• Title/Summary/Keyword: N:P ratio(N:P)

Search Result 3,033, Processing Time 0.038 seconds

Water Quality and Chlorophyll-a at the Birth Stage of a Large Reclaimed Estuarine Lake in Korea (Lake Hwaong) (간척하구호 (화옹호) 태동기의 수질과 엽록소-a 변화)

  • Kim, Ho-Sub;Chung, Mi-Hee;Choi, Chung-Il;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.4 s.105
    • /
    • pp.455-462
    • /
    • 2003
  • This study evaluated the change of water quality and chlorophyll - a at the birth stage of a large reclaimed estuarine lake (Lake Hwaong) of which the dike was finally constructed in March, 2002. Physico -chemical parameters and chlorophyll - a were investigated along a longitudinal transect, including 3 in-lake sites and 1 out-lake site from June to November, 2002. Salinity at all in-lake sites was over 21 psu during the study period, indicating that lake is still in the seawater phase. Salinity was periodically diluted at times when precipitation was high, especially in August. Chemocline was established in July near the dam site, and correspondingly vertical profile of dissolved oxygen was very clear during that Period. Total nitrogen and phosphorus concentrations at all lake sites were in the eutrophic range, and they were especially high at the stream inlet site. Nutrients concentration was not much varied vertically but significantly varied temporally, and correlated significantly with precipitation and chlorophyll-a concentration, indicating that inflowing water from the watershed seemed not to improve lake water by dilution but cause eutrophication of the lake, and thereby stimulate phytoplankton development. Based on the analyses of nutrient ratio (N/P) and trophic state deviation, both phosphorus and nitrogen appeared to limit phytoplankton growth in the lake. Phosphorus limitation appeared to be probable at all in-lake sites with being most severe at the stream inlet site. Nitrogen limitation seemed to occur at both in-lake and out-lake sites. These results indicate that in Lake Hwaong experiencing the very early stage of a reclaiming lake, water quality and phytoplankton development appear to be affect-ed largely by salinity and hydrology and nutrients from the inflowing water. Lake biogeochemistry is still very unstable, and thus further long-term study is necessary to understand the effects of seawater to freshwater conversion on lake biology and water chemistry.

Local Environments of Li in the Interlayer of Clay Minerals at Room and High Temperatures (상온 및 고온에서 점토광물 층간의 Li 환경)

  • Kim, Yeong-Kyoo;Lee, Ji-Eun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.193-201
    • /
    • 2007
  • We used $^6Li$ and $^7Li$ MAS NMR to investigate the fate and local environments of Li in the interlayer of clay minerals such as hectorite, Woming-montmorillonite, beidellite, and lepidollite at room and high ($250^{\circ}C$) temperature. Although $^6Li$ NMR spectra show narrower peaks than those of $^7Li$ NMR, S/N ratio is low and there are no obvious differences in chemical shifts suggesting that it is difficult to apply $^6Li$ NMR to have information on the local environments of Li in the clay interlayers. $^7Li$ NMR spectra, however, show changes in the peak width and quadrupole patterns providing information on the local environments of Li in the interlayer even though changes in the chemical shift are not observed. In montmorillonite, two different local environments of Li are observed; one has a narrow peak with typical quadrupole patterns whereas another has a broad peak without those of the patterns. Changes in the peak width is also observed from broad to narrow in the $^7Li$ NMR spectra for beidellite but not for hectorite at high temperature. Our results suggest that the peak width change in the broad peak is attributed to the coordination changes in the water molecules around Li which is tightly bonded on the basal oxygen of Si tetrahedra as inner-sphere complexes. The narrow peak in montmorillnoite can be assigned to the Li bended as outer-sphere complexes.

Influence of Daytime Temperature on the Time Required for Fruit Harvest and Yield of Hot Pepper (주간온도가 고추의 수확 소요일수 및 수량에 미치는 영향)

  • Lee, Sang-Gyu;Choi, Chang-Sun;Lee, Jun-Gu;Jang, Yoon-Ah;Nam, Chun-Woo;Lee, Hee-Ju;Suh, Jeong-Min;Kang, Jum-Soon
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1181-1186
    • /
    • 2013
  • Due to climate change, the occurrence of abnormal weather conditions has become more frequent, causing damage to vegetable crops grown in Korea. Hot pepper, Chinese cabbage and radish, the three most popular vegetables in Korea, are produced more in the field than in the greenhouse. It has been a trend that the time for field transplanting of seedlings is getting earlier and earlier as the spring temperatures keep rising. Seedlings transplanted too early in the spring take a longer time to resume the normal growth, because they are exposed to suboptimal temperature conditions. This study examined the influence of air temperature during seedling growth on the time required to reach the first fruit maturity and yield of hot pepper. Seedling plants of 'Super Manita' hot pepper was grown in temperatures $2.5^{\circ}C$ and $5.0^{\circ}C$ lower than the optimum temperature (determined by the average of temperatures for the past 5 years). Seedlings were transplanted into round plastic containers (30-cm diam., 45-cm height) and were placed in growth chambers in which the ambient temperature was controlled under natural sunlight. The growth of seedlings under lowered temperatures was reduced compared to the control. The mineral (K, Mg, P, N) concentrations in the leaf tissues were higher when plants were grown with the ambient temperature $2.5^{\circ}C$ lower than the optimum, regardless of changes in other growth parameters. Tissue calcium (Ca) concentration was the highest in the plants grown with optimum temperature. The carbohydrate to nitrogen (C/N) ratio, which was the highest (18.3) in the plants grown with optimum temperature, decreased concomitantly as the ambient temperature was lowered $2.5^{\circ}C$ and $5.0^{\circ}C$. The yield of the early harvested fruits was also reduced as the ambient temperature became lower. The first fruit harvest date for the plants grown with optimum temperature (June 27) was 13 days and 40 days, respectively, earlier than that in plants grown with $2.5^{\circ}C$ (July 10) and $5.0^{\circ}C$ (Aug 6) lower ambient temperatures. The fruit yield per plant for the optimum temperature (724 g) was the greatest compared to those grown with $2.5^{\circ}C$ (446 g) and $5.0^{\circ}C$ (236 g) lower temperatures. The result of this study suggests that the growers should be cautioned not to transplant their hot pepper seedlings too early into the field, since it may delay the time of first harvest eventually reducing total fruit yield.

Soft tissue changes associated with advancement genioplasty in skeletal class III individuals receiving mandibular set-back surgery (골격성 III급 부정교합자에서 전진이부성헝술을 동반한 하악 후퇴술 후 연조직 외형의 변화)

  • Kim, Keun-Ryoung;Kim, Seong-Sik;Son, Woo-Sung;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.38 no.2
    • /
    • pp.104-120
    • /
    • 2008
  • Purpose: The purpose of this study was to assess the hard and soft tissue changes associated with mandibular bilateral sagittal split osteotomy and genioplasty. Methods: This is a retrospective study of 40 patients who underwent either bilateral sagittal split osteotomy for mandibular setback (BSSO group, n = 20) or in combination with advancement genioplasty (Genio group, n = 20). Lateral radiographs, were taken before and immediately after surgery, and at least 6 months after surgery. Results: Comparing hard and soft tissue changes between the BSSO group and Genio group, there were significant differences in the lower incisor, soft tissue B point (B'), and soft tissue Pogonion (Pg') (p < 0.5). The mean ratio of hard and soft tissue changes for B/B', Pg/Pg', and Menton/soft tissue Menton after surgery in the BSSO group was 0.997, 0.965, and 1.022 respectively, and 0.824, 0.602, and 0.887 respectively in the genio group. Significant differences were found between the two groups. There were significant differences in lip thickness (B-B', Pg-Pg') in the Genioplasty group between pre and postsurgery, but not in the BSSO group. Pogonion to Labrale inferior and B' had a correlation coefficient of 0.833, 0.922, respectively for the BSSO group, and 0.775, 0.799 for the Genio group. Conclusions: The results indicate that there is a significant difference between bilateral sagittal split osteotomy with or without genioplasty in the lower facial esthetics values. The combination of mandibular setback and genioplasty had a smaller change in soft tissue thickness of the symphysis area after surgery than that of mandibular setback only.

Bioecological Characteristics of Coral Habitats around Moonsom, Cheju Island, Korea I. Environment Properties and Community Structures of Phytoplankton (제주도 문섬 산호서식지 주변의 생물생태학적 특성 I. 환경특성과 식물플랑크톤의 군집구조)

  • Choa, Jong-Hun;Lee, Joon-Baek
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.1
    • /
    • pp.59-69
    • /
    • 2000
  • Environmental factors and phytoplankton community have been bimonthly investigated in order to clarify the bioecological characteristics of coral habitats around Moonsom at the southern Cheju Island from September 1995 to July 1996. Annual mean temperature and annual mean salinity were $17.4^{\circ}C$ and 34.06 psu, respectively, showing lower temperature-higher salinity in winter and higher temperature-lower salinity in summer, which means such conditions are inadequate for coral reef formation. Nutrient concentrations represent that total nitrogen ranged from $0.07{\sim}10.08\;{\mu}M$, phosphate from $0.05{\sim}1.70\;{\mu}M$, and silicate from $3.08{\sim}21.86\;{\mu}M$. The N/P ratio showed the range of 9.59-10.60 with decreasing offshore-ward, which means the phytoplankton community could be limited by nitrogen sources. Annual mean euphotic depth was 32.0m (18.9m-48.6m) with difference according to season and reveals the close relationship with the depth of coral distribution. Chlorophyll a concentrations of phytoplankton ranged from $0.12{\sim}1.51\;{\mu}g\;L^{-1}$ and standing crops from $1.5{\times}10^3{\sim}7.0{\times}10^5\;cells\;L^{-1}$, showing higher at inshore than at offshore with a blooming in May. A total of 128 species of phytoplankton occurred in all stations, representing 99 spp. of diatoms, 26 spp. of dinoflagellates, 2 spp. of silicoflagellates and 1 sp. of blue-green algae. Diatoms are main taxa in all seasons except for occupying by dinoflagellates in summer. Among dominant species, fParalia sulcata (Ehrenberg) Cleve and Cylindrotheca closterium (Ehrenberg) Lewin & Reimann were predominant and are likely to be main food sources for coral community. Annual mean species diversity index (H') was 1.84, showing lower than around the coast line of Cheju Island.

  • PDF

Studies on the Natural Distribution and Ecology of Ilex cornuta Lindley et Pax. in Korea (호랑가시나무의 천연분포(天然分布)와 군낙생태(群落生態)에 관한 연구(研究))

  • Lee, Jeong Seok
    • Journal of Korean Society of Forest Science
    • /
    • v.62 no.1
    • /
    • pp.24-42
    • /
    • 1983
  • To develop Ilex cornuta which grow naturally in the southwest seaside district as new ornamental tree, the author chose I. cornuta growing in the four natural communities and those cultivated in Kwangju city as a sample, and investigated its ecology, morphology and characteristics. The results obtained was summarized as follows; 1) The natural distribution of I. cornuta marks $35^{\circ}$43'N and $126^{\circ}$44'E in the southwestern part of Korea and $33^{\circ}$20'N and $126^{\circ}$15'E in Jejoo island. This area has the following necessary conditions for Ilex cornuta: the annual average temperature is above $12^{\circ}C$, the coldness index below $-12.7^{\circ}C$, annual average relative humidity 75-80%, and the number of snow-covering days is 20-25 days, situated within 20km of from coastline and within, 100m above sea level and mainly at the foot of the mountain facing the southeast. 2) The vegetation in I. cornuta community can be divided that upper layer is composed of Pinus thunbergii and P. densiflora, middle layer of Eurya japonica var. montana, Ilex cornuta and Vaccinium bracteatum, and the ground vegetation is composed of Carex lanceolata and Arundinella hirta var. ciliare. The community has high species diversity which indicates it is at the stage of development. Although I. cornuta is a species of the southern type of temperate zone where coniferous tree or broad leaved, evergreen trees grow together, it occasionally grows in the subtropical zone. 3) Parent rock is gneiss or rhyolite etc., and soil is acidic (about pH 4.5-5.0) and the content of available phosphorus is low. 4) At maturity, the height growth averaged $10.48{\pm}0.23cm$ a year and the diameter growth 0.43 cm a year, and the annual ring was not clear. Mean leaf-number was 11.34. There are a significant positive correlation between twig-elongation and leaf-number. 5) One-year-old seedling grows up to 10.66 cm (max. 18.2 cm, min. 4.0 cm) in shoot-height, with its leaf number 12.1 (max. 18, min), its basal diameter 2.24 mm (max. 4.0 mm, min. 1.0 mm) and shows rhythmical growth in high temperature period. There were significant positive correlations between stalk-height and leaf-number, between stalk-height and basal-diameter, and between number and basal diameter. 6) The flowering time ranged from the end of April to the beginning of May, and the flower has tetra-merouscorella and corymb of yellowish green. It has a bisexual flower and dioecism with a sexual ratio 1:1. 7) The fruit, after fertilization, grows 0.87 cm long (0.61-1.31 cm) and 0.8 cm wide (0.62-1.05 cm) by the beginning of May. Fruits begin to turn red and continue to ripen until the end of October or the beginning of November and remain unfading until the end of following May. With the partial change in color of dark-brown at the beginning of the June fruits begin to fall, bur some remain even after three years. 8) The seed acquision ratio is 24.7% by weight, and the number of grains per fruit averages 3.9 and the seed weight per liter is 114.2 gram, while the average weight of 1,000 seeds is 24.56 grams. 9) Seeds after complete removal of sarcocarp, were buried under ground in a fixed temperature and humidity and they began to develop root in October, a year later and germinated in the next April. Under sunlight or drought, however, the dormant state may be continued.

  • PDF

The Early Experience with a Laparoscopy-assisted Pylorus-preserving Gastrectomy: A Comparison with a Laparoscopy-assisted Distal Gastrectomy with Billroth-I Reconstruction (복강경 보조 유문부보존 위절제술의 초기 경험: 복강경 보조 원위부 위절제술 후 Billroth-I 재건술과의 비교)

  • Park, Jong-Ik;Jin, Sung-Ho;Bang, Ho-Yoon;Chae, Gi-Bong;Paik, Nam-Sun;Moon, Nan-Mo;Lee, Jong-Inn
    • Journal of Gastric Cancer
    • /
    • v.8 no.1
    • /
    • pp.20-26
    • /
    • 2008
  • Purpose: Pylorus-preserving gastrectomy (PPG), which retains pyloric ring and gastric function, has been accepted as a function-preserving procedure for early gastric cancer for the prevention of postgastrectomy syndrome. This study was compared laparoscopy-assisted pylorus-preerving gastrectomy (LAPPG) with laparoscopy-assisted distal gastrectomy with Billroth-I reconstruction (LADGB I). Materials and Methods: Between November 2006 and September 2007, 39 patients with early gastric cancer underwent laparoscopy-assisted gastrectomy in the Department of Surgery at Korea Cancer Center Hospital. 9 of these patients underwent LAPPG and 18 underwent LADGBI. When LAPPG was underwent, we preserved the pyloric branch, hepatic branch, and celiac branch of the vagus nerve, the infrapyloric artery, and the right gastric artery and performed D1+$\beta$ lymphadenectomy to the exclusion of suprapyloric lymph node dissection. The distal stomach was resected while retaining a $2.5{\sim}3.0\;cm$ pyloric cuff and maintaining a $3.0{\sim}4.0\;cm$ distal margin for the resection. Results: The mean age for patients who underwent LAPPG and LADGBI were $59.9{\pm}9.4$ year-old and $64.1{\pm}10.0$ year-old, respectively. The sex ratio was 1.3 : 1.0 (male 5, female 4) in the LAPPG group and 2.6 : 1.0 (male 13, female 5) in the LADGBI group. Mean total number of dissected lymph nodes ($28.3{\pm}11.9$ versus $28.1{\pm}8.9$), operation time ($269.0{\pm}34.4$ versus $236.3{\pm}39.6$ minutes), estimated blood loss ($191.1{\pm}85.7$ versus $218.3{\pm}150.6\;ml$), time to first flatus ($3.6{\pm}0.9$ versus $3.5{\pm}0.8$ days), time to start of diet ($5.1{\pm}0.9$ versus $5.1{\pm}1.7$ days), and postoperative hospital stay ($10.1{\pm}4.0$ versus $9.2{\pm}3.0$ days) were not found significant differences (P>0.05). The postoperative complications were 1 patient with gastric stasis and 1 patient with wound seroma in LAPPG group and 1 patient with left lateral segment infarct of liver in the LADGB I group. Conclusion: Patients treated by LAPPG showed a comparable quality of surgical operation compared with those treated by LADGBI. LAPPG has an important role in the surgical management of early gastric cancer in terms of quality of postoperative life. Randomized controlled studies should be undertaken to analyze the optimal survival and long-term outcomes of this operative procedure.

  • PDF

Nutritional Effects of Paper Board Sludge on the Soybean(Glycine max. L.) (대두(大豆)에 대(對)한 제지(製紙) Sludge의 영양학적(營養學的) 연구(昭究))

  • Kim, Moon Kyu;Chang, Ki Woon;Choi, Woo Young;Ham, Suon Kyu;Nam, Yun Kyu;Lee, Chang Jun
    • Korean Journal of Agricultural Science
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 1990
  • The paper board sludge(PBS) itself and compost sludge manure(CSM) mixed with sawdust, fowl droppings and urea to the PBS were treated to soybean plants to find the effects of growing characters, yield components, and nutritional compounds in the plant tissues. 1. Percentages of missing plants were 5-9% and 3.6-4.1% in the treatments of PBS and CSM, respectively. After that, the plants were restored to normal conditions. Anyway it is not desirable to use the paper board sludge and immature compost sludge manure in seeding time or to young seedlings. 2. Growth of the plant height was retarded in early growing phase, but it was normal in later stages. And the width and length of the largest leaf, numbers of main stem nodes and pods were not significant among the treatments. 3. The yield intends to increase through the treatments of 1,200, 1,600, and 2,000Kg PBS per 10a. In the CSM treatments with high rate of sawdust, fowl droppings and urea, the numbers of pods and grains were higher than the treatment of high content of PBS. 100-grain and one liter weights were opposite intention. It was suggested that the excess nitrogen amounts from the compost sludge manure than conventional fertilization affected to the yield components. 4. The contents of the main chemical compounds such as N, $P_2O_5$, $K_2O$, Ca, Mg were determined. The concentrations of nitrogen were higher in the treatment of PBS and CSM than none and control. 5. In conclusion, the nutritional effects of PBS were in evidence. To use the sludges, it should be fermented with adequate additives to improve the aeration, C/N ratio, activity of microbial, and other conditions. The sludges could be used to crops as a fertilizers effectively.

  • PDF

Clinical Outcomes of Corrective Surgical Treatment for Esophageal Cancer (식도암의 외과적 근치 절제술에 대한 임상적 고찰)

  • Ryu Se Min;Jo Won Min;Mok Young Jae;Kim Hyun Koo;Cho Yang Hyun;Sohn Young-sang;Kim Hark Jei;Choi Young Ho
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.157-163
    • /
    • 2005
  • Background: Clinical outcomes of esophageal cancer have not been satisfactory in spite of the development of surgical skills and protocols of adjuvant therapy. We analyzed the results of corrective surgical patients for esophageal cancer from January 1992 to July 2002. Material and Method: Among 129 patients with esophageal cancer, this study was performed in 68 patients who received corrective surgery. The ratio of sex was 59 : 9 (male : female) and mean age was $61.07\pm7.36$ years old. Chief complaints of this patients were dysphagia, epigastric pain and weight loss, etc. The locations of esophageal cancer were 4 in upper esophagus, 36 in middle, 20 in lower, 8 in esophagogastric junction. 60 patients had squamous cell cancer and 7 had adenocarcinoma, and 1 had malignant melanoma. Five patients had neoadjuvant chemotherapy. Result: The postoperative stage I, IIA, IIB, III, IV patients were 7, 25, 12, 17 and 7, respectively. The conduit for replacement of esophagus were stomach (62 patients) and colon (6 patients). The neck anastomosis was performed in 28 patients and intrathoracic anastomosis in 40 patients. The technique of anastomosis were hand sewing method (44 patients) and stapling method (24 patients). One of the early complications was anastomosis leakage (3 patients) which had only radiologic leakage that recovered spontaneously. The anastomosis technique had no correlation with postoperative leakage, which stapling method (2 patients) and hand sewing method (1 patient). There were 3 respiratory failures, 6 pneumonia, 1 fulminant hepatitis, 1 bleeding and 1 sepsis. The 2 early postoperative deaths were fulminant hepatitis and sepsis. Among 68 patients, 23 patients had postoperative adjuvant therapy and 55 paitents were followed up. The follow up period was $23.73\pm22.18$ months ($1\~76$ month). There were 5 patients in stage I, 21 in stage 2A, 9 in stage IIB, 15 in stage III and 5 in stage IV. The 1, 3, 5 year survival rates of the patients who could be followed up completely was $58.43\pm6.5\%,\;35.48\pm7.5\%\;and\;18.81\pm7.7\%$, respectively. Statistical analysis showed that long-term survival difference was associated with a stage, T stage, and N stage (p<0.05) but not associated with histology, sex, anastomosis location, tumor location, and pre and postoperative adjuvant therapy. Conclusion: The early diagnosis, aggressive operative resection, and adequate postoperative treatment may have contributed to the observed increase in survival for esophageal cancer patients.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF