• 제목/요약/키워드: NaCl Aerosol

검색결과 65건 처리시간 0.03초

그래뉼 타입 활성탄 필터의 100 나노 미만 다분산 초미세먼지 표면흡착 제거 효율 연구 (Filtration Efficiency of Granular Activated Carbons to Polydisperse Ultrafine Particles through the Surface Adsoprtion)

  • 조경일;강기원;신지윤;김창혁
    • 한국입자에어로졸학회지
    • /
    • 제18권3호
    • /
    • pp.79-86
    • /
    • 2022
  • Many commercial air purifiers currently have deployed granular activated carbon (GAC) filters for removing volatile organic compounds in the indoor air. GACs are generally used to remove gaseous contaminants in the air through adsorption by the inner surfaces of pores. In addition, airborne particles can be also filtered by the surface adsorption of the GACs, which can improve the life-time of the particulate filters. In this study, the filtration efficiency of GACs to ultrafine particles through surface adsorption was investigated at different volume flow rates by deploying a continuous particle filtration system. The polydisperse sodium chloride (NaCl) particles were generated by a set of an atomizer and a diffusion dryer, and then mixed with particle-free air at different volume flow rates. The penetration of ultrafine particles and pressure drop for each experimental condition were measured to figure out the effect of the volume flow rate on the surface adsoprtion of the GACs to particles, ~ 2 mm. The particle filtration efficiency of the GACs decreased as the volume flow rate increased from 4 to 14 lpm. However, the 5 times thicker GAC filter layer decreased the penetration of ultraparticles than a preious study. The filtration efficiency of the single granule was also higher than the previous result in the literature with smaller granule filter materials.

Purification of Peroxidase from Chinese Cabbage Roots by the Reverse Micelle System

  • HAN, DAL-HO;DEUG-CHAN LEE;YEON-HO JEONG;BONG-YOUNG CHOI;SANG-YOUNG LEE;HAE-IK RHEE
    • Journal of Microbiology and Biotechnology
    • /
    • 제8권5호
    • /
    • pp.466-470
    • /
    • 1998
  • The basic and optimum conditions for the extraction of peroxidase from Chinese cabbage root applying the reverse micelle system were investigated. In order to purify Peroxidase (POX) from crude extract of Chinese cabbage roots, isooctane containing 110 mM Aerosol OT (AOT) was well mixed with the same volume of crude extracts containing 50 mM NaCl and 30 mM Tris-HCI buffer of pH 8.0. After centrifugation, AOT reverse micelle containing the isooctane phase were mixed with 80 mM Tris-HCI buffer at pH 7.0 containing 1 M KCl. From these operations, POX was purified 20-fold with a 60% yield. For further purification, DEAE-Toyopearl column chromatography was applied, and it showed a single protein band on SDS-polyacrylamide gel electrophoresis. The resulting POX showed 93-fold purification with a 40% yield.

  • PDF

A Chemical Analysis of Airborne Particulates at the near Coast Site, Ul-jin Geun Gyungbook

  • Lee, Dong Sub;Park, Jin Sik
    • 한국환경과학회지
    • /
    • 제24권5호
    • /
    • pp.615-622
    • /
    • 2015
  • East Asia is characterized by anthropogenic emissions resulting from the large population and fast economic growth of this region. Since the prevailing wind is westerly and northwesterly, emissions from Ul-jin can be expected to contribute to acidic deposition increase in downwind direction. Aerosols collected at the near coast site, Uljin geun, gyungbook and were analyzed for $NH_4{^+}$, $Mg^{2+}$, $Na^+$, $Ca^{2+}$, $Cl^-$, $SO_4{^{2-}}$, and $NO_3{^-}$ from Aug. 2012 to Feb. 2013. The seasonal averaged aerosol concentration showed the highest potassium and calcium ion in winter and the highest ammonium ion due to a meadow and high solar intensity in summer. Sodium and chloride ion showed the same ratio all seasons and sulfate and nitrate species showed the maximum value in winter Chemical components of aerosols collected at the near coast site, Uljin geun, gyungbook were lower by 16 to 73% than those collected at other similar environment site such as kanghwa, yangyang. Comparing air quality data at the near coast site, Uljin geun, gyungbook, There was found that Uljin coast site is less influenced by the sea salts(potassium, magnesium, calcium) and nss-$SO_4{^{2-}}$ percentage is 3~13% higher than similar condition site.

전기가열 튜브로를 이용한 나노/서브마이크론 입자의 발생 (Generation of Nano/Submicron Particles Using an Electrically Heated Tube Furnace)

  • 지준호;배양일;황정호;배귀남
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1734-1743
    • /
    • 2003
  • Aerosol generator using an electrically heated tube furnace is a stable apparatus to supply nanometer sized aerosols by using the evaporation and condensation processes. Using this method, we can generate highly concentrated polydisperse aerosols with relatively narrow size distribution. In this work, characteristics of particle size distribution, generated from a tube furnace, were experimentally investigated. We evaluated effects of several operation parameters on particle generation: temperature in the tube furnace, air flow rates through the tube, size of boat containing solid sodium chloride(NaCl). As the temperature increased, the geometric mean diameter increased and the total number concentration also increased. Dilution with air affected the size distribution of the particles due to coagulation. A smaller sized boat, which has small surface area to contact with air, brings smaller particles of narrow size distribution in comparison of that of a larger boat. Finally, we changed the electrical mobility diameter of aggregate sodium chloride particles by varying relative humidity of dilution air, and obtained non-aggregate sodium chloride particles, which are easy to generate exact monodisperse particles.

응축 증발법을 통한 서브마이크론 입자의 단극하전 특성 (Characteristics of Unipolar Charging of the Submicron Particles by the Condensation-Evaporation Method)

  • 최영주;김상수
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.186-192
    • /
    • 2006
  • We applied a new charging system using the condensation and evaporation method to charge the submicron particles with a uniform charging performance. The monodispersed NaCl submicron particles were condensed by n-butanol vapor and grew up to micron droplets with a same size, regardless of their initial size. Those condensed droplets were charged in an indirect corona charger. The indirect corona charger consisted of the ion generation zone and the particle charging zone. In the ion generation zone, Ions were generated by corona discharge and some of them moved into the particle charging zone by a carrier gas and mixed with the condensed droplet. And finally, the charged and condensed droplets dried through an evaporator to shrink to their original size. The average charge and penetration rate of the particles before and after evaporation were measured by CPC and aerosol electrometer and compared with those of a conventional corona charger. The results showed that the average charge was $5\~7$ charges and the penetration rate was over $90\%$, regardless of the initial particle size.

다단 임팩터(MOUDI)의 조대 입자 채취 특성 (Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles)

  • 배귀남;지준호;문길주
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.799-804
    • /
    • 1999
  • Particle collection characteristics of the MOUDI cascade impactor has been studied for coarse particles in the range of 2 to 20$mu extrm{m}$ in aerodynamic diameter. A vibrating orifice aerosol generator was empolyed to generate monodisperse test aerosols. The oleic acid and sodium chloride(NaCl) particles were used as test aerosols. Aluminum foil and Teflon filter were selected as impaction media. The sampling flow rate was changed from 25 to 35L/min. Particle collection efficiency for single stage was examined for liquid particles. The stage response was obtained experimentally for the cascade impactor composed of three stages and a backup filter. The results showed that most of particle collection efficiencies measured in this work are similar to the efficiency curves obtained by Marple et al.(1991). For particles less than cut-off size of the stage, the collection efficiencies of solid particles are similar to those of loquid particles. However, the collection efficiency of solid particles decreases with mereasing particle diameter for the particles greater than the actual cut-off size of the impactor. The particle collection efficiency increases with increasing sampling flow rate at the same particel size. However, the collection efficiency curves seem not to be greatly shifted with the flow rate. The stage responses obtained by direct measurements in this work are in good agreement with those derived from the collection efficiency curves for single stage.

  • PDF

Effects of Inorganic Aerosols on the Gas-Phase Reactions of the Hydroxyl Radical with Selected Aliphatic Alkanes

  • Oh, Sewon;Andino, Jean M.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제19권E3호
    • /
    • pp.129-136
    • /
    • 2003
  • Effects of inorganic aerosols on the kinetics of the hydroxyl radical reactions with selected aliphatic alkanes have been investigated using the relative rate technique. The relative rates in the absence and presence of aerosols were determined for n-butane, n-pentane, n-hexane, n-octane, and n-decane. P-xylene was used as a reference compound. Inorganic aerosols including (NH$_4$)$_2$SO$_4$, NH$_4$NO$_3$, and NaCl aerosols at two different aerosol concentrations that are typical of polluted urban conditions were tested. Total surface areas of aerosols were 1400 (Condition I) and 3400 $\mu$$m^2$ cm$^{-3}$ (Condition II). Significant changes in the relative rates in the presence of the inorganic aerosols were not observed for the n-butanel/$.$OH, n-pentanel/$.$OH, n-hexanel/$.$OH, n-octanel/$.$OH, and n-decanel/$.$OH reactions versus p-xylenel/$.$OH reaction. These results suggest that the promoting effects depend on the semiconducting property of the aerosols and the nature of the organic compounds.

제주시 도로변에서의 에어로졸의 입경별 분포 특성 (Roadside Aerosols Size Distribution Characteristics in Jeju City)

  • 이기호;김수미;허철구
    • 한국환경과학회지
    • /
    • 제30권9호
    • /
    • pp.727-739
    • /
    • 2021
  • Measurements on mass size distribution of roadside aerosols were obtained in downtown Jeju City from July 2018 to May 2020 using an 8-stage cascade impactor sampler and the compositions of aerosols were analyzed. The mass size distribution of total aerosols was bimodal with aerosols existing in both the fine and coarse modes. The mass size distributions of Na+, Mg2+, Ca2+, Cl-, NH4+ and SO42- were unimodal, whereas that of K+ was bimodal. For NO3-, the size distribution in winter and spring was bimodal with the peaks in both fine and coarse modes, whereas for summer and autumn the distribution was unimodal with a peak in the coarse mode. NH4+ was found to co-exist with SO42- in the fine mode with an average molar ratio of [NH4+]/[SO42-] equal to 2.05. Good correlation was observed between NO3- and NH4+ in the fine mode particles in spring and winter. Based on the value of the marine enrichment factor for Cl-, Mg2+, K+, Ca2+ and SO42-, it may be inferred that a major part of the roadside aerosols in downtown Jeju City was largely contributed by terrigenous sources, although the influence of sea salt was normally present.

서울시 지하철 승강장의 스크린도어 설치 전·후 PM10 오염원의 기여도 비교 연구 (A Comparative Study on PM10 Source Contributions in a Seoul Metropolitan Subway Station Before/After Installing Platform Screen Doors)

  • 이태정;전재식;김신도;김동술
    • 한국대기환경학회지
    • /
    • 제26권5호
    • /
    • pp.543-553
    • /
    • 2010
  • Almost five million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan. As the subway system is typically a closed environment, indoor air pollution problems frequently occurs and passengers complain of mal-health impact. Especially $PM_{10}$ is well known as one of the major pollutants in subway indoor environments. The purpose of this study was to compare the indoor air quality in terms of $PM_{10}$ and to quantitatively compare its source contributions in a Seoul subway platform before and after installing platform screen doors (PSD). $PM_{10}$ samples were collected on the J station platform of Subway Line 7 in Seoul metropolitan area from Jun. 12, 2008 to Jan. 12, 2009. The samples collected on membrane filters using $PM_{10}$ mini-volume portable samplers were then analyzed for trace metals and soluble ions. A total of 18 chemical species (Ba, Mn, Cr, Cd, Si, Fe, Ni, Al, Cu, Pb, Ti, $Na^+$, $NH_4^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, and ${SO_4}^{2-}$) were analyzed by using an ICP-AES and an IC after performing proper pre-treatments of each sample filter. Based on the chemical information, positive matrix factorization (PMF) model was applied to identify the source of particulate matters. $PM_{10}$ for the station was characterized by three sources such as ferrous related source, soil and road dust related source, and fine secondary aerosol source. After installing PSD, the average $PM_{10}$ concentration was decreased by 20.5% during the study periods. Especially the contribution of the ferrous related source emitted during train service in a tunnel route was decreased from 59.1% to 43.8% since both platform and tunnel areas were completely blocked by screen doors. However, the contribution of the fine secondary aerosol source emitted from various outside combustion activities was increased from 14.8% to 29.9% presumably due to ill-managed ventilation system and confined platform space.

2015년 봄철에 선박으로 관측한 서해상 이차에어로졸 성분의 농도 및 오염 특성 (Concentration and Pollution Characteristics of Secondary Aerosol Components Over the Yellow Sea by Ship-Borne Observation in Spring, 2015)

  • 고희정;강창희;차주완;류상범
    • 대기
    • /
    • 제27권1호
    • /
    • pp.29-40
    • /
    • 2017
  • The $PM_{10}$ and $PM_{2.5}$ particles over the Yellow Sea of Korea were collected by ship-borne observation during two cruises in spring, 2015. Their water-soluble ionic components such as $NH_4^+$, $Na^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $SO_4^{2-}$, $NO_3^-$, $Cl^-$, $F^-$, $CH_3COO^-$, $HCOO^-$, and $CH_3SO_3^-$ were analyzed, in order to examine the pollution characteristics of the secondary aerosol components. The comparative study of particle size distribution has resulted that $NH_4^+$, $nss-SO_4^{2-}$, $nss-Mg2+$, $nss-K^+$, $HCOO^-$, and $CH_3SO_3^-$ species mostly existed in fine particle mode. Meanwhile, nss-F-and sea-salt species were distributed in both fine and coarse particle mode, $NO_3^-$, $nss-Ca^{2+}$, $CH_3COO^-$ species were rich in coarse particle mode. The concentrations of secondary pollutants($nss-SO_4^{2-}$, $NO_3^-$, $NH_4^+$) increased in fine particles, and those of natural components ($nss-Ca^{2+}$, Sea-salt) increased in coarse particles. $NH_4^+$ exists as the form of $(NH_4)_2SO_4$ and $NH_4NO_3$, and mostly as $(NH_4)_2SO_4$ in fine particles. $NH_4NO_3$ has lower content compared to $(NH_4)_2SO_4$, and it mostly existed in fine particles at Yellow Sea I and in coarse particles at Yellow Sea II. The concentration ratios of $NO_3^-/nss-SO_4^{2-}$ for Yellow Sea I and Yellow Sea II were 0.52 and 0.16 in coarse particles, and they were 0.64 and 0.38 in fine particles, respectively, showing that the stationary source emissions were more important than mobile source emissions in Yellow Sea II (except Passage II-4).