid artery, but the other aneurysm was not detected on the right middle cerebral artery. Based on comprehensive review of imaging findings, organized thrombosed aneurysm was judged as the most likely diagnosis. In the presented report, magnetization transfer (MT) pulse to TOF MRA was used, to differentiate aneurysm-mimicking lesion on TOF MRA. We report that MT technique could be effective in differentiating true aneurysm, from possible T1 high signal artifact on TOF MRA.

Cancellation of MRI Motion Artifact in Image Plane

  • Kim Eung-Kyeu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2000
  • In this study, a new algorithm for canceling a MRI artifact due to the translational motion In the image plane is described. Unlike the conventional iterative phase retrieval algorithm, in which there is no guarantee for the convergence, a direct method for estimating the motion is presented. In previous approaches, the motions in the x(read out) direction and the y(phase encoding) direction were estimated simultaneously. However, the feature of x and y directional motions are different from each other. By analyzing their features, each x and y directional motion is canceled by the different algorithms in two steps. First, it is noticed that the x directional motion corresponds to a shift of the x directional spectrum of the MRI signal, and the non-zero area of the spectrum just corresponds to the projected area of the density function on the x axis. So the motion is estimated by tracing the edges between non-zero area and zero area of the spectrum, and the x directional motion is canceled by shifting the spectrum in an reverse direction. Next, the y directional motion is canceled by using a new constraint condition, with which the motion component and the true image component can be separated. This algorithm is shown to be effective by using a phantom image with simulated motion.

  • PDF

Conservation and Restoration of Bronze Bowl with a Lid Excavated From Silver Bell Tomb in Gyeougju (경주 은령총 출토 청동제합의 보존)

  • Choi, Heeyoon;Huh, Ilkwon;Ahn, Juyoung;Park, Haksoo;Yu, Heisun
    • Conservation Science in Museum
    • /
    • v.7
    • /
    • pp.3-10
    • /
    • 2006
  • The bronze bowl with lid excavated from Eunnyeongchong Tumulus in Gyeongju had been united in the past and then damaged. We removed deteriorated adhesive and other impurities from it and reunited it. Some fragments of the artifact has been lost; in particular, only half of the whole main body remains. Therefore, it needed restoration treatment for exhibition and conservation. The lid, relatively much part of which remains, was treated with the method that could easily detach the restored part; the main body with much restored part was united using epoxy resin so that the restored part could well bear the weight of the artifact.

The transformation of ginsenosides by acid catalysis in gastric pH

  • Han, Byung-Hoon;Park, Myung-Hwan;Han, Yong-Nam;Woo, Lin-Keun;Ushio-Sankawa;Shoji-Yahara;Osamu-Tanaka
    • Archives of Pharmacal Research
    • /
    • v.4 no.1
    • /
    • pp.25-31
    • /
    • 1981
  • The ginsenosides of Korean ginseng decomposed profoundly to produce artifact products of prosapogenin $A_{1}$, $A_{2}$ and $A_{3}$ from ginsenoside Rg$_{1}$, prosapogenin $C_{1}$, $C_{2}$ and $C_{3}$ from ginsenoside Re, and prosapogenin E$_{1}$, E$_{2}$ and E$_{3}$ from ginsenoside Rb$_{1}$ by the acid treatment under physiological condition such as 37.deg.C incubation in 0.1 N HCI. 2. The chemical structures of the artifact substances were determined by the analysis CMR and mass spectra of TMS derivatives as following; table omitted.

  • PDF

Blocking Artifact Reduction in Block-Coded Image Using Interpolation and SAF Based on Edge Map

  • Park, Kyung-Nam;Lee, Gun-Woo;Kwon, Kee-Koo;Kim, Bong-Seok;Lee, Kuhn-Il
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.1007-1010
    • /
    • 2002
  • In this paper, we present a new blocking artifact reduction algorithm using interpolation and signal adaptive filter (SAF) based on the edge map. Generally, block-based coding, such as JPEG and MPEG, is the most popular image compression method. However, for high compression it produces noticeable blocking and ringing artifacts in the decoded image. In proposed method, all the block is classified into low and high frequency blocks in block classification procedure. And edge map is obtained by using Sobel operator on decoded image. And according to the block property we applied blocking artifacts reduction algorithm. Namely, four neighbor low frequency block is participated in interpolation based on edge map. And ringing artifacts is removed by applying a signal adaptive filter around the edge using edge map in high frequency block. The computer simulation results confirmed a better performance by the proposed method in both the subjective and objective image qualities.

  • PDF

The evaluation of usefulness of the newly manufactured immobilization device (치료보조기구의 제작 및 유용성 평가)

  • Seo Seok Jin;Kim Chan Yoeng;Lee Je Hee;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • Purpose : To evaluate the usefulness of the handmade patient immobilization device and to report the clinical results of it. Materials and methods : We made two fusion images and analyzed those images. One image is made with diagnostic MR image and CT image, the other with therapeutic planning MR image and CT image. With open head holder, we measured the skin dose and attenuation dose. Also, we made the planning CT couch plate with acrylic plate and styrofoam and compared artifact. Results : We could get more accurate fusion image when we use MR head holder(within 2mm error). The skin dose was reduced 2 times and the attenuation dose was reduced more than $20\%$ when open head holder used. The planning CT couch plate was more convenient than conventional board and reduced artifact remarkably. Conclusion : We could verify the localization point in the MR image which is taken with MR head holder. So we could fuse the image more accurately. The same method could be applied to PET and US image, if the alike immobilization device used. With open head holder, the skin dose and the attenuation dose was reduced. And those above devices could substitute for expensive foreign device, if those are manufactured adequately.

  • PDF