• Title/Summary/Keyword: NY/PP

Search Result 31, Processing Time 0.024 seconds

Fundamental Properties of Fiber Reinforced Lean Concrete for Pavements Depending on Various Types of Fiber (섬유종류 변화에 따른 도로 포장용 린 콘크리트의 기초적 특성)

  • Jeon, Kyu-Nam;Baek, Dae-Hyun;Jung, Woo-Tai;Park, Jong-Sup;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.265-266
    • /
    • 2010
  • In this study, reduction of the crack in the lean concrete for pavements by combining different types of fibers is discussed to compare and verify its validities. Experimental result using NY fibers is depending on excellent aspect ratio and hydrophilic. Vebe time has shown good results. In addition, the addition of PP fiber had most favorable flexural strength.

  • PDF

Rheological Characteristics of Fiber-Reinforced High-Strength AFR Concrete (섬유보강 고강도 내화콘크리트의 레올로지 특성 분석)

  • Choi, Sun-Mi;Lee, Bum-Sik;Bae, Kee-Sun;Kim, Sang-Yun;Park, Su-Hee
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.543-544
    • /
    • 2009
  • The fiber(NY, PP) known to the effective material on improvement of the fire-resistance of HSC(high strength concrete) has a difference for fluidity according to the variation of a length and contents of fiber. In this study, to analyze the effect of a length and contents of the fiber on the fluidity of HSC and fheological characteristics, we calculated a viscosity of mortar by mini slump-flow, simple V-lot and viscometer. With the test results, the fluidity characteristic showed a moderate difference by a length and contents of the fiber, but showed a significant difference by increase of the fiber contents. ${\ast}$ AFR Concrete (Advenced Fire Resistant Concrete)

  • PDF

Development and Characteristics of the x-ray transmission anode tube for the thickness measurement of film (필름 두께 측정용 투과 양극형 x-ray tube의 개발 및 특성)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.240-246
    • /
    • 2008
  • The x-ray transmission anode Ag-target tube was developed to apply for the thickness measurement of film in the thickness range of several tens$\sim$several hundreds ${\mu}m$ and its characteristics were evaluated. The energy distribution and dose of x-ray from Ag-target tube was investigated at the tube voltage near 10 kV, and discussed in comparition with that from W-target tube. The energy distribution and dose of x-rays passing through film were measured with various thickness of Ny and PP film. From these results, it was confirmed that our x-ray tube can be applied for the thickness measurement of film.

Development Properties of Rebar in Tension with High Strength Concrete (인장을 받는 고강도철근콘크리트 부재의 정착성능 평가)

  • Park, Su-Hee;Lee, Bum-Sik;Kim, Sang-Yeon;Park, Seoung-Sik;Bae, Kee-Sun;Kim, Seong-Deok
    • Land and Housing Review
    • /
    • v.2 no.1
    • /
    • pp.53-60
    • /
    • 2011
  • In this study, development tests varying with concrete strength, development length, and the rate of fiber mix ratio are carried out to evaluate the development characteristics of high-strength concrete member with 80MPa, and the applicability of estimated standards of development length in KCI 2007. As a result, it can be expected that minimum development length of KCI 2007 is applicable to high-strength concrete member with 80MPa. Although the mixed fiber(NY+PP) to secure fire resistance performance of high-strength concrete is included up to 0.1%, it does not affect the development characteristics.

Mechanical Properties of High Strength Concrete Subjected to Elevated Temperature Depending on Fiber Types and Contents (혼입 섬유종류 변화에 따른 고온가열 고강도 콘크리트의 역학적 특성)

  • Kim, Sang-Shik;Song, Yong-Won;Lee, Bo-Hyeong;Yang, Seong-Hwan;Kim, Seoung-Soo;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.95-98
    • /
    • 2007
  • This study investigates the mechanical properties of the high strength concrete in the region of 80MPa corresponding to the temperature and fiber content change. For the properties of the fresh, slump flow is $600{\pm}100mm$, and air content is $3.0{\pm}1.0%$. They satisfy each targets, and there was no difference for the each fiber types. As the propertied of the hardened concrete, the compressive strength at 28 days is indicated over 80MPa, and they are similar to the change of the fiber types. The residual compressive strength in response to the temperature change of the NY, PP, and NY+PP fiber at $200^{\circ}C$ are increased by 115, 114, and 110% on the standard condition, and it is suddenly decreased at $400^{\circ}C$. They are decreased by 33, 19, and 16% on the standard condition at $800^{\circ}C$.

  • PDF

Evaluation on Fire Resistance Performance of High Strength Concrete Containing Fibre (섬유혼입 고강도 콘크리트의 내화성능 평가)

  • Song, Young-Chan;Kim, Yong-Ro;Kim, Ook-Jong;Lee, Do-Bum
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.129-135
    • /
    • 2010
  • The purpose of this research is to secure fundamental data on the application of fibre as a fire resistance method for more than 60 MPa high-strength concrete through an examination of mechanical properties and fire resistance performance. The results are as follows: 1) When there are less than 0.5~1.0kg/$m^3$ contents of PP and NY fibre for 60MPa and less high strength concrete, 1.0kg/$m^3$ contents of PP and NY fibre for less than 80MPa high strength concrete and 1.5kg/$m^3$ contents of NY fibre for more than 80MPa high strength concrete, the effect of fibre contents on workability and strength development is not significant. 2) Based on the result of a 3-hour fire resistance test for mock-up column, it is necessary to secure 50 mm of covering depth for the regulation of fire resistance performance of high strength concrete to the standards of The Ministry of Land, Transport and Maritime Affairs. 3) It is necessary to secure more than 400mm of column size for stable fire resistance performance.

Effect of Packaging Material on Quality of Kimchi During Storage (포장재질이 김치의 품질변화에 미치는 영향)

  • Kim, Yun-Ji;Hong, Seok-In;Park, Noh-Hyun;Chung, Tae-Yon
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.62-67
    • /
    • 1994
  • Quality change of Kimchi packaged with Ny/PE, Ny/CPP (PPtray+Ny/CPP cover), Cryovac BK-1, BK-4, and PET/Al/PE film was observed during storage at $5^{\circ}C$ (97%RH) and $20^{\circ}C$ (76%RH). To evaluate quality change of Kimchi, gas composition of package, pH, acidity, color, growth of lactic acid bacteria, and sensory score were measured periodically. Regarding to gas composition of package, Kimchi packaged with PET/Al/PE showed higher oxygen concentration at the beginning of storage than the others; carbon dioxide concentration was almost 100% at the end of storage. Carbon dioxide concentration of Kimchi packaged with Cryovac BK-1 and BK-4 which has higher gas permeability than the others, was increased to a maximum and then decreased due to permeation of gas during storage; oxygen concentration was increased. Unlike Kimchi packaged with Ny/PE, Ny/CPP, and PET/Al/PE, package swelling was not observed in Kimchi packaged with Cryovac BK-1 and BK-4 during storage. Although pH change was not significant depending on the packaging material, Kimchi packaged with Cryovac BK-1 and BK-4 showed lower pH value and higher acidity than those of the others. Color change of Kimchi was different depending on the packaging material during storage. Difference of the growth of lactic acid bacteria and sensory evaluation were not significant among Kimchi packaged with different packaging material during storage at either temperature. In conclusion, the effect of packaging materials on the quality change of Kimchi was not significant; however, to prevent from swelling of packaged Kimchi which is one of the most serious problem during storage and distribution, might be avoided by using relatively high $CO_2$ permeable film than high gas barrier film.

  • PDF

Engineering Properties of Cement Mortar Using Organic Fiber Rehabilitation Materials (유기질 섬유보강재를 사용한 시멘트 모르터의 공학적 특성)

  • Shin Hyun-Sup;Park Yong-Kyu;Kim Kyoung-Min;Lee Gun-Cheol;Hwang In-Sung;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.39-42
    • /
    • 2005
  • This study investigates influence of organic fiber reinforced materials, affecting crack reduction of cement mortar using low grade natural sand(LNS). According to the test, for the properties of fresh mortar, the mortar using natural sand(NS) exhibited that flow value increased until adding most of fiber less than 1$\%$, except for Polyvinly alchol fiber(PVA), and then it decreased. Meanwhile, the mortar mixed with LNS showed that increase of fiber content decrease flow value, regardless of fiber type. Air content increased in the mortar adding nylon fiber(NY) and polypropylene fiber(PP), while it maintained or decreased in the mortar adding cellulose fiber(CL) and PVA. Compressive strength of the mortar does not affect during early age, but mortar using NS and adding 0.1$\%$ of fiber content increased the value, except for PP, at 28 age days, while the mortar mixed with LNS decreased. For the properties of tensile strength, mortar, using NS and adding individually PP and PVA, exhibited higher value. Especially 0.1$\%$ of NY provided the highest value. In addition, the mortar mixed with LNS resulted in improved tensile value as fiber content increased. It is demonstrated that mortar using LNS led to higher length change ratio than natural sand.

  • PDF

Evaluation on Spalling Properties of Ultra High Strength Concrete with Combined Fiber (복합섬유를 혼입한 초고강도 콘크리트의 폭렬 특성 평가)

  • Son, Myung-Hak;Kim, Gyu-Yong;Min, Choong-Siek;Lee, Tae-Gyu;Koo, Kyung-Mo;Youn, Yong-Sang
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.209-210
    • /
    • 2011
  • This study is aimed to draw a optimum combined fiber mix condition to improve spalling resistance and flowability of ultra high-strength concrete. As a result, W/B 12.5% concrete specimens were prevented spalling with PE0.05+ PP0.1, PE0.05+NY0.1 and W/B 12.5% concrete specimens were prevented spalling with all of combined organic fiber mix condition. But There is no significant influence of steel fiber under 5% volume ratios to prevent spalling. In the scope of this study, we suggest that condition of optimum volume ratio PE0.05+NY0.1 is to improve spalling resistance, flowability and residual compressive strength.

  • PDF

A Study on the Thermal Stability of Carpet in Air Condition (에어컨디션에서 카펫의 열안정성에 관한 연구)

  • Park, Keun-Ho;Lee, Soo;Song, Ju-Yeong;Lee, Ki-Chul
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.362-367
    • /
    • 2006
  • This paper describes the experiments for investigating the effects of thermal stability of several commercial carpet mate materials. The melting point and thermal decomposition temperature was measured by means of a differential scanning calorimeter(DSC) in air condition. The DSC data and burning test results of nylon bulked continuous filament(N-BCF) yarn 100%, nylon(NY), polypropylene(PP), and a new material named polytrimethyleneterephthalate(PTT) were analysed to obtain the effect on their thermal stability. Conclusively, we observed that PTT and PP were approximately $380^{\circ}C$ and $240^{\circ}C$ to start the thermal decomposition, respectively. In other words, PTT is thermally the most stable material for carpet manufacturing.