• Title/Summary/Keyword: NaCl electrolyte

Search Result 234, Processing Time 0.03 seconds

Changes of Sperm Motility in Black Seabream (Acanthopagrus schlegeli) by Osmolality of Diluents (희석액의 삼투질농도에 따른 감성돔 (Acanthopagrus schlegeli) 정자의 운동성 변화)

  • 장영진;임한규;장윤정
    • Journal of Aquaculture
    • /
    • v.13 no.3
    • /
    • pp.187-191
    • /
    • 2000
  • The effects of osmolality on the sperm motility in black seabream (Acanthopagrus schlegeli) were studied. Sperm motility of black seabream was suppressed when the osmolality was equal to the seminal fluid. But sperm became motile when the osmolality increased in electrolyte solution (NaCl, KCl, $CaCl_2$, $MgCl_2$) and non-electrolyte solution (mannitol, glucose, fructose, sucrose). The changes of sperm motility index (SMI) by osmolality of diluents described a parabola. In all of the diluents, SMI was the highest at ca. 1,000 mOsm/kg, which is similar to the osmolality of seawater. Sperm motility was induced by osmolality of diluents, but exposure to hypotonic or hypertonic diluents was harmful to the sperm.

  • PDF

The Effects of Ambient Ions on the Growth of Gold Nanoparticles by Laser Ablation in Liquid

  • Kwon, Hyejin;Kim, Kuk Ki;Song, Jae Kyu;Park, Seung Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.865-870
    • /
    • 2014
  • Gold nanoparticles (AuNPs) were synthesized by laser (Nd:YAG, ${\lambda}$ = 1064 nm) ablation of a gold target immersed in various aqueous electrolyte solutions (7 mM of LiCl, NaCl, KCl, NaBr, and NaI) as well as in deionized water. The surface plasmon absorption and EDX of AuNPs so produced as well as their TEM images were analyzed to investigate the effects of ambient ions on the growth and aggregation of NPs. The size of AuNPs was reduced by laser ablation in the presence of chloride and bromide ions while it increased drastically when AuNPs were formed in iodide solution. Interestingly, triangular nanoplates were synthesized only in iodide solution. Surface chemistry on AuNPs in various electrolyte solutions was explored to elucidate the role of ions on the size and stability of AuNPs.

COD Removal of Rhodamine B from Aqueous Solution by Electrochemical Treatment

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.655-659
    • /
    • 2012
  • This study elucidates the COD removal of dye (Rhodamine B) through electrochemical reaction. Effects of current density (7.2 to 43.3 $mA/cm^2$), electrolyte type (NaCl, KCl, $Na_2SO_4$, HCl), electrolyte concentration (0.5 to 2.0 g/L), air flow rate (0 to 4 L/min) and pH (3 to 11) on the COD removal of Rhodamine B were investigated. The observed results showed that the increase of pH decrease the COD removal efficiency. Whereas, the increase of current density;NaCl concentration and air flow rate caused the increase of the COD removal of Rhodamine B.

Effect of Disinfection Process Combination on E. coli Deactivation and Oxidants Generation (E. coli 불활성화와 산화제 생성에 미치는 소독 공정 결합의 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.891-898
    • /
    • 2011
  • The aim of this research was to evaluate the effect of combination of disinfection process (electrolysis, UV process) on Escherichia coli (E. coli) disinfection and oxidants (OH radical, $ClO_2$, HOCl, $H_2O_2$ and $O_3$) generation. The effect of electrolyte type (NaCl, KCl and $Na_2SO_4$) on the E. coli disinfection and oxidants generation were evaluated. The experimental results showed that performance of E. coli disinfection of electrolysis and UV single process was similar. Combination of electrolysis and UV process enhanced the E. coli disinfection and 4-carboxybenzaldehyde (4-CBA, indicator of the generation of OH radical) degradation. It is clearly showed synergy effect on disinfection and OH radical formation. However chlorine ($ClO_2$, HOCl) and oxygen type ($H_2O_2$, $O_3$) oxidants were decreased with the combination of two process. In electrolysis + UV complex process, electro-generated $H_2O_2$ and $O_3$ were reacted with UV light of UV-C lamp and increased 4-CBA degradation(increase OH radical). Disinfection of electrolyte of chlorine type was higher than that of the sulfate type electrolyte due to the higher generation of OH radical and oxidants.

Effect of Zn/NaCl ratios on the charge/discharge performance in Na-ZnCl2 battery (Na-ZnCl2 전지에서 Zn/NaCl 비율이 충방전 특성에 미치는 영향)

  • Kim, Heon-Tae;Kim, Seong-In;Choi, Hee-Lack;Park, Won-Il;Kim, Chang-Sam
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.2
    • /
    • pp.74-79
    • /
    • 2015
  • $Na-ZnCl_2$ battery, which operates as the same mechanism of $Na-NiCl_2$ battery using solid-electrolyte, is able to reduce its material cost by 40 % comparing to the $Na-NiCl_2$ battery. It has been known that the $Na-ZnCl_2$ battery produces $Na_2ZnCl_4$ as an intermediate phase during charge/discharge process. Therefore, the redox process is divided into four steps having the voltage range of 1.92~2.13 V. However, effects of the critical factors such as the composition of cathode materials, depth of charge and discharge, and additives have not been reported yet. We examined the effect of the Zn/NaCl ratios and revealed that its optimum ratio was in the range of 1.3~1.7.

Electrochemical Degradation of Phenol Using Dimensionally Stable Anode (촉매성 산화물 전극을 이용한 페놀의 전기화학적 분해)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.22 no.8
    • /
    • pp.999-1007
    • /
    • 2013
  • Electrochemical degradation of phenol was evaluated at DSA (dimensionally stable anode), JP202 (Ru, 25%; Ir, 25%; other, 50%) electrode for being a treatment method in non-biodegradable organic compounds such as phenol. Experiments were conducted to examine the effects of applied current (1.0~4.0 A), electrolyte type (NaCl, KCl, $Na_2SO_4$, $H_2SO_4$) and concentration (0.5~3.0 g/L), initial phenol concentration (12.5~100.0 mg/L) on phenol degradation and $UV_{254}$ absorbance as indirect indicator of by-product degraded phenol. It was found that phenol concentration decreased from around 50 mg/L to zero after 10 min of electrolysis with 2.5 g/L NaCl as supporting electrolyte at the current of 3.5 A. Although phenol could be completely electrochemical degraded by JP202 anode, the degradation of phenol COD was required oxidation time over 60 min due to the generation of by-products. $UV_{254}$ absorbance can see the impact of as an indirect indicator of the creation and destruction of by-product. The initial removal rate of phenol is 5.63 times faster than the initial COD removal rate.

Electrochemical polishing method using the point electrode tools(2nd) (점 전극을 이용한 전해연마 가공특성)

  • 이승훈;박규열;양순용
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.251-255
    • /
    • 1999
  • In last paper, it was suggested electrochemical polishing method using the point electrode tools. It was aimed that Machining rate in ECM using the point electrode method should be ultimately small and also high dimension accuracy and surface integrity should be fine. In this paper, the machining characteristics were investigated by using the several types of electrolyte.

  • PDF

Terahertz Spectral Characteristics of Electrolyte Solutions under Different Magnetic Fields

  • Shao, Siyu;Huang, Haiyun;Peng, Bo;Wang, Guoyang;Ye, Ping;Wang, Jiahui;Su, Bo;Cui, Hailin;Zhang, Cunlin
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.337-343
    • /
    • 2022
  • Microfluidic chips are new devices that can manipulate liquids at the micrometer level, and terahertz (THz) time-domain spectroscopy has good applicability in biochemical detection. The combination of these two technologies can shorten the distance between sample and THz wave, reduce THz wave absorption by water, and more effectively analyze the kinetics of biochemical reactions in aqueous solutions. This study investigates the effects of different external magnetic field intensities on the THz transmission characteristics of deionized water, CuSO4, CuCl2, (CH3COO)2Cu, Na2SO4, NaCl, and CH3COONa; the THz spectral intensity of the sample solutions decrease with increasing intensity of the applied magnetic field. Analysis shows that the magnetic field leads to a change in the dipole moment of water molecules in water and electrolyte solutions, which enhances not only the hydrogen-bond networking ability of water but also the hydration around ions in electrolyte solutions, increasing the number of hydrogen bonds. Increasing the intensity of this magnetic field further promotes the hydrogen-bond association between water molecules, weakening the THz transmission intensity of the solution.

Role of Electrode Reaction of Electrolyte in Electrokinetic-Fenton Process for Phenanthrene Removal (동전기-펜턴 공정에서 전해질의 전극반응이 처리효율에 미치는 영향)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • The effects of electrolytes were investigated on the removal efficiency when several different electrolytes were used to change the electrode reaction in an electrokinetic (EK)-Fenton process to remediate phenanthrene-contaminated soil. Electrical potential gradient decreased initially due to the ion entrance into soil and then increased due to the ion extraction from soil under the electric field. Accumulated electroosmotic flow was $NaCl>KH_2PO_4>MgSO_4$ at the same concentration because the ionic strength of $MgSO_4$ was the highest and $Mg(OH)_2$ formed near the cathode reservoir plugged up soil pore to inhibit water flow. When hydrogen peroxide was contained in electrolyte solution, removal efficiency increased by Fenton reaction. When NaCl was used as an electrolyte compound, chlorine ($Cl_2$) was generated at the anode and dissolved to form hypochlorous acid (HClO), which increased phenanthrene removal. Therefore, the electrode reaction of electrolyte in the anode reservoir as well as its transport into soil should be considered to improve removal efficiency of EK-Fenton process.

Electrolytic Boronzing on TiAl-based Intermetallic Compounds in Fused Salt of Borax, Potassium Chloride and Lithium Chloride Mixture (Na$_2$B$_4$O$_7$-KCl-LiCl 혼합용융욕에서 TiAl계 금속간 화합물의 전해붕화처리)

  • 이두환;김익범;이주호;김수식
    • Journal of the Korean institute of surface engineering
    • /
    • v.31 no.6
    • /
    • pp.359-370
    • /
    • 1998
  • TiAl-based intermetallic compounds were electro-bornizel in the mixture of $Na_2B_4O_7$, KCL and LiCl in the termetature rage between 850 and $1000^{\circ}C$for various times (1-5 hours)under the fixed current density of 0.5 A/$cm^2$. The optimized composition of electrolyte in this work was decided to be 76.9 wt% $Na_2B_4O_7$-19.2 wt.%(0.7KCl-0.3LiCl) -3.9 wt.% al. The samples with boronized layer were investigated by SEM, XRD and EDS. The surface micro-hardness of boronized TiAl was also evaluated using Micro Vickers Hardness Tester. The sample, boronized at $900^{\circ}C$ for 4 hours in the above composition of electrolyte under the current density of 0.5 A/$\textrm{cm}^2$, has about 36$\mu\textrm{m}$ think layer on the surface, and its surface micro-hardness was measured to be 1263 Hv. From the results of SEM, XRD and EDS, the layer consisted of $TiB_2$ sublayer and Al-oxide sub layer. Al-depleted layer below the Al-oxide sudlayer was also detected. The activation energy for formation of boronized layer in this study was calculated as 178 Kcal/moleK.

  • PDF