• Title/Summary/Keyword: N-ideal

Search Result 616, Processing Time 0.023 seconds

Effect of Body Image and Eating Attitude on Depressive Mood and Suicide Ideation in Female Adolescents (여자 청소년의 신체이미지와 식사태도가 우울감과 자살사고에 미치는 영향)

  • Song, Man-Kyu;Ha, Jee-Hyun;Park, Doo-Heum;Ryu, Seung-Ho;Oh, Jung-Hyeon;Yu, Jae-Hak
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.18 no.1
    • /
    • pp.40-47
    • /
    • 2010
  • Objectives:Body image is closely related to self-esteem and weight-control related behaviors. In particular, relationship between two factors would be stronger in female adolescents. False recognition on body image and weight can be a risk factor of eating disorder, depression, and suicidal ideation. This study aimed to examine the effects of body image and eating disorders on developing depressive symptoms and suicidal ideation in female adolescents. Methods:Two hundred thirty nine students of a Girls' Commercial High School in Seoul were recruited. Eating Attitude Test for Korean Adolescents, Self-Esteem Scales, Impulsiveness Scale, Beck's Depression Inventory and Beck's Suicidal Ideation Scale were used to measure eating attitude and severity of psychiatric symptoms. Results:Among 239 subjects, the estimated risk group of eating disorders was 10%(n=24). They experienced more depressive symptoms than the control group. The bigger discrepancy in current and ideal body mass index was significantly related with higher depressive mood, suicidal idea, abnormal eating habits and lower self-esteem. Discrepancy between current and idea BMI was the most meaningful predictive factor about depression and suicidal thoughts by linear regression analysis. Conclusion:In spite of normal weight range of enrolled subjects, they experienced significant depressive mood, suicide thoughts and lower self-esteem associated with the discrepancy of their own subjective body image and current body mass index. Hence educational approach regarding normal body image and healthy weight control is needed for their mental health and preventing eating disorder.

  • PDF

The Study on Analysis Method and Performance Evaluation of Portable GC/MS (휴대용 GC/MS 성능검사 및 분석방법 연구)

  • Park, Yuonshin;Noh, Hyeran;Yang, Heeseon;Seok, Gwanseol
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.249-258
    • /
    • 2013
  • Recieved Mar. 06, 2013 Revised Mar. 29, 2013 Accepted Sep. 11, 2013In this study, we evaluated the method performance and the optimum sample injection method of the portable GC/MS(HAPSITE) which were designed to operate on scene of chemical accidents. Chemicals used for performance test were vinyl chloride(VC), methyl chloride(MC), benzene(Bz), toluene(Tol). CRM(Certified Reference Material) Manufactured by KRISS(Korea Research Institute of Standards and Science) was used as the standard gas. The results showed that 1) Among three sample injection methods(Cylinder, Silico canister, and Bag), bag was identified as the most appropriate sample injection method. Bag material and capacity did not significantly affect the results. The most ideal reproducibility occurred at the 2-minute point of the purge time in the loop and tenax methods. 2) Performance evaluation of HAPSITE was conducted. Evaluation items were reproducibility, linearity, method detection limit, etc. Tenax concentration method was appropriate for larger molecules and Carbopack concentration method was suitable for smaller molecules.

A STUDY ON COMPARISON OF VARIOUS KINDS OF CLASSII AMALGAM CAVITIES USING FINITE ELEMENT METHOD (유한요소법을 이용한 수종 2급 아말감 와동의 비교연구)

  • Seok, Chang-In;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.432-461
    • /
    • 1995
  • The basic principles in the design of Class II amalgam cavity preparations have been modified but not changed in essence over the last 90 years. The early essential principle was "extension for prevention". Most of the modifications have served to reduce the extent of preparation and, thus, increase the conservation of sound tooth structure. A more recent concept relating to conservative Class II cavity preparations involves elimination of occlusal preparation if no carious lesion exists in this area. To evaluate the ideal ClassII cavity preparation design, if carious lesion exists only in the interproximal area, three cavity design conditions were studied: Rodda's conventional cavity, simple proximal box cavity and proximal box cavity with retention grooves. In this study, MO amalgam cavity was prepared on maxillary first premolar. Three dimensional finite element models were made by serial photographic method. Linear, eight and six-nodal, isoparametric brick elements were used for the three dimensional finite element model. The periodontal ligament and alveolar bone surrounding the tooth were excluded in these models. Three types model(B option, Gap option and R option model) were developed. B option model was assumed perfect bonding between the restoration and cavty wall. Gap option model(Gap distance: $2{\mu}m$) was assumed the possibility of play at the interface simulated the lack of real bonding between the amalgam and cavity wall (enamel and dentin). R option model was assumed non-connection between the restoration and cavty wall. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed the displacement, 1 and 2 direction normal stress and strain with FEM software ABAQUS Version 5.2 and hardware IRIS 4D/310 VGX Work-station. The results were as followed. 1. Rodda's cavity form model showed greater amount of displacement with other two models. 2. The stress and strain were increased on the distal marginal ridge and buccopulpal line angle in Rodda's cavity form model. 3. The stress and strain were increased on the central groove and a part of distal marginal ridge in simple proximal box model and proximal box model with retention grooves. 4. With Gap option, Rodda's cavity form model showed the greatest amount of the stress on distal marginal ridge followed by proximal box model with retention grooves and simple proximal box model in descending order. 5. With Gap option, simple proximal box model showed greater amount of stress on the central groove with proximal box model with retention grooves. 6. Retention grooves in the proximal box played the role of supporting the restorations opposing to loads.

  • PDF

A Study of Proposing Standard for Traffic Signal Warrants Corresponding to Traffic Volumes (교통량에 따른 교통신호기 설치 기준 안에 관한 연구)

  • 박용진;장덕명;김기혁
    • Journal of Korean Society of Transportation
    • /
    • v.15 no.4
    • /
    • pp.73-90
    • /
    • 1997
  • The warrants to install traffic signals used in U.S.A. are well specified comparing to those in other countries. Among the eleven warrants of the U.S.A., the Warrant 9, 10, and 11 are especially fit in practice. The warrant relaxed to traffic volumes used presently in Korea have been adopted from the U.S.A. Those may not have been reliable in the traffic situation of Korea. The rules required passing through intersections are not kept well at intersections controlled without signals. The purposes of this study are to test and evaluate the reliability of the Warrant 9 and 11 adopted form U.S.A.n Korean traffic situation and to propose new traffic signal warrants related to traffic volumes fitted in here. The traffic volume warrants are proposed considering the situation of rules not being kept well(current situation) and that of vice versa(ideal situation). The results of this study are following; 1) The total volumes warranted to traffic signals are 1600vph, 1700vph, and 1800vph at 4-legs intersection having 1 by 1 lane, 1 by 2 lanes, and 2 by 2 lanes respectively. The total volumes warranted are 1400vph and 1600vph at 3-legs intersection haying 1 by 2 1anes, and 2 by 2 lanes respectively. 2) Another traffic warrants proposed are transformed from the currant warrants 9 and 11. These warrants are composed of the total volumes and the ratio of the volume of the minor street to that of the major street.

  • PDF

The Sampling Efficiencies of Volatile Organic Compounds(VOCs) to the Diffusive Monitor with Activated Carbon Fiber (활성탄섬유를 이용한 확산포집기의 공기 중 유기용제 포집효율에 관한 연구)

  • Byeon, Sang-Hoon;Park, Cheon-Jae;Oh, Se-Min;Lee, Chang-Ha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.187-201
    • /
    • 1996
  • This study was to evaluate the efficiency of diffusive monitor using activated carbon fiber(ACF, KF-1500) in measuring airborne organic solvents. The following characteristics were identified and studied as critical to the performance of diffusive monitor; recovery, sampling rate, face velocity, reverse diffusion and storage stability. For the evaluation of the performance of this monitor, MIBK, PCE, toluene were used as organic solvents. In the sampling rate experiments, eight kinds of solvents (n-hexane, MEK, DIBK, MCF, TCE, CB, xylene, cumene) as well as the above solvents were used. The results were as follows: 1. The desorption efficiencies(DE's) of ACF diffusive monitor ranged from 83 % to 101 %. In contrast, those of coconut shell charcoal ranged from 78 % to 102 %. Especially, the DE's of ACF for the polar solvents such as MEK were superior to those of charcoal. 2. Experimental sampling rates on ACF were average 42ml/min(37-46ml/min) for 11 organic solvents at $24{\pm}2^{\circ}C$, $50{\pm}5%RH$. However ideal sampling rates(DA/L) were 33 % higher than experimental sampling rates. 3. The initial response(15~16 min) of the testing monitor was 2 times higher than the actual concentration determined by the reference methods at $24{\pm}2^{\circ}C$, $8{\pm}5%RH$ and $80{\pm}5%RH$. Within 1 hours, the curve reached a linear horizontal line at low humidity condition. But sampling efficiencies decreased with respect to time at high humidity condition. And sampling efficiencies were higher at high humidity condition than low humidity condition for MIBK. 4. At very low velocity (less than 0.02 m/sec), the concentration of ACF diffusive monitor were poorly estimated. But ACF diffusive monitor were not affected at higher velocity(0.2 m/sec-0.6 m/sec). 5. There was no significant reverse diffusion when the ACF monitors were exposed to clean air for 2 hours after being exposed for 2 hours at the level of 1 TLV. 6. There was no significant sample loss during 3 weeks of storage at room temperature and 5 weeks of storage at refrigeration.

  • PDF

Anaerobic Organic Wastewater Treatment and Energy Regeneration by Utilizing E-PFR System (E-PER 반응기를 이용한 유기성 폐기물의 혐기성 처리와 재생에너지 생산에 관한 연구)

  • Kim, Burmshik;Choi, Hong-Bok;Lee, Jae-Ki;Park, Joo Hyung;Ji, Duk Gi;Choi, Eun-Ju
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.2
    • /
    • pp.57-65
    • /
    • 2008
  • Wastewater containing strong organic matter is very difficult to treat by utilizing general sewage treatment plant. but the wastewater is adequate to generate biomass energy (bio-gas; methane gas) by utilizing anaerobic digestion. EcoDays Plug Flow Reactor (E-PFR), which was already proved as an excellent aerobic wastewater treatment reactor, was adapted for anaerobic food wastewater digestion. This research was performed to improve the efficiency of bio-gas production and to optimize anaerobic wastewater treatment system. Food wastewater from N food waste treatment plant was applied for the pilot scale experiments. The results indicated that the efficiency of anaerobic wastewater treatment and the volume of bio-gas were increased by applying E-PFR to anaerobic digestion. The structural characteristics of E-PFR can cause the high efficiency of anaerobic treatment processes. The unique structure of E-PFR is a diaphragm dividing vertical hydraulic multi-stages and the inversely protruded fluid transfer tubes on each diaphragm. The unique structure of E-PFR can make gas hold-up space at the top part of each stage in the reactor. Also, E-PFR can contain relatively high MLSS concentration in lower stage by vertical up-flow of wastewater. This hydraulic flow can cause high buffering capacity against shock load from the wastewater in the reactor, resulting in stable pH (7.0~8.0), relatively higher wastewater treatment efficiency, and larger volume of bio-gas generation. In addition, relatively longer solid retention time (SRT) in the reactor can increase organic matter degradation and bio-gas production efficiency. These characteristics in the reactor can be regarded as "ideal" anaerobic wastewater treatment conditions. Anaerobic wastewater treatment plant design factor can be assessed for having 70 % of methane gas content, and better bio-gas yielding and stable treatment efficiency based on the results of this research. For example, inner circulation with generated bio-gas in the reactor and better mixing conditions by improving fluid transfer tube structure can be used for achieving better bio-gas yielding efficiency. This research results can be used for acquiring better improved regenerated energy system.

  • PDF

Lung Preservation Study for Above 20 Hours of LPDG Solution in Canine Lung Allotransplactation (폐이식 실험견에서 LPDG용액을 이용한 20시간 이상 폐보존효과 관찰)

  • Park, Chang-Gwon;Gwon, Geon-Yeong;Yu, Yeong-Seon
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.949-960
    • /
    • 1997
  • Background. Limited ischemic tolerance of the lung has remained one of the factors that limits the expansion of pulmonary transplantation as a treatment for end-stage pulmonary disease. Numerous studies on safe long term preservation for lung transplantation has been performed for the purpose of developing ideal preservation solution with extracellular type or intracellular type solutions. In this. study, we examined the efficacy of L DG solution in lung preservation longer than 20 hours by comparison with modified Euro-Collins solution. Iwethods. Thirty-(our adult mongrel dogs were divided into two groups. Donor lungs were flushed with LPDG solution(n=9) or modified Euro-Collins(MEC) solution(n=8) and stored for 24 hours at 1$0^{\circ}C$. All donor lungs were perfused through the pulmonary arteries with solutions containing prostaglandin El and verapamil. Left canine lung allotransplantations wereperformed. Assessment(hemodynamic indices and arterial blood gas analysis) of left implanted lung was made by occluding the right pulmonary artery for ten minutes using pulmonary artery Cuff. Assessment was repeated at the interval of 30 minutes, one hour, and two hours later after reperfusion and then chest X-ray, computed tomogram and lung perfusion scan were obtained. In survival dogs follow-up studies were done with assessment with chest X-ray, computed tomogram of the chest and lung perfusion scan on 7th day postoperatively. After preservation above 20 hours, pathological examinations for ultrastructural findings on right lung were performed in each group. Results. With respect to arterial oxygen tension, LPDG group was superior to MEC but there was no statistical significance for 2 hours after reperfusion. Mean pulmonary artery pressure was less increased(p < 0.05) and cardiac output higher(p <0.05) than MEC group until 2 hours after reperfusion. After 2 hours of reperfusion, both groups showed transplanted lung function deteriorated gradually. Perfusion scan of the transplanted lung in LPDG group showed better perfusion rate in immediate post-reperfusion, 3 days and 7 days later respectively but there was no statistical significance and corelation with PaO2 and computed tomoRravhic views. In scanning electron microscopy of pulmonary artery after preservation, LPDG group relatively shows less irregular protrusion of the inner surface of endothelial cell of poulmonary artery than MEC group. Conclusions, e concluded that LPDG solution can offer safe lung preservation above 20 hours with adequate immunosuppressive therapy and prevention of the infection.

  • PDF

Clinical Application of Compressed Spectral Array During Deep Hypothermia (초저체온하 대동맥수술 환자에서 완전 순환차단의 안전한 체온 및 기간에 대한 연구 - 뇌파 Compressed Spectral Array의 임상적 응용 -)

  • 장병철;유선국
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.752-759
    • /
    • 1997
  • Profound hypothermia protects . cerebral function during total circulatory arrest(TCA) in the surgical treatment of a variety of cardiac and aortic diseases. Despite its importance, there is no ideal technique to monitor the brain injury from ischemia. Since 1994, we have developed compressed spectral array(CSA) of electroencephalography(EEG) and monitored cerebral activity to reduce ischemic injury. The purposes of this study are to analyse the efficacy of CSA and to establish objective criteria to consistently identify the safe level of temperature and arrest time. We studied 6 patients with aortic dissection(AD, n=3) or aortic arch aneurysm(n=3, ruptured in 2). Body temperatures from rectum and esophagus and the EEG were monitored continuously during cooling and rewarming period. TCA with cerebral ischemia was performed in 3 patients and TCA with selective cerebral perfusion was performed in 3 patients. Total ischemic time was 30, 36 and 56 minutes respectively for TCA group and selective perfusion time was 41, 56 and 92 minutes respectively for selective perfusion group. The rectal temperatures for flat EEG were between 16.1 and 22. $1^{\circ}C$ (mean: 18.4 $\pm$ 2.0): the esophageal temperatures between 12.7 and $16.4^{\circ}C$ (mean $14.7\pm1.6).$ The temperatures at which EEG reappeared $5~15.4^{\circ}C$ for esophagus. There was no neurological defic t and no surgical mortality in this series. In summary, the electrical cerebral activity Teappeared within 23 minutes at the temperature less than $16^{\circ}C$ for rectum. It seemed that $15^{\circ}C$ of esophageal temperature was not safe for 20 minutes of TCA and continuous monitoring the EEG with CSA to identify the electrocerebral silence was useful.

  • PDF

Effect of Supplementation of Fermented Milk Containing Active Peptides(IPP, VPP) in Accordance with Medical Nutrition Therapy in Pre- and Hypertension Subjects (고혈압 전단계 및 고혈압 환자에서 의학영양치료와 병행한 생리활성 펩티드 함유 유산균 발효유 섭취가 혈압에 미치는 영향)

  • Kim, Ji-Young;Kim, Yun-Young;Kim, Hye-Rang;Yun, Sung-Seob;Kim, Wan-Sik;Yea, Hyun-Soo;Chung, Jin-Young;Lee, In-Hoe;Choue, Ryo-Won
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.18 no.6
    • /
    • pp.918-926
    • /
    • 2008
  • It is well known non-drug therapy for hypertension patients can reduce blood pressure. These types of therapy include maintaining ones ideal body weight, quitting smoking, consuming large amounts of fruits and vegetables consuming low levels of saturated fat and salt and regular exercise. Fermented milk protein derived biologically active peptides such as isoleucine-proline-proline_(IPP) or valine-proline-proline_(VPP) have been shown to lower blood pressure in hypertensive subjects. This study was conducted to investigate the antihypertensive effects of medical nutritional therapy _(MNT) in accordance with the consumption of fermented milk enriched with IPP and VPP. To accomplish this, we conducted a randomized case-controlled study of 43 subjects who had blood pressure levels greater than 120/80 mmHg. The subjects in the study group were randomly allocated into two groups, an MNT + fermented milk (100mL/day) group (n=21) and an MNT+L. helveticus fermented milk with tripeptides (IPP=2.2mg, VPP=2.6mg/100mL) group (n=22). The MNT included weight management, reduction of sodium, total fat and saturated fat intake, increased intake of fruits and vegetables, and increased intake of low fat dairy products. The treatments were administered for 12 weeks during which time no drug interventions were conducted. The daily intakes of total calories, fats, cholesterol and Na decreased significantly after 12 weeks of MNT in the control and the experimental groups. In addition, the systolic blood pressure de creased significantly in the control and experimental groups; however, the diastolic blood pressure only decreased significantly in the experimental group. Overall, the results of this study indicate that the intake of fermented milk containing IPP and VPP in conjunction with MNT exerted positive effects on the blood pressure of pre- and hypertensive subjects.

  • PDF

Posterior Lumbar Interbody Fusion Using Posterolateral Placement of A Single Cylindrical Threaded Cage and Two Regular Cages : A Biomechanical Study (단일 나사형 Cage를 이용한 후방 요추체간 융합술과 두개의 나사형 Cage를 이용한 PLIF의 생체 역학적 비교)

  • Park, Choon Keun;Hwang, Jang Hoe;Ji, Chul;Kwun, Sung Oh;Sung, Jae Hoon;Choi, Seung Jin;Lee, Sang Won;Kim, Moon Kyu;Park, Sung Chan;Cho, Kyeung Suok;Park, Chun Kun;Yuan, Hansen;Kang, Joon Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.7
    • /
    • pp.883-890
    • /
    • 2001
  • Objectives : An in vitro biomechanical study of posterior lumbar interbody fusion(PLIF) with threaded cage using two different approaches was performed on eighteen functional spinal units of bovine lumbar spines. The purpose of this study was to compare the segmental stiffnesses among PLIF with one long posterolateral cage, PLIF with one long posterolateral cage and simultaneous facet joint fixation, and PLIF with two posterior cages. Methods : Eighteen bovine lumbar functional spinal units were divided into three groups. All specimens were tested intact and with cage insertion. Group 1(n=12) had a long threaded cage($15{\times}36mm$) inserted posterolaterally and oriented counter anterolaterally on the left side by posterior approach with left unilateral facetectomy. Group 2(n=6) had two regular length cages($15{\times}24mm$) inserted posteriorly with bilateral facetectomy. Six specimens from group 1 were then retested after unilateral facet joint screw fixation in neutral(group 3). Likewise, the other six specimens from group 1 were retested after fixation with a facet joint screw in an extended position(group 4). Nondestructive tests were performed in pure compression, flexion, extension, lateral bending, and torsion. Results : PLIF with a single cage, group 1, had a significantly higher stiffnesses than PLIF with two cages, group 2, in left and right torsion(p<0.05). Group 1 showed higher stiffness values than group 2 in pure compression, flexion, left and right bending but were not significantly different. Group 3 showed a significant increase in stiffness in comparison to group 1 for pure compression, extension, left bending and right torsion(p<0.05). For group 4, the stiffness significantly increased in comparison to group 1 for extension, flexion and right torsion(p<0.05). Although there was no significant difference between groups 3 and 4, group 4 had increased stiffness in extension, flexion, right bending and torsion. Conclusion : Posterior lumbar interbody fusion with a single long threaded cage inserted posterolaterally with unilateral facetectomy enables sufficient decompression while maintaining a majority of the posterior elements. In combination with a facet joint screw fixation, adequate postoperative stability can be achieved. We suggest that posterolateral insertion of a long threaded cage is biomechanically an ideal alternative to PLIF.

  • PDF