• Title/Summary/Keyword: N95

Search Result 3,317, Processing Time 0.038 seconds

Water-blocking Asphyxia of N95 Medical Respirator During Hot Environment Work Tasks With Whole-body Enclosed Anti-bioaerosol Suit

  • Jintuo Zhu;Qijun Jiang;Yuxuan Ye;Xinjian He;Jiang Shao;Xinyu Li;Xijie Zhao; Huan Xu;Qi Hu
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.457-466
    • /
    • 2023
  • Background: During hot environment work tasks with whole-body enclosed anti-bioaerosol suit, the combined effect of heavy sweating and exhaled hot humid air may cause the N95 medical respirator to saturate with water/sweat (i.e., water-blocking). Methods: 32 young male subjects with different body mass indexes (BMI) in whole-body protection (N95 medical respirator + one-piece protective suit + head covering + protective face screen + gloves + shoe covers) were asked to simulate waste collecting from each isolated room in a seven-story building at 27-28℃, and the weight, inhalation resistance (Rf), and aerosol penetration of the respirator before worn and after water-blocking were analyzed. Results: All subjects reported water-blocking asphyxia of the N95 respirators within 36-67 min of the task. When water-blocking occurred, the Rf and 10-200 nm total aerosol penetration (Pt) of the respirators reached up to 1270-1810 Pa and 17.3-23.3%, respectively, which were 10 and 8 times of that before wearing. The most penetration particle size of the respirators increased from 49-65 nm before worn to 115-154 nm under water-blocking condition, and the corresponding maximum size-dependent aerosol penetration increased from 2.5-3.5% to 20-27%. With the increase of BMI, the water-blocking occurrence time firstly increased then reduced, while the Rf, Pt, and absorbed water all increased significantly. Conclusions: This study reveals respirator water-blocking and its serious negative impacts on respiratory protection. When performing moderate-to-high-load tasks with whole-body protection in a hot environment, it is recommended that respirator be replaced with a new one at least every hour to avoid water-blocking asphyxia.

The Development of Fixing Equipment of the Unit Module Using the Probability Distribution of Transporting Load (운반하중의 확률분포를 활용한 유닛모듈 운반용 고정장치 개발)

  • Park, Nam-Cheon;Kim, Seok;Kim, Kyoon-Tai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4267-4275
    • /
    • 2015
  • Prefabricated houses are fabricated at the factory for approximately 60 to 80% of the entire construction process, and assembled in the field. In the process of transporting and lifting, internal and external finishes of the unit module are concerned about damages. The purpose of this study is to improve the fixing equipment by analyzing load behavior. The improved fixing equipment would minimize the deformation of internal and external finishes. In order to develop the improved fixing equipment, transporting load on the fixing equipment is analyzed using Monte Carlo simulations, and structural performance is verified by the non-linear finite element analysis. Statistical analysis shows load distribution of unit module is similar with extreme value distribution. Based on the statistical analysis and Monte Carlo simulation, the maximum transporting load is 28.9kN and 95% confidence interval of transporting load is -1.22kN to 9.5kN. The nonlinear structural analysis shows improved fixing equipment is not destructed to the limit load of 35.3kN and withstands the load-bearing in the 95% confidence interval of transporting load.

A Study on Complexation of Cu(Ⅱ) Ion with Hydrazide Schiff Base Lignads (Cu(Ⅱ) 이온과 Hydrazide Schiff Base 리간드와의 착물형성에 관한 연구)

  • Cho, Hwee Kyung;Cha, Bun Hee;Hur, Young Ae;Choi, Kyu Seong
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.4
    • /
    • pp.281-287
    • /
    • 1995
  • Copper(Ⅱ) complexes with N,N'-oxalylbis(salicylaldehydehydrazone), N,N'-malonylbis(salicylaldehydehydrazone) and N,N'-succinylbis(salicylaldehydehydrazone) have been prepared in 95% DMF. Their protonation and stability constants were investigated by potentiometric titration. We observed that MBSH ligand showed the largest protonation constant. The values of the protonation constants among three different ligands were increased as following order SBSH < OBSH < MBSH. However, the increasing order of stability constants was somewhat different such as Cu(Ⅱ)-SBSH < Cu(Ⅱ)-MBSH < Cu(Ⅱ)-OBSH. In addition, thermodynamic parameters, ΔH and ΔS of Cu(Ⅱ) complexes have been studied. As a result, we found the SBSH ligand produced the best stable copper (Ⅱ) complex.

  • PDF

Sintering of Aluminum Nitride (I) : Pressureless Sintering (질화알루미늄의 소결(I) : 상압소결)

  • Choi, Sang-Wook;Lee, Hee-Chul;Rhee, Jhun;Lee, Im-Chang
    • Journal of the Korean Ceramic Society
    • /
    • v.28 no.6
    • /
    • pp.457-464
    • /
    • 1991
  • Aluminum nitride (AlN) has excellent properties such as high thermal conductivity and electrical resistivity, whereas it has some disadvantages such as low sinterability and tendency to be hydrolyzed by moisture at room temperature. In the present work, the relative density, modulus of rupture and microhardness were examined for pressure-less-sintered AlN (synthetic and commercial) bodies which were prepared under the conditions of various sintering temperatures, holding times and additions of CaCO3 which showed the best effect on sinterability among the various sintering aids. As a result, the AlN bodies with 1.0 wt% CaCO3 (0.56wt% CaO) which were sintered at 1800$^{\circ}C$ for 20 min showed good densification. In this case, the relative densities were 95.9% and 95.2%, and microhardnesses were 10.3 GPa and 9.8 GPa for synthetic and commercial AlN respectively. And as the holding time at 1800$^{\circ}C$ was increased from 10 min to 60 min, the relative density was increased from 91.9% to 96.5%. It was considered that impurities of metals and oxygen promoted the densification of AlN at low temperature (1600$^{\circ}C$).

  • PDF

Virtual Radix Counting Bucket sort (가상의 기수계수버킷 정렬)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.95-102
    • /
    • 2015
  • Generally, there is no sorting algorithm much faster than O(nlogn). The quicksort has a best performance O(nlogn) in best and average-case, and $O(n^2)$ in worst-case. This paper suggests virtual radix counting bucket sort such that counting the frequency of numbers in each radix digit, and moves the arbitrary number to proper virtual bucket in the array, and divides the array into radix digit numbers virtually. Also, this algorithm moves the data to proper location within an array for using the minimum auxiliary memory. This algorithm performs k-times such that the number of k digits in given data and the time complexity is O(n). Therefore, this algorithm has a O(kn) time complexity.

X-Ray Crystal Structure Determination of Diazatricyclodione (디아자트리사이클로디온의 X선 결정구조 결정)

  • Kim, Sang-Su;An, Jong-Il;Han, Bo-Seop
    • Korean Journal of Crystallography
    • /
    • v.1 no.2
    • /
    • pp.84-90
    • /
    • 1990
  • 1,3-Diazatricyclo (5.2.1.Os .to) decane-2,11-dione , C8H10N2O2. MW=166.15, Monoclinic, P2/n a= 6.585(7) , b=9.089(4), c=12.937(10)A, β=95.72(5)˚, V=770.4A3, Z=4, Dc=1.43(4) g/cm3, λ (Mo Ka)=0.7093A, r=1.Ocm-1, T=295˚K, final R=0.037 for 698 unique observed reflections. The compound is the product of the intramolecular (2+2) photocycloaddition of Nl-(w-butenyl)uracil and belongs to a (5.2.1.O5.10) tricyclic system. A pair of molecules related by the inversion symmetry are held together by the strong hydrogen bonding interactions between 02 and H3 of the uracil moiety.

  • PDF

Hip Arthroplasty Using the Bencox® Hip System: An Evaluation of a Consecutive Series of One Thousand Cases

  • Lee, Joong-Myung;Sim, Young-Suk;Choi, Dae-Sung
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.210-218
    • /
    • 2018
  • Purpose: This is a report on the outcomes associated with a consecutive series of 1,000 cementless hip arthroplasties utilizing the $Bencox^{(R)}$ hip stem-the first Korean-developed hip prosthesis. Materials and Methods: A consecutive series of 1,000 hip arthroplasties using the $Bencox^{(R)}$ hip stem were analyzed, starting from its initial release (September 2006) until June 2014. Patients in this consecutive series underwent surgery for fractures (n=552), arthritis (n=155), avascular necrosis (n=209), and revisions (n=84). Of these 1,000 cases, patients with a minimum follow-up of at least 1 year (n=616) were retrospectively analyzed for radiographic and clinical outcomes (i.e., Harris hip score). The stability of the prosthesis was evaluated by examining subsidence. Results: During the follow-up period (mean follow-up period of 54.8 months), there were 2 cases requiring revision of the femoral stem-both were caused by periprosthetic fractures and neither involved stem loosening. The mean Harris hip score during follow-up was 95.5. Bone ongrowth occurred in 95% of patients; no cases of subsidence or aseptic loosening of the stem were detected, and no cases of postoperative complications such as ceramic breakage were observed. Conclusion: Clinical and radiographic evaluations of hip arthroplasty using the $Bencox^{(R)}$ hip stem revealed excellent outcomes with an average of 54.8 month follow-up in a consecutive series of 1,000 cases.

Role of Endoscopic Ultrasound-Guided Fine-Needle Aspiration in the Evaluation of Abdominal Lymphadenopathy of Unknown Etiology

  • Nonthalee Pausawasdi;Kotchakon Maipang;Tassanee Sriprayoon;Phunchai Charatcharoenwitthaya
    • Clinical Endoscopy
    • /
    • v.55 no.2
    • /
    • pp.279-286
    • /
    • 2022
  • Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a standard procedure for obtaining tissue from lesions near the gastrointestinal lumen. However, there is a scarcity of information on the diagnostic performance of EUS-FNA for abdominal lymphadenopathy of unknown causes. To assess the accuracy of EUS-FNA in diagnosing abdominal lymphadenopathy of unknown etiology. Methods: The EUS records of patients with undiagnosed abdominal lymphadenopathy between 2010 and 2015 were reviewed. Results: A total of 42 patients were included in this study. Adequate specimens were obtained from 40 patients (95%). The final diagnoses were metastatic cancer (n=16), lymphoma (n=9), tuberculosis (n=8), inflammatory changes (n=6), and amyloidosis (n=1). For diagnosing malignancy, EUS-FNA had a sensitivity of 84.6%, specificity of 95.7%, positive predictive value of 91.7%, negative predictive value of 91.7%, and area under the receiver operating characteristic curve (AUROC) of 0.901. For the diagnosis of lymphoma, EUS-FNA was 100% accurate when combined with cytologic evaluation and immunohistochemical staining. The diagnostic sensitivity decreased to 75%, whereas the specificity remained 100%, for tuberculosis. The overall AUROC was 0.850. No procedure-related complications occurred. Conclusions: EUS-FNA showed high diagnostic performance for abdominal lymphadenopathy of unknown causes, especially malignancy, lymphoma, and tuberculosis. Therefore, it is a crucial diagnostic tool for this patient population.

An Epidemiological Study for Child Pedestrian Traffic Injuries that Occurred in School-zone (어린이 보호구역 내에서 발생한 6-14세 어린이들의 보행 중 교통사고에 대한 역학적 조사)

  • Shin, Min-Ho;Kweon, Sun-Seog
    • Journal of Preventive Medicine and Public Health
    • /
    • v.38 no.2
    • /
    • pp.163-169
    • /
    • 2005
  • Objectives: Pedestrian traffic injuries have been an important cause of childhood mortality and morbidity for decades. The aim of this study was to describe the epidemiological characteristics of child pedestrian traffic injuries that occurred during 2000 in one metropolitan city and its school-zones, and to determine the factors associated with those accidents. Methods: A cross-sectional study was performed in 2001. Police records were used to identify the cases of pedestrian injury. Children aged between 6 and 15 years, injured during road walking, were included in this study. A direct survey of the environmental factors within the school-zones in study area (n=116) was also performed. Self-administered questionnaires, via mail and telephone surveys, were used to assess the safety education programmes. The schools were divided into two groups according to the occurrence of pedestrian traffic injuries in their school-zone. Results: Pedestrian injuries (n=597) were found to account for 3.2% of all traffic injuries in the subject area. The epidemiological characteristics were not significantly different between genders. There were some significant risk factors within the environmental factors, such as local road (OR: 2.3, 95% CI=1.05-5.35), heavy traffic volume (OR: 2.2, 95% CI=1.00-5.04), poor visibility of speed-limit signs (OR: 2.8, 95% CI=1.25-6.42), no separation of pedestrian routes from cars (OR: 2.6, 95% CI=1.02-6.75) and barriers on the pedestrian routes (OR: 2.2, 95% CI=1.01-5.08). Only one factor, that of education in a safety-park (OR: 0.3, 95% CI=0.09-0.96), was significantly associated in the traffic and pedestrian safety education factors. Conclusion: Significant associations with pedestrian injury risk were identified in some of the modifiable environmental factors than in the educational factors.

Comparison of GPS/Levelling Geoid with PNU95 Geoid in Cheju Island (제주도의 GPS/Levelling 지오이드와 PNU95 지오이드)

  • Choi, Kwang-Sun;Park, Je-Hui;Hong, Sun-Hun
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.1
    • /
    • pp.13-24
    • /
    • 2000
  • In this study, GPS surveying at bench marks in Cheju Island and with these data, calculate GPS/Levelling geoid in Cheju area. And compare this geoid with PNU95 Geoid. The results are as follows : 1. The ellipsoidal height of each bench mark was measured ${\pm}3cm$ with accuracy in GPS surveying. 2. Calculated CPS/Levelling Geoid well represents the variations of Cheju terrain. The correlation formula between the geoid and elevation above sea level in Cheju area is as fellow : $$N\;=\;0.001082\;{\times}\;h\;+\;25.458\;{\pm}\;0.227\;s.d.$$ 3. Calculated GPS/Levelling Geoid and PNU95 Geoid are welt fitted and the RMS difference between the two Geoids is 0.14 m.

  • PDF