• Title/Summary/Keyword: NIR channel

Search Result 23, Processing Time 0.021 seconds

Development of a Transcutaneous Optical Information Transmission System for Total Artificial Heart Using Near Infrared Laser

  • Lee, Jung-Hoon;Kim, Wook-Eun;Choi, Jong-Hoon;Ahn, Jae-Mok;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.64-67
    • /
    • 1997
  • In the total artificial heart(TAH), a transcutaneous information transmission system(TITS) is vely important to monitor the TAH status and detect the device failure, and repair the possible problems. First of all, the communication channel(skin) and method were simulated in terms of transmittance, scattering, reflection and absorption, then the system was designed with size reduction including low power consumption and reliability compared to the previous one. The informations are transmitted through the skin(approximately 1cm in depth) by frequency modulated near infrared(NIR) pulses using 780nm laser diodes as transmitters and photodiode as receiver with high speed and high spectral sensitivity. The logic high and low frequencies are 3MHz, 1MHz respectively. The system is a bidirectional data link for more than 38.4Kbps data rate, full-duplex with a bit error rate of less than $10^{-5}$.

  • PDF

Neuro-scientific Approach to Fashion Visual Merchandising -Comparison of Brain Activation to Positive/Negative VM in Fashion Store Using fNIRS- (패션 비주얼머천다이징의 뇌 과학적 접근 -fNIRS를 이용한 패션매장의 긍정적/부정적 VM에 대한 뇌 활성 비교-)

  • Kim, Hyoung Suk;Lee, Jin Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.2
    • /
    • pp.254-265
    • /
    • 2017
  • This study examines the possibility of a neuro-scientific approach to fashion Visual Merchandising (VM), by researching the brain activation of customers about fashion stores in terms of VM. Study subjects were in 20's-30's residing in Busan and ten ordinary person or fashion industry related individuals, it measures the change of cerebral blood flow on positive/negative photo stimulus in terms of VM using a functional Near Infrared Spectroscopy (fNIRS) device, and then compared the brain activation to the difference of the fashion store VM. Photo stimuli utilized in the experiment were selected through a preliminary study in advance. The results of this study are as follows. First, the brain activation was found in all 16 channels of stimulus ranges of fashion store VM regardless of positive/negative stimulus. This means that the VM of fashion store causes changes to the cerebral blood flow of consumers, which implies that consumer behavior can be affected by store VM. It also shows that the brain is more active in negative VM stimulus than positive VM despite slight differences in the subjects. In terms of VM, this suggests that the negative factors of fashion stores have a greater effect on the brains of consumers compared to the positive factors. Second, the reaction of the brain channel is different according to the positive/negative VM stimulus of the fashion store by product group and confirms that positive/negative VM stimulus can be distinguished by brain-reaction for the three product groups except for the underwear group among four product groups (men's wear store, women's wear store, underwear store, and sportswear store). The results indicate that more objective scientific measure and decision-making are possible through neuro-science in the strategic execution of VM. This study verified the possibility for a neuro-scientific approach to fashion VM; therefore, there are expectations for the various activation of interdisciplinary research and subsequent development of VM that utilize neuroscience in fashion marketing.

Experiment of KOMPSAT-3/3A Absolute Radiometric Calibration Coefficients Estimation Using FLARE Target (FLARE 타겟을 이용한 다목적위성3호/3A호의 절대복사 검보정 계수 산출)

  • Kyoungwook Jin;Dae-Soon Park
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1389-1399
    • /
    • 2023
  • KOMPSAT-3/3A (K3/K3A) absolute radiometric calibration study was conducted based on a Field Line of sight Automated Radiance Exposure (FLARE) system. FLARE is a system, which has been developed by Labsphere, Inc. adopted a SPecular Array Radiometric Calibration (SPARC) concept. The FLARE utilizes a specular mirror target resulting in a simplified radiometric calibration method by minimizing other sources of diffusive radiative energies. Several targeted measurements of K3/3A satellites over a FLARE site were acquired during a field campaign period (July 5-15, 2021). Due to bad weather situations, only two observations of K3 were identified as effective samples and they were employed for the study. Absolute radiometric calibration coefficients were computed using combined information from the FLARE and K3 satellite measurements. Comparison between the two FLARE measurements (taken on 7/7 and 7/13) showed very consistent results (less than 1% difference between them except the NIR channel). When additional data sets of K3/K3A taken on Aug 2021 were also analyzed and compared with gain coefficients from the metadata which are used by current K3/K3A, It showed a large discrepancy. It is assumed that more studies are needed to verify usefulness of the FLARE system for the K3/3A absolute radiometric calibration.