• Title/Summary/Keyword: NOx Emission Factor

Search Result 70, Processing Time 0.021 seconds

Emission Characteristic for High Efficiency and Low NOx of Externally Oscillated Oil Burner (외부가진 오일 버너의 고효율 저 NOx 배출특성)

  • Kim, Seong-Cheon;Song, Hyoung-Woon;Chun, Young-Nam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.693-700
    • /
    • 2006
  • The important factor for the development of burner is the achievement of low emissions with maintaining combustibility. In case of maintaining high temperature flame and excess air to increase the combustibility, it is possible to achieve high combustion efficiency, due to the reduction of UHC(unborn hydrocarbon), carbon monoxide and soot. However, it is difficult to reduce the thermal NOx produced in the high temperature flame. To solve this problem, we developed externally oscillated oil burner which is possible for the high efficiency combustion and low NOx emission, simultaneously. The experiment of flame characteristics and NOx reduction were achieved according to the variation of frequency, amplitude and air velocity. Frequency, amplitude and air velocity are the most important parameter. The optimum operating conditions are frequency 1,900 Hz, amplitude 3 $V_{pp.}$ and air velocity 6.8 m/s. Reduction of NOx and CO are 47% and 22%, respectively.

A Study on the Estimation of Air Pollutants Emission Factors in Electric Power Plants (화력발전소의 대기오염물질 배출계수 산정 연구)

  • 김대곤;엄윤성;홍지형;이석조;석광설;이대균;이은정;방선애
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.281-290
    • /
    • 2004
  • The main purpose of this study was to characterize the air pollutants emission factors in electric power plant (EPP) using fossil fuels. The electric power plant is a major air pollution source, thus knowing the emission characteristics of electric power plant is very important to develop a control strategy. The major air pollutants of concern from EPP slacks are particulate matter (PM), sulfur oxides (SOx), nitrogen oxides (NOx), carbon monoxide (CO) and heavy metals. Throughout the study, the following results are estimated - PM : 8.671E-05 ∼ 8.724E+01 PM emission (kg) per fuel burned (ton) - SOx : 4.149E-04∼7.877E+01 SOx emission (kg) per fuel burned (ton) - NOx 1.578E-02∼9.857E+00 NOx emission (kg) per fuel burned (ton) - CO : 3.800E-04∼1.291E+00 CO emission (kg) per fuel burned (ton) - Hg : 1.220E+01∼3.108E+02 Hg emission (mg) per fuel burned(ton) From the statistical analysis by Wilcoxon signed ranks test between the emission factors of ours and U.S. EPA's, we can yielded that : p 〉0.05.

The study of combustion characteristics and emissions with the variation of design factor on slit gas burner (슬릿버너에서 형상변화가 연소특성 및 배기배출물에 미치는 영향)

  • Kim, Tae-Woo;Cho, Seung-Wan;Chang, Young-June;Jeon, Chung-Hwan
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.314-319
    • /
    • 2005
  • In this study, the combustion characteristics were investigated with the variation of design factors on multiple slit gas burner. The design factors consist of slit height, width, spacing, and inner length. The combustion characteristics were made analysis of the CO emission and NOx emission by using CO analyzer and NOx analyzer. The lower perimeter to area and the narrow spacing extends the lift-flame limit. The CO emission increases with the increasing perimeter to area ratio at the same condition. The NOx emission is found to be less significant with the port perimeter to area ratio. The flame interference might highly depend on the spacing and port perimeter to area ratio, and it also affects the burner performance.

  • PDF

Model and Field Testing of a Heavy-Duty Gas Turbine Combustor

  • Ahn, Kook-Young;Kim, Han-Seok;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.9
    • /
    • pp.1319-1327
    • /
    • 2001
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed 1:1 scale. The model experiments were executed at a lower pressure than that in a real gas turbine. Combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure and NOx emission were measured at partial and full loads for both model and on-site testing. The comparison of these items in the stand and field test results led to has the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

A Study on the Estimation of Emission Factors and Emission Rates for Motor Vehicles (자동차에 의한 오염물질 배출계수 및 배출량 산출에 관한 연구)

  • 조강래;엄명도;김종춘;홍유덕;김종규;한영출
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.69-77
    • /
    • 1993
  • Exhaust emissions are calculated as a product of the emission factor and the vehicle kilometer traveled(VKT). The emission factor is a function of several parameters such as vehicle model year, vehicle mileage, traffic conditions, etc. The representative driving cycles classified as ten different types of an average vehicle speed were selected by analyzing passenger car driving patterns in Seoul. 51 vehicles were sampled and analyzed by types of vehicles, fuels used, model years and vehicle mileages also, exhaust emissions of them were measured by chassis dynamometer. Regression equations between average vehicle speeds and exhaust emissions are made for the estimation of emission factors at different vehicle speeds. Annual emission rates of air pollutants from motor vehicles in Korea were 1116$\times10^3 ton, 149\times10^3 ton, 413\times10^3 ton and 67\times10^3$ ton for CO, HC, NOx and particulats, respetively in 1990. It was found that 56% of CO and 49% of HC were originated from passenger cars and taxis, in addition, 87% of NOx and 100% of particulates were from buses and trucks using diesel fuels.

  • PDF

A LCA Case Study on Basic Materials of PC (PC 구성물질에 관한 LCA 사례연구)

  • Lee, Sung-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.3
    • /
    • pp.10-17
    • /
    • 2005
  • In this paper, the life cycle assessment(LCA) methodology is applied to Personal Computer's basic materials in order to analyze the impact to the environment. LCA data collection is carried out taking into account on main materials of PC's parts and component. And the impact assessment is the environmental burden on three factor into air emission(CO2, SOx, NOx), five factor into water emission(BOD, COD, SS, N, P), and three factor on transported substance(cl, NH4, SO4). According to the result, the environmental burden of PC's basic materials was proved to be used total energy 6,285Mj and emitted CO2 259.8kg, SOx 3,571g, NOx 330g, COD 1,328g, P 246g, N 2,434g. And this paper was presented the problems of its disposition-incinerating, landfill, and recycling.

A Study on the Emission Factors of Air Pollutants for the Melting Furnaces of the Iron and Steel Industry (철강산업 용융로의 대기오염물질 배출계수 산정 연구)

  • 석광설;방선애;홍지형;이석조;김대곤;이대균;허정숙;이은정
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.571-578
    • /
    • 2004
  • The purpose of this study is to estimate of emission factors of the air pollutants for the melting furnaces for the iron and steel industry. The result of this study is able to obtaine the emission factor of particulate matters (PM), sulfur dioxide. nitrogen oxides for melting furnace. The emission factors of each pollutants were as follows : - the emission factor varied between 6.13E-03~6.12E-01 kg/ton for PM -1.59E-01~2.45E+00kg/ton for $SO_2$ - 6.82E-02~6.88E-01 kg/ton for NOx, respectively. Analysis of the differences in the emission factors of ours and U.S. EPA's yielded the following results for the Wilcoxon method : p>0.05. The statistical analysis showed no differences in the our emission factors and U.S. EPA's

A Study on the Target Values Fixing of Green Vehicle Emissions in Consideration of In-use Deterioration (운행차 열화특성을 고려한 제작차 배출가스 목표치 설정에 관한 연구)

  • 김현우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.104-110
    • /
    • 2003
  • As exhaust emission standards are more stringent, higher conversion efficiency of automotive catalytic converter is required. In addition, catalytic converter is deteriorated during mileage accumulation of vehicle. Therefore the specification of catalytic converter should be decided in consideration of emission standards and deterioration. Because the decision of the specification of catalytic converter is required at the beginning of vehicle development procedure, it is important and necessary to fix the target values of green vehicle exhaust emissions. To do this, a linear regression analysis was done with in-use exhaust emissions data of 5 different kinds of vehicle that received US94 emission standards certification, and data handling methods including some statistical estimation were proposed. As a result, the fixed target values of NMHC, CO, NOx of green vehicle against US94 emission standards were 0.079, 0.83, 0.116, respectively. And expected in-use deterioration factor of NMHC, CO, NOx were 1.75, 2.02, 1.38, respectively. And also it was blown that even if failure rate is 30% after 80,000km driven, it might be sufficiently safe from emission failure confirmatory test of Korea. It is hopeful to make a database of in-use emissions to increase the confidence in correctness of the calculated target values.

The influence of significant design factor on CO and NOx emission in gas cooktop burner (가스 쿡탑 버너에서 디자인 형상이 배기배출물에 미치는 영향)

  • Jeong, Yong-Ki;Kim, Yoong-Soo;Yang, Dae-Bong;Kim, Yang-Ho;Ryu, Jong-Wan;Wie, Jae-Hyug;Lim, Jae-Beom;Seok, Jun-Ho;Chang, Yoong-June;Jeon, Chung-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2192-2197
    • /
    • 2008
  • An experimental study was performed to investigate the effects of configuration of burner and air excess ratio on CO & NOx emission characteristics of the cooktop burners which are used extensively. In this study, the combustion characteristics were investigated with the variation of design factor of cooktop burners. The results showed that as the thermal input increases, flammable region go narrower. With the increase of loading height from the cap to grate, the CO emission decrease owing to the reduction of quenching by flame impingement on the load. Additionally, the CO emission increase with angle of main slot, however the NO emission is almost unaffected.

  • PDF

Development of Low NOx Combustor for 55kw Class Micro Gasturbine (55kW급 마이크로터빈용 저공해 연소기 개발)

  • Kim Hyung-Mo;Park Young-Il;Park Poo-Min;Yang Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.318-321
    • /
    • 2005
  • The design and performance test of a low NOx gas turbine combustor to be used in 55kW class micro-gasturbine engine was performed in KARI's combustion test facility. The combustor is reverse flow-can type for easy installation of injector and other parts and LNG is used as fuel. The performance targets are $99.5\%$ combustion efficiency, less 10ppm NOx, $30\%$ patten factor and $4\%$ pressure loss. Most of the performances required are satisfied.

  • PDF