• Title/Summary/Keyword: NIOSH method

Search Result 122, Processing Time 0.022 seconds

Application of NIOSH Lifting Equation to Analysis of Workload for Patients Transferring by Physical Therapist: a Case Study (물리치료사의 환자 운반 시 작업 부하 분석에 NIOSH 들기 공식 적용: 사례연구)

  • Lee, In-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.3
    • /
    • pp.119-124
    • /
    • 2009
  • Purpose: The National Institute for Occupational Safety and Health (NIOSH) lifting equation (NLE) is a useful tool to ergonomically analyze a workload. The NLE has high reliability and it can assess tasks by analyzing the work process. The purpose of this case study was to try using the NLE to analyze the workload of transferring patients by physical therapists in the hospital setting. Methods: We observed a physical therapist (PT) transferring patients from a wheelchair to a tilt table and a therapeutic table in one day. Two types of patient transferring methods were evaluated; (1) the manual single person method of stand, pivot and transfer, and (2) manual two person lifting under the thigh and grasping the waist for totally dependent patients. Results: The NIOSH lifting indexes of a person grasping the waist during the manual two person lifting were 5.52~4.48 according to the patient's weight. The NIOSH lifting indexes were 3.34 and 4.48 for the tasks performed by the manual single person method. Conclusion: Because transferring patients is not done very frequently, patients transferring tasks by a PT are not included as one of the musculoskeletal disorder related risky work criteria of the Korea Ministry of Labor. But the NIOSH lifting indexes of a person grasping the waist during the manual two person lifting and the manual single person method were over the NIOSH recommended weight limit threshold.

  • PDF

Assessment of total is ocyanates by OSHA and NIOSH analytical methods : accuracy and precision and airborne concentrations by process (NIOSH와 OSHA 측정 방법을 이용한 이소시아네이트류 발생 공정별 농도 분포 평가)

  • Kang, Hyoung Kyoung;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.1-18
    • /
    • 1999
  • The purpose of this study was to compare performances of two analytical methods, the OSHA 42 and the NIOSH 5522, of quantifying total isocyanates in air. These methods were compared in terms of accuracy and precision and the detection limits using four(4) spiked samples in each of four(4) concentration levels which ranged from 0.25 to 2.0 times of the ACGIH TLV-TWA. In addition, two methods were used to as sess airborne concentrations of total isocyanates at the following processes including autobody spray painting, furniture spray painting, polyurethane foaming, urethane adhesion, UV coating, and pigment mixing. The results of this study showed that the NIOSH 5522 method was better than the OSHA 42 method in terms of accuracy, precis ion, and detection limit for quantifying airborne total isocyanates. It was also clear that the NIOSH method was capable of detecting not only monomeric but also non-monomeric isocyanates. The results of air concentrations of total isocyanates among processes studied indicate that some processes may exceed the recommended level of isocyanates. In addition, to evaluate toxicological effects of total isocyanates, it is recommended to consider additive effects of isocyanates present in mixtures.

  • PDF

Field Validation of a Sampling and Analytical Method Developed for Preventing Airborne Hexavalent Chromium Collected on PVC Filter from Reduction (PVC 여과지에서의 환원 방지를 위해 개발된 공기중 6가 크롬 측정방법의 현장 평가)

  • 신용철;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.109-116
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of airborne hexavalent chromium, Cr(Ⅵ), in a field plating operation. The procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute iota Occupational Safety and Health (NIOSH) Method 7600, and the filler sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(Ⅵ) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(Ⅵ) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(Ⅵ) on PVC filters and storing the sample filters in strew-capped vials according to the NIOSH method, and analyzing Cr(Ⅵ) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(Ⅵ) into 0.02 M NaHCO₃ solution in midget impinger, and analyzing the Cr(Ⅵ) in samples using IC/VS. The third method was the OSHA Method ID-215. Using these four different methods, lour replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r²:0.99) between Cr(Ⅵ) concentrations measured by the Shin & Paik's Method and an impinger method (p>0.05). However, Cr(Ⅵ) concentrations determined by Shin & Paik's Method were significant1y different from those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(Ⅵ) concentrations of Shin & Paik's Method were significantly higher than those of the NIOSH/EPA Method or the OSHA method. This result indicated that the Shin & Paik's Method may prevent Cr(Ⅵ) losses caused by reduction and give more reliable results of airborne Cr(Ⅵ) concentrations in work environments.

Field Validation of an IC/Visible Spectrophotometry Method for the Determination of Cr(VI) in Mist (미스트중 6가 크롬 측정을 위한 IC/Visible Spectrophotometry 방법 (Shin & Paik′s Method)의 현장 평가)

  • 신용철;백남원;김상우;김선자;이유미
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.40.1-43
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of hexavalent chromium, Cr(VI) in mist from field plating operation. The Procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute for Occupational Safety and Health (NIOSH) Method 7600, and the filter sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(VI) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(VI) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(VI) on PVC filters and storing the sample filters in screw-capped vials according to the NIOSH method, and analyzing Cr(VI) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(VI) into 0.02 MN/sub a/Hco₃ solution in midget impinger, and analyzing the Cr(VI) in samples using IC/VS. The third method was the OSHA Method Id-215. Using these four different methods, four replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and Paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r/sup 2/=0.99) between Cr(VI) concentrations measured by the shin & Paik's Method and an impinger method (p>0.05). However, Cr(VI) concentrations determined by Shin & Paik's Method were Significantly different form those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(VI) concentrations of Shin & Paik's Method were Significantly higher than those of the NIOSH/EPA Method or the OSHA method. We concluded that the Shin & Paik's Method could prevent Cr(VI) losses caused by reduction and give more reliable results of airborne Cr(VI) concentrations in work environments.

  • PDF

Control and Investigation for Hazardous Characteristics of Metal Working Fluids Used in Korea - A Study on the Control and Sampling Method for Airborne MWF mist - (우리나라에서 사용하는 광물유의 유해특성과 관리대책에 관한 연구 - 공기중 MWF 미스트의 측정방법과 관리대책 -)

  • Paik, Nam-won;Park, Dong-wook;Yoon, Chung-sik;Cho, Sook-ja;Kim, Shin-bum;Lim, Ho-sub
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.171-180
    • /
    • 1997
  • The objectives of this study were both 10 discuss the sampling method for airborne metalworking fluids(MWF)' mist and 10 suggest measures to minimize worker's exposure to carcinogen contained in metalworking fluids. In order to measure airborne MWF mist, it seems to be appropriate to use NIOSH Method #0500(filler weight) rather than NIOSH Method # 5026(analysis by FTIR). Because MWF mist on PVC filter evaporated and migrated during sampling, worker's exposure to MWF could be underestimated. So, when evaluating worker's exposure to MWF mist, other environmental conditions also must be considered. Enclosure and local exhaust ventilation system seems to he the most effective measure and must be constructed with process facility. In order to control worker exposure to carcinogens contained in MWF, distillation type and condition for crude oil, PAH concentration in MWF, and viscosity index of MWF must legally be described.

  • PDF

Field Validation of alternative extraction method for the determination of airborne MWFs (대체용매를 이용한 금속가공유 측정방법 타당성에 대한 현장평가)

  • Jeong, Jee Yeon;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.2
    • /
    • pp.96-101
    • /
    • 2009
  • The purpose of this study was to conduct the field validation of alternative method(ETM method) by using non-carcinogenic, and less toxic solvents than NIOSH (National Institute for Occupational Safety and Health) analytical method 5524 for measuring the airborne metalworking fluids in workplaces. We carried out the field validation test by using the exposure chamber, guaranteeing the air sampling homogeneously in a machining environment. The ETM mixed solvent presented the complete solubility of MWFs used in test field. Based on the field test data, the bias of the ETM method from reference method, NIOSH analytical method 5524, was from -7.0% to 5.1%. The overall uncertainty of the ETM nethod was 21.6%, which satisfied the NIOSH criteria for the sampling and analytical criteria.

Validation of an Extraction Method for the Determination of Airborne MWFs using Alternative Solvents (대체용매를 이용한 금속가공유 측정방법 타당성 평가)

  • Jeong, Jee Yeon;Baek, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.91-100
    • /
    • 2006
  • The purpose of this study was to validate alternative method by using non-carcinogenic, and less toxic solvents than NIOSH analytical method 5524 for measuring the airborne MWFs in workplaces. In laboratory tests, the ETM solvents(mixture of same volume for ethyl ether, toluene, and ethanol) were selected. The alternative method of analyzing MWFs, referred to as the ETM solvent extraction method, showed 0.04 mg/sample as LOD, and 0.15 mg/sample as LOQ. The analytical precision (pooled CV, coefficient of variation) of the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was 1.5%, 2.0%, 2.6%, 1.6%, respectively, which was similar to the precision (2.6%) of NIOSH analytical method (NIOSH 0500) for total dust. The analytical accuracy by recovery test, spiked mass calculated as extractable mass, was almost 100%. As the result of storage stability test, metalworking fluid samples should be stored in refrigerated condition, and be analyzed in two weeks after sampling. The 95% confidence limit of the estimated total standard error for the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was ${\pm}12.6%$, ${\pm}12.5%$, ${\pm}14.0%$, and ${\pm}13.6%$, respectively, which satisfied the OSHA sampling and analytical criteria.

The Effect of Temperature on the Breakthrough of Charcoal Tube During Vinyl Chloride Monomer Sampling (공기중 염화비닐단량체 포집시 온도가 파과현상에 미치는 영향)

  • Park, Youn Jung;Lee, Sang Hoi;Kim, Chi Nyon;Won, Jong Uk;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.115-123
    • /
    • 1998
  • Vinyl chloride monomer exists as gas phase at normal temperature and reacts with oxygen and strong oxidant in the air to form oxidized materials. Because of being easily synthesized, it is used as a main source at the synthetic reaction process of PVC synthesis factories. Ministry of Labor regulates its usage as a carcinogen and its exposure level as 1 ppm. But the amount of VCM production in PVC and VCM production process hasn't been exactly estimated. In addition, facilities of this factory are located in outdoor. Therefore, this study was designed to investigate effects of temperature on breakthrough of charcoal tube at a fixed concentration and temperature during VCM sampling based on NIOSH and OSHA methods which were used as methods of occupational environment measuring and analysis. During the sampling of VCM, methods of OSHA and NIOSH require flow rate of 0.05 lpm and sampling volume of $3{\ell}$, $5{\ell}$ respectively, at this time carbon molecular sieve tube and coconut shell charcoal tube are used to observe the breakthrough along with concentration and temperature. As a result, significant difference between average adsorbed amounts of OSHA methods but that of NIOSH methods cannot be found. NIOSH method is likely to be effected by high temperature and normal temperature in high concentration. Breakthrough is not found in the method of OSHA at different conditions of temperature and concentration. As the result of this study we could verify that breakthrough occurred in the process of sampling VCM with NIOSH methods. Therefor in summer time, breakthrough should be considered and research on the breakthrough volume should be done. It is considered the research about the specificity of the coconut shell charcoal and carbon molecular sieve sorbent should be done when sampling VCM in comming days.

  • PDF

Job Stress Factor and Job Satisfaction in Clinical Nurse thorough of the NIOSH Job Stress Model (NOISH 직무스트레스 모형을 적용한 임상간호사의 직무스트레스 원인과 직무만족도 분석)

  • Lee, Jun Young;Jung, Hye Sun
    • Korean Journal of Occupational Health Nursing
    • /
    • v.13 no.1
    • /
    • pp.30-39
    • /
    • 2004
  • Purpose: This study was performed to identify the factors of the job stress and to analysis affecting job satisfaction in clinical nurses, using the Job Stress Model by the National Institute for Occupational Safety and Health (NIOSH). Method: Data collection was done from July 21 to July 30, 2003. The study was involved in 203 nurses who work at the hospital. It was examined the self-recording questionnaire about general characteristics, work-related factors, non-work factors, instrument revised by NIOSH Job Stress questionnaire translated by the Korea Occupational Safety & Health Research Institute(1999). Instrument about shift work was the tool developed by Kim and Gu(1984). Result: Job satisfaction of subjects at an average level with $1.96{\pm}0.37$ score on the basis of 3 points. According to general characteristics, job satisfaction was high in those with older age and married group. According to work related general factors, job satisfaction was high with working career, an officer to higher grade. According to work characteristics factors, job satisfaction was low with much role conflict at work and much workload and much interpersonal conflict. As for the relationship between job satisfaction and non-work factor, job satisfaction was did not show statistically significant differences. As a result of Stepwise multiple regression analysis, job satisfaction was influenced by shift work, conflicts of between group and grade of office. Conclusion: Therefore, it suggests that the nurses need stress management related shift work for improvement of job satisfaction.

  • PDF