• Title/Summary/Keyword: N Stainless Steel

Search Result 529, Processing Time 0.03 seconds

EFFECT OF MULTILAYER COATING ON THE CORROSION RESISTANCE OF SINTERED STAINLESS STEELS

  • Choe, Han-Cheol;Ko, Yeong-Mu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.136-137
    • /
    • 2003
  • In this study, in order to fabricate sintered dental implant, the effects of HA, Ti and TiN on corrosion and biocompatibility, cell toxicity, osseointegration of electroless Cu-plated and sintered stainless steel implant were investigated using various characteristics. The effects of Ti/TiN/HA coating on the interface activation and surface characteristics of sintered stainless steels(SSS) by electron-beam physical vapor deposition(EB-PVD) method have been studied. Stainless steel compacts containing 2, 4, and 10 wt%Cu were prepared by electroless Cu-plating method which results in the increased homogenization in alloying powder. The specimens were coated with HA, Ti and TiN with few $\mu\textrm{m}$ thickness respectively by EB-PVD method. The microstructures and phase analysis were conducted by using SEM. Biocompatibility were investigated in experimental dog. The corrosion behaviors were investigated using potentiosat in 0.9% NaCl solution and corrosion surface was observed using SEM and XPS.

  • PDF

Microstructure and High Temperature Deformation Behavior of Heat Resistant Stainless Steel for a Retort (열환원반응관용 내열강의 미세조직과 고온변형거동)

  • Choi, G.S.;Ha, T.K.
    • Transactions of Materials Processing
    • /
    • v.22 no.3
    • /
    • pp.165-170
    • /
    • 2013
  • High temperature deformation behavior of a heat-resistant duplex stainless steel, used as a retort in the Pidgeon process for Mg production, was investigated in this study. 25Cr-8Ni based duplex stainless steels were cast into rectangular ingots, with dimensions of $350mm{\times}350mm{\times}100mm$. Nitrogen and yttrium were added at 0.3wt.% each to enhance the heat-resistance of the steel. Phase equilibrium was calculated using the thermodynamic software FactSage$^{(R)}$ and the database of FSStel. For comparison, cast 310S steel, a widely used heat-resistant austenitic stainless steel, was also examined in this study. Dilatometry was conducted on the as-cast ingots for the temperature range from RT to $1200^{\circ}C$ and the thermal expansion coefficients were evaluated. The nitrogen addition was found to have an effect on the thermal expansion behavior for temperatures between 800 and $1000^{\circ}C$. High temperature tensile and compression tests were conducted on the ingots for temperatures ranging from 900 to $1230^{\circ}C$, which is the operation temperature employed in Mg production by the Silico-thermic reduction process. The steel containing both N and Y showed much higher strength as compared to 310S.

Improvement of Corrosion Resistance of 316L Stainless Steel by Gas Nitriding (가스 질화를 통한 316L스테인리스강의 내식성 개선)

  • Hyunbin Jo;Serim Park;Jisu Kim;Junghoon Lee
    • Journal of the Korean Electrochemical Society
    • /
    • v.27 no.1
    • /
    • pp.8-14
    • /
    • 2024
  • Austenitic stainless steel 316L has been used a lot of applications because of its high corrosion resistance and formability. In addition, copper brazing is employed to create complex shape of 316L stainless steel for various engineering parts. In such system, copper-based filler metals make galvanic cell at metal/filler metal interface, and it accelerates corrosion of stainless steel. Furthermore, Cu-rich region formed by diffused copper in austenitic stainless steel can promote a pitting corrosion. In this study, we used an ammonia (NH3) gas to nitride the 316L stainless steel for improving the corrosion resistance. The thickness of the nitride (nitrogen high) layer increased with the treatment temperature, and the surface hardness also increased. The potentiodynamic polarization test showed the improvement of corrosion resistance of 316L stainless steel by enhancing the passivation on nitride layer. However, in case of high temperature nitriding, a chromium nitride was formed and its fraction increased, so that the corrosion resistance was decreased compared to the intact 316L stainless steel.

Evaluation of the Cytotoxicity and Mechanical Strength of Dental Duplex Stainless Steel Orthodontic Wire (치과 교정용 듀플렉스 스테인리스 스틸 와이어의 기계적 강도 및 세포독성 평가)

  • Lee, Myung-Kon;Kim, Chi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.309-317
    • /
    • 2010
  • The stainless steel wire is extensively used for the orthodontic treatment. But, the stainless steel wire that has commonly superior corrosion resistance has caused hypersensitive reaction or allergy as side effects because of corrosion in the oral environment. For improving the problem of corrosion, we was evaluated the suitability of the duplex stainless steel(DSS) as orthodontic wire through this study. The DSS wire was evaluated the mechanical strength and bio-stability for suitability and bio-compatibility as orthodontic wire. In this work, the DSS and stainless steel(SS) as common use of medical grade were prepared for the tensile strength test. The DSS wire were treated by heat. and Temperature conditions of the heat treatment were $28^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$, $800^{\circ}C$, $900^{\circ}C$, respectively. And the DSS wires that treated by heat on the optimum temperature condition were conducted the bending moment test and calculated the S-Max value and the modulus of elasticity. For evaluating the bio stability, each materials were conducted in vitro test for measuring the cell survival rate. The most interesting results was that the tensile strength test of SS wire($8.17\times10^4\;N/mm^2$) and DSS wire($8.05\times10^4\;N/mm^2$) that treated at $500^{\circ}C$ by heat were similar in mechanical strength. In the bio-stability study, the DSS has no cytotoxicity (p=0.05) Thus, we could make a conclusion that the duplex stainless steel wire has vastly superior corrosion resistance was suitable as orthodontic wire.

Cutting Characteristics and Deformed Layer of Type 316LN Stainless Steel (Type 316LN 스테인리스강의 절삭특성과 가공 변질층)

  • Oh, Sun-Sae;Yi, Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.2
    • /
    • pp.196-205
    • /
    • 2004
  • The cutting characteristics and the deformed layer of nitrogen(N)-added type 316LN stainless steel were comparatively investigated to type 316L stainless steel. The cutting force, the surface roughness(Ra) and the tool wear in face milling works were measured with cutting conditions, and the deformed layers were obtained from micro-hardness testing method. The cutting resistance of type 316LN was similar to type 316L in spite of its high strength. The surface roughness of type 316LN was superior to type 316L for all the cutting conditions. In particular, in the high cutting speed above 345m/min, the surface roughness of the two stainless steels was closely same. The deformed layer thickness of the two stainless steels was generated in the 150$\mu\textrm{m}$-300$\mu\textrm{m}$ ranges, and its value of type 316LN was lower than that of type 316L. This is due to the high strength properties by nitrogen effect. It was found that type 316LN was higher in the tool wear than that type 316L, and flank wear was dominant to crater wear. In face milling works of type 316LN steel, tool wear is regarded as a important problem.

Multiaxial ratcheting assessment of Z2CND18.12N steel using modified A-V hardening rule

  • Xiaohui Chen;Yang Zhou;Wenwu Liu;Xu Zhao
    • Steel and Composite Structures
    • /
    • v.49 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • Based on Ahmadzadeh-Varvani hardening rule (A-V model), multiaxial ratcheting effect of Z2CND18.12N austenitic stainless steel is simulated by ABAQUS with user subroutine UMAT. The results show that the predicted results of the origin multiaxial A-V model are lower than the experimental data, and it is difficult to control ratcheting strain rate. In order to improve the predicted capability of A-V model, the A-V model is modified. In this study. Moreover, under the assumption of the von Mises yield criterion and normal plasticity flow rule, we develop a numerical algorithm of plastic strain with the improved model to implement the finite element calculation of the model. Internal iteration in the numerical algorithm was implemented with the Euler backward method, which calculated the trial strain for each equilibrium iteration using the consistent tangent matrix. With a user subroutine, the proposed model is programmed into ABAQUS for a user - executable version. By simulating the uniaxial ratcheting of a round bar made of Z2CND18.12N austenitic stainless steel, we observe that the predicted results simulated by ABAQUS with UMAT are compared with the experimental data. The predicted results of the improved multiaxial A-V model are consistent well with the experimental data.

Constitutive model for ratcheting behavior of Z2CND18.12N austenitic stainless steel under non-symmetric cyclic stress based on BP neural network

  • Wang, Xingang;Chen, Xiaohui;Yan, Mingming;Chang, Miaoxin
    • Steel and Composite Structures
    • /
    • v.28 no.5
    • /
    • pp.517-525
    • /
    • 2018
  • The specimens made by Z2CND18.12N austenitic stainless steel were conducted on a 100 kN closed loop servo hydraulic tension-compression testing machine with a digital controller. Uniaxial tension and uniaxial ratcheting effect tests were carried out at $25^{\circ}C$. Moreover, Uniaxial tension tests were conducted at $150^{\circ}C$, $250^{\circ}C$ and $350^{\circ}C$. Based on these experimental data, the prediction models of stress-strain curve and the relationship of ratcheting strain and number of cycles were established by the algorithm principle of BP neural network. The results indicated that the predicted results of neural network model were in well agreement with experimental data. It was found that the BP neural network model had high validity and accuracy.