• 제목/요약/키워드: N-chlorination

검색결과 40건 처리시간 0.019초

암모니아성질소를 함유한 금강중류 하천수의 오존-활성탄처리 (Ozone-Activated Carbon Treatment in Middle Keum River containing Ammonia-Nitrogen)

  • 김충환;정상기;김학성
    • 한국물환경학회지
    • /
    • 제18권4호
    • /
    • pp.355-363
    • /
    • 2002
  • A demonstration plant was carried out to investigate the removal efficiency of $NH_3-N$ and $KMnO_4$ consumption depending on the existence of pre-chlorination for the ozonation and activated carbon process in the S water treatment plant which is located at the middle of Keum River. The averge removal efficiency of $KMnO_4$ consumption for $O_3/GAC$ processes with pre-chlorination and $O_3/BAC$ processes without pre-chlorination were 48.6% and 50% respectively. It is similar to removal effect of $KMnO_4$ consumption for GAC and BAC process depending on the existence of pre-chlorination. Otherwise, the removal of THMFP for GAC and BAC process was 58% and 68% respectively. $NH_3-N$ was not almost removed by sand filter and ozonation, but the average removal efficiency in the BAC process was about 31%. Especially, $NH_3-N$ was not almost removed by $O_3/BAC$ processes at the low temperature (below $$10^{\circ}C$$) in the winter season, $O_3/BAC$ processes have the advantage of removal of organic substance when it is compared to pre -chlorination followed by $O_3/GAC$ processes. Pre-chlorination followed by $O_3/GAC$ processes were required to remove $NH_3-N$ in the winter season because the removal of $NH_3-N$ was almost ineffective by $O_3/BAC$ process.

Poly(N,N'-Dichloro-N-ethyl-benzene-1,3-disulfonamide) and N,N,N',N'-Tetrachlorobenzene-1,3-disulfonamide as Efficient Reagents to Direct Oxidative Conversion of Thiols and Disulfide to Sulfonyl Chlorides

  • Veisi, Hojat;Ghorbani-Vaghei, Ramin;Mahmoodi, Jafar
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권10호
    • /
    • pp.3692-3695
    • /
    • 2011
  • Poly(N,N'-Dichloro-N-ethyl-benzene-1,3-disulfonamide) (PCBS) and N,N,N',N'-Tetrachlorobenzene-1,3-disulfonamide (TCBDA) were found to be a mild and efficient reagent for the direct oxidative conversion of sulfur compounds to the corresponding arenesulfonyl chlorides in good to excellent yields through the oxidative chlorination. The overall process is simple, practical, and it provides convenient access to a variety of aryl or heteroarylsulfonyl chlorides. The mild reaction conditions and the broad substrate scope render this method attractive, and complementary to existing syntheses of aryl or heteroarylsulfonyl chlorides.

여러 종류의 할로겐 화합물과 고분자량 파라핀계 탄화수소의 염소화에서 생기는 이성질화에 관한 연구 (Isomer Formation in the Chlorination of Highmolecular Paraffinic Hydrocarbons by Various Halogenating Agents)

  • 궁이환
    • 대한화학회지
    • /
    • 제32권4호
    • /
    • pp.390-405
    • /
    • 1988
  • n-Heptane, n-Octane, n-Decane, 2,3-Dimethyl Butane을 chlorination agent인 N-chlorosuccinimide, tert-Butylhypochloride, Trichloromethanesulfonylchloride, Carbontetrachloride, Trichloromethanesulfenyl chloride, Phosphorous pentachloride Chlorine등으로 benzene 또는 $CS_2$ 용매중에서 염소화시킬때 생기는 Mono-chloro alkane의 이성질화 혼합물을 정량적으로 고찰하였다. 여기에서 파라핀계 탄화수소의 치환비율에 대한 지금까지 알려진 사실과 일치하지 않는 놀라운 이성질화 분포(Isomerization distribution)를 확립하였다. 이러한 결과는 극성효과를 갖는 공격하는 라디칼의 free energy, 그리고 alkane의 개개의 수소 원자가 지니는 여러가지 서로다른 C-H bond 해리에너지의 상호작용을 통하여 얻어졌다.

  • PDF

SiC의 염소화에 의한 다공성 탄소 입자 제조 (Preparation of Porous Carbon by Chlorination of SiC)

  • 박회경;박균영;강태원;장희동
    • 한국입자에어로졸학회지
    • /
    • 제8권4호
    • /
    • pp.173-180
    • /
    • 2012
  • SiC particles, 8.3 ${\mu}m$ in volume average diameter, were chlorinated in an alumina tubular reactor, 2.4 cm in diameter and 32 cm in length, with reactor temperature varied from 100 to $1200^{\circ}C$. The flow rate of the gas admitted to the reactor was held constant at 300 cc/min, the mole fraction of chlorine in the gas at 0.1 and the reaction time at 4 h. The chlorination was negligibly small up to the temperature of $500^{\circ}C$. Thereafter, the degree of chlorination increased remarkably with increasing temperature until $900^{\circ}C$. As the temperature was increased further from 900 to $1200^{\circ}C$, the increments in chlorination degree were rather small. At $1200^{\circ}C$, the chlorination has nearly been completed. The surface area of the residual carbon varied with chlorination temperature in a manner similar to that with the variation of chlorination degree with temperature. The surface area at $1200^{\circ}C$ was 912 $m^{2}/g$. A simple model was developed to predict the conversion of a SiC under various conditions. A Langmuir-Hinshelwood type rate law with two rate constants was employed in the model. Assuming that the two rate constants, $k_{1}$ and $k_{2}$, can be expressed as $A_{1e}^{-E_{1}/RT}$ and $A_{2e}^{-E_{2}/RT}$, the four parameters, $A_{1}$, $E_{1}$, $A_{2}$, and $E_{2}$ were determined to be 32.0 m/min, 103,071 J/mol, 2.24 $m^{3}/mol$ and 39,526 J/mol, respectively, through regression to best fit experimental data.

하수의 염소 소독시 총잔류염소 감소 특성에 관한 연구 (Studies on Chlorine Demand and Its Decay Kinetics in Chlorinated Sewage Effluents)

  • 백영석;손진식
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.176-183
    • /
    • 2005
  • Chlorination of wastewater is recently practiced in Korea. While many researchers have studied the kinetics of aqueous chlorine(HOCl) with nitrogeneous compounds and other organic/inorganic contaminants in drinking water, the researches of wastewater chlorination are relatively few. The purpose of this study was to investigate the chlorine decay kinetics and parameters on wastewater chlorination. Chlorine decay rate increased with increasing initial chlorine concentration. The parameters affecting chlorine decay rate were different in each wastewater treatment plant. One of the most important parameters affecting chlorine decay was initial chlorine concentration, and other parameters such as $NH_3-N$, total coliform, $UV_{254}$ and Fe were also affected. The decay ratio of chlorine was decreased with increasing initial chlorine concentration, and the disinfection efficiency showed good correlation with the decay ratio.

Hypochlorite treatment of polyamide membrane for improved reverse osmosis performance

  • Shao, P.;Kurth, C.J.
    • Membrane and Water Treatment
    • /
    • 제4권1호
    • /
    • pp.69-81
    • /
    • 2013
  • The pH-dependent inter-conversion of the three free chlorine species ($Cl_2$, HOCl, OCl-) present in the aqueous hypochlorite solution was theoretically investigated. Each species was found overwhelmingly present in a characteristic pH range. Hypochlorite treatment of the polyamide membrane was carried out over these pH ranges and various membrane responses were observed. As pH is less than 8, membrane tends to be N-chlorinated by $Cl_2$ and HOCl, and N-chlorinated membrane showed reduced water permeance and salt rejection. As pH rises to 10-12, $OCl^-$ appears to be the dominating chlorine species. Membrane hydrolysis was found to well interpret the improved water permeance and salt rejection. When the pH is between 8-10, both N-chlorination and hydrolysis contribute to the response of the membrane, and the treated membrane showed improved salt rejection but reduced water permeation. Excessive hydrolysis occurred while the membrane was treated at pH 13 for the much stronger alkalinity.

Homologue Patterns of Polychlorinated Naphthalenes (PCNs) formed via Chlorination in Thermal Process

  • Ryu, Jae-Yong;Kim, Do-Hyong;Mulholland, James A.;Jang, Seong-Ho;Choi, Chang-Yong;Kim, Jong-Bum
    • 한국환경과학회지
    • /
    • 제21권8호
    • /
    • pp.891-899
    • /
    • 2012
  • The chlorination pattern of naphthalene vapor when passed through a 1 cm particle bed of 0.5% (mass) copper (II) chloride ($CuCl_2$) mixed with silicon dioxide ($SiO_2$) was studied. Gas streams consisting of 92% (molar) $N_2$, 8% $O_2$ and 0.1% naphthalene vapor were introduced to an isothermal flow reactor containing the $CuCl_2/SiO_2$ particle bed. Chlorination of naphthalene was studied from 100 to $400^{\circ}C$ at a gas velocity of 2.7 cm/s. Mono through hexachlorinated naphthalene congeners were observed at $250^{\circ}C$ whereas a broader distribution of polychlorinated naphthalenes (PCNs) including hepta and octachlorinated naphthalenes was observed at $300^{\circ}C$. PCN production was peak at $250^{\circ}C$ with 3.07% (molar) yield, and monochloronaphthalene (MCN) congeners were the major products at two different temperatures. In order to assess the effect of a residence time on naphthalene chlorination, an experiment was also conducted at $300^{\circ}C$ with a gas velocity of 0.32 cm/s. The degree of naphthalene chlorination increased as a gas velocity decreased.

산화환원전위제어법에 의한 수도원수의 불연결점 염소처리 (Redox control in break-point chlorination of ammonia)

  • 하성룡;제등방정
    • 물과 미래
    • /
    • 제23권3호
    • /
    • pp.363-371
    • /
    • 1990
  • 본연구는 정수처리에 있어서의 적정염소주입제어를 위한 산화환원전위법의 활용가능성에 대한 기초적 검토를 실시한 것이다. 연구실험을 통하여, 원수의 염소화반응에 미치는 pH와 온도 및 산화환원전위의 재현성에 대하여 평가하였다. 수도원수의 불연속점부근에 있어서의 산화환원전위의 검출은 불연속점적정곡선의 작성에 의하여 이루어졌으며, 이로 인하여 본방법의 염소처리제어에의 기본적인 활용가능성이 확인되었다.

  • PDF

농촌지역의 효율적인 간이 상수처리에 관한 연구 (A Study on Efficient Simple Water Supply System in Rural Areas)

  • 이홍근;백남원;백도현
    • 한국환경보건학회지
    • /
    • 제22권3호
    • /
    • pp.103-115
    • /
    • 1996
  • The purpose of this study was to establish acceptable criteria for the design of simple water treatment plant in rural areas. To develop efficient simple water treatment methods for rural areas, water quality in the study areas was investigated and rapid and slow filtrations in pilot-scale were tested under various conditions. The main results of this study are as follows. It was found that the water qualities of the study areas exceed the drinking water standards, which implies that some treatments are required in rural areas. Treatment efficiencies of both rapid sand and dual-media (sand and anthracite) filtration without pre-treatment such as flocculation and sedimentation are very low, which were turned out to be unadequate for the rural areas. Treatment efficiencies of both vertical and horizontal slow filtration without chlorination are very high for consumed $KMnO_4, NH_3-N, NO_3-N$, turbidity, and very low for coliform and bacteria. Treatment efficiencies of both vertical and horizontal slow filtration with chlorination are very high over the most pollutants. A slow filtration with chlorination is efficient for the rural areas. An adequate depth of sand layer is over 60 cm. A horizontal filtration is more economical than a vertical filtration. A horizontal filtration can be operated for a relatively long periods of time without sand washing or replacement because clogging is removed by simple back-washing.

  • PDF