• Title/Summary/Keyword: N-Sided Face

Search Result 2, Processing Time 0.015 seconds

A STUDY OF SUBDIVISION METHOD TO THREE AND FIVE SIDED FACES BASED ON REGULAR POLYGON

  • Muraki, Yuta;Konno, Kouichi;Tokuyama, Yoshimasa
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.551-556
    • /
    • 2009
  • 3-D CAD (Computer Aided Design) system is an indispensable tool for manufacturing. A lot of engineers have studied for the methods to generate a curved surface on an N-sided shape, which is the basic technology of 3-D CAD systems. This surface generation, however, has three problems on the case of long and narrow shapes: the resultant surface is distorted, the surface is not continuous to adjacent surfaces, or additional user inputs are required to generate the surface. Conventional methods have not yet solved these problems at the same time. In this paper, we propose the method to generate internal curves that divide a long and narrow shape into regular N-sided sections so as to divide the shape into an N-sided section and four-sided ones. Our method controls the shape of internal curves by dividing an N-sided long and narrow shape into an N-sided section and four-sided ones, and solves distortion of the generated curved surface. In addition, each of the generated sections is interpolated with G1-continuous surfaces. This process does not require any user's further input. Therefore, the three problems mentioned above will be solved at the same time.

  • PDF

Sampling Efficiency of Organic Vapor Passive Samplers by Diffusive Length (확산길이에 따른 수동식 유기용제 시료채취기의 시료채취성능에 관한 연구)

  • Lee, Byung-Kyu;Jang, Jae-Kil;Jeong, Jee-Yeon
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.6
    • /
    • pp.500-509
    • /
    • 2009
  • Passive samplers have been used for many years for the sampling of organic vapors in work environment atmospheres. Currently, all passive samplers used in domestic occupational monitoring are foreign products. This study was performed to evaluate variable parameters for the development of passive organic samplers, which include the geometry of the device and diffusive length for the sampler design. Four prototype diffusive lengths; A-1(4.5 mm), A-2(7.0 mm), A-3(9.5 mm), A-4(12.0 mm) were tested for adsorption performances to a chemical mixture (benzene, toluene, trichloroethylene, and n-hexane) according to the US-OSHA's evaluation protocol. A dynamic vapor exposure chamber developed and verified by related research was used for this study. The results of study are as follows. The results in terms of sampling rate and recommended sampling time test indicate that the most suitable model was A-3 (9.5 mm diffusive lengths on both sides) for passive sampler design in time weighted average (TWA) assessment. Sampling rates of this A-3 model were 45.8, 41.5, 41.4, and 40.3 ml/min for benzene, toluene, trichloroethylene, and n-hexane, respectively. The A-3 models were tested on reverse diffusion and conditions of low humidity air (35% RH) and low concentrations (0.2 times of TLV). These conditions had no affect on the diffusion capacity of samplers. In conclusion, the most suitable design parameters of passive sampler are: 1) Geometry and structure - 25 mm diameter and 490 $mm^2$ cross sectional area of diffusion face with cylindrical form of two-sided opposite diffusion direction; 2) Diffusive length - 9.5 mm in both faces; 3) Amount of adsorbent - 300 mg of coconut shell charcoal; 4) Wind screen - using nylon net filters (11 ${\mu}m$ pore size).