• Title/Summary/Keyword: N immobilization

Search Result 161, Processing Time 0.03 seconds

Immobilization of Layered Double Hydroxide into Polyvinyl Alcohol/Alginate Hydrogel Beads for Phosphate Removal

  • Han, Yong-Un;Lee, Chang-Gu;Park, Jeong-Ann;Kang, Jin-Kyu;Lee, In;Kim, Song-Bae
    • Environmental Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.133-138
    • /
    • 2012
  • Polyvinyl alcohol/alginate hydrogel beads containing Mg-Al layered double hydroxide (LDH-PVA/alginate beads) were synthesized for phosphate removal. Results showed that blending PVA with the LDH-alginate beads significantly improved their stability in a phosphate solution. The kinetic reaction in LDH-PVA/alginate beads reached equilibrium at 12 hr-post reaction with 99.2% removal. The amount of phosphate removed at equilibrium ($q_e$) was determined to be 0.389 mgP/g. The equilibrium data were described well by the Freundlich isotherm with the distribution coefficient ($K_F$, 0.638) and the constant (n, 0.396). Phosphate removal in LDH-PVA/alginate beads was not sensitive to solution pH. Also, the removal capacity of LDH-PVA/alginate beads ($q_e$, 1.543 mgP/g) was two orders of magnitude greater than that of PVA/alginate beads ($q_e$, 0.016 mgP/g) in column experiments. This study demonstrates that LDH-PVA/alginate beads with a higher chemical stability against phosphate compared to LDH-alginate beads have the potential for phosphate removal as adsorptive media.

Amperometric Biosensor for Hydrogen Peroxide Determination Based on Black Goat Liver-Tissue and Ferrocene Mediation (흑염소 간-조직과 Ferrocene 매개체를 사용한 과산화수소정량 전류법 바이오센서)

  • Kwon, Hyo-Shik;Park, In-Keun;Kim, Yang-Sug
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.5
    • /
    • pp.491-498
    • /
    • 2004
  • The response characteristics of the bioelectrode developed by the co-immobilization of black goat liver tissue and ferrocene in a carbon paste matrix for the amperometric determination of hydrogen peroxide were evaluated. In the range of electrode potential examined ($-0.3{\sim}+0.0\;V$ vs. Ag/AgCl), the response time was relatively short (t95%=12 s) and it responded in the wide range of pH. The detection limit was 2.25${\times)10^{-6}M$ and a relative standard deviation of the measurements which were repeated 15 times using 1.0${\times}10^{-2 }$M hydrogen peroxide was 1.87%. The bioelectrode sensitivity decreased to 50% of the original value in 19 days of continuous use.

Electrochemical Detection of Hydrogen Peroxide based on Hemoglobin-DNA/pyterpy Modified Gold Electrode (Hemoglobin-DNA/pyterpy 박막을 이용한 과산화수소의 전기화학적 검출)

  • Lee, Dong-Yun;Choi, Won-Suk;Park, Sang-Hyun;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1295-1296
    • /
    • 2008
  • Hydrogen peroxide ($H_2O_2$) biosensor is one of the most developing sensors because this kind of sensors is highly selective and responds quickly to the specific substrate. Hemoglobin (Hb) has been used as ideal biomolecules to construct hydrogen peroxide biosensors because of their high selectivity to $H_2O_2$. The direct electron transfer of Hb has widely investigated for application in the determination of $H_2O_2$ because of its simplicity, high selectivity and intrinsic sensitivity. An electrochemical detection for hydrogen peroxide was investigated based on immobilization of hemoglobin on DNA/Fe(pyterpy)$^{2+}$ modified gold electrode. The pyterpy monolayers were firstly an electron deposition onto the gold electrode surface of the quartz crystal microbalance (QCM). It is offered a template to attach negatively charged DNA. The fabrication process of the electrode was verified by quartz crystal analyzer (QCA). The experimental parameters such as pH, applied potential and amperometric response were evaluated and optimized. Under the optimized conditions, this sensor shows the linear response within the range between $3.0{\times}10^{-6}$ to $9.0{|times}10^{-4}$ M concentrations of $H_2O_2$. The detection limit was determined to be $9{\times}10^{-7}$ M (based on the S/N=3).

  • PDF

Fabrication and Sensing Capability of Cholesterol Sensors Based on ZnO Nanofibers (산화아연 나노섬유 기반 콜레스테롤 센서의 제작과 성능)

  • Jo, So Yeon;Kim, Ji Yeong;Kim, Sang Sub
    • Korean Journal of Materials Research
    • /
    • v.23 no.5
    • /
    • pp.281-285
    • /
    • 2013
  • In the present work, ZnO nanofibers were applied to electrode materials for the detection of cholesterol. ZnO nanofibers were synthesized using the electrospinning technique with zinc acetate as a precursor. Electrospinning-synthesized ZnO nanofibers were uniformly distributed by properly controlling the electrospinning parameters. After the calcination treatment, nanofibers of pure ZnO phase were synthesized. Then, these fibers were successfully placed on Au-coated glass substrates by dispersion of ZnO nanofibers in ethanol, dropping, and drying, in sequence. Cholesterol oxidase was then immobilized onto the surface of the ZnO nanofibers. To enhance the immobilization, Nafion was additionally applied. The sensing performances of the fabricated ZnO nanofibers-based sensors were analyzed by cyclic voltammetry in terms of cholesterol concentration ranging from 100 to 400 mg/dl. In the I-V curves, measured by cyclic voltammetry, the ZnO nanofiber-based sensor showed a proportional current behavior with cholesterol concentrations in phosphate buffered saline solution. The sensitivity was measured and found to be $30.7nA/mM{\cdot}cm^2$, which is comparable to the values reported in the literature. After not only optimizing the shape of the ZnO nanofibers but also improving the adhesion nature between the ZnO nanofibers and the Au conducting layer, these fibers can be a good candidate for electrode materials in devices used to detect low concentrations of cholesterol in blood.

Preparation of Enzyme Electrodes for Biofuel Cells Based on the Immobilization of Glucose Oxidase in Polyion Complex (폴리이온복합체를 이용하여 글루코스 산화효소를 고정화한 바이오전지용 효소전극 제조)

  • Nguyen, Linh Thi My;Li, Nan;Yoon, Hyon Hee
    • Applied Chemistry for Engineering
    • /
    • v.24 no.1
    • /
    • pp.99-103
    • /
    • 2013
  • An emzymatic bioanode for a glucose/oxygen biofuel cell was prepared by the sequential coating of carbon nanotube (CNT), charge transfer complex (CTC) based on tetracyanoquinodimethane (TCNQ) and tetrathiafulvalene (TTF), glucose oxidase (GOx), and polyion complex (mixture of poly-L-lysine hydrobromide and poly (sodium 4-styrenesulfonate)) on a glassy carbon electrode. A biocathode was also prepared by the sequential coating of CNT, bilirubin oxidase (BOD), 2,2'-Azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS), and polyion complex. The effect of CNT and CTC on the electrochemical performance was investigated. The biofuel cell exhibited a promising performance with maximum power densities of 3.6, 10.1, and $46.5{\mu}W/cm^2$ at 5, 20, and 200 mM of glucose concentration, respectively. The result indicates that the biofuel cell architecture prepared in this study can be used in the development of biofuel cells and biosensors.

Quantitative Assay of Recombinant Hepatitis B Surface Antigen by Using Surface Plasmon Resonance Biosensor (Surface plasmon resonance 바이오센서를 이용한 재조합 B형 간염 표면항원의 정량분석)

  • Lee, E. K.;Ahn, S. J.;Yoo, C. H.;Ryu, K.;Jeon, J. Y.;Lee, H. I.;Choi, S. C.;Lee, Y. S.
    • KSBB Journal
    • /
    • v.17 no.1
    • /
    • pp.20-25
    • /
    • 2002
  • We performed a basic experiment for rapid, on-line, real-time measurement of HBsAg by using a surface plasmon resonance biosensor to quantify the recognition and interaction of biomolecules. We immobilized the anti-HBsAg polyclonal antibody to the dextran layer on a CM5 chip surface which was pre-activated by N-hydroxysuccinimide for amine coupling. The binding of the HBsAg to the immobilized antibody was measured by the mass increase detected by the change in the SPR signal. The binding characteristics between HBsAg and its antibody followed typical monolayer adsorption isotherm. When the entire immobilized antibody was interacted, there was no additional, non-specific binding observed, which suggested the biointeraction was very specific as expected and independent of the ligand density. No significant steric hindrance was observed at 17.6 nm/$mm^2$ immobilization density. The relationship between the HBsAg concentration in the sample solution and the antigen bound to the chip surface was linear up to ca. $40\mu\textrm{g}$/mL, which is much wider than that of the ELISA method. It appeared the antigen-antibody binding was increased as the immobilized ligand density increased, but verification is warranted. This study showed the potential of this biosensor-based method as a rapid, simple, multi-sample, on-line assay. Once properly validated, it can serve as a more powerful method for HBsAg quantification replacing the current ELISA method.

Degradation of Cyanide by Activated Sludge Immobilized with Polyethylene Glycol (고정화 활성슬러지를 이용한 시안 분해)

  • Cheong, Kyung-Hoon;Choi, Hyung-Il;Kim, Jung-Ae;Moon, Ok-Ran;Kim, Myung-Hee
    • Journal of Environmental Science International
    • /
    • v.17 no.12
    • /
    • pp.1343-1351
    • /
    • 2008
  • The activated sludge obtained from wastewater coke oven plant was immobilized by entrapment with polyethylene glycol (PEG). The effects of several factors on the biodegradation of $CN^-$ from. synthetic wastewater were investigated using batch and continuous reactors. The degradation rate of $CN^-$ increased with increasing of the immobilized bead volume in the reactor. Approximately 7.65mg/L of $NH_4-N$ was produced upon the degradation of 35mg/L of $CN^-$. When high concentrations of the toxic cyanide complex were used in the testing of cyanide degradation, the free activated sludge could be inhibited more than that of the immobilized activated sludge. When the phenol concentration was higher than 400mg/L in the synthetic wastewater, approximately 98.4% of $CN^-$ was removed within 42 hours by the immobilized activated sludge. However, the cyanide was not completely degraded by the tree activated sludge. This indicates that high phenol concentrations can act as a toxic factor for the free activated sludge. A $CN^-$ concentration of less than 1mg/L was achieved by the immobilized sludge at the loading rate of 0.025kg $CN^-/m^3-d$. Moreover, it was found that the HRT should be kept for 48 hours in order to obtain stable treatment conditions.

A novel method with photochemical reaction for LK immobilization on the polyurethane surface (폴리우레탄 표면의 광화학적 공유결합을 이용한 새로운 LK 고정화 방법에 관한 연구)

  • Kim, H.J.;Nakayama, Yasuhide;Shim, J.H.;Ryu, G.H.;Kim, J.;Matsuda, Takehisa;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.91-96
    • /
    • 1996
  • 광반응을 이용하여 fibrinolytic 활성을 보이는 LK (lumbrokinase)를 생체재료인 PU (polyurethane) 표면에 고정화하는 방법에 관하여 연구하였다. 먼저 PU표면에 amino 작용기를 도입하기 위하여 side chain 작용기로 phenylazide 와 amino작용기를 갖는 AzPhPAL을 이용하였으며 광반응은 266nm 이상의 UV light을 약 1분간 조사시키는 방법을 이용하였다. LK를 amino작용기가 유도된 PU 표면에 공유결합시키기 위하여 amide결합 형성시 사용되는 수용성 carbodiimide인 EDC를 이용하였다. ESCA측정시, AzPhPAL으로 공유결합시킨 경우 반응하지 않은 PU표면에 비하여 N/C가 0.1717로, LK 고정시 S/C가 0.0043로 증가된것을 알 수 있었다. 이것으로부터 AzPhPAL과 LK가 PU표면에 공유결합된 것을 확인할 수 있었으며 static contact angle 측정으로 표면개질된 PU표면이 소수성에서 친수성으로 변화된 것을 확인 할 수 있었다. 또한 공유결합된 LK의 활성을 확인하기 위하여 fibrin plate test를 실시하였는데 그 결과 고정화된 후에도 LK의 활성이 존재함을 알 수 있었다.

  • PDF

A Biomechanical Comparison of Intralaminar C7 Screw Constructs with and without Offset Connector Used for C6-7 Cervical Spine Immobilization : A Finite Element Study

  • Qasim, Muhammad;Hong, Jae Taek;Natarajan, Raghu N.;An, Howard S.
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.331-336
    • /
    • 2013
  • Objective : The offset connector can allow medial and lateral variability and facilitate intralaminar screw incorporation into the construct. The aim of this study was to compare the biomechanical characteristics of C7 intralaminar screw constructs with and without offset connector using a three dimensional finite element model of a C6-7 cervical spine segment. Methods : Finite element models representing C7 intralaminar screw constructs with and without the offset connector were developed. Range of motion (ROM) and maximum von Mises stresses in the vertebra for the two techniques were compared under pure moments in flexion, extension, lateral bending and axial rotation. Results : ROM for intralaminar screw construct with offset connector was less than the construct without the offset connector in the three principal directions. The maximum von Misses stress was observed in the C7 vertebra around the pedicle in both constructs. Maximum von Mises stress in the construct without offset connector was found to be 12-30% higher than the corresponding stresses in the construct with offset connector in the three principal directions. Conclusion : This study demonstrated that the intralaminar screw fixation with offset connector is better than the construct without offset connector in terms of biomechanical stability. Construct with the offset connector reduces the ROM of C6-7 segment more significantly compared to the construct without the offset connector and causes lower stresses around the C7 pedicle-vertebral body complex.

Polysomnographic Characteristics and Prescription Status of Restless Legs Syndrome Patients in Naturalistic Setting (임상현장에서 하지불안증후군 환자의 수면다원검사결과의 특징과 약물처방현황)

  • Kang, Seung-Gul;Nam, Ji-Hye;Kim, Hana;Shin, Hong Beom
    • Sleep Medicine and Psychophysiology
    • /
    • v.20 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • Objectives: The aim of this study is to evaluate the polysomnographic characteristics and prescription status of restless legs syndrome (RLS) patients in naturalistic setting. Methods: We reviewed medical record of the patients over 18 years olds who (i) satisfied the clinical RLS diagnostic criteria and (ii) had the polysomnography and got treatment related thereto. As a baseline, we evaluated the four diagnostic criteria of the International Restless Legs Syndrome Study Group (IRLSSG) and the International Restless Legs Scale (IRLS) of the subjects. Then the polysomnography and the suggested immobilization test (SIT) were conducted and, after one month of pharmacotherapy using dopamine agonist, the IRLS was evaluated again. Results: A total of 211 subjects participated in this analysis and 94 (44.5%) of them were male and the other 117 (55.5%) were female and the average age of the 211 subjects was $46.9{\pm}14.2$. Out of such 211 subjects, 136 subjects (64.5%) also had the obstructive sleep apnea (OSA), and 53 subjects (25.1%) also had the periodic limb movement disorder (PLMD). 185 subjects (87.7%) out of the 211 subjects had some other sleep disorders except RLS. The results of the polysomnography were as follows : 78.0% of sleep efficiency, 86.8 min of wake after sleep onset, and 3.4% of N3. More specifically, 12.4/h of the average apnea hypopnea index, 14.8/h of the periodic limb movement during sleep (PLMS), 41.2/h of the periodic limb movement during wake during SIT and 21.6/h of total arousal index during sleep. Out of the total subjects, 149 (70.6%) of them took the ropinirole and 47 (22.3%) of them took the pramipexole, and the average dosage of ropinirole was 0.9mg(dosage range 0.125-5 mg) while the average dosage of pramipexole was 0.5 mg (dosage range 0.125-4 mg). The dosage of the ropinirole showed a significant positive correlation with the age (r=0.25, p=0.002) and also with the IRLS (r=0.23, p=0.038). The IRLS at the baseline was 24.9 while the same was decreased down to 13.4 after one month. Conclusions: Analyzing the result of this study, a majority of clinical RLS subjects demonstrated comorbidity with some other sleep disorder such as the OSA or PLMD. 25.1% of the subjects showed a PLMD, which was less than in previous researches and the average PLMS was not very high as 14.8/h. The dosage of dopamine agonist taken was often a bit more than the amount recommended in Korea. A prospective research using a large scale controlled subjects will be necessary with respect to this topic.