• Title/Summary/Keyword: N-methyl-N-tert.-butyldimethylsilyl trifluoroacetamide(MTBSTFA)

Search Result 3, Processing Time 0.023 seconds

Gas-chromatographic determination of methylthiohydantoin amino acid as N(O)-butyldimethylsilyl derivatives in amino acid sequencing with methylisothiocyanate (Methylisothiocyanate를 이용한 아미노산 배열결정시 N(O)-butyldimethylsilyl 유도체로서의 methylthiohydantoin 아미노산의 기체 크로마토그래피에 의한 분석)

  • Woo, Kang-Lyung
    • Applied Biological Chemistry
    • /
    • v.35 no.2
    • /
    • pp.132-138
    • /
    • 1992
  • For effective determination of methylthiohydantoin amino acids(MTHs) by gas liquid chromatography in the protein sequencing, derivatization with N-methyl-N-(tert.-butyl-dimethylsilyl)trifluoroacetamide(MTBSTFA), a new silylating reagents, was attempted instead of trimethylsilyl(TMSi) derivatives by N,O-bis(trimethylsilyl)trifluoroacetamide(BSTFA) used up to the present and N(O)-butyldimethylsilyl MTHs derivatized by MTBSTFA were analysed on HP-1 capillary column. Twenty one protein amino acids except cystine were indentified. Especially arginine that did not detected with TMSi derivative on packed column until now was resolved by derivatization with MTBSTFA. N(O)-butyldimethylsilyl MTHs showed multiple peaks by MTBSTFA were proline, isoleucine, glycine and tyrosine and hydroxyproline especially showed several extraneous peaks more than two. Calibration curves of N(O)-butyldimethysilyl MTHs of amino acids in the range of $2.5\;nmol{\sim}7.5\;nmole$ showed good linearity. however, those of lysine, histidine and arginine showed linearity in the range of $5.0\;nmole{\sim}15.0\;nmole$. Correlation coefficients and regression coefficients of all calibration curves were highly significant(p<0.001).

  • PDF

Determination of the PDE-5 Inhibitors and Their Analogues by GC-MS and TMS Derivatization

  • Pyo, Jae-Sung;Lee, Hee-Sang;Park, Yu-Jin;Jo, Ji-Yeong;Park, Yong-Hoon;Choe, Sang-Gil;Lee, Mi-Young;Lee, Jae-Sin
    • Mass Spectrometry Letters
    • /
    • v.3 no.1
    • /
    • pp.15-17
    • /
    • 2012
  • Eighteen of the PDE-5 inhibitors and their analogues were analyzed using GC-EI-MS. Fourteen of them could be identified by simple GC-MS method without derivatization, but hydroxyhongdenafil, hydroxyvardenafil, xanthoanthrafil and mirodenafil could not be identified without derivatization for the high polarity due to the presence of hydroxyl groups. N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) and N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA), widely used trimethylsilyl (TMS) derivatizing reagents, were used to improve the sensitivity of the hydroxylated analogues. And the analytes could be identified by GC-MS after the derivatization.

Comparison of the Analytical Method for 3-Monochloropropane-l,2-diol in Food (식품 중 3-monochloropropane-1,2-diol의 분석법 비교 연구)

  • Yoo, Seung-Seok;Oh, Chang-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.360-365
    • /
    • 2007
  • The studies for the derivatization of 3-monochloropropane-1,2-diol (3-MCPD) were performed mainly as acylation with HFBI (heptafluorobutyrylimidazole), alkylation with PBA (phenylboric acid) and silylation with BSTFA (N,O-bis[trimethylsilyl]trifluoroacetamide). Also silylation with MTBSTFA(N-methyl-N-[tert.-butyldimethylsilyl] trifluoroacetamide) and acylation with MBTFA (N-Methyl-bis[trifluoro-acetamide]) were also considered. Except the TBDMS derivative of 3-MCPD, all the derivatives were detected well. The derivatives of 3-MCPD with HFBI, PBA and BSTFA showed below 10 ${\mu}g/kg$ which was sensitive enough to satisfy Korea maximum residue limit 0.3 mg/kg. Among the tested adsorbents, Extrelut20 and Florisil were evaluated as the proper adsorbents to eliminate the soy sauce matrix for 3-MCPD. Ethyl acetate was the most efficient eluent with good recovery rate. The desired surrogate compound and internal standard were 1,2-butanediol and 1,2-dibromo-3-chloropropane, respectively. The limit of detection for PB-MCPD and TMS-MCPD were 10.16 and 7.06 ${\mu}g/kg$ on GC/MSD, respectively. HFB-MCPD derivative showed the lowest detection limits 2.98 and 5.32 ${\mu}g/kg$ by GC/ECD and GC/MSD, respectively.