• 제목/요약/키워드: Myocardial perfusion

검색결과 274건 처리시간 0.029초

열공성 뇌경색 환자에게 발생한 폐색전증을 한양방 협진으로 치료한 1례 (Case of the Pulmonary Thromboembolism in a Patient with Lacunar Cerebral Infarction by the Integrated Therapy of Korean and Western Medicine)

  • 윤종민;이민구;이선우;강백규;이승언;김용정;손지우;이인;문병순;박세욱
    • 동의생리병리학회지
    • /
    • 제19권6호
    • /
    • pp.1676-1680
    • /
    • 2005
  • There are few topic about a pulmonary thromboembolism(PTE) especially in Korean medical research. This case report is dealt with a rare situation that a PTE and a lacunar infarction are complicated in one patient. They have a similarity in that both are caused by the thrombosis. The former is the thrombosis in lung and the latter is the cerebral infarcion within the territory of a single perforating artery Recently the attack rate of PTE somewhat grow because of the development of medicine such as the increasing use of indwelling catheters, trauma or surgery of pelvis and lower extrimity, major surgery especially in senior, the use of estrogen containing compounds, cerebrovascular disease, obesity, etc. A 70 year-old lady was stroked by the cerebral infarction and has been getting rehabilitating therapy. She had the sudden onset of dyspnea, chest pain and those symptoms looked like a myocardial infarction. But she was diagnosed as PTE by ventilation perfusion lung scan. We cured her with the integrated therapy of Korean and Western medicine.

Development of an exclusive column method for 82Sr/82Rb generator using a 100 MeV proton linear accelerator of KOMAC

  • Kye-Ryung Kim;Yeong Su Ha;Sang-Pil Yoon;Yeon-ji Lee;Yong-Sub Cho;Hyeongi Kim;Sang-Jin Han;Jung Young Kim;Kyo Chul Lee;Jin Su Kim
    • 대한방사성의약품학회지
    • /
    • 제7권2호
    • /
    • pp.119-125
    • /
    • 2021
  • 82Sr for 82Rb generator was produced through the irradiation of the proton beam on the nat.RbCI target at the target irradiation facility installed at the end of the Rl-dedicated beamline of the 100 MeV proton linear accelerator of KOMAC (Korea Multi-purpose Accelerator Complex). The average current of the proton beam was 1.2 µA for irradiation time of 150 min. For the separation and purification of the 82Sr from nat.RbCI irradiated, Chelex-100 resin was used. The activities of 82Sr in the irradiated nat.RbCI target solution and after purification were 45.29 µCi and 43.4 µCi, respectively. The separation and purification yield was 95.8%. As an adsorbent to be filled in the generator for 82Sr adsorption hydrous tin oxide was selected. The adsorption yield of 82Sr into the generator adsorbent was > 99 %, and the total amount of 82Sr adsorbed to the generator was 21.6 µCi as of the day of the 82Rb elution experiment. When the elution amount was 22 mL, the maximum82Rb elution yield was 93.3%, and the elution yield increased as the flow rate increased. After the eluted 82Rb was filled in the correction phantom of the small PET for animals, a PET image was taken. The image scan time was set to 5 min, and the phantom PET image was successfully obtained. As results of impurity analysis on eluted 82Rb using ICP-MS, nat.Rb stable isotopes that compete in vivo of 82Rb were identified as undetected levels and were determined to be No-Carrier-Added (NCA).

SPECT/CT에서 CT감쇠보정에 따른 영상의 질 평가 (Evaluation of Image Quality Using CT Attenuation Correction in SPECT/CT)

  • 조성욱;김계환;성용준;이형진;김진의
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.78-83
    • /
    • 2013
  • SPECT/CT는 SPECT와 CT를 결합하여 감약에 의한 왜곡된 영상을 CT의 감쇠보정을 이용하여 구현할 수 있는 장점이 있다. 감쇠보정을 이용한 SPECT/CT 영상은 우수한 의료 영상 정보를 제공하며 정확한 영상을 비교 및 판독할 수 있어서 영상의 진단적 가치가 높은 것으로 평가된다. 이 연구에서는 phantom 실험 및 환자의 영상을 이용하여 CT 감쇠보정 전후의 차이를 살펴보고자 한다. 2012년 7월부터 9월까지 본원 핵의학과에서 검사를 시행한 환자와 phantom을 이용하여 영상의 대조도와 공간분해능, 심근의 관류 점수를 연구하였다. NEMA IEC, Jaszczak phantom으로 영상의 대조도, triple line phantom으로 영상의 공간분해능, anthropomorphic torso phantom을 사용하여 심근의 관류 점수를 평가하였다. 또한 환자들의 검사 영상을 통하여 CT 감쇠보정 전후를 핵의학 전공의 3명, 5년 이상 근무한 방사선사 5명의 blind test를 통하여 영상을 평가해 보았다. IEC phantom에서 각 구별로 CT 감쇠보정 전후의 대조도 분석 결과 감쇠보정 전보다 최소 33.6%, 최대 89.8% 향상되었고, Jaszczak phantom의 경우 대조도가 최소 9.9%, 최대 27.8%, triple line phantom에서 수평의 경우 분해능이 4.4%, 수직의 경우 분해능이 4.6%로 평균 약 4.5%, anthropomorphic torso phantom의 경우 심근 하벽에서의 관류 점수가 29.4%로 향상된 것을 알 수 있었다. 그리고 환자를 대상으로 한 실험에서는 $^{131}I$, bone SPECT/CT의 blind test 결과 감쇠보정 후 영상의 질이 향상되었음을 알 수 있었다. CT 감쇠보정을 통한 SPECT/CT 영상의 질을 평가한 결과 SPECT 영상에서 대조도와 공간분해능이 향상됨을 알 수 있었다. 따라서 CT를 이용한 감쇠보정은 병소의 해부학적 위치를 정확히 검출할 수 있고, 보다 나은 영상을 기대할 수 있을 것으로 사료된다.

  • PDF

심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발 (Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT)

  • 야마모토토모아키;김정민;이기성;타카야마테루히코;키타하라타다시
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.389-399
    • /
    • 2008
  • 단일광자방출컴퓨터단층촬영(SPECT) 시 정확도의 개선을 위하여 산란과 감약의 보정, 분해능의 개선이 매우 중요하다. 특히 호흡이나 맥동에 대한 심장의 움직임은 보정 에러의 원인이 된다. 심장 팬텀이 보정방법에 대한 검증을 위해 사용되고 있으나, 현재 사용 중인 팬텀들은 실제 인체 데이터와 다른 점이 많이 나타나고 있다. 즉 팬텀을 사용한 결과는 임상데이터와 같게 취급할 수가 없다. 저자들은 흉곽의 인체 구조와 같은 신뢰성 있는 새로운 팬텀을 개발하였다. 새로운 팬텀은 폐와 심장의 전면, 측면 및 상부가 접하는 작은 종격구조를 가지고 있다. 용기는 아크릴로 만들었으며 종격은 물 등가물질을 사용하여 제조하였다. 폐는 에폭시레진의 고형 폴리우레탄 폼을 사용하였다. 5가지 크기의 심장은 게이트 심근관류 SPECT의 정량적 분석을 위하여 개발되었다. 심장팬텀들의 종격은 같은 포지션에 위치할 수 있도록 고안되었다. 완성된 팬텀은 간과 담낭에 부착되고 각각 높이 조절이 가능하다. 5개의 심실의 용적은 각각 150.0, 137.3, 83.1, 42.7과 38.6ml이다. 새로운 팬톰을 사용하여 SPECT 검사를 시행하고 보정법을 적용한 후에 영상의 차이를 검토하였다. 심장의 3차원 단층상이 효율적으로 재구성 되었으며 여러 가지 보정방법의 차이를 나타내기 위하여 주관적 평가도 시행하였다. 저자들은 SPECT영상과 QGS(Quantitative Gated SPECT) 결과로서 보정방법의 차이를 나타낼 수 있는 새로운 팬텀을 개발하여 보고하는 바이다.

  • PDF

List Mode에서 PET/CT Scanner의 직선성 평가 (Linearity Estimation of PET/CT Scanner in List Mode Acquisition)

  • 최현준;김병진;이또 미키코;이홍재;김진의;김현주;이재성;이동수
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.86-90
    • /
    • 2012
  • Rb-82를 이용한 PET 검사는 심근 관류의 임상적 평가에 중요한 역할을 한다고 알려져 있다. 그러나 PET/CT의 dead time 때문에 count value와 방사능농도 사이의 직선성이 유지되지 않는다면 데이터를 획득할 때 좌심실 입력 함수가 과대평가되어 심근관류가 과대평가될 수 있다. 본 연구에서는 리스트 모드에서 획득한 PET data에서 방사능농도에 따른 count value의 직선성을 평가하였다. Biograph 40 True Point PET/CT를 이용하여 직경 12 cm, 길이 10.5 cm의 cylindrical phantom에 F-18 333 MBq과 물 800 mL를 채우고 7반감기동안 10min frame/bed로 리스트 모드를 이용하여 획득하였다. Raw data는 OSEM (order: 4, subsets: 8)과 FBP (Gaussian filter FWHM 5 mm) 알고리즘을 이용하여 재구성하였다. Sinogram 정보에서 prompt counts, net true counts, random counts를 측정하였다. 재구성 된 phantom 영상에 ROI를 설정하여 총 계수와 background를 측정하고 background correction을 사용하여 count value를 측정하여 직선성을 평가하였다. 리스트 모드를 이용하여 sinogram에서 측정된 prompt counts는 방사능농도에 비례하여 증가하였다. 낮은 방사능농도에서 net true counts와 random counts는 방사능농도에 따라 증가하였다. 높은 방사능농도에서는 net true counts의 증가율이 점차 감소되었고, 반면에 random counts의 증가율은 증가하였다. 그리고 OSEM과 FBP 알고리즘으로 재구성된 영상에서 측정한 count value의 차이는 없었고 방사능농도에 비례하여 count value가 증가하고 직선성이 유지되었다. Biograph 40 True Point PET/CT scanner는 재구성된 영상에서 낮은 방사능농도뿐만 아니라 높은 방사능농도(~416.25 kBq/mL)에서도 측정 된 count value와 방사능농도 사이의 직선성이 유지되는 것을 보여주었다. 따라서 실험에서 사용한 PET/CT scanner는 Rb-82, N-13, O-15, F-18을 이용한 heart dynamic PET study에서데이터의 정량적 분석에 유용할 것으로 판단된다.

  • PDF

선천성심질환(先天性心疾患)의 심폐기(心肺器) 개심수술(開心手術) - 4례(例) 보고(報告) - (Open Heart Surgery of Congenital Heart Diseases -Report of Four Cases-)

  • 김근호;박영관;지행옥;김영태;이종배;정윤채;오철수
    • Journal of Chest Surgery
    • /
    • 제9권1호
    • /
    • pp.1-9
    • /
    • 1976
  • The present. study reports four cases of congenital heart diseases, who received open heart surgery by the Sarn's Heart-Lung-Machine in the department of Thoracic Surgery, Hanyang University Hospital during the period between July 1975 and May 1976. The Heart-Lung-Machine consisted of the Sarn's five head roller pump motor system (model 5000), heat exchanger, bubble trap, the Rygg-Kyvsgaard oxygenator, and monitors. The priming of pump oxygenator was carried out by the hemodilution method using Hartman's solution and whole blood. Of the four cases of the heart diseases, three whose body weight were below 30kg, received the partial hemodilution priming and the remaining one whose body weight was 52kg received the total hemodilution priming with Hartman's solution alone. The rate of hemodilution was in the average of 60.5ml/kg. Extracorporeal circulation was performed at the perfusion flow rate of the average 94.0ml/kg/min, and at the moderate hypothermia between 35'5"C and 30'5"C of the rectal temperature. In the total cardiopulmonary bypass, arterial blood pressure was anged between 30 mmHg and 85 mmHg, generally maintaining over 60 mmHg and venous pressure was measured between 4 and $23cmH_2O$, generally maintaining below $10cmH_2O$. The first case: The patient, a nine year old girl having the symptoms and physical signs typical to cardiac anomaly was definitely diagnosed as isolated pulmonary stenosis through the cardiac catheterization. There was, however, no cyanosis, no pathological finding by X-ray and E.C.G. tracings. The valvulotomy was performed through the arteriotomy of pulmouary artery under the total cardiopulmonary bypass. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The second case: A 12 year old boy with congenital heart anomaly was positively identified as having ventricular septal defect through the cardiac catheterization. As in the case with the first case, the patient exhibited the symptoms and physical signs typical to cardiac anomaly, but no pathological abnormality by X-ray and E.C.G. tracings. The septal defect was localized on atrioventricular canal and was 2 by 10 mm in size. The septal defect was closed by direct simple sutures under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle and pulmonary artery were decreased satisfactory. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The third case: The patient, a 19 year old girl had been experienced the clinical symptoms typical to cardiac anomaly for 16 years. The pink tetralogy of Fallot was definitey diagnosed through the cardiac catheterization. The patient was placed on an ablolute bed rest prior to the operation because of severe exertional dyspnea, fatigability, and frequent syncopal attacks. However, she exhibited very slight cyanosis. Positive findings were noted on E.C.G. tracings and blood picture, but no evidence of pathological abnormality on X-ray was observed. All of the four surgical approaches such as Teflon patch closure (3 by 4cm in size) of ventricular septal defect, myocardial resection of right ventricular outflow tract, valvulotomy of pulmonary valvular stenosis, and pericardial patch closing of ventriculotomy wound were performed in 95 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The fourth case: The patient, a 7 1/4 year old girl had the symptoms of cardiac anomaly for only three years prior to the operation. She was positively identified as having acyanotic tetralogy of Fallot by open heart surgery. The patient showed positive findings by X-ray and E.C.G. tracings, but exhibited no cyanosis and normal blood picture. All of the three surgical approaches, such a myocardial resection of hypertrophic sight ventricular outflow tract, direct suture closing of ventricular septal defect and pericardial patch closing of ventriculotomy wound were carried out in 110 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and the symptoms disappeared.

  • PDF

니트로글리세린 투여 Tc-99m-MIBI 정량 게이트 심근SPECT를 이용한 관상동맥우회로술 후 심근 기능 회복 예측 (Nitroglycerin-Challenged Tc-99m MIBI Quantitative Gated SPECT to Predict Functional Recovery After Coronary Artery Bypass Surgery)

  • 이동수;김유경;천기정;팽진철;이명묵;김기봉;정준기;이명철
    • 대한핵의학회지
    • /
    • 제37권5호
    • /
    • pp.278-287
    • /
    • 2003
  • 목적: 생존심근 진단에 있어 니트로글리세린 투여 Tc-99m-MIBI 게이트 심근SPECT의 진단성능을 휴식/지연재분포 Tl-201 심근SPECT와 비교하였다. 대상 및 방법: 22명의 관상동맥질환자에서 Tl-201 휴식/디피리다몰 부하 Tc-99m-MIBI 게이트 지연재분포 Tl-201 심근SPECT를 시행하였다. 이 때 게이트SPECT 시행 후 니트로글리세린 0.6 mg을 설하투여하고 연이어 그 자리에서 게이트SPECT를 1회 더 반복 시행하였다. 환자들에게 관상동맥우회로술을 시행하고 3개월 후 게이트 심근SPECT를 추적검사로 시행하였다. 20 분절 모델을 이용하여 각 분절에서 휴식, 지연재분포, 기저상태와 니트로글리세린투여 후의 심벽운동 및 수축기비후화 등을 정량하였다. 정량화된 생존심근 예측지표들 중, (1) 휴식기 Tl-201 섭취, (2) Tl-201 지연재분포, (3) 기저상태의 수축기비후화, (4) 니트로글리세린 투여 후의 수축 기비후화, 네 가지의 예측성능을 평가하고 비교하였다. 결과: 총 100개의 분절이 분석에 포함되었으며, 이 중 66개(66%)의 분절이 재관류 후 기능 회복을 보였다. 최적 기준점인 50%를 기준으로 하였을 때, ROC 곡선 분석에서 휴식기 Tl-201 섭취와 Tl-201 지연재분포의 민감도, 특이도는 각각 79%와 44%, 그리고 82%와 44%였다. 또한 15%를 기준으로 하여, 기저상태 수축기비후화와 니트로글리세린 투여 후 수축기비후화의 민감도, 특이도는, 각각 49%, 50%와 64%, 65%였다. ROC 곡선의 AUC는 니트로 글리세린 투여 후 수축기비후화가 기저시 수축기비후화에 비하여 유의하게 높았다(p=0.004). 결론: 니트로글리세린 투여 Tc-99m-MIBI 정량적 게이트 심근SPECT는 기능이상 심근에서 기능 회복을 예측하는데 유용한 검사이다.

폐의 양성 및 악성 병변에서 $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT의 진단적 가치 (Usefulness of $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT in Benign and Malignant Lesion of the Lungs)

  • 김성숙;김기범;조영복;조인호;이경희;정진홍;이형우;이관호;이현우;김미진
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권1호
    • /
    • pp.54-62
    • /
    • 1996
  • 연구배경: $^{99m}Tc$ MIBI은 지용성 양이온으로 심근혈류에 따라 심근에 섭취되는 방사성 동위원소로써 Thallium-201과 함께 성근 관류 스캔에 사용되어 왔다. Thallium-201이 암세포에도 섭취된다는 것은 이미 잘 알려져 있으며, 최근 $^{99m}Tc$ MIBI도 심근 세포이외에 폐와 종격동의 암세포에도 섭취된다는 보고가 있다. 저지들은 $^{99m}Tc$ MIBI가 폐암의 진단이나 암세포의 임파절의 전이 유무의 확인에 어느 정도 효과적으로 사용될 수 있는지 알아보고자 하며 동시에 폐렴이나 폐결핵 등과 같은 양성 폐질환과의 감별진단에도 효과적으로 사용될 수 있을지에 관하여 알아보았다. 방법: 대상은 영남대학교 의과대학 부속병원 내과에서 원발성 폐암으로 확진된 환자 34예와 조직 검사나 객담 검사를 통하여 양성 폐질환으로 진단된 10예의 환자를 대상으로 하였다. 대상환자 모두에서 $^{99m}Tc$ MIBI lung SPECT를 시행하였으며 비슷한 시기에 시행한 흉부 단층 촬영소견과 비교하였다. $^{99m}Tc$ MIBI SPECT는 먼저 특별한 전처치없이 $^{99m}Tc$ MIBI 740MBq(20mCi)을 정맥 주사하고, 한시간 후에 고해상력 조준기를 장착한 회전 감마카메라(Prism-2000, Picker)를 이용하여 360도 회전시키면서 45개의 투사 영상을 얻었다. 각 영상은 감마 카메라에 연결된 컴퓨터에 수록되었고 Metz filter을 이용하여 여과후 역투사를 시행하였고 횡단면, 시상(矢狀, saggital)면과 coronal view를 얻었다. 각 상에서 폐암 병소, 심장 그리고 정상적인 폐 부위의 방사능을 측정하여 정상 폐에 대한 폐 병소의 섭취율(lung lesion/normal area; HT/NL), 정상 폐에 대한 심장의 섭취율(heart/normal area; HT/NL) 및 폐병소에 대한 심장의 섭취율(heart/lung lesion; HT/TR) 등의 비를 구하여 각 단면상에서의 $^{99m}Tc$ MIBI 섭취율을 비교하였다. 곁과: 원발성 폐암 34예 오해서 암병소에 $^{99m}Tc$ MIBI의 섭취가 증가되었으며 종격동 및 기관지 주변 임파절 전이부위에도 섭취가 증가되었다. 원발성 폐암과 양성 폐질환에서 병소와 정상 폐간의 섭취율의 각각 $3.79{\pm}1.82$, $1.67{\pm}0.63$로 두군간에 유의한 차이가 있었다(p<0.001). 원발성 폐암의 경우 각 조직형에 따른 병소와 정상 폐간의 섭취율의 비는 편평 상피 세포암의 경우 $3.64{\pm}1.66$, 소세포암의 경우 $3.57{\pm}0.72$, 선암의 경우 $4.31{\pm}2.28$로써 각 조직형에 따른 통계적인 차이는 없었다. 결론: $^{99m}Tc$ MIBI lung SPECT는 원발성 폐암의 진단 및 임파절 전이의 유무 확인은 물론 양성 폐질환과의 감별진단에도 도움이 될 것으로 생각된다.

  • PDF

게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구 (Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography)

  • 정지욱;이효영;윤종준;이화진;이무석;송현석;박세윤;김재환
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.150-154
    • /
    • 2010
  • 심장기능을 평가하는데 중요한 기준이 되는 심박출계수의 측정은 반복검사가 용이한 심초음파가 가장 흔히 사용되고 있다. 현재 게이트심장혈액풀스캔의 검사 빈도가 낮고 게이트심장혈액풀 SPECT를 이용한 좌심실 심박출계수의 결과는 게이트심장혈액풀스캔과 심초음파의 결과와 비교적 잘 맞는 것으로 알려져 있으나 임상적으로는 잘 이용되지 못하고 있다. 이에 본 연구에서는 게이트심장혈액풀스캔 및 SPECT에서의 심박출계수를 심초음파와 비교하여 분석하였다. 2007년 1월부터 2010년 5월까지 34명의 환자를 대상으로 심초음파 검사 후 게이트심장혈액풀스캔과 SPECT를 함께 시행하였다. 대상 환자 가운데 남자가 23명이었고 여자는 11명이었으며 평균연령은 $52.6{\pm}27.2$세였다. 환자에게 생리식염수로 희석한 pyrophosphate 1 cc를 먼저 정맥주사하고 15분 후 20 mCi의 $^{99m}{TcO_4}^-$를 정맥주사 하였다. 10분 후 안정 상태에서 심전도를 부착한 뒤 planar와 SPECT를 연속하여 촬영하고 ADAC Laboratories, Ver. 4.20 software를 이용하여 영상을 분석하고 각각의 심박출계수를 측정하였다. 일원배치 분산분석(one-way anova) 후 사후검정(Tukey test)을 통해 평균값을 비교하고 서로 간 pearson 상관계수를 구하였다(SPSS Ver 17.0). 심박출계수의 평균값과 표준편차값은 planar에서 $56.3{\pm}13.9$ (%), SPECT에서 $60.4{\pm}16.0$ (%), 심초음파에서는 $59.1{\pm}14.4$ (%)로 유의한 차이는 없었으며(p=0.486) 이에 대한 사후 검정은 planar-심초음파 p=0.697, SPECT-심초음파 p=0.928, planar-SPECT p=0.469로 유의한 차이가 없었다. 상관관계에서는 planar-심초음파 r=0.801, SPECT-심초음파 r=0.810, planar-SPECT r=0.873 비교적 높은 상관관계를 보였다(p<0.01). 게이트혈액풀스캔 및 SPECT와 심초음파를 이용하여 구한 좌심실의 심박출계수는 높은 상관성을 보였으며 평균값에서도 유의한 차이는 없었다. 현재 게이트혈액풀스캔은 시행건수가 줄어들고 스캔의 정확성이나 재현성에 대한 문제는 남아있으며 SPECT의 경우 임상적으로 잘 적용되지 못하고 있으나 다양한 심기능 지표들을 얻을 수 있고 혈액풀스캔에서의 심박출계수와 좋은 일치율을 보이므로 심초음파를 대체할 수 있는 유용한 검사법이라 생각된다.

  • PDF

전기 유압식 심실보조장치의 동물실험 연구 (An Animal Study on Electrohydraulic Type Ventricular Assist Device)

  • 백완기;심상석
    • Journal of Chest Surgery
    • /
    • 제29권7호
    • /
    • pp.689-699
    • /
    • 1996
  • 신개발한 전기 유압식 심실 보조장치의 생 체 내 성능 테스트와 상기 심실보조장치를 이용한 좌심실 보 조가 자연심장 좌심실의 기능에 미치는 영향을 평가하기 위한 동물실험을 고안하였다. 총 성숙 면양 8마리가 실험에 사용되었으며 이중 7마리로부터 자료 수집이 가능하였다. 심실 보조시 간은69분부터 7일 사이로 심실보조장치는 자연심장의 박동수범위 내에서 동기식 및 비동기식 방식 모 두 만족스럽게 작동하였으며, 좌심방 내의 음압의 발생 없이 주어진 정상 좌심방압 내에서 분당 4리터 이상의 보조 혈류량을 얻을 수 있었다. 심실보조 개시 3일 이후부터 혈중 유리혈색소의 급격한 증가를 보여 상당량의 용혈이 진행되고 있음 을 시사하였다. 또한 심실보조 후 혈액 남의 부동형 고분자판막(floating type polymer valve)에 소량의 혈 전이 발견되어 혈액적 합성 및 혈전저항성 면에 있어 보다 많은 연구 및 개선의 여지가 있음을시사하였 다. 심실보조시작후의 혈역학의 변화는혈류보조량분당2.0∼2.5리터 사이에서 자연심장의 박동수및 박출량과 좌심실 분당작업량(left ventricular minute work), 심내막 생육력비 (endocardial viability ratio), 흔합 정맥혈 및 관상동맥 정맥혈 산소량은 증가하는 소견을 보였으며,반대로 좌심실압 및 좌심방압과 좌심실압 변화율(left ventricular dp/dt)은 감소하는 소견을 보였다. 이중 심박출량의 변화 외에는 모두 통계적으로 유의한 차이를 보여 효과적 인 좌심실의 탈부하가 이루어지고 있음을 입증하였다. 또한 동기식 심실보조시 심내막 생육력비 및 관상정맥혈의 산소량은 비동기식 심실보조시와 비교할 때 역시 통계적으로 유의한 차이를 보여 동기식 심실보조에 의한 반박동(counterpulsation)이 심근의 관 류량을 증가시키며 따라서 손상된 심근의 회복에 유리 함을 시사하였다.

  • PDF