• Title/Summary/Keyword: N-section

Search Result 1,052, Processing Time 0.029 seconds

Analysis of Electrical Characteristics of AlGaN/GaN on Si Large SBD by Changing Structure

  • Lee, Hyun-Soo;Jung, Dong Yun;Park, Youngrak;Jang, Hyun-Gyu;Lee, Hyung-Seok;Jun, Chi-Hoon;Park, Junbo;Mun, Jae Kyoung;Ryu, Sang-Ouk;Ko, Sang Choon;Nam, Eun Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.3
    • /
    • pp.354-362
    • /
    • 2017
  • We investigated the improvement in electrical characteristics of large AlGaN/GaN on Si Schottky barrier diode (SBD) induced by structural change to achieve a better trade-off between the forward and reverse performance to obtain high power conversion efficiency in PFC converter. Using an optimized dry etch condition for a large device, we fabricated three-types of SBD with 63 mm channel width: conventional, recessed, recessed dual-anode-metal SBD. The recessed dual-anode-metal SBD exhibited a very low turn-on voltage of 0.34 V, a high forward current of 1.63 A at 1.5 V, a leakage current of $114{\mu}A$ at -15 V, a breakdown voltage of 794 V.

ETRI 0.25μm GaN MMIC Process and X-Band Power Amplifier MMIC (ETRI 0.25μm GaN MMIC 공정 및 X-대역 전력증폭기 MMIC)

  • Lee, Sang-Heung;Kim, Seong-Il;Ahn, Ho-Kyun;Lee, Jong-Min;Kang, Dong-Min;Kim, Dong Yung;Kim, Haecheon;Min, Byoung-Gue;Yoon, Hyung Sup;Cho, Kyu Jun;Jang, Yoo Jin;Lee, Ki Jun;Lim, Jong-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • In this paper, ETRI's $0.25{\mu}m$ GaN MMIC process is introduced and the fabricated results of X-Band 3 W power amplifier MMIC are discussed. The one-stage X-Band 3 W power amplifier MMIC using the $0.25{\mu}m$ GaN MMIC devices has been designed and fabricated. From the fabricated GaN MMIC, the characteristics of the $0.25{\mu}m$ GaN MMIC process and devices are evaluated and analyzed. The X-band power amplifier MMIC shows output power of 3.5 W, gain of 10 dB, and power-added efficiency of 35 %.

Isolation and Identification of Aspergillus Section Fumigati Strains from Arable Soil in Korea

  • Hong, Seung-Beom;Kim, Dae-Ho;Park, In-Cheol;Samson, Robert A.;Shin, Hyeon-Dong
    • Mycobiology
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • 63 strains of Aspergillus section Fumigati were isolated from 17 samples of arable soil in a central province of Korea. Based on the results of genotypic and phenotypic analyses, they were identified as Aspergillus fumigatus, A. lentulus, Neosartorya coreana, N. fennelliae, N. fischeri, N. glabra, N. hiratsukae, N. laciniosa, N. pseudofischeri, N. quadricincta, N. spinosa and N. udagawae. Among these, N. fennelliae, N. hiratsukae, N. quadricincta, and N. udagawae had not been previously recorded in Korea. The diversity of Aspergillus section Fumigati species from arable soil in Korea is also addressed.

0.25 μm AlGaN/GaN HEMT Devices and 9 GHz Power Amplifier (0.25 μm AlGaN/GaN HEMT 소자 및 9 GHz 대역 전력증폭기)

  • Kang, Dong-Min;Min, Byoung-Gue;Lee, Jong-Min;Yoon, Hyung-Sup;Kim, Sung-Il;Ahn, Ho-Kyun;Kim, Dong-Young;Kim, Hae-Cheon;Lim, Jong-Won;Nam, Eun-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.76-79
    • /
    • 2016
  • This paper describes the successful development and the performance of X-band 50 W pulsed power amplifier using a 50 W GaN-on-SiC high electron mobility transistor. The GaN HEMT with a gate length of $0.25{\mu}m$ and a total gate width of 12 mm were fabricated. The X-band pulsed power amplifier exhibited an output power of 50 W with a power gain of 6 dB in a frequency range of 9.2~9.5 GHz. It also shows a maximum output power density of 4.16 W/mm. This 50 W GaN HEMT and X-band 50 W pulsed power amplifier are suitable for the radar systems and related applications in X-band.

Formation of Ohmic Contact to AlGaN/GaN Heterostructure on Sapphire

  • Kim, Zin-Sig;Ahn, Hokyun;Lim, Jong-Won;Nam, Eunsoo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.292-292
    • /
    • 2014
  • Wide band gap semiconductors, such as III-nitrides (GaN, AlN, InN, and their alloys), SiC, and diamond are expected to play an important role in the next-generation electronic devices. Specifically, GaN-based high electron mobility transistors (HEMTs) have been targeted for high power, high frequency, and high temperature operation electronic devices for mobile communication systems, radars, and power electronics because of their high critical breakdown fields, high saturation velocities, and high thermal conductivities. For the stable operation, high power, high frequency and high breakdown voltage and high current density, the fabrication methods have to be optimized with considerable attention. In this study, low ohmic contact resistance and smooth surface morphology to AlGaN/GaN on 2 inch c-plane sapphire substrate has been obtained with stepwise annealing at three different temperatures. The metallization was performed under deposition of a composite metal layer of Ti/Al/Ni/Au with thickness. After multi-layer metal stacking, rapid thermal annealing (RTA) process was applied with stepwise annealing temperature program profile. As results, we obtained a minimum specific contact resistance of $1.6{\times}10^{-7}{\Omega}cm2$.

  • PDF

Measurement of Energy Dependent Differential Neutron Capture Cross-section of Natural Sm by Using a Continuous Neutron Flux below (연속에너지 중성자에 대한 천연 Sm의 중성자 포획단면적 측정)

  • Yoon, Jungran
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.337-341
    • /
    • 2016
  • We measured the neutron capture cross-section of natural Sm(n,${\gamma}$) reaction in the energy regions from 0.003 to 10 eV. The 46-MeV electron linear accelerator of Research Reactor Institute, Kyoto University was used for generating a continuous neutron source. The neutron time-of-flight method was adopted for energy measurement. An assembly of BGO($Bi_4Ge_3O_{12}$) scintillators composed of 12 pieces of BGO crystals measured prompt gamma rays from Sm(n,${\gamma}$) reaction. The BGO assembly was located at a distance of $12.7{\pm}0.02m$ from the neutron source. In order to determine the neutron flux impinging on the Sm, the $^{10}B(n,{\alpha}{\gamma})^7Li$ standard cross-section were used. Natural Sm(n,${\gamma}$) reaction measurement result of the neutron capture cross-section was compared with the results of evaluation of the BROND-2.2 and the previous experimental data of J. C. Chou and V. N. Kononov.

Differences of Cesarean Section Rates according to San-Yin-Jiao(SP6) Acupressure for Women in Labor (삼음교 지압에 따른 산부의 제왕절개율 차이)

  • 장순복;박용원;조재성;이미경;이병철;이수정
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.2
    • /
    • pp.324-332
    • /
    • 2004
  • Purpose: The purpose of this study was to explain differences of cesarean section rates according to San- Yin-Jiao(SP6) acupressure for women in labor. Method: A noneqivalent control group pre test - post test design was used to explain differences of cesarean section rates according to SP6 acupressure. The participants were 209 women who were assigned to one of three groups SP6 acupressure(n=86), SP6 touch(n=47), and control group(n=76). For 30 minutes, the SP6 acupressure group received SP6 acupressure, and the SP6 touch group received SP6 touch for the duration of each uterine contraction. The Control group was encouraged to deep breath and relax for the duration of each uterine contraction for 30 minutes. Result: The rates of cesarean section were 12.8%, 29.8%, and 22.4% for the SP6 acupressure group, SP6 touch group, and control group respectively. There was a significant difference among groups (p=0.049). Cesarean section rateswere significantly different between the SP6 acupressure and non-SP6 acupressure group(p=0.035). Conclusion: This finding shows that 30 minutes of SP6 acupressure was effective in decreasing the cesarean section rate. Therefore, SP6 acupressure during labor could be applied as an effective nursing intervention.

A Study on the Structural Performance and the Design of Propeller Root Fillet Surfaces having nT-T/n section (nT-T/n 단면형상을 갖는 프로펠러 뿌리 필렛의 구조 성능 분석과 설계방안에 관한 연구)

  • Ruy, Won-Sun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.5
    • /
    • pp.372-379
    • /
    • 2015
  • The blade root fillets which have strong influences on the performance of propellers in the both structural and hydrodynamic points of view, are mechanical parts for smooth connection surface with a blade and a hub. A few related researches (Sabol, 1983; Kennedy, 1997) have noted that 3T-T/3 double radius section design would be suitable for reducing Stress Concentration Factor(SCF) and increasing Cavitation Inception Speed(CIS). In this paper, it is confirmed that this compound cross-section design has come close to the optimum solution in the shape optimization standpoint so that it could protect the propeller blade under the frequent and various loading cases. On that basis, we suggest the definite and simple fillet design methodology that has the cross-section with nT-T/n compound radius and elliptic shape which could sustain the given derivatives information as well as the offsets at the boundary and all inner region of the fillet surface. In addition, the result of design is presented in form of IGES file format in order to connect with NC machine seamlessly.

Evaluation of Tracheobronchial Diseases: Comparison of Different Imaging Techniques

  • Qihang Chen;Jin Mo Goo;Joon Beom Seo;Myung Jin Chung;Yu-Jin Lee;Jung-Gi Im
    • Korean Journal of Radiology
    • /
    • v.1 no.3
    • /
    • pp.135-141
    • /
    • 2000
  • Objective: To compare the clinical utility of the different imaging techniques used for the evaluation of tracheobronchial diseases. Materials and Methods: Forty-one patients with tracheobronchial diseases [tuberculosis (n = 18), bronchogenic carcinoma (n = 10), congenital abnormality (n = 3), post-operative stenosis (n = 2), and others (n = 8)] underwent chest radiography and spiral CT. Two sets of scan data were obtained: one from routine thick-section axial images and the other from thin-section axial images. Multiplanar reconstruction (MPR) and shaded surface display (SSD) images were obtained from thin-section data. Applying a 5-point scale, two observers compared chest radiography, routine CT, thin-section spiral CT, MPR and SSD imaging with regard to the detection, localization, extent, and characterization of a lesion, information on its relationship with adjacent structures, and overall information. Results: SSD images were the most informative with regard to the detection (3.95±0.31), localization (3.95±0.22) and extent of a lesion (3.85±0.42), and overall information (3.83±0.44), while thin-section spiral CT scans provided most information regarding its relationship with adjacent structures (3.56±0.50) and characterization of the lesion (3.51±0.61). Conclusion: SSD images and thin-section spiral CT scans can provide valuable information for the evaluation of tracheobronchial disease.

  • PDF

Neutron Cross Section Evaluation on Dy Isotopes

  • Lee, Y. D.;J. H. Chang
    • Nuclear Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.154-164
    • /
    • 2002
  • Neutron cross section data on Dy-160, Dy-161, Dy-162, Dy-163 and Dy-164 were calculated and evaluated in the energy range of 1 keV to 20 MeV using a spherical optical model, statistical model and pre-equilibrium model. The energy dependent optical model potential parameters were obtained based on the recent experimental data. The width fluctuation correction in Hauser-Feshbach particle decay and the quantum mechanical approach in pre-equilibrium analysis were introduced and gave a better cross section calculation in EMPIRE-II. The total, elastic scattering and threshold reaction cross sections were evaluated and compared with the evaluated files. The model calculated (n, tot), (n, ${\gamma}$) and (n, p) cross sections were in good agreement with the experimental data in the measured energy range. The results will be applied to ENDF/B-VI for data improvement.