• Title/Summary/Keyword: NS5

Search Result 842, Processing Time 0.031 seconds

Application of a LIBS technique using femtosecond and nanosecond pulses for the CIGS films analysis (펨토초 및 나노초 레이저를 이용한 박막태양전지의 레이저 플라즈마 분광 분석)

  • Lee, S.H.;Choi, J.H.;Gonzalez, J.J.;Hou, H.;Zorba, V.;Russo, R.E.;Jeong, S.H.
    • Laser Solutions
    • /
    • v.17 no.4
    • /
    • pp.7-13
    • /
    • 2014
  • In this work, the application of laser induced breakdown spectroscopy (LIBS) for the composition analysis of thin $Cu(In,Ga)Se_2$ (CIGS) solar cell films ($1-2{\mu}m$ thickness) is reported. For the ablation of CIGS films, femtosecond (fs) laser (wavelength = 343nm, pulse width = 500fs) and nanosecond (ns) laser (wavelength = 266nm, pulse width = 5ns) were used under atmospheric environment. The emission spectra were detected with an intensified charge coupled device (ICCD) spectrometer and multichannel CCD spectrometer for fs-LIBS and ns-LIBS, respectively. The calibration curves for fs-LIBS and ns-LIBS intensity ratios of Ga/Cu, In/Cu, and Ga/In were generated with respect to the concentration ratios measured by inductively coupled plasma optical emission spectrometry (ICP-OES).

  • PDF

Time-Error Prediction of Rubidium Atomic Clock according to the Elapsed Time (루비듐 원자시계의 경과시간에 따른 시간오차 예측)

  • 김영범;정낙삼;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.3
    • /
    • pp.439-445
    • /
    • 2001
  • In this paper, we propose a method that can minimize time-error when a commercial rubidium atomic clock is used as a portable reference clock. A linear interpolation method which was widely used is not based upon long-term stability, but our new method is considered to reduce time error. The comparison results between two method have shown that time error of our new approach considering with long-term stability is better than that of linear interpolation method within observation duration about one and half days. In addition, when the role of a rubidium atomic clock as a portable reference clock is completed within 12 hours, our new method can provide at most maximum time-error of 10 ns which is shorter than 15 ns in conventional method.

  • PDF

Scaled SONOSFET NOR Type Flash EEPROM (Scaled SONOSFET NOR형 Flash EEPROM)

  • 김주연;권준오;김병철;서황열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.75-78
    • /
    • 1998
  • The SONOSFET Shows low operation voltage, high cell density, anti good endurance due to modified Fowler-Nordheim tunneling as memory charge injection method. In this paper, therefore, the NOR-type Flash EEPROM composed of SONOSFET, which has fast lead operation speed and Random Access characteristics, is proposed. An 8${\times}$8 bit NOR-type SONOSFET Flash EEPROM had been designed and its electrical characteristics were verified. Read/Write/Erase operations of it were verified with the spice parameters of SONOSFETs which had Oxide-Nitride-Oxide thickness of 65${\AA}$-165${\AA}$-35${\AA}$ and that of scaled down as 33${\AA}$-53${\AA}$-22${\AA}$, respectively. When the memory window of the scaled-down SONOSFET with 8V operation was similar to that of the SONOSFET with 13V operation, the Read operation delay times of the scaled-down SONOSFET were 25.4ns at erase state and 32.6ns at program state, respectively, and those of the SONOSFET were 23.5ns at erase state and 28.2ns at program state, respectively.

  • PDF

Noonan syndrome and RASopathies: Clinical features, diagnosis and management

  • Lee, Beom Hee;Yoo, Han-Wook
    • Journal of Genetic Medicine
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • Noonan syndrome (NS) and NS-related disorders (cardio-facio-cutaneous syndrome, Costello syndrome, NS with multiple lentigines, or LEOPARD [lentigines, ECG conduction abnormalities, ocular hypertelorism, pulmonic stenosis, abnormal genitalia, retardation of growth and sensory neural deafness] syndrome) are collectively named as RASopathies. Clinical presentations are similar, featured with typical facial features, short stature, intellectual disability, ectodermal abnormalities, congenital heart diseases, chest & skeletal deformity and delayed puberty. During past decades, molecular etiologies of RASopathies have been growingly discovered. The functional perturbations of the RAS-mitogen-activated protein kinase pathway are resulted from the mutation of more than 20 genes (PTPN11, SOS1, RAF1, SHOC2, BRAF, KRAS, NRAS, HRAS, MEK1, MEK2, CBL, SOS2, RIT, RRAS, RASA2, SPRY1, LZTR1, MAP3K8, MYST4, A2ML1, RRAS2). The PTPN11 (40-50%), SOS1 (10-20%), RAF1 (3-17%), and RIT1 (5-9%) mutations are common in NS patients. In this review, the constellation of overlapping clinical features of RASopathies will be described based on genotype as well as their differential diagnostic points and management.

Accuracy Assessment of IGSO and GEO of BDS and QZSS Broadcast Ephemeris using MGEX Products

  • Son, Eunseong;Choi, Heonho;Joo, Jungmin;Heo, Moon Beom
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.4
    • /
    • pp.347-356
    • /
    • 2020
  • In this study, Inclined Geosynchronous Orbit (IGSO) and Geostationary Orbit (GEO) of BeiDou System (BDS) and Quasi Zenith Satellite System (QZSS) satellites positions and clock errors calculated by broadcast ephemeris and compared with Multi-GNSS Experiment (MGEX) products provided by five Analysis Centers (ACs). Root Mean Square Errors (RMSE) calculated for satellite position error. The IGSO results showed that 1.82 m, 0.91 m, 1.28 m in BDS and 1.34 m 0.36 m 0.49 m in QZSS and the GEO results showed that 2.85 m, 6.34 m, 6.42 m in BDS and 0.47 m, 4.79 m, 5.82 m in QZSS in the direction of radial, along-track and cross-track respectively. RMS calculated for satellite clock error. The IGSO result showed that 2.08 ns and 1.24 ns and the GEO result showed that 1.28 ns and 1.12 ns in BDS and QZSS respectively.

Cyclosporine A (Cipol-$N^{(R)}$) Therapy in Children with Idiopathic Nephrotic Syndrome (소아 특발성 신증후군에서의 cyclosporine A(Cipol-$N^{(R)}$)의 치료 효과)

  • Hong Ihn Hee;Ko Cheol Woo;Koo Ja Hoon;Kim Ji-Hong;Kim Pyung-Kil;Cho Byoung Soo
    • Childhood Kidney Diseases
    • /
    • v.3 no.1
    • /
    • pp.48-56
    • /
    • 1999
  • Purpose : This multicenter collaboratory study was conducted to see the therapeutic efficacy and side effect of cyclosporine A (Cipol-$N^{(R)}$, Chong Kun Dang) on children with idiopathic nephrotic syndrome who experienced frequently relapsing (FR), steroid dependent (SD), or steroid resistant (SR) pattern. Patients and methods : Thirty-nine children with SD/FR NS and 3 children with SR NS were enrolled in the study. After induction of remission (SD/FR NS) with steroid or after 4 weeks of steroid therapy (SR NS), cyclosporine A was started in a dose of 4-5 mg/Kg/day in two divided dose and steroid (prednisolone or equivalent dose of deflazacort) was tapered slowly. During 16 weeks of study period, monthly check up of physical examination and various laboratory tests including BUN, creatinine, Ccr and cyclosporine blood level were done. Results : Out of 39 children with SD/FR NS, 35($89.7\%$) maintained sustained remission and at 4 weeks after therapy, values of serum protein, albumin, cholesterol, and 24 hours urinary protein excretion showed normal values. Two out of 3 children with SR NS showed and sustained remission with cyclosporine A therapy. Side reaction to cyclosporine A therapy showed hypertrichosis in 8 cases and hyperuricemia in 5 cases. However, other laboratory tests including CBC, liver profile, BUN, creatinine and GFR (creatinine clearance utilizing 24 hour urine) did not show any abnormalities during the 16 weeks of study period. Conclusion : Cyclosporine A (Cipoi-$N^{(R)}$ Chong Kun Dang) can be utilized quite effectively on children with SD/FR or SR NS and further trial of cyclosporine A on long-term basis (1-2 year period) is needed to determine it's efficacy and side effect (especially nephrotoxicity) of long-term administration of cyclosporine A.

  • PDF

IEEE Standard Floating Poing ALU with 60MHz Clock Frequency (60MHz Clock 주파수의 IEEE 표준 Floating Point ALU)

  • Yong Surk Lee
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.11
    • /
    • pp.915-922
    • /
    • 1991
  • This research paper presents an ALU unit using 1.0$\mu$m CMOS technology capable of doing IEEE standard single and double precision floating poing calculation within 32ns (2 clock) at 60 MHz clock speed. This 32ns speed was achieved by using 9ns 1's complement arithmetic 54 bit carry select adder instead of previous 2's complement adders. On the first cycle, this adder is used for addition or subtraction and the second cycle uses this adder for rounding. This reduces the number of required adders from two to one. Speed improvement is 2 to 5 times compared with previous 40MHz design. Design goal was 60MHz, however, this unit is functioning at 80 MHz at room temperature.

  • PDF

Rate Adaptation with Q-Learning in CSMA/CA Wireless Networks

  • Cho, Soohyun
    • Journal of Information Processing Systems
    • /
    • v.16 no.5
    • /
    • pp.1048-1063
    • /
    • 2020
  • In this study, we propose a reinforcement learning agent to control the data transmission rates of nodes in carrier sensing multiple access with collision avoidance (CSMA/CA)-based wireless networks. We design a reinforcement learning (RL) agent, based on Q-learning. The agent learns the environment using the timeout events of packets, which are locally available in data sending nodes. The agent selects actions to control the data transmission rates of nodes that adjust the modulation and coding scheme (MCS) levels of the data packets to utilize the available bandwidth in dynamically changing channel conditions effectively. We use the ns3-gym framework to simulate RL and investigate the effects of the parameters of Q-learning on the performance of the RL agent. The simulation results indicate that the proposed RL agent adequately adjusts the MCS levels according to the changes in the network, and achieves a high throughput comparable to those of the existing data transmission rate adaptation schemes such as Minstrel.

Tunable Composite Right/Left-Handed Delay Line with Large Group Delay for an FMCW Radar Transmitter

  • Park, Yong-Min;Ki, Dong-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.2
    • /
    • pp.166-170
    • /
    • 2012
  • This paper presents a tunable composite right/left-handed (CRLH) delay line for a delay line discriminator that linearizes modulated frequency sweep in a frequency modulated continuous wave (FMCW) radar transmitter. The tunable delay line consists of 8 cascaded unit cells with series varactor diodes and shunt inductors. The reverse bias voltage of the varactor diode controlled the group delay through its junction capacitance. The measured results demonstrate a group delay of 8.12 ns and an insertion loss of 4.5 dB at 250 MHz, while a control voltage can be used to adjust the group delay by approximately 15 ns. A group delay per unit cell of approximately 1 ns was obtained, which is very large when compared with previously published results. This group delay can be used effectively in FMCW radar transmitters.

Intravenous Fluid Selection for Unruptured Intracranial Aneurysm Clipping : Balanced Crystalloid versus Normal Saline

  • Kang, Jian;Song, Young Joo;Jeon, Sujeong;Lee, Junghwa;Lee, Eunsook;Lee, Ju-Yeun;Lee, Euni;Bang, Jae Seung;Lee, Si Un;Han, Moon-Ku;Oh, Chang Wan;Kim, Tackeun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.534-542
    • /
    • 2021
  • Objective : While balanced crystalloid (BC) could be a relevant fluid regimen with buffer system compared with normal saline (NS), there have been no studies on the optimal fluid for surgery of an unruptured intracranial aneurysm (UIA). This study aimed to compare the effects of fluid regimens between NS and BC on the metabolic and clinical outcomes of patients who underwent surgery for UIA. Methods : This study was designed as a propensity score matched retrospective comparative study and included adult patients who underwent UIA clipping. Patient groups were categorized as NS and BC groups based on the types of pre-operative fluid and the amount of fluid administered during surgery. The primary outcomes were defined as electrolyte imbalance and acidosis immediately after surgery. The secondary outcomes were the length of stay in the intensive care unit (ICU) and duration from the end of the operation to extubation. Results : A total of 586 patients were enrolled in this study, with each of 293 patients assigned to the NS and BC groups, respectively. Immediately after surgery, serum chloride levels were significantly higher in the NS group. Compared to the NS group, the BC group had lower incidence rates of acidemia (6.5% vs. 11.6%, p=0.043) and metabolic acidosis (0.7% vs. 4.4%, p=0.007). As compared to NS group, BC group had significantly shorter duration from the end of the operation to extubation (250±824 vs. 122±372 minutes, p=0.016) and length of stay in ICU (1.37±1.11 vs. 1.12±0.61 days, p=0.001). Throughout multivariable analysis, use of BC was found to be significant factor for favorable post-operative results. Conclusion : This study showed that the patients who received BC during UIA clipping had lower incidence of metabolic acidosis, earlier extubation and shorter ICU stay compared to those who received NS. Therefore, using BC as a peri-operative fluid can be recommended for patients who undergo surgery for UIA.