• Title/Summary/Keyword: NPC type 3-level inverter

Search Result 24, Processing Time 0.026 seconds

Comparative Analysis of Power Losses for Three-Level T-Type and NPC PWM Inverters (3-레벨 T-형 및 NPC 인버터의 전력 손실 비교 분석)

  • Alemi, Payam;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.173-183
    • /
    • 2014
  • In this paper, an analysis of power losses for the three-level T-type and neutral-point clamped (NPC) PWM inverters is presented, in which the conduction and switching losses of semiconductor devices of the inverters are taken into account. In the inverter operation, the conduction loss depends on the modulation index (MI) and power factor (PF), whereas the switching loss depends on the switching frequency. Power losses for the T-type and NPC inverters are analyzed and calculated at the different operating points of MI, PF and the switching frequency, in which the four different models of semiconductor devices are adopted. In the case of lower MI, the NPC-type is more efficient than the T-type, and vice versa. The validity of the power loss analysis has been verified by the simulation results.

Overmodulation Operation of SVM for NPC Type 3-Level Inverter (NPC형 3레벨 인버터의 공간벡터 과변조운전)

  • Lee, Jae-Moon;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.22-32
    • /
    • 2008
  • This paper proposes a linearization technique for the 3-level NPC type inverter, which increases the linear control range of Inverter up to the one-pulse inverter. The overmodulation range is divided into two modes depending on the Modulation Index, MI. In overmodulation region I, the reference angles are derived from the fourier series expansion of the reference voltage corresponding to the MI. In overmodulation region II, the holding angles are also derived in the same way. Therefore, it is possible to obtain the linear control and the maximized utilization of PWM inverter output voltage.

Investigations of Multi-Carrier Pulse Width Modulation Schemes for Diode Free Neutral Point Clamped Multilevel Inverters

  • Chokkalingam, Bharatiraja;Bhaskar, Mahajan Sagar;Padmanaban, Sanjeevikumar;Ramachandaramurthy, Vigna K.;Iqbal, Atif
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.702-713
    • /
    • 2019
  • Multilevel Inverters (MLIs) are widely used in medium voltage applications due to their various advantages. In addition, there are numerous types of MLIs for such applications. However, the diode-less 3-level (3L) T-type Neutral Point Clamped (NPC) MLI is the most advantageous due to its low conduction losses and high potential efficiency. The power circuit of a 3L T-type NPC is derived by the conventional two level inverter by a slight modification. In order to explore the MLI performance for various Pulse Width Modulation (PWM) schemes, this paper examines the operation of a 3L (five level line to line) T-type NPC MLI for various types of Multi-Carriers Pulse Width Modulation (MCPWM) schemes. These PWM schemes are compared in terms of their voltage profile, total harmonic distortion (THD) and conduction losses. In addition, a 3L T-type NPC MLI is also compared with the conventional NPC in terms of number of switches, clamping diodes, main diodes and capacitors. Moreover, the capacitor-balancing problem is also investigated using the Neutral Point Fluctuation (NPF) method with all of the MCPWM schemes. A 1kW 3L T-type NPC MLI is simulated in MATLAB/Simulink and implemented experimentally and its performance is tested with a 1HP induction motor. The results indicate that the 3L T-type NPC MLI has better performance than conventional NPC MLIs.

Output Voltage Harmonics Analysis of NPC Type Three-level Inverter (NPC형 3레벨 인버터의 출력전압 고조파 분석)

  • Kwon, Kyoung-Min;Choi, Jae-Ho;Chung, Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.472-480
    • /
    • 2009
  • This paper describes the overmodulative SVPWM technique and harmonics analyses of three phase NPC type three-level inverter to the modulation index. Three phase NPC type three-level inverter adopted SVPWM to extend the linear region to 0.907, moreover, the following voltage compensation using Fourier series was adopted in the region of overmodulation to make it work to six-step level. PD type of multi carrier method is used with the double Fourier series for the analysis of output power harmonics characteristic. Simulation was performed by PSIM, and the harmonics characteristics of 3-level inverter in each region are analyzed. The side band harmonics of carrier frequency are dominant in the linear region, but these harmonic components are decreased as the inveter goes to overmodulation region, and the harmonics due to the fundamental frequency is increased gradually at the same time. The harmonic analyses are verified through the simulation and experimental results under the same condition.

The Comparative analysis of Power Losses for 3-Level NPC Inverter and 3-Level T-type Inverter Module used in 10kW Photovoltaic system (10KW 급 태양광 발전용 3-Level NPC 인버터와 T-type 인버터 모듈의 손실 비교 분석)

  • Lee, Kwanghee;Jang, Seungyong;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.143-144
    • /
    • 2014
  • 본 논문에서는 NPC(Neutral Point Clamped) 및 T-type IGBT 모듈을 이용하여 3상 3-레벨 인버터를 구성하고, 인버터에서 발생되어지는 도통손실과 스위칭 손실을 PSIM의 Thermal Module을 사용하여 확인한다. 또한 토폴로지 상의 차이에 의해 발생되어지는 스위치 손실을 비교 하며, 시뮬레이션에 적용한 파라미터 값들을 수식에 직접 적용하여 손실에 영향을 미치는 파라미터를 확인하고, 각 파라미터의 값의 변화가 주어진 조건에서 전체 손실에 미치는 영향을 확인한다.

  • PDF

SVPWM Overmodulation Scheme of Three-Level Inverters for Vector Controlled Induction Motor Drives

  • Kwon, Kyoung-Min;Lee, Jae-Moon;Lee, Jin-Mok;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.481-490
    • /
    • 2009
  • This paper describes a SVPWM overmodulation scheme of NPC type three-level inverter for traction drives which extends the modulation index from MI=0.907 to unity. SVPWM strategy is organized by two operation modes of under-modulation and over-modulation. The switching states under the under-modulation modes are determined by dividing them with two linear regions and one hybrid region the same as the conventional three-level inverter. On the other hand, under the over-modulation mode, they are generated by doing it with two over-modulation regions the same as the conventional over-modulation strategy of a two level inverter. Following the description of over-modulation scheme of a three-level inverter, the system description of a vector controlled induction motor for traction drives has been discussed. Finally, the validity of the proposed modulation algorithm has been verified through simulation and experimental results.

NPC Type 3 Level Inverter Operation in Overmodulation Region (NPC형 3레벨 인버터 과변조영역운전)

  • Lee, Jae-Moon;Choi, Jae-Ho;Lee, Eun-Kyu;Yeom, Sang-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.194-197
    • /
    • 2007
  • This paper proposes a linearization technique for the 3 level NPC type inverter, which increases the linear control range of inverter up to the 6-step inverter. The overmodulation range is divided into two modes depending on the modulation index(MI), In mode I, the reference angles are derived from the Fourier series expansion of the reference voltage corresponds to the MI. In mode II, the holding angles are also derived in the same way. Therefore, it is possible to obtain the linear control and the maximized utilization of PWM inverter output voltage.

  • PDF

According to the operating mode analysis loss of 3-Level NPC Inverter and T-type Inverter used in offshore wind power (해상 풍력 발전용 3-Level NPC 인버터와 T-type 인버터의 동작방식에 따른 손실 분석)

  • Kim, Han-Soo;Kim, Jeong-Heon;Hong, Seok-Jin;Shin, Soo-Cheol;Lee, Jong-Moo;Won, Chung-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.421-422
    • /
    • 2013
  • 본 논문에서는 3-레벨의 NPC(Neutral Point Clamped) VSC와 T-type VSC를 시뮬레이션용 열 모델링 기법을 이용하여 스위칭과 도통 손실을 비교 분석하였다. 두 가지 토폴로지의 인버터동작과 회생동작에서의 주파수에 따른 효율을 시뮬레이션을 통하여 고찰 하였다.

  • PDF

Driving the induction motor of indirect vector control using the 3-level inverter in the overmodulation region (3-level인버터를 이용한 과변조영역에서의 간접벡터 유도전동기 구동)

  • Lee, Jae-Moon;Jung, Hun-Sun;Nho, Se-Jin;Lee, Eun-Kyu;Yeum, Sang-Kyu;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.403-405
    • /
    • 2007
  • This paper presents the over-modulation strategy and indirect vector control drive of NPC type PWM inverter. NPC inverter has three level phase voltage output.It can perform in high voltage through assembling switching components. It has less harmonics and surge voltage stress at motor terminals than the 2 level inverter in same switching frequency through 3 level voltage. The conventional railway vehicle has used the vector control to MI=0.907 and the slip-frequency control from MI=0.907 to six-step mode. The slip-frequency control has bad motive power and slow torque control response. But vector control has good motive power and can instant torque control. In this paper, output voltage is controlled linearly from linear region to six-step mode by using over-modulation strategy. And NPC inverter is used.

  • PDF

A Hybrid Active Power Filter for Electric-Railway Systems Using Multi-Level Inverters (멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동 전력필터)

  • 김윤호;김수홍;이강희
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.339-344
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 3rd harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.