• Title/Summary/Keyword: N-heptane

Search Result 188, Processing Time 0.025 seconds

Numerical Investigation of Exhaust Gas Recirculation Effect under Boost Pressure Condition on Homogeneous Charge Compression Autoignition (HCCI엔진의 과급조건에서 EGR영향에 대한 수치해석적 연구)

  • Oh, Chung Hwan;Jamsran, Narankhuu;Lim, Ock Tack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.451-464
    • /
    • 2014
  • This study used numerical methods to investigates investigate the exhaust gas recirculation (EGR) effect under the condition of boost pressure condition on a homogeneous charge compression ignition (HCCI) combustion engine using numerical methods. The detailed chemical-kinetic mechanisms and thermodynamic parameters for n-heptane, iso-octane, and PRF50 from the Lawrence Livermore National Laboratory (LLNL) are were used for this study. The combustion phase affects the efficiency and power. To exclude these effects, this study decided to maintain a 50 burn point (CA50) at 5 CA after top dead center aTDC. The results showed that the EGR increased, but the low temperature heat release (LTHR), negative temperature coefficient (NTC), and high temperature heat release (HTHR) were weakened due by theto effect of the O2 reduction. The combined EGR and boost pressure enhanced the autoignition reactivity, Hhence, the LTHR, NTC, and HTHR were enhanced, and the heat-release rate was increased. also In addition, EGR decraeased the indicated mean effective pressure (IMEP), but the combined EGR and boost pressure increased the IMEP. As a results, combining the ed EGR and boost pressure was effective to at increase increasing the IMEP and maintaining the a low PRR.

Conversion of NOx by Plasma-hydrocarbon Selective Catalytic Reduction Process (플라즈마-탄화수소 선택적 촉매환원공정을 이용한 질소산화물 저감 연구)

  • Jo, Jin-Oh;Mok, Young Sun
    • Applied Chemistry for Engineering
    • /
    • v.29 no.1
    • /
    • pp.103-111
    • /
    • 2018
  • A plasma-catalytic combined process was used as an attempt to improve the conversion efficiency of nitrogen oxides ($NO_x$) over a wide temperature range ($150{\sim}500^{\circ}C$) to cope with the exhaust gas whose temperature varies greatly. Since the catalytic $NO_x$ reduction is effective at high temperatures where the activity of the catalyst itself is high, the $NO_x$ reduction was carried out without plasma generation in the high temperature region. On the other hand, in the low temperature region, the plasma was created in the catalyst bed to make up for the decreased catalytic activity, thereby increasing the $NO_x$ conversion efficiency. Effects of the types of catalysts, the reaction temperature, the concentration of the reducing agent (n-heptane), and the energy density on $NO_x$ conversion efficiency were examined. As a result of comparative analysis of various catalysts, the catalytic $NO_x$ conversion efficiency in the high temperature region was the highest in the case of the $Ag-Zn/{\gamma}-Al_2O_3$ catalyst of more than 90%. In the low temperature region, $NO_x$ was hardly removed by the hydrocarbon selective reduction process, but when the plasma was generated in the catalyst bed, the $NO_x$ conversion sharply increased to about 90%. The $NO_x$ conversion can be maintained high at temperatures of $150{\sim}500^{\circ}C$ by the combination of plasma in accordance with the temperature change of the exhaust gas.

The analysis of endocrine distruptors in commercial cosmetics (유통 화장품 중 내분비계 장애물질 탐색 및 규명에 관한 연구)

  • Koo, Heesoo;Na, Youngran;Lee, Seungju;Min, Sangkee;Kang, Jungmi;Jin, Sung Hyun
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.212-220
    • /
    • 2015
  • This study aims to identify the characteristics of phthalates (DMP, DEP, DBP, DEHA, BBP, DEHP, and DNOP) and heavy metals such as lead (Pb), cadmium (Cd), and mercury (Hg) in cosmetics and their containers. Phthalates and heavy metals may be endocrine distruptors. Sixty-five cosmetics were purchased from online and offline stores in Busan. This study developed a simultaneous method for the analysis of phthalates by GC-FID. The results showed that among the 65 cosmetics, DBP, DEHP, and DEP were detected at 20.0%, 7.7%, 1.5%, respectively. The amounts of DBP and DEHP detected in 18 samples were less than 100 μg/g, which satisfies the Regulations of Cosmetic Safety Standards in Korea. In order to detect phthalates in cosmetic containers, a dissolution test was conducted by extracting solutions, such as water, n-heptane, 20% ethanol, 50% ethanol and 4% acetic acid, which were prepared with different levels of pH, alcohol content, and fat content following the Korea Standards and Specifications for Utensils, Containers, and Packaging. The results showed that DMP, DBP, DEHA, BBP, DEHP, and DNOP were not detected, DEP was detected in plastics such as PE, PP, and others, when a 50% alcohol solvent was used. Phthalates may not be detected in cosmetic containers if they are not packaged with the above 20% alcohol constituent. We also analyzed the concentration of heavy metals, such as Pb, Cd, and Hg, by using ICP-OES and a mercury analyzer. The ranges of concentration were ND~2.71 μg/g for Pb, ND~0.31 μg/g for Cd, and ND~0.01 μg/g for Hg, which are below the regulated level.

Induction of Growth Inhibition by BCH in KB Human Oral Epidermoid Carcinoma Cells (구강 편평세포암종 KB세포에서 아미노산 수송억제제 BCH에 의한 세포성장 억제)

  • Yoon, Jung-Hoon;Kim, Youn-Bae;Kim, Do-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.5
    • /
    • pp.758-763
    • /
    • 2003
  • Amino acid transporters play an important role in supplying nutrients to normal and cancer cells for cell proliferation. System L is a major transport system responsible for the N $a^{+}$-independent, large neutral amino acids including several essential amino acids. L-type amino acid transporter 1 (LAT1), an isoform of system L amino acid transporter, is highly expressed presumably to support their continuous growth and proliferation in malignant tumors. 2-Aminobicyclo- (2,2,1) -heptane-2-carboxylic acid (BCH) is a model compound for study of amino acid transporter as a system L selective inhibitor. In the present study, we examined whether BCH induced growth inhibition in KB human oral squamous carcinoma cell line or not. The uptake of L-[$^{14}$ C]leucine by KB cells is inhibited by BCH in a concentration dependent manner with a Ι $C_{50}$ value of 75.3$\pm$6.2 ${\mu}{\textrm}{m}$ and a $K_{i}$ value of 98.7$\pm$ 4.1 ${\mu}{\textrm}{m}$. The growth of KB cells is inhibited by BCH in time dependent manner and concentration dependent manner with a Ι $C_{50}$ value of 11.1 $\pm$0.8 mM. In the DNA of KB cells treated with the various concentrations and various periods of BCH, the characteristic ladders associated with DNA fragmentation were not observed. These results suggest that BCH inhibits the growth of KB oral epidermoid carcinoma cells through the inhibition of transport of neutral amino acids into cells without DNA break down. This phenomenon will be a new rationale for anti-cancer therapy.y.

Effect of Differences between Korean Ministry of Environment Standard and ISO Standard on Determination of Petroleum Hydrocarbon Content in Soil (토양오염공정시험기준과 국제표준간의 분석방법 차이가 유류 정량에 미치는 영향)

  • Jung, In-Ho;Lee, Goon-Taek;Lee, Won-Seok;Kim, Yong-Hoon;Kim, Bo-Hyun;Kim, Ji-In;Kim, Bo-Kyong
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.63-72
    • /
    • 2012
  • The main objective of this study is to assess the compatibility between Korean ministry of environment (KME) standard and ISO (KS I ISO) standard for the determination of BTEX and TPH content in soil. We carried out comparison analysis for both methods using CRM and matrix spiked samples. In case of GC-MS analysis for BTEX, we got statistically (significance level: 0.05) the same results from KME standard (ES 07600.1) and ISO standard (KS I ISO 15009). However, it showed statistically (significance level: 0.05) different results when TPH was analyzed by KME standard (ES 07552.1) and ISO standard (KS I ISO 16703). To clarify the reason why both methods produced different results for TPH content, we also did some additional experiments in terms of differences in extraction, clean-up and target hydrocarbon range. Extraction with polar and non-polar compounds mixed solvent (acetone+n-heptane) of KS I ISO 16703 showed higher extraction efficiency than with only non polar solvent (dichloromethane) extraction of ES 07552.1 by about 9%. While column type clean-up of KS I ISO 16703 showed the reduction in TPH content between before and after clean-up, batch type of clean-up of ES 07552.1 did not show any changes in TPH content through clean-up process. The target hydrocarbon range of ES 07552.1 and KS I ISO 16703 is $C_8{\sim}C_{40}$ and $C_{10}{\sim}C_{40}$, respectively. From this point of view, kerosene and JP-8 contaminated soil showed higher RPD (relative producibility deviation) values between results by both method than that of lubricant or diesel contaminated soil. The higher content of hydrocarbon ($C_8{\sim}C_{10}$) in kerosene and JP-8 played an important role in increasing RPD values in addition to the effects caused by different solvents and clean-up method. Consequently, it was concluded that both methods (ES 07552.1 and KS I ISO 16703) were not compatible.

A Study on Migration of Ethylenediamine and Hexamethylenediamine from Polyamide Utensils (Polyamide 조리기구로부터 Ethylenediamine 및 Hexamethylenediamine의 이행에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Yoon, Hae-Jung;Jeon, Dae-Hoon;Choi, Hyun-Chul;Kim, Hyung-Il;Sung, Jun-Hyun;Park, Na-Young;Kim, So-Hee;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2010
  • The method for the determination of ethylenediamine (EDA) and hexamethylenediamine (HMDA) in food simulants was developed, and migration amounts of these compounds was monitored for 124 polyamide (PA) utensils. The diurethane derivatives of EDA and HMDA, which produced by reaction with ethyl chloroformate, were analyzed by using gas chromatograph (GC)/flame ionization detector (FID) and GC/mass spectrometer (MS). The developed method was validated with $0.3\;{\mu}g/mL$ of limit of detection (LOD) for EDA and $0.1\;{\mu}g/mL$ of LOD for HMDA, > 0.999 of linearity($r^2$) and > 88% of recovery. The EDA was detected 1.31 and $02.06\;{\mu}g/mL$ for 2 samples in water. The HMDA was detected $0.29\;-\;0.93\;{\mu}g/mL$ for 3 samples in 20% ethanol and $0.26\;-\;0.44\;{\mu}g/mL$ for 10 samples in n-heptane. These migration levels were below the specific migration limits (SML) of $12\;{\mu}g/mL$ and $2.4\;{\mu}g/mL$ for EDA and HMDA established in EU.

Effect of xylazine hydrochloride on histamine release (Xylazine이 histamine 유리에 미치는 영향)

  • 김영환;박준형
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.53-73
    • /
    • 2002
  • It has been reported that degranulation of mast cells in rats, rabbits and dog was observed after dosing xylazine hydrochloride(Xh) which has been widely used as sedative, analgesic and muscular relaxant. Therefore, this experiment was conducted to examine the relations between Xh and histamine release and to identify the action of ${\alpha}$-adrenoceptors which exists on the suface of mast cells. 1. The content of histamine within serum was measured with HPLC by performing the O-phthalaldehyde(OPA) fluorescent derivation. The pretreatment method had a little modification from the conventional method. The pretreament was carried out in the following method. 0.2$m\ell$ of serum and 1$m\ell$ of butanol were added to mixed together and then the liquid was centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 3 minutes. 0.4$m\ell$ of 0.1N HCl and 1.6$m\ell$ of heptane were added to 0.8$m\ell$ of supernatant taken from the liquid, and they were mixed together. This mixture was also centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 5 minutes. The supernatant was thrown away and the OPA fluorescent derivation was carried out with 0.2$m\ell$ of the lower liquid then, 5 minutes after mixing 400${\mu}\ell$ of 0.1N HCl, 120${\mu}\ell$ of 1N NaOH and 40${\mu}\ell$ of 0.1% OPA in the 0.2$m\ell$ of the lower liquid,120${\mu}\ell$ of 3.57N H$_3$PO$_4$ was added to the mixed liquid, and the liquid, was mixed again and syringe-filtered. Then, the measurement was done with HPLC in the 30 : 70(ν/ν) ratio of 0.004M KH$_2$PO$_4$: CH$_3$CN, flow rate of 1.0$m\ell$/min., and a wavelength of λex= 350nm and λem=444nm at the column temperature of 27$^{\circ}C$, using the fluorescence detector. 2. The content of histamine in each laboratory animal appeared to be higher in such an order as rabbit, rat, guinea pig, dog, Korean indigenous goat, swine, Korean indigenous cattle, Holstein, and mouse, of which the individual mean values${\pm}$standard deviation were 2.0668 ${\pm}$ 0.6049. 0.4999 ${\pm}$ 0.2278, 0.4241 ${\pm}$ 0.1974, 0.1054 ${\pm}$ 0.0556, 0.1028 ${\pm}$ 0.0276, 0.0972 ${\pm}$ 0.0513, 0.0872 ${\pm}$ 0.0373, 0.0717 ${\pm}$ 0.0379, and 0.0706 ${\pm}$ 0.0366, respectively. 3. The content of histamine was measured at the moments of 15-, 30-, 60-, 120-minutes after inoamuscular injection of 20mg/100kg Xh into two to 4 years old Holstein weighing 600∼700kg. The result showed that there was a significant increase at the times of 30- and 90-minutes after injection(p<0.05). 4. Intramuscular injection of 3mg/10kg Xh was given to crossbred pug dogs weighing 2.5∼4.3kg. The content of histamine was measured at the times of 30-, 60-, 90- and 120-minutes after injection. The result revealed that there was a significant increase at the times of 60-and 90-minutes after injection(p<0.05). 5. Intramuscular injection of 10mg/$m\ell$∼25mg/$m\ell$ Xh in concentration of 0.1$m\ell$ was applied to Korean indigenous goat over 5 months old. Then, the content of histamine was measured at the times of 15-, 30-, 60- and 90-minutes after injection. A significant increase was shown at the times of 30- and 60-minutes after injection(p<0.05). 6. The content of histamine was measured at the moments of 30- and 60-minutes after intramuscular injection of 0.1-0.2$m\ell$ Xh (20mg/$m\ell$) into male rabbits weighting 2.5-4kg. A significant increase was found at the moment of 60 minutes after injection(p<0.001). 7. After administering Xh to the mast cell taken from the abdominal cavity of mouse, the content of histamine was measured. The result showed that the higher the concentration, the more significantly the content of histamine was increased(p<0.05). 8. Compound 48/80 was administered in concentration of 5$\mu\textrm{g}$/$m\ell$ and 10$\mu\textrm{g}$/$m\ell$ to the mast cell picked from the abdominal cavity of mouse. The result showed that there was a significant increase in the content of histamine in case of the concentration of 10$\mu\textrm{g}$/$m\ell$(p<0.05). It was found to be about 10,000 to 500,000 times stronger than the Xh. 9. After premedication of 1mg/kg of yohimbine hydrochloride as ${\alpha}$$_2$-adrenergic antagonist to rabbits, the Xh was administered to them. The result was that the value of histamine within serum was decreased significantly(p<0.001). 10. After premeditation of 1mg/kg of prazosin hydrochloride as ${\alpha}$$_1$-adrenergic antagonist to rabbits, the Xh was administered to them. It was found that the value of histamine within serum was decreased significantly(p<0.005). 11, Prazosin hydrochloride and yohimbine hydrochloride as ${\alpha}$$_1$-adrenergic antagonist, respectively, and ${\alpha}$$_2$-adrenergic antagonist were administerd. In this case, the value of histamine within serum was decreased significantly(p<0.0001). As the results, when the Xh is administered to various kinds of animals, the amount of histamine release within serum is increased. In view of the results so far achieved, it is concluded that Xh acted on both a$_1$-adrenoreceptor and ${\alpha}$$_2$-adrenoreceptor induces the degranulation of mast cell.

Development and Validation of Analytical Method for Determination of Biphenyl Analysis in Foods (식품 중 비페닐 분석법 개발 및 유효성 검증)

  • Kim, Jung-Bok;Kim, Myung-Chul;Song, Sung-Woan;Shin, Jae-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.4
    • /
    • pp.459-464
    • /
    • 2017
  • Biphenyl is used as an intermediate in the production of crop protection products, a solvent in pharmaceutical production, and as a component in the preservation of citrus fruits in many countries. Biphenyl is not authorized for use and also does not have standards or specifications as a food additive in Korea. National and imported food products are likely to contain biphenyl. Therefore, control and management of these products is required. In this study, a simple analytical method was developed and validated using HPLC to determine biphenyl in food. These methods are validated by assessing certain performance parameters: linearity, accuracy, precision, recovery, limit of detection (LOD), and limit of quantitation (LOQ). The calibration curve was obtained from 1.0 to $100.0{\mu}g/mL$ with satisfactory relative standard deviations (RSD) of 0.999 in the representative sample (orange). In the measurement of quality control (QC) samples, accuracy was in the range of 95.8~104.0% within normal values. The inter-day and inter-day precision values were less than 2.4% RSD in the measurement of QC samples. Recoveries of biphenyl from spiked orange samples ranged from 92.7 to 99.4% with RSD between 0.7 and 1.7% at levels of 10, 50, and $100{\mu}g/mL$. The LOD and LOQ were determined to be 0.04 and $0.13{\mu}g/mL$, respectively. These results show that the developed method is appropriate for biphenyl identification and can be used to examine the safety of citrus fruits and surface treatments containing biphenyl residues.