• Title/Summary/Keyword: N.D.C method

Search Result 794, Processing Time 0.031 seconds

An investigation on the in si·tu measurement of the oil-concentration with densimeter (밀도계를 이용한 비추출식 냉동기유농도 측정에 관한 연구)

  • Kim, S.H.;Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.31-37
    • /
    • 1999
  • In order to predict thermodynamic performance of refrigeration system, it is required to know the oil concentration of the refrigerant/oil mixture. The current method to measure the oil concentration is to extract the working mixture and then to measure the oil weight. However, it is Quite necessary to estimate oil concentration without any extraction of the working fluid. In this study a new method and working equation is presented as follows. It is based on the measurement of spedific gravity and temperature : $$C=a+b{\times}t+c{\times}t^2+(d+e{\times}t+f{\times}t^2){\times}SG$$ C is oil concentration, t is temperature($^{\circ}C$), SG is specific gravity of mixture and a~f is coefficients. The oil concentration ranges over 0~12 wt% and the temperature ranges over $20{\sim}50^{\circ}C$. The specific gravity and temperature are measured using the on-line densimeter and thermometer. This working equation enables to predict the oil concentration without any extraction of the mixture. This equation can be applied for R-12/Naphthenic oil and R-134a/POE oil oiquid mixtures.

  • PDF

In vitro study of fracture strength of provisional crown materials

  • Karaokutan, Isil;Sayin, Gulsum;Kara, Ozlem
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.27-31
    • /
    • 2015
  • PURPOSE. The purpose of this report was to evaluate the effect of the fabrication method and material type on the fracture strength of provisional crowns. MATERIALS AND METHODS. A master model with one crown (maxillary left second premolar) was manufactured from Cr-Co alloy. The master model was scanned, and the data set was transferred to a CAD/CAM unit (Yenamak D50, Yenadent Ltd, Istanbul, Turkey) for the Cercon Base group. For the other groups, temporary crowns were produced by direct fabrication methods (Imident, Temdent, Structur Premium, Takilon, Systemp c&b II, and Acrytemp). The specimens were subjected to water storage at $37^{\circ}C$ for 24 hours, and then they were thermocycled (TC, $5000{\times}$, $5-55^{\circ}C$) (n=10). The maximum force at fracture (Fmax) was measured in a universal test machine at 1 mm/min. Data was analyzed by non-parametric statistics (${\alpha}$=.05). RESULTS. Fmax values varied between 711.09-1392.1 N. In the PMMA groups, Takilon showed the lowest values (711.09 N), and Cercon Base showed the highest values (959.59 N). In the composite groups, Structur Premium showed the highest values (1392.1 N), and Acrytemp showed the lowest values (910.05 N). The composite groups showed significantly higher values than the PMMA groups (P=.01). CONCLUSION. Composite-based materials showed significantly higher fracture strengths than PMMA-based materials. The CADCAM technique offers more advantages than the direct technique.

Analysis of Sugar Chain Structure of PAS-7 Glycoprotein from Bovine Milk Fat Globule Membrane by US RAAM 2000 (OGS RAAM2000을 이용한 유지방구막 PAS-7 당단백질의 당쇄구조 해석)

  • 석진석
    • Food Science of Animal Resources
    • /
    • v.21 no.4
    • /
    • pp.367-373
    • /
    • 2001
  • Glycoproteins PAS-6(50 kDa) and -7(47 kDa) from the bovine milk fat globule membrane share a common protein core but differ in their carbohydrate moiety. We have analyzed and proposed the structures of the N-linked sugar chains of PAS-7 by Oxford Glyco System(OGS) RAAM2000. The N-linked sugar chains were liberated from PAS-7 by hydrazinolysis and, after modifying the reducing ends with 2-aminobenzamide(2-AB), were separated into one neutral(7N, 55%) and two acidic(7M, mono-, 43%; 7D, di-, 2%) sugar chain groups. 7N was finally separated into 5 chains(a, b, c, d, and e), respectively. The structure of this 2AB-neutral sugar chain was determined by sugar analysis, exoglycosidase digestion with OGS glycosidase Kit and OGS RAAM2000 system. The results show that fraction e was the same of reported 7N1A, the biantennary complex type with a fucose on reducing end and two N-acetyllactosamine branch on non-reducing end. Therefore, it was proved that OGS RAAM2000 method is in conformity with conventional analysis of sugar chain structure from bovine PAS-7.

  • PDF

Determination of Natural Gas Components by Gas Chromatographic Multicolumn System (기체 크로마토그래피 복합컬럼 시스템에 의한 천연가스 성분의 정량)

  • Choi, Yong-Wook;Choe, Kun-Hyung
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.339-347
    • /
    • 1994
  • A multicolumn system consisted of two valve(10-port and 6-port valve)-three column (28% DC 200, SP 1700 and Chromosorb 102 column) was developed. Nine natural gas components composed of $N_2$, $CH_4$, $CO_2$, $C_2H_6$, $C_3H_8$, $i-C_4H_{10}$, $n-C_4H_{10}$, $i-C_5H_{12}$$n-C_5H_{12}$ completed all the baseline separation within 18 minutes. The accuracy and the precision of this system was tested. The retention times and the peak areas were determined with a repeatability between 0.02 and 0.16%, and less than 1%, respectively. Calibration curves for natural-gas components were plotted by the partial pressure injection method of pure gases, and good linear relationships for each component were presented. By using these calibration curves the accuracy of the multicolumn system compaired with that of the single column system for a certified standard gas of natural gas. As a result, relative error in the single and the multicolumn system was less than 0.5% and 0.04%, respectively. The result of application of this system in the analysis of importing LNG composition showed that the heating values calculated by the multicolum system were estimated lower compared with those calculated by the single column system and consequently, the importing price of LNG was able to be cut down.

  • PDF

V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages ($SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성)

  • Lee, Bok-Hui;Lee, Gyeong-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF

3D micro-CT analysis of void formations and push-out bonding strength of resin cements used for fiber post cementation

  • Uzun, Ismail Hakki;Malkoc, Meral Arslan;Keles, Ali;Ogreten, Ayse Tuba
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.101-109
    • /
    • 2016
  • PURPOSE. To investigate the void parameters within the resin cements used for fiber post cementation by micro-CT (${\mu}CT$) and regional push-out bonding strength. MATERIALS AND METHODS. Twenty-one, single and round shaped roots were enlarged with a low-speed drill following by endodontic treatment. The roots were divided into three groups (n=7) and fiber posts were cemented with Maxcem Elite, Multilink N and Superbond C&B resin cements. Specimens were scanned using ${\mu}CT$ scanner at resolution of $13.7{\mu}m$. The number, area, and volume of voids between dentin and post were evaluated. A method of analysis based on the post segmentation was used, and coronal, middle and apical thirds considered separately. After the ${\mu}CT$ analysis, roots were embedded in epoxy resin and sectioned into 2 mm thick slices (63 sections in total). Push-out testing was performed with universal testing device at 0.5 mm/min cross-head speed. Data were analyzed with Kruskal-Wallis and Mann-Whitney U tests (${\alpha}=.05$). RESULTS. Overall, significant differences between the resin cements and the post level were observed in the void number, area, and volume (P<.05). Super-Bond C&B showed the most void formation ($44.86{\pm}22.71$). Multilink N showed the least void surface ($3.51{\pm}2.24mm^2$) and volume ($0.01{\pm}0.01mm^3$). Regional push-out bond strength of the cements was not different (P>.05). CONCLUSION. ${\mu}CT$ proved to be a powerful non-destructive 3D analysis tool for visualizing the void parameters. Multilink N had the lowest void parameters. When efficiency of all cements was evaluated, direct relationship between the post region and push-out bonding strength was not observed.

Understanding the Foreign Tech-Trend of Artificial Skin by the Analysis of Patents (특허정보분석을 통한 해외 인공피부 기술동향)

  • 이상필;강종석;이영무
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.85-98
    • /
    • 2004
  • The situation of technology Predominance and the distribution of core technology were visually mapped thorough the investigation of technical trend during 20 years, which was provided with the analysis of patent information for the artificial skin. Therefore, it was expected that technology mapping by means of multilateral analysis method allowed a good grasp of current technology trend of the artificial skin and the subdivision into nation and a field of research presents the direction of R&D. In the early R&D stage of artificial skin, the preparation technology of filters implantable into the living body including nursing devices, bandages, and dressings or absorbent pads (A6IF-002/10) was on the rise in research field of artificial skin until 1980's. And then the materials technology for coating prostheses (A6l L-027/00)was leading the core technology of artificial skin. Also, Nowadays the fusion technology connected the material technology with the cultivation technology of undifferentiated human or animal cells/tissues including culture media (C l2N-005/00, C 12N-005/06) was highlighted all over the world.

A STUDY OF CHINESE ANCIENT COMETARY RECORDS

  • ZHOU HONG NAN;ZHUANG WEIFENG;WANG Yu
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.443-444
    • /
    • 1996
  • From 146 B.C. to A.D. 1760, 363 sets of cometary observations have been recorded in Chinese Ancient Records of Celestial Phenomena. The positions of all recorded comets, or their paths, on the sky are compared. Taking into account the perturbations of all nine planets and using the numerical method of N-body problem, the orbits of well-recorded comets are calculated. Identification of a periodic comet is presented.

  • PDF