• 제목/요약/키워드: NOM removal

검색결과 66건 처리시간 0.02초

갈수기 정수장운영관리 사례 - 갈수기 pH저감제(황산)투입에 의한 정수처리효율 향상 (Improvement of Water Treatment Efficiency by pH Decreasing Agent (H2SO4) for Droughty Seasons)

  • 가길현;김윤용;이준호;안치화;한인섭;민병대
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.415-422
    • /
    • 2008
  • Drinking water treatment is enhanced by coagulant dosages and chlorine injection because of pH increase in raw water in droughty seasons such as spring and fall. But water quality deterioration is occurred by increase in residual aluminium and disinfection by-products. Coagulation process can be used to control natural organic matter (NOM) during water treatment. The effect of coagulation process appeared to depend on the pH of water rather than coagulant dosages. In this study, for water treatment in high pH season $H_2SO_4$ was applied for pH adjustment at full scale. Before and after pH adjustment by $H_2SO_4$ injection, water quality of drinking water was evaluate. In the result of investigation of total organic carbon (TOC) removal in high pH season, TOC was removed approximately 30~40%, which showed decrease in water treatment efficiency. Also, it is increased both particle numbers and residual Al concentration in the water. After $H_2SO_4$ injection for adjustment to pH<7.5 in settled water, treated water turbidity decreased in 0.047 NTU from 0.059 NTU, and particle numbers of filtered water decreased in 20/mL from 90/mL. On the other side, TOC removal efficiency increased in approximately 10% after adjustment of pH. In the result of decrease in pH in raw water through more coagulants and prechlorine without $H_2SO_4$ injection, trihalomethanes (THMs) concentration increased in $16{\mu}g/L$ from $8{\mu}g/L$.

정수처리 공정에서 용존 유기물질 분류에 의한 haloacetic acid 생성능 평가 (Evaluation of Haloacetic Acid Formation Potential in Drinking Water Treatment Process by Fraction Technique)

  • 손희종;황영도;류동춘;정철우;이건;손형식
    • 한국환경과학회지
    • /
    • 제23권9호
    • /
    • pp.1655-1662
    • /
    • 2014
  • A comprehensive fractionation technique was applied to a set of water samples obtained along drinking water treatment process with ozonation and biological activated carbon (BAC) process to obtain detailed profiles of dissolved organic matter (DOM) and to evaluate the haloacetic acid (HAA) formation potentials of these DOM fractions. The results indicated that coagulation-sedimentation-sand filtration treatment showed limited ability to remove hydrophilic fraction (28%), while removal of hydrophobic and transphilic fraction were 57% and 40%, respectively. And ozonation and BAC treatment showed limited ability to remove hydrophobic fractions (6%), while removal of hydrophilic and transphilic fractions were 25% and 18%. The haloacetic acid formation potential (HAAFP)/dissolved organic carbon (DOC) of hydrophilic fraction was the highest along the treatment train and HAAFP/DOC of hydrophilic fraction was higher than hydrophobic and transphilic fraction as 23%~30%, because of better removal for hydrophobic fraction both in concentration and reactivity.

정수처리를 위한 전오존-세라믹 막여과 조합공정에 관한 연구(I) : 망간 제거 중심 (Study of a hybrid process combining ozonation and ceramic membrane for drinking water treatment (I) : manganese removal)

  • 진광호;임재림;이경혁;왕창근
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.633-640
    • /
    • 2008
  • In this research, the $3.6m^3/day$ scale pilot plant consisting preozonation, coagulation, flocculation, and ceramic membrane processes was operated for long term period to evaluate the validity of ceramic membrane filtration process for treating lake water containing high concentration manganese. The higher concentration of dissolved manganese($Mn^{2+}$) was effectively oxidized to the bigger insoluble colloidal manganese ($MnO^2$) by 1~2 mg/L ozone. The colloidal manganese reacted with coagulant (poly aluminium chloride, PAC) and then formed the big floc. Ceramic membrane rejected effectively manganese floc during membrane filtration. Dissolved organic carbon(DOC) removal was dependent upon $Mn^{2+}$ concentration. While average $Mn^{2+}$ concentration was 0.43 and 0.85 mg/L in raw water, DOC removal rate in preozonation was 26.5 and 13.5%, respectively. The decrease rate of membrane permeability was faster without preozonation than with preozonation while membrane fouling decreased with NOM oxidation by ozone. In conclusion, raw water containing high concentration of manganese can be effectively treated in preozonation-coagulation-ceramic membrane filtration system.

혼합응집제에 의한 자연유기물질 제거에 미치는 영향 인자 (Influencing Factors on NOM Removal using Blended Coagulants)

  • 명복태;우달식;최종헌;문철훈;이윤진;조영태;조관형;남상호
    • 환경위생공학
    • /
    • 제16권3호
    • /
    • pp.96-103
    • /
    • 2001
  • This study was carried out to investigate the major factors for the removal of NOMs (Natural Organic Matters) by alum ferric chloride and blended coagulants that consisted of alum and ferric chloride. Investigated factors were pH, the dosage of coagulant, alkalinity, hardness and bloc strength. The particle size contained in the test water came from the Han River was also measured. DOC(Dissolved Organic Carbon) removal at pH 6 was two to three times higher than at pH 8.5. The blended coagulant showed 9 to 10 percent higher DOC removal efficiency and 2 to 4 percent higher turbidity under the same condition. Alkalinity consumption of alum, ferric chloride and blended coagulant was 81%, 90% and 86% of theoretical value, respectively. The limit concentration of alkalinity to avoid pin floe was 10 mg $CaCO_3/L$ when alum was used. Hardness had no apparent effect on coagulation. The residual turbidity and $UV_{254}$ showed a tendency of increasing with floc strength($sec^{-1}$) increase. The order of floe strength was the following; alum >blended coagulant > ferric chloride. The particle counter test showed 89 percent of the small particle size(SPS, $1~5{\;}{\mu}textrm{m}$) and 11 percent of the medium to large particle size(M.LPS, $5~125{\;}{\mu}textrm{m}$). At PH7.85, the particle removal efficiencies of SPS($1~5{\;}{\mu}textrm{m}$) and M.LPS($5~125{\;}{\mu}textrm{m}$) in the coagulation process were 81% and 95%, respectively.

  • PDF

정수처리에서 pH 저감에 의한 응집효율향상에 관한 연구 (Improving Coagulation Performance with pH Preadjustment in Drinking Water Treatment)

  • 이환;이철효;정창규;이윤진
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.1-6
    • /
    • 2003
  • This paper reports on a pilot scale comparison of PACS coagulation with and without pH preadjustment. The pH of the water was adjusted with carbon dioxide and sulfuric acid. Process performance was assessed on the basis of total organic carbon(TOC), UV absorbance, turbidity and disinfection by-product(DBP) precursors. Coagulation pH appeared to be a determining factor for maximum NOM removal. The optimum coagulation pH in order to decrease TOC and turbidity were pH 7. Preadjustment of pH 7 increased TOC removal to as much as 43, 47 percent with sulfuric acid and carbon dioxide. Moreover, coagulation at pH 7 caused a reduction in UV$_{254}$, THMFP and HAAFP compared to the baseline coagulation. For preadjustment of pH 7 with carbon dioxide, the percentage of TOC, UV$_{254}$, THMFP and HAAFP shows the reduction rate of 3.8, 0.5, 4.8, 9.4% comparing to the coagulation rendition using sulfuric acid. Acid addition to depress pH during coagulation decrease Langelier Saturation Index(LSI), potentially causing increase corrosion in water distribution systems. LSI for carbon dioxide and sulfuric acid at pH 6 was -2.3, -3.3. Therefore, carbon dioxide was more effective at controlling corrosion than sulfuric acid.

낙동강 원수를 대상으로 Al염계 및 Fe염계 응집제를 이용한 고도응집의 적용 (Application of Enhanced Coagulation for Nakdong River Water Using Aluminium and Ferric Salt Coagulants)

  • 문신득;손희종;염훈식;최진택;정철우
    • 대한환경공학회지
    • /
    • 제34권9호
    • /
    • pp.590-596
    • /
    • 2012
  • 고도응집 공정은 DBP 전구물질인 NOM을 제거하는 최적기법이다. 본 연구에서는 낙동강 원수를 대상으로 $FeCl_3$, alum, PSOM 및 PACl 응집제를 대상으로 고도응집 공정의 적용시 가장 효과적인 응집제와 응집조건을 DOC, THMFP, HAAFP 및 제타전위 변화를 중심으로 평가하였다. 탁도 제거율은 고도응집을 적용시 기존응집에 비해 제거율의 상승은 없었으며, 일정 응집제 주입량 이상에서는 제거율이 더욱 저하되었으나 DOC, THMFP 및 HAAFP 제거율은 응집제 종류별로 기존응집에 비해 각각 13~18%, 9~18% 및 9~18% 정도 증가하였다. 응집 pH 변화에 따른 탁도 제거특성은 $FeCl_3$와 PACl이 pH 4~10 범위에서 비교적 높은 탁도 제거율을 나타내었고 alum과 PSOM의 경우는 pH 5~8의 범위에서 안정적인 제거율을 나타내었다. DOC는 4종의 응집제 모두 pH 5~7 범위에서 안정적인 제거율을 나타내었다. 고도응집 공정을 적용시 1 kDa 이하 및 10 kDa 이상의 용존 유기물질의 제거율은 각각 11~21% 및 16% 정도 기존응집 공정에 비해 증가하였으며, 소수성 및 친수성 유기물질의 제거율은 각각 27~38% 및 11~15% 정도 증가하였다. 낙동강 원수의 고도응집에 가장 효과적인 응집제로는 $FeCl_3$로 나타났으며, 다음으로 PSOM, PACl 및 alum 순이었다.

막분리(NF, UF)를 이용한 자연유기물(NOM) 제거에 관한 연구(II) - NF, UF 운전특성과 HAA생성능 제거 -

  • 송양석;박용훈;조영관;조재원;박돈희
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XII)
    • /
    • pp.334-338
    • /
    • 2003
  • 막분리 공정을 모형시설에 도입 후 약 2년간에 걸쳐 막의 구성을 달리하여 운영하였으며, 원수 및 처리수의 수질특성을 조사하였다. 원수의 수질특성은 친수성 물질이 53%, 소수성 물질 28% 나머지는 반친수성물질로 구성된 것으로 조사되었으며, UF 및 NF 처리수의 분자량 분포를 조사한 결과 원수와 달리 큰 분자량을 갖는 부분이 제거된 것을 볼 수 있었다. UF와 NF의 막분리 공정운전 결과를 종합해 본 결과, UF막인 GH(2500Da)와 GM(8000Da) 경우 GM이 생산량 및 운전특성에서 GH에 비해 우수한 결과를 보여 주었으며, NF막인 HL$(150{\sim}300Da)$과 GM의 비교 운전한 결과 NF막인 HL의 유기물 제거 효과가 우수한 것을 보여 주고 있다. 그러나 UF막인 GM의 경우 MWCO가 8000Da로 NF막인 HL에 비해 큼에도 불구하고 유기물 제거 면에서 상당히 우수한 유기물 제거 효과를 보여 주었으며, 소독부산물의 생성능 평가에서도 50%이상의 양호한 제거 효과를 보여 주었다.

  • PDF

Removal of Perchlorate Using Reverse Osmosis and Nanofiltration Membranes

  • Han, Jonghun;Kong, Choongsik;Heo, Jiyong;Yoon, Yeomin;Lee, Heebum;Her, Namguk
    • Environmental Engineering Research
    • /
    • 제17권4호
    • /
    • pp.185-190
    • /
    • 2012
  • Rejection characteristics of perchlorate ($ClO_4^-$) were examined for commercially available reverse osmosis (RO) and nanofiltration (NF) membranes. A bench-scale dead-end stirred-cell filtration system was employed to determine the toxic ion rejection and the membrane flux. Model water solutions were used to prepare $ClO_4^-$ solutions (approximately, $1,000{\mu}g/L$) in the presence of background salts (NaCl, $Na_2SO_4$, and $CaCl_2$) at various pH values (3.5, 7, and 9.5) and solution ionic strengths (0.001, 0.01, and 0.01 M NaCl) in the presence of natural organic matter (NOM). Rejection by the membranes increased with increasing solution pH owing to increasingly negative membrane charge. In addition, the rejection of the target ion by the membranes increased with increasing solution ionic strength. The rejection of $ClO_4^-$ was consistently higher for the RO membrane than for the NF membrane and $ClO_4^-$ rejection followed the order $CaCl_2$ < NaCl < $Na_2SO_4$ at conditions of constant pH and ionic strength for both the RO and NF membranes. The possible influence of NOM on $ClO_4^-$ rejection by the membranes was also explored.

가압펌프에 의해 해체된 플럭이 가압식 막여과 공정의 제거효율 및 막오염에 미치는 영향 (Effect of Coagulated Flocs Broken by the Pressure Pump on Removal Rate and Membrane Fouling of Pressurized MF process)

  • 김준현;문백수;박종수;조윤호;김진호
    • 멤브레인
    • /
    • 제23권6호
    • /
    • pp.460-468
    • /
    • 2013
  • 가압식 MF공정의 전처리공정으로 침전지가 없는 혼화/응집공정에서 적정응집제 투입농도선정 및 유기물 제거성능을 평가하였다. 전처리 공정에서 생성된 플럭이 가압펌프의 임펠러에 의해 해체됨을 확인하였으며 원수탁도가 10 NTU 이하로 유입이 될 때, 혼화/응집조와 펌프후단에서 플럭형성을 위한 최적응집제 투입량은 4 mg/L (as PACl 17%)이었다. 이때의 DOC 제거율은 평균 43%이었으며, 응집제투입량을 계속적으로 증가시켜 8 mg/L (as PACl 17%)로 투입을 하였을 때, DOC 제거율은 평균 48%를 나타내어 제거율은 크게 개선되지 않았다. 전처리가 없는 PVDF 가압식 MF공정의 TMP는 0.54 bar에서 운영이 되었으며, 혼화/응집 전처리 공정을 적용하여 운영 시 TMP는 0.41 bar로 안정적인 운영이 가능하였다.

펄스 UV 램프를 이용한 미생물 소독 및 2-MIB 제거 특성 (Characteristics of Disinfection and Removal of 2-MIB Using Pulse UV Lamp)

  • 안영석;양동진;채선하;임재림;이경혁
    • 상하수도학회지
    • /
    • 제23권1호
    • /
    • pp.69-75
    • /
    • 2009
  • The characteristics of disinfection and organic removal were investigated with pulse UV lamp in this study. The intensity and emission wavelength of pulse UV Lamp were compared with low pressure UV lamp. The emission spectrum range of pulse UV lamp was between 200 and 400 nm while the emission spectrum of low pressure UV lamp was only single wavelength of 254nm. 3 Log inactivation rate of B. subtilis spore by pulse UV and low pressure UV irradiation was determined as $44.71mJ/cm^2$ and $57.7mJ/cm^2$, respectively. This results implied that wide range of emission spectrum is more effective compared to single wavelength emission at 254nm. 500ng/L of initial 2-MIB concentration was investigated on the removal efficiency by UV only and $UV/H_2O_2$ process. The removal efficiency of UV only process achieved approximately 80% at $8,600mJ/cm^2$ dose. 2-MIB removal rate of $UV/H_2O_2$ (5 mg/L $H_2O_2$) process was 25 times increased compared to UV only process. DOC removal efficiency for the water treatment plant effluent was examined. The removal efficiency of DOC by UV and $UV/H_2O_2$ was no more than 20%. Removal efficiency of THMFP(Trihalomethane Formation Potential), one of the chlorination disinfection by-products, is determined on the UV irradiation and $UV/H_2O_2$ process. Maximum removal efficiency of THMFP was approximately 23%. This result indicates that more stable chemical structures of NOM(Natural Organic Matter) than low molecule compounds such as 2-MIB, hydrogen peroxide and other pollutants affect low removal efficiency for UV photolysis. Consequently, pulse UV lamp is more efficient compared to low pressure lamp in terms of disinfection due to it's broad wavelength emission of UV. Additional effect of pulse UV is to take place the reactions of both direct photolysis to remove micro organics and disinfection simultaneously. It is also expected that hydrogen peroxide enable to enhance the oxidation efficiency on the pulse UV irradiation due to formation of OH radical.