• Title/Summary/Keyword: NO Removal

Search Result 2,602, Processing Time 0.028 seconds

An Experimental Study on Effect of Plasma for Exhaust Emissions in Small High-Speed Diesel Engine (소형 고속 디젤엔진의 배기 배출물에 미치는 플르즈마의 영향에 관한 실험적 연구)

  • 백태실
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.755-760
    • /
    • 1999
  • To remove nitrogen oxides(NOx) in exhaust gas of diesel engine three-way catalytic process with plasma discharger has great possibilities. Characteristics of NOx removal depends on NO conver-sion to $NO_2$ and /or $HNO_3$ due to high activation energies for NO oxidation and reduction, NOx removal efficiency by using three-way catalytic with plasma discharger indicated about 50% at 40watt power consumption condition.

  • PDF

An Experimental Stduy on NOx Reduction in Exhaust Gas from Diesel Engine with Plasma (플라즈마를 이용한 디젤엔진 배기가스 중의 NOx 저감에 관한 실험적 연구)

  • 조기현;황의현
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.83-90
    • /
    • 1999
  • To remove nitrogen oxides(NOx) in exhaust gas of diesel engine, three-way catalytic process with plasma discharger has great possbilities. Characteristics of NOx removal depends on NO conversion to $NO_2$ and/or $HNO_3$ due to high activation energies for NO oxidationand reduction. NOx removal efficiency by using three-way catalytic with plasma dischager indicated about 50% at 40 watt power consumption condition.

  • PDF

Generation Characteristics of Ozone and NOx and Particle Removal in the Electrostatic Precipitators (코로나 방전 방식에 따른 전기집진기의 오존, NOx 발생 및 입자제거 특성)

  • Noh, Kwang-Chul;Lee, Young-Ho;Oh, Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1442-1449
    • /
    • 2003
  • We investigated the amount of the toxic gases emitted from the Electrostatic Precipitators(ESPs), which are currently used as the indoor air cleaners. The existing wire-to-plate(WTP) and neddle-to-plate(NTP) types of ESP designs are considered as the experimental corona dischargers. Using the voltage, the polarity of wire, the number of needles of NTP as the input variables, we studied the generation characteristics of ozone and $NO_{x}$ and the particle removal efficiency in the ESPs. As the results, we found out that the concentration of ozone, $NO_{2}$ and $NO_{x}$ is increased with increasing the voltage and the number of needles, but the amount of NO is decreased. And we observed that the generation rates of ozone and $NO_{x}$ are mainly related with the corona region through the photographs. Finally the experimental results showed that the particle removal efficiency of ESP with WTP type charger is more superior to that with NTP type chargers at the same voltage.

NO Oxidation using Non-Thermal Plasma and NOx removal by NaOH-Water Solution Shower (비열플라즈마에 의한 NO의 산화와 NaOH 샤워해 의한 NOx의 제거특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Kim, Ick-Kewn;Park, Sang-Hyun;Koh, Hee-Seok;Lee, Duck-Chool
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.947-949
    • /
    • 1998
  • In this paper, the NO was oxidized $NO_2$ by using the non-thermal plasma and NOx removal characteristics were measured by showering NaOH water-solution to $NO_2$. The NO oxidation increased in the order of DC, AC, and Pulse. NOx oxidation for two stage with applied voltage was better than that for one stage with applied voltage. NO oxidation didn't depend on applied voltage. While NO oxidation was going on, NOx removal efficiency was 20-25%, however, significantly depended on the injection method of air and $H_2O$ + air. When NaOH water-solution density of 20% was showered to flue gases, NOx removal efficiency increased to 64%.

  • PDF

Simultaneous removal of $SO_X$ and $NO_X$ by wet scrubber at small and medium craft (중소형 선박의 $SO_X/NO_X$ 동시제거를 위한 습식세정시스템)

  • Cha, Yu-Joung;Lee, Ju-Yeol;Ha, Tae-Young;Park, Byung-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.159-166
    • /
    • 2014
  • In recent years, researchers have put a considerable effort to decrease the emission of harmful gaseous pollutants to the atmosphere. In order to remove simultaneously $SO_2$ and $NO_X$ from the flue gas of small and medium-sized ship, we designed minimal wet scrubber inside a compact multistage modular system. In this study we proceed experiment of elemental technology at each stage of the scrubber. The each stage is oxidation of NO which is the main component of $NO_X$, and removal of $SO_2$, respectively. $NaClO_2$ was used to oxidize NO gas, and NaOH was used to remove $SO_2$ gas. The maximum NO conversion efficiency and the $SO_2$ removal efficiency are both indicate 100%.

Characteristic of do-$NO_x$ for $BaTiO_3$ - sludge hybrid packed bed type reactor ($BaTiO_3$ - sludge hybrid packed bed형 반응기에서 $NO_x$제거특성)

  • Park, Jae-Yoon;Koh, Hee-Suk;Park, Sang-Hyun;Song, Won-Sub;Lee, Jae-Dong;Son, Sung-Do;Lee, Hyung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2053-2056
    • /
    • 2000
  • The experiment on characteristic of $NO_x$ removal for $BaTiO_3$-sludge hybrid packed bed type reactor was conducted. Gas flow rate was 5(${\ell}/min$) and NO concentration was 50, 100 and 150(ppm). The effect on volume percent of $BaTiO_3$ to sludge was investigated, sludge pellets was added to $BaTiO_3$ pellets to increase $NO_x$ removal rate. In the result, when sludge pellets was added, NO removal rate of $BaTiO_3$ - sludge hybrid type was increased from 90.6% to 95%. However $NO_2$ decreased from 88ppm to 10ppm. $O_3$ decreased from 77ppm to 2ppm. $NO_x$ removal rate was increased to 74%.

  • PDF

Removal Characteristics of Nitrogen Oxide in Electromagnetic-Catalytic Plasma Reactor (전자계-촉매형 플라즈마 반응기의 질소 산화물 제거 특성)

  • 이현수;박재윤;이동훈;한병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.7
    • /
    • pp.640-648
    • /
    • 2002
  • This study is to develop electromagnetic-catalyst application plasma reactors for indoor air purification. Nitrogen Oxide(NOx) removal characteristics are measured in the electromagnetic catalyst application plasma reactors with various parameters and the effect of catalyst or/and magnetic field are investigated on the NOx removal. And AC or DC high voltage is applied for corona discharge, flow rates are 150~1500 $\ell/min$ and NO initial concentration is about 10 ppm. $Mn0_2$ and $TiO_2$ catalysts to increase NOx removal rate are used. In the results, NOx removal rate by AC power is about 10 % higher than that by DC power under the experimental condition of 700 $\ell/min$, 5 magnets, $MnO_2$ and $Ti)_2$ catalysts. When magnet is applied to the reactor, NOx removal rate increased. Also, the reactor with $MnO_2$ and $Ti)_2$ catalyst and magnet have the best removal rate.

Comparison of Seasonal Nitrogen Removal by Free-Water Surface Wetlands Planted with Iris pseudacorus L. (노랑꽃창포 자유수면습지의 계절에 따른 질소제거 비교)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.1
    • /
    • pp.121-132
    • /
    • 2011
  • Removal rates of $NO_3$-N and TN in the free-water surface wetland system during winter; December, January, February and March, spring and fall; April, May, October and November, and summer; Jun, July, August and September were investigated. The system was established on floodplain in the downstream reach of the Gwangju Stream in 2008. It measures 50 meters in length and 5.5 meters in width. Iris pseudacorus L. grown in pots for about two years were planted in the system. The water stream was funneled in by gravity and its effluent was discharged back in. Volumes and water quality of inflow and outflow were analyzed from December 2008 to November 2010. The inflow was averaged approximately 350 $m^3/day$ and hydraulic residence time was about 3 hours. Average influent and effluent $NO_3$-N concentration was 3.75 and 3.35 mg/L, respectively and $NO_3$-N retention was amounted to 10.6%. Influent and effluent TN concentration were averaged 4.93 and 4.30 mg/L, respectively and TN abatement reached to 12.9%. One-way ANOVA statistics claimed that the average removal rates of $NO_3$-N and TN during winter, spring and fall, and summer were not always the same (p<0.001). The t-Tests of three pairs among $NO_3$-N removal rates of winter, spring and fall, and summer illustrated that the removal rates of winter ($5.04{\pm}1.94$), spring and fall ($10.53{\pm}2.24$), and summer ($18.61{\pm}2.26$) were significantly different each others (p<0.001). Among TN removal rates, the three pairs of t-Tests of three seasons showed that the removal rates of winter ($5.21{\pm}2.51$), spring and fall ($11.71{\pm}3.12$), and summer ($21.53{\pm}4.86$) were significantly different from each others (p<0.001).

Growth and N, P removal efficiency of Chlorella vulgaris according to the nitrogen sources and pH condition (질소원 및 pH 조절빈도에 따른 Chlorella vulgaris의 성장특성 및 하수고도처리능 평가)

  • Han, Su-Hyun;Kim, Sun-Jin;Kim, Tae-Hyeong;Cho, Ki-Ju;Lee, Yunhee;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.833-840
    • /
    • 2012
  • This study aimed to investigate growth rate and nutrient removal efficiency of Chlorella vulgaris according to nitrogen sources and frequency of pH adjustment. Nitrogen and phosphorus removal efficiencies were evaluated in the three different conditions using $NO_3{^-}$, $NH_4{^+}$ as a sole nitrogen source and mixed condition. Initial nutrient concentrations in artificial wastewater were 30 mg-N/L and 3 mg-P/L similar to secondary wastewater effluent. When nitrogen source was $NO_3{^-}$, there was no inhibition on the growth of C. vulgaris with adjusting pH every 24 hr while growth inhibition occurred with $NH_4{^+}$ caused by pH drop. N, P removal efficiencies were no significant depending on the nitrogen sources. As pH was adjusted to 7 by pH-stat, growth rate and nutrient removal efficiencies were increased compared to adjusting pH every 24 hr, however, growth rate and nutrient removal efficiencies were no significant depending on the nitrogen sources.

Piggery Waste Treatment using Partial Nitritation and Anaerobic Ammonium Oxidation (부분질산화와 혐기성 암모늄산화를 이용한 돈사폐수처리)

  • Hwang, In-Su;Min, Kyung-Sok;Lee, Young-Ok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.599-604
    • /
    • 2006
  • Nitrogen removal with the combined SHARON (Single reactor system for high ammonium removal over nitrite)ANAMMOX (Anaerobic ammonium oxidation) process using the effluent of ADEPT (Anaerobic digestion elutriated phased treatment) slurry reactor with very low C/N ratio for piggery waste treatment was investigated. For the preceding SHARON reactor, ammonium nitrogen loading and removal rate were $0.97kg\;NH_4-N/m^3_{reactor}/day$ and $0.68kg\;NH_4-N/m^3_{reactor}/day$ respectively. In steady state, bicarbonate alkalinity consumption for ammonium nitrogen converted to $NO_2-N$ or $NO_3-N$ was 8.4 gram per gram ammonium nitrogen. The successive ANAMMOX reactor was fed with the effluent from SHARON reactor. The loading and removal rate of the soluble nitrogen defined as the sum total of $NH_4-N$, $NO_2-N$ and $NO_3-N$ in ANAMMOX reactor were $1.36kg\;soluble\;N/m^3_{reactor}/day$ and $0.7kg\;soluble\;N/m^3_{reactor}/day$, respectively. The average $NO_2-N/NH_4-N$ removal ratio by ANAMMOX was 2.41. Fluorescence in situ hybridization (FISH) analysis verified that Candidatus Kuenenia stuttgartiensis were dominate, which means that they played an important role of nitrogen removal in ANAMMOX reactor.