• Title/Summary/Keyword: NR (Noise Rating)

Search Result 8, Processing Time 0.019 seconds

An active noise control window system to reduce noise rating in low frequency band (저주파 대역의 소음 평가 지수 개선을 위한 창문형 능동 소음 제어기)

  • Oh, Wongeun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.331-337
    • /
    • 2018
  • In this paper, we apply the NR (Noise Rating) to the evaluation of the residual noise of the window type ANC (Active Noise Control) and study the active noise controller for minimizing the NR value in rooms. We proposed a shape of a noise shaping filter of the Filtered-E LMS (Least Mean Square) algorithm that reduces the NR value within the effective operating frequency band of the ANC. The usefulness of the proposed scheme is verified by simulation and showed that the NR value of the residual noise is lower than the filters used in the conventional psychoacoustic ANC.

Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear

  • Biabani, Azam;Aliabadi, Mohsen;Golmohammadi, Rostam;Farhadian, Maryam
    • Safety and Health at Work
    • /
    • v.8 no.4
    • /
    • pp.364-370
    • /
    • 2017
  • Background: Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Methods: Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV102). Results: The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically (p < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant (p > 0.05). Conclusion: This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.

Psycho-acoustic Evaluation and Analysis of the Indoor Noise in Cabins of a Naval Vessel to Specify its Allowable Limit (함정의 실내소음 허용기준 설정을 위한 청감평가 및 분석)

  • Hong, Hyun-Soo;Shim, Sang-Ryul;Han, Hyung-Suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.7
    • /
    • pp.650-656
    • /
    • 2011
  • The noise inside a naval vessel is very important in considering the need for hearing protection, improving the working environment and maintaining good communications for crews living on board a naval vessel. The indoor noise of a ship usually is specified by the A-weighted sound pressure level, but other evaluating parameters are required to reflect human senses more effectively. This paper uses additional noise indices related to room acoustics, such as NR(noise rating), NC(noise criterion), RC(room criterion), PSIL(preferred speech interference level) and loudness level to evaluate the noise inside cabins on a naval vessel. Using these psychological noise indices, allowable limit of noise level in cabins is suggested through psycho-acoustic evaluation for the noise in cabins.

A Study on the Characteristics of Propagation and Attenuation of Piling Noise by SIP Method with Casing (Casing 부착 SIP공법에 의해 발생하는 항타소음의 전달 및 감쇠특성에 관한 연구)

  • 이병윤;윤해동;조원희;김재수
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.899-905
    • /
    • 1999
  • Construction equipment noise has caused much annoyance for a number of dwellers in nearby construction field and has become a very serious issure in our living environment. Therefore, in our country, a practical solution and a better method of reducing construction equipment noise are highly required in construction field. Practical solutions for the construction equipment noise, however, are very difficult because of the poorness of basic data and insufficiency of the existing research. Especially, in order to establish the sound insulation plan about pilling works noise with high sound pressure level and impactive, a real situation of sound characteristics about the noise of pilling works in foundation work demands more detail investigation. In this point, this study attempts to survey the characteristics of attenuation and propagation of construction equipment noise in pilling work using SIP(soil-cement injected precast pile) method with casing. And this study intends to get the basic data for establishment of a standard about construction noise.

  • PDF

Psycho-acoustic evaluation of the indoor noise in cabins of a naval vessel using a back-propagation neural network algorithm

  • Han, Hyung-Suk
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.4 no.4
    • /
    • pp.374-385
    • /
    • 2012
  • The indoor noise of a ship is usually determined using the A-weighted sound pressure level. However, in order to better understand this phenomenon, evaluation parameters that more accurately reflect the human sense of hearing are required. To find the level of the satisfaction index of the noise inside a naval vessel such as "Loudness" and "Annoyance", psycho-acoustic evaluation of various sound recordings from the naval vessel was performed in a laboratory. The objective of this paper is to develop a single index of "Loudness" and "Annoyance" for noise inside a naval vessel according to a psycho-acoustic evaluation by using psychological responses such as Noise Rating (NR), Noise Criterion (NC), Room Criterion (RC), Preferred Speech Interference Level (PSIL) and loudness level. Additionally, in order to determine a single index of satisfaction for noise such as "Loudness" and "Annoyance", with respect to a human's sense of hearing, a back-propagation neural network is applied.

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.

Analysis of Sound Quality Parameters of Sound Sources applied for Soundscape Design (사운드 스케이프 적용 음원의 음질 지수 분석)

  • Park, Hyeon-Ku;Song, Min-Jeong;Jang, Gil-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.814-819
    • /
    • 2004
  • When we evaluate sound, there are various methods for noise such as A-weighted SPL(sound pressure level), NC(noise criteria), NR(noise rating) and SIL(speech interference level) etc. however, it is not sufficient for the sounds supplied to public places used in soundscape design. Consequently it is needed to develop the tool for evaluating the good acoustical environment and futhermore quantifying the effect of improvement by supplying sound sources. In this study, it was tried to analyse the sound sources applied for soundscape design using sound quality parameters. The sound sources used were natural sound artificial sound. For the sound quality parameters, Loudness(L), Sharpness(S), Fluctuation strength(FL), Tonality(T), Roughness(R), Unbiased Annoyance(UA) were used and sound quality values were compared both natural and artificial sounds, depending on the convolution of sound sources with background noise, the duration, the frequency contents and the SPL. As a result, the values of L and UA have shown to be changed comparing to the other parameters, and it is necessary to analyse the correlation with subjects' responses.

  • PDF

Role of Repeated Education to the Patients with Temporomandibular Disorders (측두하악장애 치료에 있어서 반복적 주의사항 교육의 효과)

  • Ok, Soo-Min;Heo, Jun-Young;Ko, Myung-Yun;Ahn, Yong-Woo;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.1
    • /
    • pp.69-76
    • /
    • 2013
  • Aim : The purpose of this study was to investigate the hypothesis that treatment with self-checking behavior management program was valuable in the management of temporomandibular disorders compared with a existing method treatment group. Methods : All participants who are diagnosed with temporomandibular disorders were treated with medication and physical therapy. They came into the clinic at intervals of two weeks, three times. The signs and symptoms were assessed investigating Pain NRS(Numerical Rating Scale), MCO(Maximum comfortable opening), Noise NRS, LOM(Limitation of Mouth opening) NRS at every visit. Experimental group received instructions repeatedly by using self evaluation questionnaire. Control group was educated once at the beginning of treatment. The difference Pain NRS, MCO, Noise NRS, LOM NRS between first and second visits, first and third visits were estimated.. Result :Experimental group showed greater improvement on MCO difference after stopping medication(p=0.001). This improvements were prominent in the male(p=0.001) and the first or second decade of the patients(p=0.004). Conclusion : The present study showed that there was better result when educating repeatedly with using self evaluation questionnaire than educating once at the beginning of the treatment.