• Title/Summary/Keyword: Myocardium uptake

Search Result 39, Processing Time 0.019 seconds

Effects of Potassium-Channel Opener on Thallium-201 Kinetics: In-vitro Study in Rat Myocyte Preparations and In-vivo Mice Biodistribution Study (K-통로개방제가 배양심근세포와 생쥐 체내의 Thallium-201역동학에 미치는 영향)

  • Lee, Jae-Tae;Kim, Eun-Ji;Ahn, Byeong-Cheol;Sohn, Kang-Kyun;Lee, Kyu-Bo;Ha, Jeoung-Hee;Kim, Chun-K.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.507-515
    • /
    • 1996
  • Background : Potassium channel opener (K-opener) opens ATP-sensitive K'-channel located at cell membrane and induces potassium efflux from cytosol, resulting in intracellular hyperpolarization. Newly synthesized K-opener is currently examined for pharmacologic potency by means of rubidium release test from smooth muscle strip pre-incubated with Rb-86. Since in-vivo behavior of thallium is similar to that of rubidium, we hypothesized that K-opener can alter T1-201 kinetics in vivo. Purpose : This study was prepared to investigate the effects of pinacidil (one of potent K-openers) on the T1-201 uptake and clearance in cultured myocyte, and in-vivo biodistribution in mice. Methods : Spontaneous contracting myocytes were prepared to imitate in-vivo condition from 20 hearts of 3-5 days old Sprague-Dawley rat and cultured for 3-5 days before use ($5{\times}10^5$ cells/ml). Pinacidil was dissolved in 10% DMSO solution at a final concentration of 100nM or l0uM and was co-incubated with T1-201 in HBSS buffer for 20-min to evaluate its effect on cellular T1-uptake, or challenged to cell preparation pre-incubated with T1-201 for washout study. Two, 40 or $100{\mu}g$ of pinacidil was injected intravenously into ICR mice at 10 min after $5{\mu}Ci$ T1-201 injection, and organ uptake and whole body retention rate were measured at different time points. Results : Co-incubation of pinacidil with T1-201 resulted in a decrease in T1-201 uptake into cultured myocyte by 1.6 to 2.5 times, depending on pinacidil concentration and activity of T1-201 used. Pinacidil enhanced T1-201 washout by 1.6-3.1 times from myocyte preparations pre-incubated with T1-201. Pinacidil treatment appears to be resulted in mild decreases in blood and liver activity in normal mice, in contrast, renal and cardiac uptake were mildly decreased in a dose dependent manner. Whole body retention ratios of T1-201 were lower at 24 hour after injection with $100{\mu}g$ of pinacidil than control. Conclusion : These results suggest that treatment with K-opener may affect the interpretation of T1-201 myocardial images, due to decreasing thallium accumulation and enhancing washout from myocardium.

  • PDF

Radius Intermedius Stenosis Induced Myocardial Perfusion Defect: Provened by the Fusion Images of Myocardial Perfusion SPECT and 64 Channel CTA (심근관류 SPECT와 64채널 전산화 단층혈관 촬영 사진 융합으로 증명된 radius intermedius 협착에 의한 심근관류 저하)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jong-Seon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.77-78
    • /
    • 2008
  • A 71-year-old woman was assigned to our department for Tc-99m myocardial perfusion SPECT(MPS) and coronary CT angiography. She admitted for substernal pain, via the ER, 2 days ago. The heart was scanned after intravenous injection of 925 MBq of $^{99m}Tc$-sestamibi adenosine-induced stress SPECT using dual head gamma camera (Hawkeye, GE healthcare. USA). The MPS shows decreased tracer uptake in the apical & mid area of anterior & lateral wall and mid & basal inferior wall. Coronary CT angiograph was obtained using Discovery VCT (GE healthcare). 3D angiography portrayed significant stenosis of ramus intermedius(RI) and posterolateral branch of right coronary artery(PLB) with fibrocalcified plaque. Two images were fused using Cardiac IQ fusion softwear package (Advantage workstation 4.4, GE healthcare) The fusion images explain the perfusion defect of anterior, lateral and inferior wall is due to stenosis of the RI and PLB. And 3 days later, coronary angiography was done and revealed the marked stenosis of RI and PLB. Then balloon angioplasty and stent was instituted in RI. Cardiac SPECT/CT fusion imaging provides additional information about hemodynamic relevance and facilitates lesion interpretation by allowing exact allocation of perfusion defects to its subtending coronary artery.

Synthesis of 18F-labeled Novel Phosphonium cations as PET Myocardial Perfusion Imaging Agents: Pilot Imaging Studies

  • Ayoung Pyo;Jung-Joon Min;Dong-Yeon Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.63-70
    • /
    • 2022
  • The development of myocardial perfusion imaging (MPI) agents has been motivated because coronary artery disease has been one of the leading causes of death worldwide since the 1960s. Several positron emission tomography (PET) MPI agents were developed, and 18F-labeled phosphonium cations were reported actively among them. In this study, we synthesized novel 18F-labeled phosphonium cations, (5-[18F]fluoropentyl)diphenyl(pyridin-2-yl)phosphonium and (2-(2-[18F]fluoroethoxy)ethyl)diphenyl(pyridin-2-yl)phosphonium, and evaluated potential as MPI agents. Two labeled compounds were synthesized via nucleophilic substitution reactions of 18F-fluoride with the appropriate tosylate precursor in the presence of Kryptofix 2.2.2 and K2CO3. MicroPET studies were performed in normal rats to evaluate in vivo distribution of radiolabeled phosphonium cations for 60 min. The radiolabeled compounds were synthesized with 5%-10% yield. The radiochemical purity of labeled compounds was > 98% by analytical HPLC, and the specific activity was > 11.8 GBq/µmol. The result of microPET studies of these labeled compounds in rats showed intense uptake in the myocardium at 30 and 60 min. The results suggest that these 18F-labeled novel phosphonium cations would have potential as promising candidates for myocardial perfusion imaging.

Functional Defect and Its Possible Mechanism of Diabetic Cardiomyopathy (당뇨성 심근질환에서의 근장그물 기능이상과 그 작용기전)

  • Kim, Hae-Won;Lee, Hee-Ran;Jang-Yang, Yeon-Jin;Park, Hyoung-Sup;Park, So-Young
    • The Korean Journal of Pharmacology
    • /
    • v.29 no.2
    • /
    • pp.195-202
    • /
    • 1993
  • Oxidative modification of cellular proteins and lipids may play a role in the development of diabetic complications. Diabetic cardiomyopathy has been suggested to be caused by the intracellular $Ca^{2+}$ overload in the myocardium, which is partly due to the defect of calcium transport of the cardiac sarcoplasmic reticulum (SR). In the present study, the possible mechanism of the functional defect of cardiac SR in diabetic rats was studied. Both of the maximal $Ca^{2+}$ uptake and the affinity for $Ca^{2+}$ were decreased in the diabetic rat SR in comparison with the control. To investigate whether the functional defect of the cardiac SR in streptozotocin-induced diabetic rat is associated with the oxidative changes of cardiac SR proteins, the carbonyl group content and glycohemoglobin levels were determined. The increase in carbonyl group content of cardiac SR (2.30 nmols/mg protein, DM; 1.78, control) and in glycohemoglobin level $(13{\sim}17%,\;DM;\;3{\sim}5%,\;control)$ were observed in the diabetics. The extent of increase in calcium transport by phospholamban phosphorylation was greater in the diabetic cardiac SR membranes than that in the control. The phosphorylation levels of phospholamban, as determined by SDS-PAGE and autoradiography with $[{\gamma}^{32}P]ATP$, were increased in diabetic cardiac SR. These results suggest that the impaired cardiac SR function in diabetic rat could be a consequence of the less-phosphorylation of phospholamban in the basal state, which is partly due to the depleted norepinephrine stores in the heart. Furthermore, the oxidative damages in cardiac SR membranes might be one of the additional factors leading to the diabetic cardiomyopathy.

  • PDF

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Lung Uptake of $^{99m}Tc-sestamibi$ during Routine Gated Exercise SPECT Imaging : Comparison with Left Ventricular Ejection Fraction and Severity of Perfusion Defect (일상적인 운동 부하 게이트 심근 관류 SPECT에서 $^{99m}Tc-sestamibi$ 폐섭취 : 좌심실 구혈률과 관류 결손 정도와의 비교)

  • Jeong, Shin-Young;Lee, Jae-Tae;Bae, Jin-Ho;Ahn, Byeong-Cheol;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.83-93
    • /
    • 2003
  • Background: Lung-to-heart uptake ratio (LHR) in $^{201}Tl-chloride$ myocardial perfusion scan is believed to be a reliable marker for left ventricular (LV) dysfunction, but the clinical value of LHR is controversial for $^{99m}Tc-MIBI$ imaging. Furthermore, most of results suggesting lung uptake of $^{99m}Tc-MIBI$ as a potential marker for LV dysfunction used immediate post-stress images, instead of routine images acquired 1 hour after tracer injection. The goal of our study was to investigate whether LHR evaluated with routine gated $^{99m}Tc-MIBI$ imaging can reflect the degree of perfusion defect or left ventricular performance. Subjects and Methods: 241 patients underwent exercise $^{99m}Tc-MIBI$ myocardial SPECT were classified into normal myocardial perfusion (NP, n=135) and abnormal myocardial perfusion (AP, n=106) group according to the presence of perfusion defect. LHR was calculated from anterior projection image taken at 1-hour after injection. Two legions of interest (ROIs) were placed on left lung above LV and on myocardium showing the highest radioactivity. Subjects were classified by left ventricular ejection fraction (LVEF), as Gr-I: >50%, Gr-II: 36-50%, Gr-III: <36% and by summed stress score (SSS), as Gr-A: <4, Gr-B: 4-8, Gr-C: 9-13, Gr-D: >13, LHR was compared among these groups. Results: In NP group(n=135), LHR, were higher in men than women ($men:\;0.311{\pm}0.03,\;women:\;0.296{\pm}0.03,\;p<0.05$). Significant difference, in LHR were found between NP and AP groups both for men and women ($men:\;0.311{\pm}0.03\;vs\;.\;0.331{\pm}0.06,\;women:\;0.296{\pm}0.03\;vs.\;0.321{\pm}0.07.\;p<0.05$). There were weak negative correlation between LHR and LVEF (r=-0.342, p<0.05) and weak positive correlation between LHR and SSS (r=0.478, p<0.05) in men, but not in women (LVEF: r=-0.279, p=0.100, SSS: r=0.276, p=0.103). Increased LHR was defined when for more than mean + 2SD value ($men{\geq}0.38,\;women{\geq}0.37$) of the LHR of the subject with normal perfusion. Increased LHR were observed more frequently in subjects with lower LVEF (Gr-I: 11.1%, Gr-II: 27.0%, Gr-III: 35.4%, p<0.05) and higher SSS(Gr-A: 14.0%, Gr-B: 5.7%, Gr-C: 18.2%, Gr-D: 40.7%, p<0.05). Conclusions: LHRs obtained from routine $^{99m}Tc-MIBI$ gated SPECT images were weakly correlated with LVEF and perfusion defect. Although significant overlaps were observed between normal and abnormal perfusion group, LHRs could be used as an indirect marker of severe perfusion defect or reduced left ventricular function.

Role of Redistribution and 24 Hour Reinjection Images to assess Myocardial Viability in Patients with Acute Myocardial Infarction (급성심근경색환자의 심근생존능 평가에 있어서 T1-201 재분포영상과 24시간 재주사영상의 역할)

  • Yoon, Seok-Nam;Pai, Moon-Sun;Park, Chan-H.;Yoo Myung-Ho;Choi, Byung-Il William
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.325-331
    • /
    • 1998
  • Purpose: We evaluated the importance of redistribution and 24 hour reinjection images in T1-201 SPECT assessment of myocardial viability after acute myocardial infarction (AMI). Materials and Methods: We performed dipyridamole stress-4 hour redistribution-24 hour reinjection T1-201 SPECT in 43 patients with recent AMI (4-16 days). The myocardium was divided into 16 segments and perfusion grade was measured visually with 4 point score from 0 to 3 (absent uptake to normal uptake). A perfusion defect with stress score 2 was considered moderate. A defect was considered severe if the stress score was 0 or 1 (absent uptake or severe perfusion decrease). Moderate defect on stress image were considered viable and segments with severe defect were considered viable if they showed improvement of 1 score or more on redistribution or reinjection images. We compared the results of viability assessment in stress-redistribution and stress-reinjection images. Results: On visual analysis, 344 of 688 segments (50%) had abnormal perfusion. Fifty two (15%) had moderate perfusion defects and 292 (85%) had severe perfusion defects on stress image. Of 292 severe stress defects, 53 were irreversible on redistribution and reversible on reinjection images, and 15 were reversible on redistribution and irreversible on reinjection images. Two hundred twenty four of 292 segments (76.7%) showed concordant results on stress-redistribution and stress-reinjection images. Therefore 24 hour reinjection image changed viability status from necrotic to viable in 53 segments of 292 severe stress defect (18%). However, myocardial viability was underestimated in only 5% (15/292) of severe defects by 24 hour reinjection. Conclusion: The 24 hour reinjection imaging is useful in the assessment of myocardial viability. It is more sensitive than 4 hour redistribution imaging. However, both redistribution and reinjection images are needed since they complement each other.

  • PDF

Viability Assessment with T1-201 Rest-24 hour Delay Redistribution SPECT before Coronary Artery Bypass Graft in Coronary Artery Diseases (관상동맥 질환에서 우회로 수술 전 T1-201 휴식-24시간 지연 심근 관류 SPECT를 이용한 심근생존능의 평가)

  • Yoon, Seok-Nam;Kim, Ki-Bong;Lee, Won-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Jung-Don;Koh, Chang-Soon;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.493-501
    • /
    • 1996
  • To assess contribution of T1-201 rest-24 hour delay redistribution in detection of viable myocardium, we studied the predictive value of this redistribution in 17 patients who peformed rest-24 hour delay perfusion SPECT before bypass surgery. Regional wall motion was compared with gated SPECT in 10 patients and echocardiography in 7 patients before and after bypass surgery. Rest and 24 hour delayed uptakes were scored from 0 (normal perfusion) to 3 (defect). In rest SPECT, 56 segments showed perfusion decrease. Thirty four segments(61%) improved after surgery and were defined as viable Nineteen(34%) segments had more uptake of T1-201 at 24 hour delay, and the other 37 segments did not. In 81%(25/31) of segments with mildly decreased perfusion, wall motion after bypass surgery improved, 57% (8/14) of segments with severely decreased perfusion improved, and 9%(1/11) of segments with defects improved. In 14 among 19 segments which had more T1-201 uptakes at 24 hour delay, wall motion was improved(positive predictive value of redistribution: 74%). 20 among 37 segments which had persistent decreases in rest-24 hour redistribution improved and 17 did not(negative predictive value: 46%). Segments having severe perfusion decrease or defects showed improved wall motion after surgery in 64%(7/11), if it had redistribution at delay. Segments with either mildly decreased uptake in resting or rest-delayed redistribution showed improved wall motion in 76%(32/42). Among the 14 segments which showed improvement in wall motion, 10 had partial reversibility in stress-rest images and the other 4 had persistent perfusion defects in stress-rest images. These 4 segments were found viable only with rest-24 hour delayed perfusion SPECT. We concluded that rest T1-201 uptake or redistribution at 24 hour delay should be referred as an evidence to warrant postoperative improvement of abnormal wall motion and we could predict myocardial viability with preoperative rest-24 hour delay perfusion SPECT in the segments with rest perfusion decreases.

  • PDF

Myocardial Tracer Uptake in SPECT Images after Direct Intracoronary Injection Of TI-201: Comparison with Stress-Reinjection Images (관동맥내 주사 TI-201 SPECT에서 심근 분절의 섭취: 부하-재주사 TI-201 영상과의 비교)

  • Seo, Ji-Hyoung;Kang, Seong-Min;Bae, Jin-Ho;Lee, Yong-Jin;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Cho, Yong-Geun;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.291-298
    • /
    • 2007
  • Purpose: To investigate the feasibility of TI-201 SPECT with intra coronary injection (lC-I) in the detection of viable myocardium, we have performed SPECT imaging after direct intracoronary injection of TI-201 and images were compared with those of stress-reinjection (Re-I) SPECT. Methods: Fourteen coronary artery disease patients (male 11, mean age 54 years) who had myocardial infarction or demonstrated left ventricular wall motion abnormality on echocardiography were enrolled. Three mCi of TI-201 was injected into both coronary arteries during angiography and images were acquired between 6- and 24-hour after injection. Reinjection imaging with 1 mCi of TI-201 was performed at 4-hour after adenosine stress imaging with 3 mCi of TI-201. Images were interpreted according to 4-grade visual scoring system (grade 0-3). Segments with mild to moderated uptake (${\leq}$grade 1), and upgraded more than one score with reinjection, and were defined as viable myocardium. Results: Image quality was poor in two cases with IC-I. Numbers of non-viable segments were 60 (23.8%) with IC-I, and 38 (15.1%) with Re-I, respectively. Overall agreement for perfusion grade per myocardial segment in each IC-I and Re-I was 76.5%. Overall agreement for viable segment between IC-I and Re-I was 90.5%. Only one out of 38 segments interpreted as non-viable with Re-I were interpretated as viable with IC-I. And 23 out of 214 segments interpreted as viable with Re-I were interpreted as non-viable with IC-I. Conclusion: Intracoronary TI-201 SPECT seemed to be not advantageous over stress-rest reinjection imaging in the assessment of myocardial viability, mainly due to low count statistics at 6-hour or 24-hour delayed time points. The feasibility of intracoronary TI- 201 SPECT is considered to be limited.

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF