• Title/Summary/Keyword: NFPA 13

Search Result 20, Processing Time 0.025 seconds

스프링클러 배관설계방식 고찰

  • Jeong, Gi-Sin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.50-51
    • /
    • 2013
  • 국내에서 스프링클러 설계 시 주로 적용하는 배관스케줄방식은 용도분류에 의해 결정되는 스케줄로, 배관의 구경이 선택되고 배관의 크기에 따라 설치될 수 있는 스프링클러헤드의 개수가 주어져 있는 스프링클러설비이다. 이는 NFPA13의 배관스케줄방식을 준용한 것이나 적용의 오류로 인하여 잘못된 설계를 수행하고 있다. 이를 시정하기 위하여 국내 기술기준과 NFPA13기준을 확인하고 문제점의 지적 및 바른 배관스케줄방식의 적용을 제시하고자 한다.

  • PDF

A Proposal on the Pipe Schedule Sprinkler System of NFSC 103 (NFSC 103 스프링클러설비의 배관스케줄방식에 대한 제안)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.40-47
    • /
    • 2014
  • Design by means of the pipe schedule sprinkler system of NFSC 103 results in insufficient pressure and flow rate about 50% sprinklers of operating area. In order to solve the lack of pressure and flow rate, This paper compare and analyzed NFSC 103, National Fire Safety Code of Sprinkler System, with NFPA 13, Standard for the Installation of Sprinkler Systems, and suggested an alternative proposal. Changing the flow rate of each sprinkler from existing 80 L/min to 120 L/min, All of the operating sprinklers are fulfilled the minimum demands on 80 L/min and 1 bar. It is easy for everyone to design of the pipe schedule sprinkler system and it is optimum method that all sprinklers in design area are satisfied with minimum criteria.

Seismic Analysis of Firefighting Pipe Networks (소방배관 형상에 따른 배관 내진해석)

  • Choi, Ho-Sung;Lee, Jae-Ou
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.149-154
    • /
    • 2019
  • The stability of firefighting pipes is crucial in the event of an earthquake. In Korea, specification-based designs are used in accordance with NFSC. However, engineering performance-based designs are used for buildings that have special requirements. For firefighting pipes, tree type pipe networks are usually utilized in buildings; however, they are characterized by several limitations. Hence, grid type and loop type networks are being utilized lately. Earthquake-resistant designs for firefighting pipes in Korea utilize NFPA 13 as the cookbook. Nevertheless, an engineering analysis is required to verify its reliability. The NFPA 13 standard used in Korea is a design method for engineers who lack earthquake engineering analysis knowledge of pipes and adapt ASCE and ASME guidelines. Earthquake resistant designs in Korea review braces only. Hence, various analyses under load conditions, such as the internal pressure of a pipe, force exerted by a continuous load, and an earthquake, are required to ensure reliability. An engineering earthquake-resistance analysis showed that tree type pipe networks are less stable than grid and loop type pipe networks. A comparison of earthquake-resistance analysis based on stress and strain revealed that strain analysis exhibited a conservative result value in the range of over-stress. Therefore, for the earthquake-resistance analysis of pipes, it is rational that engineers perform analysis to achieve the required standards through engineering analysis rather than uniform calculations, which should also be analyzed considering various analysis conditions.

A Study on Improvement of Discharge Obstruction Prevention Standard for Sprinkler Head on NFSC 103 (스프링클러설비 소화성능 향상을 위한 NFSC 103 살수장애 방지기준 개선 방안에 관한 연구)

  • Kim, Sunghyun;Lee, Sungsu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.237-247
    • /
    • 2020
  • Purpose: This study aims to draw the problems and improvements of NFSC 103 sprinkler head discharge obstruction prevention standard to increase the fire extinguishing performance of sprinkler system in order to contribute to the protection of people's lives and property in the event of a fire. Method: NFSC 103 was compared to NFPA 13 which is the latest 2019 version in U.S in terms of sprinkler head discharge obstruction prevention. Results: This study found that NFSC 103 doesn't define even the basic concept of sprinkler discharge obstruction. And NFSC 103 doesn't have detailed standard for side wall sprinkler head discharge obstruction prevention as well as the "height" criteria of the "three times" separation rule. Conclusion: NFSC 103 needs a lot of supplements and improvements such as the addition of definition for water discharge obstructions, the adoption of sidewall sprinkler heads standard for preventing water discharge obstructions and the additional establishment of the "three times rule" considering the "height" of obstacles to promote the advance of fire safety standard equal or above fire fighting advanced country and increase the reliability for the suppression performance of sprinkler system.

Research for the Configuration of the Outside Sprinkler System (외벽방호 스프링클러시스템 구성에 관한 연구)

  • Min, Se-Hong;Yun, Jung-Eun;Sun, Ju-Seok;Jeong, Sang-Ho;Chea, Chang-Hun;Kim, Suck-Jun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.102-112
    • /
    • 2012
  • In this research, configulation of outside sprinkler system the prevention and postponement of vertical diffusion of blaze was studied prior to this study, vertical diffusion protecting sprinkler head has been developed and the sprinkler system was applied with discharge pressure of 0.05 MPa and flow of 60 l/min witch is stated in NFPA13's Exposure Protection Sprinkler Systems. Through the system design, we applied the system to the sample building and we made pertinent system to work manually and automatically linked to a fire alarm system. Also, we conducted a real-size mock up test verify the cooling effect of the outer wall and the postponement effect of the flame.

A Study on the Revision of the National Fire Safety Codes of Sprinkler System (스프링클러설비 화재안전기준 개정에 대한 고찰)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.32-37
    • /
    • 2013
  • This paper suggested to revise unreasonable national fire safety codes of sprinkler system. Also proposed to modify the definition of "the gridded sprinkler system" and to add "the feed main" in terms of the definition of the pipes. In order to operate the regulations of discharge pressure of the sprinkler head efficiently, this paper checked the minimum criteria of pressure and flow for the pipe schedule sprinkler system of NFPA 13 and suggested to establish the similar minimum demand criteria. It proposed to be amended properly the pressure calculation formular in the pressure tank system and to use the correct K value due to change in pressure unit and to use the [bar] as a unit of pressure for the sake of using the existing K-factor etc.

A Study on the Seismic Protection Performance of Press Fittings for Light Gauge Stainless Steel Pipes (일반배관용 스테인리스강관에 대한 프레스식 관이음쇠의 내진성능에 관한 연구)

  • Baek, Yeal-Sun;Nam, Jun-Seok
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.65-70
    • /
    • 2017
  • The seismic performance of press fittings is studied, which is one of the weldless joints of stainless steel pipe used in the water piping of recent fire protection system. The piping of this study was constructed based on the piping connection reference of NFPA 13. The permissible displacement of the piping was set as the allowed amount which is given in the Building Structure Standard, and the measurements were repeated 10 times. The Von-mises stress of the piping was 2.48 and 1.25 times of the allowed amount of stress, which was less than the standard, noted three times on the NPPs Allowable Stress for Level D service loading. Therefore, the press fittings shows enough seismic performance.

Evaluation of Adequacy of Upper and Lower Tier Qualifying Quantities for the Substance Requiring Preparation for Accidents (사고대비물질 상위 및 하위규정수량의 적정성 평가)

  • Kim, Hyodong;Kim, Haelee;Seo, Cheongmin;Jun, Jinwoo;Park, Kyoshik
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.10-17
    • /
    • 2022
  • Currently, in Korea, lower and upper tier qualifying quantities of the 97 substances requiring preparation for accidents have been designated. The information on the submission of chemical accident prevention management plan varies depending on whether the handling volume is above or below the lower or upper qualifying quantity. Because the criteria of the lower and upper qualifying quantities of substance requiring preparation for accidents are not stipulated in the Chemical Substances Control Act, this study attempted to establish a criterion through significance verification. In addition, the study investigated whether these qualifying quantities are related to the Globally Harmonized System of Classification and Labelling of Chemicals (GHS), toxic concentration endpoint, and National Fire Protection Association (NFPA). Finally, by comparing the risk categorization of the GHS, endpoint, and NFPA, it was evaluated whether the circulation-volume-based risk categorization of the substance requiring preparation for accidents that are in the top 13 is appropriate. The qualifying quantities of benzene, toluene, and sulfuric acid needed to be adjusted upward, while those of methyl alcohol and ammonia were adjusted downward from the current qualifying quantities. It is required to establish a quantified criterion that fully reflects the domestic situations in Korea and various indicators such as toxicity, physicochemical properties, and circulation volume for the qualified criterion of hazardous chemical substances. The study is expected to be helpful in establishing an efficient system by systematizing the criterion for qualifying quantity.

A Study on the Increase Installation of Sprinkler System in Residential Occupancies (주거용 스프링클러설비 설치의 확대에 관한 연구)

  • Jeong, Hyun-Gyu;Song, Yong-Sig;Lee, Jun-Suk;Cho, Won-Chol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.522-525
    • /
    • 2007
  • This study is for reduce the damage of human life and property occurred by a fire in the normal house and market according to increase rate of a fire. this is focused on the present domestic code about prevent a fire and sprinkler system in residential occupancies.

  • PDF