• Title/Summary/Keyword: NDT

Search Result 442, Processing Time 0.029 seconds

Development of Differential Type Eddy Current Probe for NDT Evaluation of the Steam Generator Tube (증기발생기 전열관의 비파괴 탐상용 차등형 와전류 탐촉자 개발)

  • Jung, S.Y.;Son, D.;Ryu, K.S.;Park, D.K.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.5
    • /
    • pp.292-297
    • /
    • 2005
  • Steam generator of a nuclear power plant has important rolls for the heat transfer and the isolation of radioactive materials. So bursting of the steam generator tube is directly related to the accident of nuclear power plants. Incone1600 has been used for the steam generator tube material. The material shows non-magnetic and metallic properties, eddy current NDT method has been employed for defects detection. In this work, a differential type of eddy current probe was developed to improve resolution of defect detection. To verify properties of the developed differential type eddy current probe, we have made reference material with SUS304 which has similar magnetic and electrical properties of Inconel600. Using the developed differential type eddy current probe, we can detect defect size of 0.25 mm in diameter and 0.2 mm in depth (volume of $1{\times}10^{-3}\;mm^3$) with the reference material.

The effect of intrinsic foot muscle training on medial longitudinal arch and ankle stability in patients with chronic ankle sprain accompanied by foot pronation

  • Chung, Kyoung A;Lee, Eunsang;Lee, Seungwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.78-83
    • /
    • 2016
  • Objective: The purpose of this study was to investigate whether the intrinsic foot muscle training method can improve the medial longitudinal arch in patients with chronic ankle injury and with pronated feet, as well as to investigate for the most effective exercise method for these patients. Design: Randomized controlled trial. Methods: Thirty men and women with pronated feet had participated in this study and were allocated to either the short foot exercise group (SFEG) or the towel curl exercise group (TCEG) randomly. SFEG and TCEG underwent exercises three times a week for 8 weeks, with three sets per day, totalling up to 5 minutes per day. The navicular drop test (NDT) was used in order to assess for changes in the medial longitudinal arch and the Cumberland ankle instability tool (CAIT) was used to assess for ankle instability of the chronic ankle sprain patients. Results: There was a significant increase in CAIT scores in the SFEG (p<0.05) and a significant difference between groups was presented (p<0.05). The NDT scores were significantly decreased in both groups (p<0.05). In the SFEG, the NDT scores were more decreased than in the TCEG (p<0.05). Conclusions: These results suggest that short foot exercises are more effective in providing intrinsic foot muscle training for patients with pronated feet among chronic ankle sprain patients. Furthermore, short foot exercises may be used to provide ankle stability.

Development of A Torrefaction Unit of High Moisture Food & Agricultural Wastes (음식물 및 농업폐기물 열분해장치 개발)

  • Song, Dae Bin;Lim, Ki Hyeon;Jung, Dae Hong;Yoon, Jong Hyeon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.116-116
    • /
    • 2017
  • 2012년 국내 총 폐기물(지정폐기물 제외) 발생량은 382,009 톤/일 으로 이 중 12.8%를 차지하는 생활폐기물 중 음식물 채소류폐기물 발생량은 13,209 톤/일 으로 대부분 소각 후 매립 처리되고 있다. 본 연구에서는 고수분 음식물 및 농업 폐기물을 재활용한 고형연료 제조에 필요한 열분해장치를 개발하고 실험을 통해 그 성능을 확인하고자 하였다. 본 연구를 위해 건조용량 50 kg/hr인 실험실용 열분해장치를 제작하였다. 건조 처리된 농업폐기물과 음식물 쓰레기를 열분해용 실험 원료로 사용하였다. 원료종류, 열분해 온도, 열분해 시간에 따른 농업폐기물과 음식물 쓰레기의 열분해 특성을 파악하였다. 농업부산물 건조물의 열분해 처리 결과, 열분해 처리능력은 평균 55.35 kg/hr, 저위발열량은 평균 3,333 kcal/kg으로 측정되었다. 농업부산물을 단순 건조 처리한 경우 고위발열량은 3,400 kcal/kg, 저위발열량은 3,090 kcal/kg으로 측정되어 열분해처리로 발열량이 향상됨을 알 수 있다. 음식물 쓰레기 건조물의 열분해 처리조건 및 결과, 열분해 처리능력은 평균 88.27 kg/hr, 저위발열량은 평균 4,016 kcal/kg으로 측정되었다. 음식물 쓰레기를 단순 건조 처리한 경우 고위발열량은 4,040 kcal/kg, 저위발열량은 3,686 kcal/kg으로 측정되어 열분해처리로 발열량이 향상됨을 알 수 있다. 열분해 처리능력은 연구목표치인 50 kg/hr보다 높게 나타났으며, 저위발열량은 연구목표치인 4,000 kcal/kg 보다 다소 높게 나타났다. 다만 저위발열량 측정 기준 함수율이 습량기준으로 약 10%로 추정되는 바 5%로 조절하고, 열분해 열풍온도를 $200^{\circ}C$ 까지 상승시키면 발열량이 훨씬 향상될 것으로 판단된다.

  • PDF

Study on the Feasibility of High-Temperature Immersion Ultrasonic Sensor with a Strip Waveguide (도파띠를 이용한 고온 액침 초음파센서의 가능성 연구)

  • Choi, M.S.;Lee, J.P.;Jung, T.E.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.151-156
    • /
    • 1994
  • Exertion has been made to develop high-temperature (about $250{\sim}650^{\circ}C$) immersion ultrasonic sensor for the visualization of objects, temperature measurement, dimensional check, or nondestructive testing of welds under liquid sodium. In this study, the feasibility of the ultrasonic sensor taking advantage of a strip waveguide was confirmed by water-experiment. The lowest order of antisymmetric Lamb wave was used in the frequency range with negligible dispersion. This plate wave was excited in the stainless steel strip waveguide of 1.0mm thickness and 13mm width by the comb-structure transducer of 2.3MHz frequency. Its attenuation coefficient was 1.2dB/m in air and 380dB/m in water. The signal to noise ratio of 25dB was obtained from a planar reflector 270mm away from the beam aperture of $13mm{\times}39mm$ size.

  • PDF

Application of Non-Destructive Testing Techniques to the Evaluation of Integrity of Drilled Shaft (비파괴시험을 이용한 현장타설말뚝의 건전도 평가에 관한 연구)

  • Chae, Jong-Hoon;Yu, Jae-Myung;Kim, Dae-Kyu;Lee, Woo-Jin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.4
    • /
    • pp.5-14
    • /
    • 2001
  • The NDT(Non-Destructive Testing) technique, detecting defects without damaging foundations, has, lately, been a matter of concern. In this study, the applicability of the borehole methods(CSL, CT, PS) and the surface reflection methods(SE, IR) to the evaluation of integrity of drilled shaft was investigated through field test. Ten drilled shafts, 0.4 m in diameter and 7.0 m long each, were constructed, one shaft with no defect and nine shafts intentionally with the combination of the common defects such as soft bottom, necking, bulging, cave-in, and/or weak concrete. Analysing each NDP test result on the constructed drilled shafts, an optimum combination of the NDP methods as well as the applicability of each NDP method to detecting defects of drilled shaft have been investigated.

  • PDF

Structural Integrity Evaluation of Nozzle Assembly using Acoustic Emission Technique (음향방출법을 응용한 노즐 조립체의 구조건전성 평가)

  • 설창원;이기범
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.10
    • /
    • pp.32-39
    • /
    • 2006
  • An acoustic emission technique was applied to the structural strength test for the structural integrity evaluation of the nozzle assembly. These AE results were compared with data from the strain gages and displacement transducer. NDT using X-ray technique was performed to improve the test reliability before and after each test. In this structural integrity evaluation of the nozzle assembly, the internal crack initiation in the structure could not be precisely revealed by the strain and displacement results but the location and load level of the initiated crack could be precisely evaluated by using AE technique. From this test, it was proven that some new cracks can be generated in composite liner of nozzle assembly under the unexpected load due to interference between obturator and nozzle and these can be a cause of the unexpected abnormal failure.

A Study on the Nondestructive Test Optimum Design for a Ground Tracked Combat Vehicle (지상궤도전투장비의 비파괴검사 최적설계방안에 대한 연구)

  • Kim, Byeong Ho;Seo, Jae Hyun;Gil, Hyeon Jun;Kim, Seon Hyeong;Seo, Sang Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.358-366
    • /
    • 2015
  • In this study, a nondestructive test (NDT) is performed to inspect the optimal design of a ground tracked combat vehicle for self-propelled artillery, tank, and armored vehicles. The minimum qualification required for personnel performing the NDT of a ground tracked combat vehicle was initially established in US military standards, and then applied to the Korean defense specifications to develop a ground tracked combat vehicle. However, the qualification standards of an NDT inspector have been integrated into NAS410 through the military and commercial specifications unification project that were applied in the existing aerospace/defense industry public standard. The design method for this study was verified by applying the optimal design to the liquid penetrant testing Al forging used in self-propelled artillery. This confirmed the reliability and soundness of the product.

Piezoelectric Transducer for Ultrasonic Flaw Detector with High Performance (고성능 초음파 결함탐상기를 위한 압전변환기)

  • Jung, Jun Hwan;Jun, Ho Ik;Kim, Hyun-Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1645-1652
    • /
    • 2013
  • In this paper, a new piezoelectric transducer for high performance ultrasonic flaw detector used in non-destructive test (NDT) is implemented. Here, the goals for some major characteristics such as piezoelectric strain constant and electro-mechanical coupling factor are fixed in advanced. Then, the parameters obtained by finite element analysis (FEA) are exploited to design and implement the piezoelectric transducer. As a result of experiments using manufactured samples, it is proved that the new PZT ceramics satisfy the goals very well. It has much improved impedance characteristic at the resonant frequency and generation of ultrasonic signals. In addition, ultrasonic flaw detector with the new transducer provides increased flaw detecting gain than the conventional one. Thus, it is considered that the new flaw detector contributes significantly to improve reliability of the NDT.

The Development of an Algorithm for Internal Defect Inspection of Concrete using Ultrasonic Detective Device and Radar Equipment (초음파 및 레이더를 활용한 콘크리트 내부결함탐상 알고리즘 개발)

  • Oh, Hong-Seob;Ju, Min-Kwan;Lee, Ju-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1029-1032
    • /
    • 2008
  • Nowadays, the necessity of the NDT technique for concrete structure has been increased due to maintenance of infra-structure. With this reason, NDT detecting technique has been considered as a effective maintenance method to prevent the rapid degradation of the infra-structure. In this study, to investigate the internal defect of concrete structure, ultrasonic detection device and radar equipment was applied then tested in laboratory and field. In the result of the experimental test, the internal cavity and steel arrangement can be detected and it was possible to adopt the ultrasonic detection method to the maintenance of concrete structure. And an algorithm for performing the maintenance procedure of concrete structure applying ultrasonic detection device and radar equipment was developed and suggested in this study.

  • PDF