• 제목/요약/키워드: NEDT

검색결과 3건 처리시간 0.022초

Negative Exponential Disparity Based Deviance and Goodness-of-fit Tests for Continuous Models: Distributions, Efficiency and Robustness

  • Jeong, Dong-Bin;Sahadeb Sarkar
    • Journal of the Korean Statistical Society
    • /
    • 제30권1호
    • /
    • pp.41-61
    • /
    • 2001
  • The minimum negative exponential disparity estimator(MNEDE), introduced by Lindsay(1994), is an excellenet competitor to the minimum Hellinger distance estimator(Beran 1977) as a robust and yet efficient alternative to the maximum likelihood estimator in parametric models. In this paper we define the negative exponential deviance test(NEDT) as an analog of the likelihood ratio test(LRT), and show that the NEDT is asymptotically equivalent to he LRT at the model and under a sequence of contiguous alternatives. We establish that the asymptotic strong breakdown point for a class of minimum disparity estimators, containing the MNEDE, is at least 1/2 in continuous models. This result leads us to anticipate robustness of the NEDT under data contamination, and we demonstrate it empirically. In fact, in the simulation settings considered here the empirical level of the NEDT show more stability than the Hellinger deviance test(Simpson 1989). The NEDT is illustrated through an example data set. We also define a goodness-of-fit statistic to assess adequacy of a specified parametric model, and establish its asymptotic normality under the null hypothesis.

  • PDF

수동형 퓨리에변환 적외선 분광기의 잡음등가온도지수 (Noise Equivalent Differential Temperature of Passive FTIR Sensor System)

  • 강영일;박병황;최명진;홍대식;최수;김동환;박도현
    • 한국군사과학기술학회지
    • /
    • 제14권2호
    • /
    • pp.161-166
    • /
    • 2011
  • The passive open-path Fourier-Transform-Infrared system was implemented for the toxic gas monitoring. Noise Equivalent Differential Temperature(NEDT) was investigated as a system performance evaluation figure and analyzed numerically with the designed parameters. Calculated NEDT was compared with the experimental value in the wavelength region of $700{\sim}1400cm^{-1}^$. The minimum detectable gas concentration was estimated from the obtained NEDT at the absorption wavelength of $SF_6$.

열화상카메라 개발을 통한 의료용 체열진단 가능성 평가 (Development and Possibility Evaluation of Thermal Imaging Camera for Medical Monitoring of Body Temperature)

  • 유성미;김혜정
    • 한국산업정보학회논문지
    • /
    • 제20권1호
    • /
    • pp.57-62
    • /
    • 2015
  • 최근 인체에서 방출되는 적외선을 감지하여 질병부위를 진단하는 의료기기로써 체열촬영이 가능한 열화상카메라가 활용되고 있다. 본 연구에서는 칼코지나이드 소재 적외선 성형렌즈를 채용한 열화상카메라 시제품을 제작하고, 열영상 분석을 통해 체열진단 장비로써의 시제품 성능을 검증하였다. 열화상카메라 시제품은 $20{\sim}50^{\circ}C$에서 체열이 촬영됨을 확인 하였고, 온도분해능(NEDT) 측정결과 87.7mK의 우수한 결과를 나타냈다. 이를 통해 칼코지나이드 성형렌즈를 채용한 열화상카메라 시스템이 체열진단을 위한 의료기로 사용가능함을 확인 하였다.