• 제목/요약/키워드: Nano Stage

검색결과 280건 처리시간 0.026초

비접촉식 진동측정 장치를 이용한 정밀 스테이지의 진동특성 평가시험 (Vibration experiment of precision stage that use laser vibrator)

  • 이재우;이강욱;임홍재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1224-1230
    • /
    • 2007
  • In this study, a new modal test method is presented to evaluate vibration characteristic of the nano imprint stage system. Since it is difficult to measure vibration level without contacting the machine component, non contacting modal test method, laser scanning system is ultrared. Finite element analysis results are compared with the modal test results.

  • PDF

압전 액츄에이터를 이용한 초정밀 위치제어장치 개발 (Development of Nano Positioning Stage using PZT Actuator)

  • 정상화;차경래
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.214-218
    • /
    • 2002
  • In recent years, precision positioning stage is demanded for some industrial fields such as semi-conductor lithography, ultra precision machining, and fabricating of nano structure. In this research, precision multi-axis positioning stage, which consists of pzt actuator, flexure, and capacitance gauge, is designed and developed. The performance of 3-axis positioning, characteristics of motion and resolution are verified.

  • PDF

$H_2/CO_2$ 혼합기체의 분리를 위한 PEI-PDMS 중공사 복합막 모듈의 다단 공정 연구 (Multi-stage Process Study of PEI-PDMS Hollow Fiber Composite Membrane Modules for $H_2/CO_2$ Mixed Gas Separation)

  • 이충섭;조은혜;하성용;정종태;임지원
    • 멤브레인
    • /
    • 제23권1호
    • /
    • pp.1-11
    • /
    • 2013
  • 혼합가스에서 $CO_2$를 선택적으로 분리할 수 있는 poly (etherimide) (PEI)-poly (dimethylsioxane) (PDMS) 재질의 복합막 및 모듈을 제조하여 $CO_2/H_2$ 분리특성을 확인하였다. 제조된 중공사 복합막 모듈은 모듈의 단수에 따라 $25^{\circ}C$, 일정 압력에서 stage-cut별로 분리된 가스의 유량, 농도, $H_2$ 회수율, $CO_2$ 제거율 등의 성능을 측정하였으며, $H_2$ 회수율을 높이기 위해 1단 시험에서 2단 직렬시험과 3단 직렬 + 병렬 시험으로 단수를 증가시켜 시험하였다. 각각의 운전조건에 대한 결과들을 확인한 결과 3단 운전조건에서 stage-cut을 0.32로 하였을 때 Product가스의 $H_2$ 농도는 97%이었으며 그때의 $H_2$ 회수율은 85%이었다. 또한, $CO_2$ 제거율은 약 90%의 결과를 얻을 수 있었으며 재순환 가스의 농도는 공급 가스와 유사하게 얻을 수 있었다.

초정밀 스테이지 설계 및 제어에 관한 연구 (A Study on the Design and Control of a Ultra-precision Stage)

  • 박종성;정규원
    • 한국공작기계학회논문집
    • /
    • 제15권3호
    • /
    • pp.111-119
    • /
    • 2006
  • The ultra-precision stage is demanded for some industrial fields such as semiconductor lithography, ultra-precision machining, and fabrication of nano structure. A new stage was developed for those applications in order to obtain nano meter resolution. This stage consists of symmetric double parallelogram mechanism using flexure hinges. The mechanical properties such as strength of the flexures and deformations along the applied force were analyzed using FEM. The stage is actuated by a piezoelectric actuator and its movement was measured by a ultra-precision linear encoder. In order to improve positioning performance, a PID controller was designed based on the identified second order transfer function. Experimental results showed that this stage could be positioned within below 5 nm resolution irrespective of hysteresis and creep by the controller.

탄소 나노 튜브-팁 제작을 위한 다자유도 나노 정렬 시스템 개발 (Development of Multi-DOF Nano Aligner System for CNT-Tip)

  • 강경수;이준석;최재성;곽윤근;김수현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.923-928
    • /
    • 2004
  • AFM tip has been used for surface profiling with a fine resolution, but there is a barrier to improve its performance because of the low aspect ratio. Many researchers have solved this problem with attaching carbon nanotube (CNT) to Si-tip. In this paper, we proposed the aligner system that composed of dual type stage system, and these stages could attach a carbon nanotube to tungsten-tip in vacuum condition. We used tungsten tip instead of Si-tip because of its conductivity. The aligner system proposed in this paper has 10 degree-of-freedom that 3 in the first stage and 7 in the second stage. With picomotors and piezotube, the first stage has the resolution about several tens of nm and the second stage has a resolution about a nm. We experimented on characterization of Nano Aligner System and operated picomotors in SEM environment.

  • PDF

3 축 나노 스테이지 동특성 해석 및 개선 (Analysis and Improvement of Dynamics Characteristic of 3-axis Nano Stage)

  • 김충;이강녕;이동주;이문구;최형길;이석원;박노철;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.555-558
    • /
    • 2005
  • The precision positioning system requires robust design to obtain enough bandwidth. Therefore, The sub-resonance occurred by the disaccord of force center and mass center should be oppressed. And it is necessary to move the flexible mode to a higher frequency. In this paper, the 3-axis nano stage was proposed and dynamic characteristics was improved by design of experiments (DOE).

  • PDF

유전체 베리어 방전형 2단 전기집진기의 인가전압 파형별 나노 및 서브마이크론 입자 집진 특성 (Nano and Submicron Sized Particle Collection with Various Voltage Waveforms for Dielectric Barrier Discharge Type 2-Stage ESP)

  • 박재홍;변정훈;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1261-1266
    • /
    • 2004
  • Dielectric Barrier Discharge (DBD) in air, which has been established for the production of large quantities of ozone, is more recently being applied to a wider range of aftertreatment processes for HAPs (Hazardous Air Pollutants). Although DBD has high electron density and energy, its potential use as precharging nano and submicron particles are not well known. In this work, we measured I-V characteristics of DBD and estimated collection efficiency of the particles by DBD type 2-stage ESP. To examine the particle collection with various applied voltage waveforms of DBD for nano and submicron sized, bimodal particles were generated by a electrical tube furnace and an atomizer.

  • PDF

다양한 유사체액과 인공타액에서 치과용 임플란트의 전기화학적 특성 (Electrochemical Characteristics of Dental Implant in the Various Simulated Body Fluid and Artificial Saliva)

  • 김태한;박근형;손미경;김원기;장승현;최한철
    • 한국표면공학회지
    • /
    • 제41권5호
    • /
    • pp.226-231
    • /
    • 2008
  • Titanium and its alloy have been widely used in dental implant and orthopedic prostheses. Electrochemical characteristics of dental implant in the various simulated body fluids have been researched by using electrochemical methods. Ti-6Al-4V alloy implant was used for corrosion test in 0.9% NaCl, artificial saliva and simulated body fluids. The surface morphology was observed using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX). The electrochemical stability was investigated using potentiosat (EG&G Co, 263A). The corrosion surface was observed using scanning electron microscopy (SEM). From the results of potentiodynamic test in various solution, the current density of implant tested in SBF and AS solution was lower than that of implant tested in 0.9% NaCl solution. From the results of passive film stability test, the variation of current density at constant 250 mV showed the consistent with time in the case of implant tested in SBF and AS solution, whereas, the current density at constant 250mV in the case of implant tested in 0.9% NaCl solution showed higher compared to SBF and AS solution as time increased. From the results of cyclic potentiodynamic test, the pitting potential and |$E_{pit}\;-\;E_{corr}$| of implant tested in SBF and AS solution were higher than those of implant tested in 0.9% NaCl solution.

Ti-30Ta-(3~15)Nb 합금에 HA/Ti 복합 코팅한 표면의 교류임피던스 특성 (A.C. Impedance Properties of HA/Ti Compound Layer coated Ti-30Ta-(3~15)Nb Alloys)

  • 정용훈;이호종;문영필;박근형;장승현;손미경;최한철
    • 한국표면공학회지
    • /
    • 제41권5호
    • /
    • pp.181-188
    • /
    • 2008
  • A.C. impedance properties of HA/Ti compound layer coated Ti-30Ta-($3{\sim}15$)Nb alloys have been studied by electrochemical method. Ti-30Ta binary alloys contained 3, 7, 10 and 15 wt% Nb were manufactured by the vacuum furnace system. And then specimen was homogenized at $1000^{\circ}C$ for 24 hrs. The sample was cut and polished for corrosion test and coating. It was coated with HA/Ti compound layer by magnetron sputter. The non-coated and coated morphology of Ti alloy were analyzed by X-ray diffractometer (XRD), energy X-ray dispersive spectroscopy (EDX) and filed emission scanning electron microscope (FE-SEM). The corrosion behaviors were investigated using A.C. impedance test (PARSTAT 2273, USA) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. Ti-30Ta-($3{\sim}15\;wt%$)Nb alloys showed the ${\alpha}+{\beta}$ phase, and $\beta$ phase peak was predominantly appeared in the case of increasingly Nb contents. The microstructures of Ti alloy were transformed from needle-like structure to equiaxed structure as Nb content increased. From the analysis of coating surface, HA/Ti composite surface uniformed coating layer with 750 nm thickness. The growth directions of film were (211), (112), (300) and (202) for HA/Ti composite coating on the surface after heat treatment at $550^{\circ}C$, whereas, the growth direction of film was (110) for Ti coating. The polarization resistance ($R_p$) of HA/Ti composite coated Ti-alloys were higher than those of the Ti and HA coated samples in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. Especially, corrosion resistance of Ti-Ta-Nb system increased as Nb content increased.