• 제목/요약/키워드: N, N-Dimethyl-4-nitrosoaniline

검색결과 21건 처리시간 0.016초

Bioreduction of N,N-dimethyl-p-nitrosoaniline

  • Kim, Kyung-Soon;Shin, Hae-Yong
    • BMB Reports
    • /
    • 제34권3호
    • /
    • pp.225-229
    • /
    • 2001
  • Besides a variety of quinones, purified bovine liver quinone reductase catalyzed the reduction of N,N-p-nitrosoaniline to N,N-dimethyl-p-phenylenediamine. The formation of N,N-dimethyl-p-phenylenediamine was identified by TLC, GC, GC-MS and NMR. Quinone reductase can utilize either NADH or NADPH as a source of reducing equivalents. The apparent Km for 1,4-benzoquinone and N,N-dimethyl-p-nitrosoaniline was 1.64 mM and 0.22 mM, respectively The reduction of N,N-dimethyl-p-nitrosoaniline was almost entirely hampered by dicumarol or Cibacron blue 3GA, potent inhibitors of mammalian quinone reductase. During the bovine liver quinone reductase-catalyzed reduction of N,N-dimethyl-p-nitrosoaniline, benzoquinonediiminium ion was produced.

  • PDF

수처리용 유전체 장벽 방전 플라즈마 반응기 개발 (Development of Plasma Reactor of Dielectric Barrier Discharge for Water Treatment)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제21권5호
    • /
    • pp.597-603
    • /
    • 2012
  • Non-thermal plasma processing using a dielectric barrier discharge (DBD) has been investigated as an alternative method for the degradation of non-biodegradable organic compounds in wastewater. The active species such as OH radical, produced by the electrical discharge may play an important role in degrading organic compound in water. The degradation of N, N-Dimethyl-4-nitrosoaniline (RNO) was investigated as an indicator of the generation of OH radical. The DBD plasma reactor of this study consisted of a plasma reactor, recycling pump, power supply and reservoir. The effect of diameter of external reactor (15 ~ 40 mm), width of ground electrode (2.5 ~ 30 cm), shape (pipe, spring) and material (copper, stainless steel and titanium) of ground electrode, water circulation rate (3.1 ~ 54.8 cm/s), air flow rate (0.5 ~ 3.0 L/min) and ratio of packing material (0 ~ 100 %) were evaluated. The experimental results showed that shape and materials of ground were not influenced the RNO degradation. Optimum diameter of external reactor, water circulation rate and air flow rate for RNO degradation were 30 mm, 25.4 cm/s and 4 L/min, respectively. Ground electrode length to get the maximum RNO degradation was 30 cm, which was same as reactor length. Filling up of glass beads decreased the RNO degradation. Among the experimented parameters, air flow rate was most important parameters which are influenced the decomposition of RNO.

Boron-doped Diamond 전극을 이용한 Rhodamine B와 N, N-Dimethyl-4-nitrosoanilin의 전기화학적 분해에 반응표면분석법의 적용과 공정 최적화 (Application of the Response Surface Methodology and Process Optimization to the Electrochemical Degradation of Rhodamine B and N, N-Dimethyl-4-nitrosoanilin Using a Boron-doped Diamond Electrode)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제36권4호
    • /
    • pp.313-322
    • /
    • 2010
  • The aim of this research was to apply experimental design methodology to optimization of conditions of electrochemical oxidation of Rhodamine B (RhB) and N, N-Dimethyl-4-nitrosoaniline (RNO, indicative of the OH radical). The reactions of electrochemical oxidation of RhB degradation were mathematically described as a function of the parameters of current ($X_1$), NaCl dosage ($X_2$) and pH ($X_3$) and modeled by the use of the central composite design. The application of response surface methodology (RSM) yielded the following regression equation, which is an empirical relationship between the removal efficiency of RhB and RNO and test variables in a coded unit: RhB removal efficiency (%) = $94.21+7.02X_1+10.94X_2-16.06X_3+3.70X_1X_3+9.05X_2X_3-{3.46X_1}^2-{4.67X_2}^2-{7.09X_3}^2$; RNO removal efficiency (%) = $54.78+13.33X_1+14.93X_2- 16.90X_3$. The model predictions agreed well with the experimentally observed result. Graphical response surface and contour plots were used to locate the optimum point. The estimated ridge of maximum response and optimal conditions for the RhB degradation using canonical analysis was 100.0%(current, 0.80 A; NaCl dosage, 2.97% and pH 6.37).

전기분해 공정을 이용한 E. coli 소독에 미치는 인공하수 수질의 영향 (Effect of Water Quality of Artificial Sewage on E. coli Disinfection Using Electrolysis Process)

  • 박영식;김동석
    • 한국환경과학회지
    • /
    • 제20권9호
    • /
    • pp.1115-1124
    • /
    • 2011
  • There is an increasing incidence in health problems related to environmental issues that originate from inadequate treatment of sewage. This has compelled scientists to engage in innovative technologies to achieve a effective disinfection process. Electrolysis has emerged as one of the more feasible alternatives to conventional disinfection process. The objectives of the present paper were to investigate the effect of chemical characteristics on oxidant formation and Escherichia coli (E. coli) disinfection in synthetic sewage effluents. The influence of parameters such as COD, SS, T-N and T-P were investigated using laboratory scale batch reactor. The results showed that the higher COD, T-N and T-P concentration, the lower N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) degradation and E. coli disinfection was observed. The order of effect of RNO degradation and E. coli disinfection was T-P > COD > T-N > SS. When 4 parameter of water quality were worked simultaneously, oxidants formation and disinfection was decreased with increase of the concentration of sewage. To increase of the disinfection performance, the increase of disinfection time or electric power was need.

복합 소독 공정을 이용한 E. coli 불활성화 (E. coli Inactivation using Complex Disinfection Process)

  • 김동석;박영식
    • KSBB Journal
    • /
    • 제25권1호
    • /
    • pp.33-40
    • /
    • 2010
  • Conventional disinfectants and disinfection method are expensive, hazardous and often require long periods of exposure. Recently, there is growing interest in complex disinfection process as a disinfection technique in medical instruments such as endoscope, hand piece bur to improve the disinfection efficiency and conveniency. The aim of this study was to evaluate the performance of a new complex process for the purpose of disinfection of Escherichia coli in water. Three single process (electrolysis, UV and ultrasonic process) was combined dual and triple disinfection process. The order of disinfection performance for E. coli in dual process lie in: Electrolysis + UV > Electrolysis + Ultrasonic > UV + Ultrasonic process. Disinfection efficiency of E. coli and degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicating material of OH radical formation) of dual process was higher than that of the triple process (Electrolysis + UV + Ultrasonic process). In electrolysis + UV process, disinfection tendency was well agreed with RNO degradation tendency.

수처리용 유전체장벽 플라즈마 반응기에 대한 기초 연구 (A Basic Study of Plasma Reactor of Dielectric Barrier Discharge for the Water Treatment)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.623-630
    • /
    • 2011
  • This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) by using dielectric barrier discharge (DBD) plasma. The DBD plasma reactor of this study consisted of a quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode. The effect of shape (rod, spring and pipe) of ground electrode, diameter (9~30 mm) of ground electrode of spring shape and inside diameter (4~13 mm) of quartz tube, electrode diameter (1~4 mm), electrode materials (SUS, Ti, iron, Cu and W), height difference of discharge and ground electrode (1~15.5 cm) and gas flow rate (1~7 L/min) were evaluated. The experimental results showed that shape of ground electrode and materials of ground and discharge electrode were not influenced the RNO degradation. The thinner the diameter of discharge and ground electrode, the higher RNO degradation rate observed. The effect of height gap of discharge between ground electrode on RNO degradation was not high within the experimented value. Among the experimented parameters, inside diameter of quartz tube and gas flow rate were most important parameters which are influenced the decomposition of RNO. Optimum inside diameter of quartz tube and gas flow rate were 7 mm and 4 L/min, respectively.

공기-플라즈마 방전 시스템에서 화학적 활성종의 생성에 대한 연구 (Study on the Generation of Chemically Active Species using Air-plasma Discharging System)

  • 김동석;박영식
    • 한국물환경학회지
    • /
    • 제28권3호
    • /
    • pp.401-408
    • /
    • 2012
  • High-voltage dielectric discharges are an emerging technique in environmental pollutant degradation, which that are characterized by the production of hydroxyl radicals as the primary degradation species. The initiation and propagation of the electrical discharges depends on several physical, chemical, and electrical parameters such as 1st and 2nd voltage of power, gas supply, conductivity and pH. These parameters also influence the physical and chemical characteristics of the discharges, including the production of reactive species such as OH, $H_2O_2$ and $O_3$. The experimental results showed that the optimum 1st voltage and air flow rate for RNO (N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation were 160 V (2nd voltage of is 15 kV) and 4 L/min, respectively. As the increased of the 2nd voltage (4 kV to 15 kV), RNO degradation, $H_2O_2$ and $O_3$ generation were increased. The conductivity of the solution was not influencing the RNO degradation and $H_2O_2$ and $O_3$ generation. The effects pH was not high on RNO degradation. However, the lower pH and the conductivity, the higher $H_2O_2$ and $O_3$ generation were observed.

3구 노즐을 이용한 플라즈마 가스 용존율 향상을 위한 플라즈마 공정의 최적화 (Optimization of Plasma Process to Improve Plasma Gas Dissolution Rate using Three-neck Nozzle)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제30권5호
    • /
    • pp.399-406
    • /
    • 2021
  • The dissolution of ionized gas in dielectric barrier plasma, similar to the principle of ozone generation, is a major performance-affecting factor. In this study, the plasma gas dissolving performance of a gas mixing-circulation plasma process was evaluated using an experimental design methodology. The plasma reaction is a function of four parameters [electric current (X1), gas flow rate (X2), liquid flow rate (X3) and reaction time (X4)] modeled by the Box-Behnken design. RNO (N, N-Dimethyl-4-nitrosoaniline), an indictor of OH radical formation, was evaluated using a quadratic response surface model. The model prediction equation derived for RNO degradation was shown as a second-order polynomial. By pooling the terms with poor explanatory power as error terms and performing ANOVA, results showed high significance, with an adjusted R2 value of 0.9386; this indicate that the model adequately satisfies the polynomial fit. For the RNO degradation, the measured value and the predicted values by the model equation agreed relatively well. The optimum current, gas flow rate, liquid flow rate and reaction time were obtained for the highest desirability for RNO degradation at 0.21 A, 2.65 L/min, 0.75 L/min and 6.5 min, respectively.

PbO2 전극을 이용한 산화제 생성과 염료 Rhodaime B 제거 (Formation of Oxidants and Removal of Dye Rhodamine B using PbO2 Electrode)

  • 박영식
    • 한국물환경학회지
    • /
    • 제27권2호
    • /
    • pp.194-199
    • /
    • 2011
  • This study has been carried out to evaluate the performance of $PbO_2$ electrode for the purpose of degradation of N,N-Dimethyl-4-nitrosoaniline (RNO, indicator of OH radical), generation of ozone and decolorization of Rhodamine B (RhB) in water. The effect of the applied current (0.2~1.2 A), electrolyte type (NaCl, KCl and $Na_2SO_4$), electrolyte concentration (0.0~2.5 g/L) and solution pH (3~11) were evaluated. Experimental results showed that RhB and RNO removal were increased with the increase of current, NaCl dosage and decrease of pH. Ozone generation tendencies appeared with the almost similar to the RhB and RNO degradation, except of solution pH (Ozone generation was increased with increase of pH). Optimum current for RhB degradation and consumption of electric power was 1.0 A. The RhB degradation with Cl type electrolyte were higher than that with the sulfate type. Optimum NaCl dosage for RhB degradation was 1.0 g/L.

실험계획법을 이용한 가스 혼합-순환식 플라즈마 공정의 최적화 (Optimization of Gas Mixing-circulation Plasma Process using Design of Experiments)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.359-368
    • /
    • 2014
  • The aim of our research was to apply experimental design methodology in the optimization of N, N-Dimethyl-4-nitrosoaniline (RNO, which is indictor of OH radical formation) degradation using gas mixing-circulation plasma process. The reaction was mathematically described as a function of four independent variables [voltage ($X_1$), gas flow rate ($X_2$), liquid flow rate ($X_3$) and time ($X_4$)] being modeled by the use of the central composite design (CCD). RNO removal efficiency was evaluated using a second-order polynomial multiple regression model. Analysis of variance (ANOVA) showed a high coefficient of determination ($R^2$) value of 0.9111, thus ensuring a satisfactory adjustment of the second-order polynomial multiple regression model with the experimental data. The application of response surface methodology (RSM) yielded the following regression equation, which is an empirical relationship between the RNO removal efficiency and independent variables in a coded unit: RNO removal efficiency (%) = $77.71+10.04X_1+10.72X_2+1.78X_3+17.66X_4+5.91X_1X_2+3.64X_2X_3-8.72X_2X_4-7.80X{_1}^2-6.49X{_2}^2-5.67X{_4}^2$. Maximum RNO removal efficiency was predicted and experimentally validated. The optimum voltage, air flow rate, liquid flow rate and time were obtained for the highest desirability at 117.99 V, 4.88 L/min, 6.27 L/min and 24.65 min, respectively. Under optimal value of process parameters, high removal(> 97 %) was obtained for RNO.