• Title/Summary/Keyword: Na-Cl type

Search Result 567, Processing Time 0.031 seconds

A Study on groundwater and pollutant recharge in urban area: use of hydrochemical data

  • Lee, Ju-Hee;Kwon, Jang-Soon;Yun, Seong-Taek;Chae, Gi-Tak;Park, Seong-Sook
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.119-120
    • /
    • 2004
  • Urban groundwater has a unique hydrologic system because of the complex surface and subsurface infrastructures such as deep foundation of many high buildings, subway systems, and sewers and public water supply systems. It generally has been considered that increased surface impermeability reduces the amount of groundwater recharge. On the other hand, leaks from sewers and public water supply systems may generate the large amounts of recharges. All of these urban facilities also may change the groundwater quality by the recharge of a myriad of contaminants. This study was performed to determine the factors controlling the recharge of deep groundwater in an urban area, based on the hydrogeochemical characteristics. The term ‘contamination’ in this study means any kind of inflow of shallow groundwater regardless of clean or contaminated. For this study, urban groundwater samples were collected from a total of 310 preexisting wells with the depth over 100 m. Random sampling method was used to select the wells for this study. Major cations together with Si, Al, Fe, Pb, Hg and Mn were analyzed by ICP-AES, and Cl, N $O_3$, N $H_4$, F, Br, S $O_4$and P $O_4$ were analyzed by IC. There are two groups of groundwater, based on hydrochemical characteristics. The first group is distributed broadly from Ca-HC $O_3$ type to Ca-C1+N $O_3$ type; the other group is the Na+K-HC $O_3$ type. The latter group is considered to represent the baseline quality of deep groundwater in the study area. Using the major ions data for the Na+K-HC $O_3$ type water, we evaluated the extent of groundwater contamination, assuming that if subtract the baseline composition from acquired data for a specific water, the remaining concentrations may indicate the degree of contamination. The remainder of each solute for each sample was simply averaged. The results showed that both Ca and HC $O_3$ represent the typical solutes which are quite enriched in urban groundwater. In particular, the P$CO_2$ values calculated using PHREEQC (version 2.8) showed a correlation with the concentrations of maior inorganic components (Na, Mg, Ca, N $O_3$, S $O_4$, etc.). The p$CO_2$ values for the first group waters widely ranged between about 10$^{-3.0}$ atm to 10$^{-1.0}$ atm and differed from those of the background water samples belonging to the Na+K-HC $O_3$ type (<10$^{-3.5}$ atm). Considering that the p$CO_2$ of soil water (near 10$^{-1.5}$ atm), this indicates that inflow of shallow water is very significant in deep groundwaters in the study area. Furthermore, the P$CO_2$ values can be used as an effective parameter to estimate the relative recharge of shallow water and thus the contamination susceptibility. The results of our present study suggest that down to considerable depth, urban groundwater in crystalline aquifer may be considerably affected by the recharge of shallow water (and pollutants) from an adjacent area. We also suggest that for such evaluation, careful examination of systematically collected hydrochemical data is requisite as an effective tool, in addition to hydrologic and hydrogeologic interpretation.ion.ion.

  • PDF

Geochemistry and Stable Isotopes of Carbonated Waters in South Korea (남한 탄산수의 지구화학적 특성과 안정동위원소 조성)

  • 윤정아;김규한
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.3
    • /
    • pp.116-124
    • /
    • 2000
  • Geochemical and isotopic analyses were carried out to investigate hydrochemical characteristics, source of carbon species in the carbonated waters in South Korea. Most Korean carbonated waters from different geologic settings are characterized by a Ca-HCO$_3$type with a relatively low pH range from 5.3 to 6.3 (avg. 6.0). The concentrations of cations and anions in the carbonate waters are in the order of Ca$^{2+}$>Na$^{+}$>Mg$^{2+}$>Si$^{4+}$>Fe$^{2+}$>K$^{+}$ and HCO$_3$$^{-}$>SO$_4$$^{2-}$>Cl$^{-}$, respectively. The HCO$_3$$^{-}$ ion is more enriched in the carbonated water from the sedimentary rock and granitic rock of Mesozoic age in the Gyungsang basin(GII) and the Precambrian metamorphic rock and Jurassic granitic rocks of the Gyunggj massif in the Gangwon province(GⅠ) than those of the meta-sedimentary rock and granite in the Ogcheon zone(GⅢ). Based on the oxygen and hydrogen isotopic data, the carbonated waters are derived from the meteoric water, showing apparent latitude and altitude effects. The $delta$$^{13}$C values of carbon species in the carbonated water are in between -6.23 and 0.0 $textperthousand$, suggesting inorganic source of carbon originated from the carbonate mineral and carbonate rock in the aquifer.

  • PDF

Nondestructive determination of physico-chemical properties in compost by NIRS

  • Seo, Sang-Hyun;Lee, Chang-Hee;Park, Sung-Hun;Cho, Rae-Kwang;Park, Woo-Churl
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1622-1622
    • /
    • 2001
  • The purpose of this research was to develop a the reflection technique with near infrared (NIR) radiation for estimating physico-chemical properties in compost. The composts (cattle, pig, chicken and waste composts) were air dried and then ground to pass through a 0.5 or 2mm sieve for the physico-chemical properties and spectroscopic determinations. The physico-chemical properties of compost were shown high values ; moisture(30-60%), T-N(0.8-2.9%), organic matter(29-89%), pH(5.89-9.60) K$_2$O(0.27-5.66%), P2O$\sub$5/(0.07-2.62%), CaO(0.03-4.80%), MgO(0.09-1.56%), NaCl(0.01-1.13%), EC(1.41-13.76dS/m). Generally, we should select a simple calibration and prediction method for determining physico-chemical properties in compost under similar accuracy and precision of prediction. It should be remembered that the NIRS approach will never replace the traditional methods. However, NIRS technique may be an effective method for rapid and nondestructive measurements of a large number of compost samples. Near infrared reflectance spectra of composts was obtained by Infra Alyzer 500 scanning spectrophotometer at 2-nm intervals from 1100 to 2500nm. Multiple linear regression(MLR) or partial least square regression (PLSR) was used to evaluate a NIRS method for the rapid and nondestructive determination of physico-chemical properties and humic acid contents in composts. The standard error of prediction(SEP) for finely sized sample(<0.5mm) and coarsely sized sample(<2mm) did not show much difference. The NIR instrument of filter type showed the same accuracy of the monochromator scanning type to estimate the compost properties. The results summarized that NIR spectroscopy can be used as a routine testing method to determine quantitatively the OM, moisture, T-N, color, pH, cation content in the compost samples nondestructively.

  • PDF

The Arc Dispersion Properties by Switching of High Sensitivity Type RCD Contacts (고감도형 누전차단기 접점의 스위칭에 따른 아크 비산 특성)

  • Choi Chung-Seog;Kim Dong-Woo;Kim Young-Seok;Lee Ki-Yeon
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.63-68
    • /
    • 2005
  • In this study, the arc dispersion properties were analyzed according to switching of high sensitive type Residual Current Protective Device(RCD) contacts. Arc dispersion and ignition process was taken by high speed imaging system(HSIS). In this experiment, electric lamps(60 W) and heaters(950 W) were connected in parallel as loads. In case of normal RCD, it took about 2.3(ms) from the generation of arc to the extinction of uc. When arc was dispersed in normal RCD, it did not ignite cotton. Whereas, in case of RCD deteriorated by NaCl solution, the range of arc dispersion was wider and the arc lasted for 3.3[ms] more compared to normal RCD. And the arc ignited cotton. In order to prevent accidents caused by RCD, we should be careful of environmental factors, such as dust and humidity, and the parts of RCD should be used as incombustible materials.

Arthrobacter subterraneus sp. nov., Isolated from Deep Subsurface Water of the South Coast of Korea

  • Chang, Ho-Won;Bae, Jin-Woo;Nam, Young-Do;Kwon, Hyuk-Yong;Park, Ja-Ryeong;Shin, Kee-Sun;Kim, Kyoung-Ho;Quan, Zhe-Xue;Rhee, Sung-Keun;An, Kwang-Guk;Park, Yong-Ha
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.11
    • /
    • pp.1875-1879
    • /
    • 2007
  • Strain $CH7^T$, a pale yellow-pigmented bacterium and new isolate from deep subsurface water of the South Coast of Korea, was subjected to a polyphasic taxonomic study. $CH7^T$ grew between 5 and $37^{\circ}C$, pH 5.3-10.5, and tolerated up to 13% NaCl. A phylogenetic analysis based on 16S rRNA gene sequences showed that strain $CH7^T$ was associated with the genus Arthrobacter and phylogenetically closely related to the type strains Arthrobacter tumbae (99.4%) and Arthrobacter parietis (99.1%). However, DNA-DNA hybridization experiments revealed 2.1% and 12% between strain $CH7^T$ and Arthrobacter tumbae and Arthrobacter parietis, respectively. Thus, the phenotypic and phylogenetic differences suggested that $CH7^T$ should be placed in the genus Arthrobacter as a novel species, for which the name Arthrobacter subterraneus sp. novo is proposed. In addition, the type strain for the new species is $CH7^T$ ($=KCTC\;9997^T=DSM\;17585^T$).

Characteristic of Soil and Cambial Electrical Resistance for Investigation on Defect Cause of Planting Tree in Apartment

  • Cho, Chi-Woung;Yoo, Sun-Ah;Kim, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.21 no.11
    • /
    • pp.1307-1320
    • /
    • 2012
  • The purpose of this paper is to provide information on planting construction for healthy plant growth. To achieve this purpose, this study analyzed the planting type, planting density, withering rate, soil characteristics, and cambium electrical resistance (CER) of withered trees in an apartment complex with a high withering rate. The major plant groups examined consisted of native broad-leaved tree species (39.3%), native narrow-leaved tree species (24.2%), and native broad-leaved - exotic narrow-leaved tree species (16.4%). The planting density of the green area, where trees were planted from 0.0 to 0.3 trees per unit area, was measured as 98.4%. Withered trees were found in 19 of the 20 planted species, and the withering rate was 41.8% (610 withered/1,461 planted). Withering rates for tree species were measured as follows: Sophora japonica and Salix babylonica (100.0%), Magmolia denudata (84.3%), Lindera obtusiloba (74.7%), cornus kousa (69.3%), acer triflorum (69.2%), diospyros kaki (66.7%), Prunus yedoensis (62.8%), Acer palmatum (52.6%), Prunus armeniaca (51.1%), Chaenomeles sinensis (43.7%), Ginkgo biloba (40.9%), Zelkova serrata (31.0%), Cornus officinalis (28.6%), Taxus cuspidata (25.6%), Pinus densiflora (21.4%), Pinus parviflora (15.2%), Pinus strobus (14.6%), and Abies holophylla (10.3%). Soil chemical analyses for 18 samples revealed that as the withering rate increased, the following occurred: (a) the ratio of silt and clay in soil increased; (b) the soil pH, organic matter rate, nitrogen, available phosphorus, and cation exchange capacity (CEC) in samples were graded as "inadequate," based on the plant grading evaluation; and (c) the NaCl and cation exchange capacity were evaluated as "somewhat satisfactory." The measurement of CER for withering rate shows electrical resistance for higher withering rate are higher, which could predict that a tree will not grow well.

Water desalination by membrane distillation using PVDF-HFP hollow fiber membranes

  • Garcia-Payo, M.C.;Essalhi, M.;Khayet, M.;Garcia-Fernandez, L.;Charfi, K.;Arafat, H.
    • Membrane and Water Treatment
    • /
    • v.1 no.3
    • /
    • pp.215-230
    • /
    • 2010
  • Poly(vinylidene fluoride-co-hexafluoropropylene), PVDF-HFP, hollow fiber membranes were prepared by the dry/wet spinning technique using different polyethylene glycol (PEG) concentrations as non-solvent additive in the dope solution. Two different PEG concentrations (3 and 5 wt.%). The morphology and structural characteristics of the hollow fiber membranes were studied by means of optical microscopy, scanning electron microscopy, atomic force microscopy (AFM) and void volume fraction. The experimental permeate flux and the salt (NaCl) rejection factor were determined using direct contact membrane distillation (DCMD) process. An increase of the PEG content in the spinning solution resulted in a faster coagulation of the PVDF-HFP copolymer and a transition of the cross-section internal layer structure from a sponge-type structure to a finger-type structure. Pore size, nodule size and roughness parameters of both the internal and external hollow fiber surfaces were determined by AFM. It was observed that both the pore size and roughness of the internal surface of the hollow fibers enhanced with increasing the PEG concentration, whereas no change was observed at the outer surface. The void volume fraction increased with the increase of the PEG content in the spinning solution resulting in a higher DCMD flux and a smaller salt rejection factor.

Hydrochemical Characteristics of Groundwater in an Area Affected by Pig Carcass Burial: Leakage Detection (돼지사체 매몰지역 지하수의 수지구화학 특성: 침출수 누출 판단)

  • Oh, Junseop;Kim, Ho-rim;Lee, Jeong-Ho;Kim, Kyoung-ho;Choi, Kwang-jun;Kim, Hyeon-Koo;Yun, Seong-Taek
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.1
    • /
    • pp.30-40
    • /
    • 2018
  • To evaluate potential impacts of shallow groundwater by the leachate from buried carcass, we investigated hydrochemical characteristics of both leachate and shallow groundwater from monitoring wells and surrounding shallow groundwater wells in an area potentially affected by pig carcass burial. The hydrochemical survey was conducted before and after the relocation of a burial pit. The leachate samples and the groundwater affected by leachate showed the hydrochemistry of $Ca-HCO_3$ type with high $NH_4{^+}$ concentrations, while unaffected groundwater was mostly the $Ca(Na)-Cl+NO_3$ type due to pervasive impacts from agrochemicals. The results of factor analysis on hydrochemical data showed the followings: 1) contamination of groundwater from agro-livestock farming and livestock burial are coexisting in the study area, 2) among ionic species, $HCO_3{^-}$, $NH_4{^+}$, $NO_3{^-}$ and Mn are very useful to differentiate the groundwater contamination from leachate, and 3) groundwater contamination by leachate has been recognized around the monitoring wells even after the relocation of a burial pit, likely due to residual contaminants in surrounding soils. Therefore, it is suggested that continued monitoring of groundwater contamination should be conducted after the relocation of carcass burial pits.

Effects of TiN and ZrN Coating on Surface Characteristics of Orthodontic Wire (교정용 와이어의 표면특성에 미치는 TiN 및 ZrN 코팅영향)

  • Kim, W.G.;Kim, D.Y.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.4
    • /
    • pp.147-155
    • /
    • 2008
  • The dental orthodontic wire provides a good combination of strength, corrosion resistance and moderate cost. The purpose of this study was to investigate the effects of TiN and ZrN coating on corrosion resistance and physical property of orthodontic wire using various instruments. Wires(round type and rectangular type) were used, respectively, for experiment. Ion plating was carried out for wire using Ti and Zr coating materials with nitrogen gas. Ion plated surface of each specimen was observed with field emission scanning electron microscopy(FE-SEM), energy dispersive X-ray spectroscopy(EDS), atomic force microscopy(AFM), vickers hardness tester, and electrochemical tester. The surface of TiN and ZrN coated wire was more smooth than that of other kinds of non-coated wire. TiN and ZrN coated surface showed higher hardness than that of non-coated surface. The corrosion potential of the TiN coated wire was comparatively high. The current density of TiN coated wire was smaller than that of non-coated wire in 0.9% NaCl solution. Pit nucleated at scratch of wire. The pitting corrosion resistance $|E_{pit}-E_{rep}|$ increased in the order of ZrN coated(300 mV), TiN coated(120 mV) and non-coated wire(0 mV).

Fluid Inclusions of Daehwa and Donsan Tungsten-Molybdenum Deposits (대화(大華) 및 돈산(敦山) 중석(重石)·모리브덴 광상(鑛床)의 유체포유물(流體包有物))

  • Park, Hee-In;Choi, Suck-Won;Kim, Deog-Lae
    • Economic and Environmental Geology
    • /
    • v.18 no.3
    • /
    • pp.225-237
    • /
    • 1985
  • Mineralization of Daehwa and Donsan W-Mo deposits can be devided into three distinct depositional stages on the basis of mineral paragenesis and flnid inclusion studies; stage I, deposition of oxides and silicates ; stage II, deposition of base-metal sulfides and sulfosalts with carbonates; stage III, deposition of barren calcite and fluorite. Tungsten, molybdenum and tin mineralization occurred in stage I. Fluid inclusion studies reveal that ore fluid of stage I were homogeneous $H_2O-CO_2$ fluids containing 3.5~14.6 mol % $CO_2$. Minimum temperature and pressure of stage I ore fluids were $240^{\circ}C$ and 500 bars respectively. Salinities of aqueous type I inclusions in minerals of stage I range from 3.7 to 7.6 wt. % equi. NaCl. whereas those of $CO_2$-containing type III inclusions range from 0.3 to 4.4 wt. %. Temperatures of stage II ore fluids range from 200 to $305^{\circ}C$ on the whole and salinities were in the range of 3.2~7.2 wt. %. Homogenization temperatures of fluid inclusions in calcite and fluorite of stage III range from 114 to $186^{\circ}C$ and salinities were in the range of 0.9~4.3 wt. %. Sulfur fugacities during stage II deduced from mineral assemblages and tamperature data from fluid inclusions declined from earlier to later in the range of $10^{-11}{\sim}10^{-18}atm$. Fluid inclusion evidences suggest that the dominance of $CO_2$ in ore fluid during W-Mo mineralization is the characteristic features of Cretaceous W-Mo deposits of central district of Korea compared to those of Kyeongsang basin district.

  • PDF