• 제목/요약/키워드: NRM (National Reference Method)

검색결과 2건 처리시간 0.015초

PM2.5 국가기준측정장비 선정을 위한 비교 측정 연구 (Field Performance Evaluation of Candidate Samplers for National Reference Method for PM2.5)

  • 이용환;박진수;오준;최진수;김현재;안준영;홍유덕;홍지형;한진석;이강웅
    • 한국대기환경학회지
    • /
    • 제31권2호
    • /
    • pp.157-163
    • /
    • 2015
  • To establish National Reference Method (NRM) for $PM_{2.5}$, operational performance of 5 different commercial gravimetric-based $PM_{2.5}$ measuring instruments was assessed at Bulkwang monitoring station from January 23, 2014 to February 28, 2014. First, physical properties, design, and functional performance of the instruments were assessed. Evaluation was carried out to determine whether operating method for the instruments and levels of QA/QC activities meet the data quality objectives (DQOs). To verify whether DQOs were satisfied, reproducibility of QA/QC procedures, accuracy, relative sensitivity, limit of detection, margin of error, and coefficient of determination of the instruments were also evaluated. Results of flow rate measurement of 15 candidate instruments indicated that all the instruments met performance criteria with accuracy deviation of 4.0% and reproducibility of 0.6%. Comparison of final $PM_{2.5}$ mass concentrations showed that the coefficient of determination ($R^2$) values were greater than or equal to 0.9995, and concentration gradient ranged from 0.97 to 1.03. All the instruments satisfied criteria for NRM with the estimated precision of 1.47~2.60%, accuracy of -1.90~3.00%, and absolute accuracy of 1.02~3.12%. This study found that one particular type of measuring instrument was proved to be excellent, with overall evaluation criteria satisfied.

PM2.5 자동측정장비 비교 및 정도관리 방안 (Comparison of the Real-time Measurements for PM2.5 and Quality Control Method)

  • 박미경;박진수;조미라;이용환;김현재;오준;최진수;안준영;홍유덕
    • 한국대기환경학회지
    • /
    • 제33권6호
    • /
    • pp.616-625
    • /
    • 2017
  • Measurements using five real-time particle samplers were compared to measurements using three NRM (National Reference Method system) filter-based samplers(Gravimetric method) at Incheon, Korea, between May and August, 2014. The purpose of this study was to suggest the quality assurance/quality control (QA/QC) method of each instrument for use in a real-time continuous particle sampler to measure the mass of airborne particles with an aerodynamic diameter less than $2.5{\mu}m$ ($PM_{2.5}$). Five real-time particle samplers of BAM1020, FH62C_14, TEOM, PM-711 and SPM-613 were evaluated by comparing its measured 23 hr average $PM_{2.5}$ concentrations with those measured with NRM filter-based samplers simultaneously. The parameters(e.g. Inlet heating condition, Slope factor, Film response, Intercept, Background, Span value) of the real-time samplers were optimized respectively by conducting test performance evaluation during 7 days in field sampling. For example, inlet heating temperature of TEOM sampler controls $35{\sim}40^{\circ}C$ to minimize the fluctuation of the real-time measurement data and background value of BAM1020 is the key factor affecting the accuracy of $PM_{2.5}$ mass concentration. We classified the $PM_{2.5}$ concentration according to relative humidity (80%) to identify water absorbed in aerosols by measuring the ${\beta}$-ray samplers(BAM1020, FH62C_14) and TEOM. ${\beta}$-ray samplers were not strongly affected by relative humidity that the difference of the average $PM_{2.5}$ concentration was about 5%. On the other hand, The TEOM sampler overestimated $PM_{2.5}$ mass concentration about 15% at low relative humidity (<80%).