• Title/Summary/Keyword: NDD-M

Search Result 12, Processing Time 0.024 seconds

Non Dosimetry Measurements Use for Patients Safety : NDD-M (환자 안전을 위한 비 계측 선량측정의 활용 : NDD-M)

  • Gil, Jong-Won;Seon, Jong-Ryoul;Song, Wol-Su
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.141-145
    • /
    • 2016
  • This study was to improve to utilization of non dosimetry measurements for X-ray radiography. Experiments was passed off varying the X-ray tube voltage and the thickness of the aluminum filter by actual dose. Calculated results was set to the first beam quality factors, calculated first correction coefficient by the Microsoft Excel program was set as the second beam quality factors. To make the non dosimetry measurements simply, the Excel program apply to the new beam quality factors, the error was compared to the previous studies, and the results verify the calculated value of smaller errors.

Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor (선질계수에 의한 피부입사선량 계산법)

  • Kim, Sung-Chul;Kim, Chong-Yeal;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.258-267
    • /
    • 2010
  • This interest in radiation exposure makes increasing doctor's awareness and knowledge of radiation dose in patients during X-ray test important in reducing patient's uneasiness. However, very few facilities are equipped with measurement instruments. Therefore, an intensive study to find out patient dose using computational method has been initiated. This study used special features of the bit system and NDD-M and directly measured the output dose of diagnostic X-ray instruments used in Korea to create tables. Two different methods were found to be adequate when applied to cases when X-ray outputs were both known and unknown, and comparative experiments with real measurement doses were carried out. Presented methods were found to provide more accurate results compared to the bit system and NDD-M. Therefore, patient dose during clinical trials were found to be more easily acceptable to medical personnel in the radiation field in terms of radiation exposure and reduction of medical X ray dose.

Evaluation of co- and Mutual Weparation for Actinide(III) and RE by a $(Zr-DEHPA)/n-dodecane-HNO_3$ Extraction System ($(Zr-DEHPA)/n-dodecane-HNO_3$ 금속함유 추출 계에 의한 악티나이드(III)및 RE의 공추출 및 상호 분리)

  • Lee, Eil-Hee;Lim, Jae-Kwan;Chung, Dong-Yong;Yang, Han-Beom;Kim, Kwang-Wook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.2
    • /
    • pp.123-132
    • /
    • 2007
  • This study was performed to evaluate the co- and mutual separation for Am, Cm and RE elements from the simulated multi-component solution equivalent to real HLW level by a Zr-DEHPA(di-(2-ethylhexyl) phosphoric acid containing Zirconium)/$NDD(n-dodecane)-HNO_3$ extraction system. Zr-DEHPA was self-synthesized and the optimal condition of (15g/L Zr-1M DEHPA)/NDD-1M $HNO_3$ was selected taking into consideration of prevention of the third phase, and effects of concentration of DEHPA, nitric acid and impregnant amount of Zr on the co-extraction of Am, Cm and RE. In that condition, the extraction yields were 81% (Am), 85% (Cm), more than 80% (RE elements), 98% (Mo), 85% (Fe), 98% (U), 73% (Np), and less than 5% (other elements) so that the system developed for the co-extraction of Am-Cm/RE was proved to be available. For that, however, U, Np, Mo and Fe was elucidated to have to be removed in advance, and Zr inducing the third phase formation was found to be practically excluded. The co-extracted Am-Cm/RE were sequentially separated in an order of Am-Cm (stripping agent : 0.05 M DTPA-1M Lactic acid of pH 3.6)${\rightarrow}RE$ (stripping agent : 5M $HNO_3$), and then their separation factors were evaluated. At above conditions, Am of 65.4%, Cm of 63.9%, RE (except for Y) of more than 85% were stripped.

  • PDF

Evaluation of co- and Sequential Separation for Tc, Np and U by a $(TBP-TOA)/n-dodecane-HNO_3$ Extraction System ($(TBP-TOA)/n-dodecane-HNO_3$ 추출 계에 의한 Tc, Np, U의 공추출 및 순차분리 평가)

  • Lee, Eil-Hee;Lim, Jae-Kwan;Chung, Dong-Yong;Yang, Han-Beom;Kim, Kwang-Wook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.2
    • /
    • pp.133-143
    • /
    • 2007
  • This study was performed to evaluate the co- and sequential separation of Tc, Np and U from the simulated multi-component HLW solution by a TBP (tributyl phosphate)-TOA (tri- octyl amine)/NDD $(n-dodecane)-HNO_3$ extraction system. An optimal condition of (30% TBP-0.5% TOA)/NDD-1 M $HNO_3$ was selected by taking account of a prevention of the 3rd phase and effects of concentration of TBP, TOA and nitric acid on the co-extraction of Tc, Np and U. In that condition, the extraction yields were 81% (Tc), 85% (Np), less than 9% (Am and RE elements), about 8% (Pd), and less than 5% (other elements) so that the system developed for the co-extraction of Tc, Np and U was proved to be available. For that, however, more than 99% of Zr was found to be pre-removed. The co-extracted Tc, Np and U were sequentially separated in order of Tc(stripping agent : 5 M $HNO_3$)${\rightarrow}Np$ by reductive stripping (reductive-stripping agent : 0.1 M AHA)${\rightarrow}U$ (stripping agent : 0.01 M $HNO_3$), and then their separation factors were evaluated. At these conditions, 95% of Tc, 98% of Np and 99% of U could be recovered in each step.

  • PDF

High tendency to the substantial concern on body shape and eating disorders risk of the students majoring Nutrition or Sport Sciences

  • Nergiz-Unal, Reyhan;Bilgic, Pelin;Yabanci, Nurcan
    • Nutrition Research and Practice
    • /
    • v.8 no.6
    • /
    • pp.713-718
    • /
    • 2014
  • BACKGROUND/OBJECTIVES: Studies have indicated that university students majoring in nutrition and dietetics or sport sciences may have more obsessions associated with eating attitudes and body shape perception compared to other disciplines i.e. social sciences. Therefore, this study aimed to assess and compare the risk of eating disorders and body shape perception. MATERIALS/METHODS: Data was collected from 773 undergraduate students at the Departments of Nutrition and Dietetics (NDD) (n = 254), Physical Education and Sports (PESD) (n = 263), and Social Sciences (SOC) (n = 256).A socio-demographic and personal information questionnaire, Eating Attitudes Test (EAT-40), Body Shape Questionnaire (BSQ-34), Perceived Figure Rating Scale (FRS) were applied; and body weights and heights were measured. RESULTS: Mean EAT-40 scores showed that, both male and female students of PESD had the highest scores ($7.4{\pm}11.6$) compared with NDD ($14.3{\pm}8.3$) and SOC ($13.0{\pm}6.2$) (P < 0.05). According to EAT-40 classification, high risk in abnormal eating behavior was more in PESD (10.7%) compared to NDD (2.9%) and SOC (0.4%) students (P < 0.05). Students of PESD, who skipped meal, had higher tendency to the risk of eating disorders (P < 0.05). In parallel, body shape perception was found to be marked with higher scores in NDD ($72.0{\pm}28.7$) and PESD ($71.5{\pm}32.8$) compared with SOC ($64.2{\pm}27.5$) students (P < 0.05). Considering BSQ-34 classification, high concern (moderate and marked) for body shape were more in PESD (7.4 %) compared to NDD (5.2%) and SOC (1.9%) students (P < 0.05). The body size judgement via obtained by the FRS scale were generally correlated with BMI. The Body Mass Index levels were in normal range (Mean BMI: $21.9{\pm}2.8kg/m^2$) and generally consistent with FRS data. CONCLUSIONS: Tendency to the abnormal eating behavior and substantial body shape perception were higher in PESD students who have more concern on body shape and were not well-educated about nutrition. In conclusion, substantial concern on physical appearance might affect eating behavior disorders in PESD students.

Comparative Study of Radiation Exposure using Entrance Skin Dose Calculation Technique in Diagnostic X-Ray Radiography (입사 표면 선량 계산에 따른 진단용 X-선 촬영시 피폭선량 비교 연구)

  • Han, Jae-Bok;Choi, Nam-Gil;Sung, Ho-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.357-363
    • /
    • 2011
  • The aim of this study is to compare radiation dose in diagnostic X-ray radiography and calculated by different mathematical equation. The result of ESDs direct measurement and that calculated by Mori NDD-M shows the biggest difference. On the other hand, equation by Edmonds shows the lowest difference of ESDs. Also, Rectification due to the difference between direct dose measurement and calculation method commutated three-phase, single phase and inverter type, show less difference in the drive way. In conclusion, this study can be helpful for expecting radiation dose-exposure and control exposure parameters for the diagnostic x-ray radiography.

An Assessment of Entrance Surface Dose Using the nanoDot Dosimeter (나노도트선량계를 이용한 입사표면선량의 평가)

  • Kim, Jong-Eon;Im, In-Chul;Park, Cheol-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.377-381
    • /
    • 2011
  • The purpose of this study is an assessment between the measured value of the nanoDot dosimeter and the calculated value of Non Dosimeter Dosimetry-Method(NDD-M) for entrance surface dose in general radiography. Measurement and calculation of the entrance surface doses were performed for head(AP), abdomen(AP), pelvis(AP), thoracic spine(AP) and lumbar spine(AP). As a result, the relative ratios of the measured value to the calculated value were acquired 1.5-2.1 for each region. Reproducibility acquired 0.035 as a coefficient of variation.

A Comparison of Dose in Changed Technique Factor Using X-ray Imaging System (X-선 장치의 기술적 인자의 변화에 따른 선량 비교 평가)

  • Han, Dong-Kyoon;Ko, Shin-Gwan;Seon, Jong-Ryul;Yoon, Seok-Hwan;Jung, Jae-Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.101-107
    • /
    • 2009
  • With the recent development of diagnosis using radiation and increasing demand of the medical treatment, we need to minimize radiation exposure dose. So, This is the method which reduce patient dose by measuring surface dose of radiographic change factor and by comparing theoretical and actual dose, when we take an X-ray which is generally used. By changing the factor of kV, mAs, FSD, whose range is 60 to 120 kV, 20 to 100 mAs, 80 to 180 cm, we compared theoretical surface dose with actual surface dose calculated by the simple calculation program, Bit system, and NDD-M method As a result, when kV and mAs were higher, theoretical surface dose and actual surface dose were more increased. but the higher FSD was, the more decreased surface dose was. According to this, the error were measured about 0.1 to 0.2 mGy in low dose part and about 0.7 to 1.5 mGy in high dose part. Therefore, this shows that theoretical surface dose calculation method is more correct in low dose part than in high dose part. In conclusion, we will have to make constant efforts which can reduce patient and radiographer's exposure dose, studying methods which can predict patient's radiation exposure dose more exactly.

  • PDF

CO-SEPARATION OF Am AND RARE EARTH ELEMENTS FROM A HIGHLY ACIDIC RADWASTE SOLUTION BY A SOLVENT EXTRACTION WITH (DIMETHYLDIBUTYL TETRADECYLMALONAMIDE-DIHEXYLOCTANAMIDE)/N-DODECANE

  • Lee, Eil-Hee;Lim, Jae-Gwan;Chung, Dong-Yong;Yoo, Jae-Hyung;Kim, kwang-Wook
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.319-326
    • /
    • 2009
  • This study was carried out to investigate the high-acidity co-separation of Am and RE from a simulated radwaste solution by a solvent extraction using a mixture of Dimethyldibutyltetradecylmalonamide (DMDBTDMA, as an extractant) and dihexyl octanamide (DHOA, as a phase modifier) diluted with n-dodecane (NDD). All the experiments were conducted as a batch type. First, the environmentally friendly DMDBTDMA and DHOA composed of only CHON atoms were self-synthesized. Then, the conditions for the prevention of a third phase, generated in the organic phase were examined. In addition, the effects of the concentration of nitric acid, DHOA, oxalic acid and $H_2O_2$ on the co-extraction of Am and RE were elucidated. Consequently, the optimum condition of (0.5M DMDBTDMA+0.5M DHOA)/NDD-0.3M $C_2H_2O_4-4.5M$ $HNO_3$ and O/A=2 was obtained through experimental work. Under this condition, the extraction yields were found to be about 80% for Am, more than 70% for RE such as La, Eu, Nd, Ce, etc., 3% for Cs and Sr, 69% for Fe and less than 11% for Mo and Ru. For the co-extraction of Am and RE, Fe should be removed in advance or prevented from a co-extraction with Am by controlling the different extraction rates of Am and Fe. About 95% of the Am and RE in the organic phase were stripped using a 0.5M $HNO_3$.

Patient Dose for Diagnostic Radiological Procedures in Korea (일반 X-선 촬영에서의 환자피폭선량에 관한 조사연구)

  • Kim, You-Hyun;Choi, Jong-Hak;Kim, Sung-Soo;Lee, Chanh-Yeup;Lee, Young-Bae;Kim, Chel-Min
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.59-63
    • /
    • 2004
  • IAEA's Guidance Levels have been provided for Western people to the end. Guidance levels lower than the IAEA'S will be necessary in view of korean people's proportions. Therefore, We need to develope the standard doses for korean people. And we conducted a nationwide survey of patient dose from x-ray examinations in korea. 278 institutions were selected from Members Book of Korean Hospital Association. The valid response rate was approximately 57.9%. Doses were calculated from the questionnaires by NDD method. The results were as follows; 1) General radiographic equipments were 43%, fluoroscopic equipments 29%, dental equipments 13%, CT units 8% and mamographic units 7%. 2) According to classification by rectification way, three-phase equipments were 30%, inverter-type generators 29%, single- phase equipments 26%, unknown units 6%. 3) According to classification by receptor system, film-screen types were 46%, CR types 27%, OR types18% and unknown types 9%. 4) The number of examinations were chest 48%, spine 17% and abdomen 13%. 5) Patient doses were head AP 3.1 mGy, abdomen AP 3.5 mGy and chest PA 0.4 mGy.

  • PDF