• Title/Summary/Keyword: Myocardial perfusion

Search Result 274, Processing Time 0.029 seconds

Current Trends and Future Development in Pharmacologic Stress Testing (약물부하 검사법의 현재와 미래)

  • Bae, Jin-Ho;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.107-113
    • /
    • 2005
  • Pharmacologic stress testing for myocardial perfusion imaging is a widely used noninvasive method for the evaluation of known or suspected coronary artery disease. The use of exercise for cardiac stress has been practiced for over 60 years and clinicians are familial with its using. However, there are inevitabe situations in which exorcise stress is inappropriate. A large number of patients with cardiac problems are unable to exercise to their full potential due to comorbidity such as osteoarthritis, vascular disease and pulmonary disease and a standard exercise stress test for myocardial perfusion imaging is suboptimal means for assessment of coronary artery disease. This problem has led to the development of the pharmacologic stress test and to a great increase in its popularity. All of the currently used pharmacologic agents have well-documented diagnostic value. This review deals the physiological actions, clinical protocols, safety, nuclear imaging applications of currently available stress agents and future development of new vasodilating agents.

Effect of Topical Hypothermia on Myocardial Protection from Ischemia - Experimental study using isolated rat heart perfusion technique- (흰쥐의 적출된 작업성 심장에서 허혈성 심정지시 국소냉각법이 심근보호에 미치는 영향)

  • 최종범
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.231-239
    • /
    • 1988
  • Currently numerous methods are in use for myocardial hypothermia as a myocardial preservation modality for cardiac operation. During cardiac ischemia after crystalloid cardioplegia[4C GIK solution], topical cold saline[Group I, a=9], topical ice slush[Group II, n=9] and topical ice chip[Group III, a=10] have been compared for myocardial surface cooling in the isolated rat heart model of cardiopulmonary bypass. During postischemic period, hemodynamic functions[aortic flow, coronary flow, peak aortic pressure and heart rate], biochemical enzymatic activities and cellular injuries with electron microscope were evaluated in this isolated rat heart perfusion model. Postischemic aortic flow, cardiac output and peak aortic pressure in Group I and Group II recovered better than Group III.[p< 0.05] Postischemic creatine kinase and lactate dehydrogenase leakages in Group II and Group III increased more than Group l and postischemic mitochondrial swelling in Group III was more severe than Group I, and Group II.[p< 0.05] These results suggest that topical cold saline was the better method than topical ice slush or topical ice chip as a myocardial preservation modality in the isolated rat heart model of cardiopulmonary bypass.

  • PDF

A Comparison of the Efficacy of Antegrade Cardioplegia Versus Retrograde Right Atrial Cardioplegia for Myocardial Protection During Open Heart Surgery (개심술시 심근보호를 위한 순행성 관관류법과 역행성 관관류법의 비교를 한 실험적 연구)

  • 유시원
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.17-25
    • /
    • 1988
  • This study was undertaken to evaluate the efficacies for myocardial protective effect of retrograde right atrial perfusion [RRAP] of cardioplegia compared with antegrade aortic root perfusion [AARP]. Myocardial distribution of perfusate [using methylene blue] with RRAP was less poor to AARP. Myocardial protective effect was estimated with myocardial temperature and electron microscopy. Cooling protection of right ventricle with RRAP was similar to AARP. On the other hand, cooling protection of left ventricle with RRAP was slight poor to AARP. The electron microscopic ischemic change of right and left ventricle with RRAP was similar to AARP. RRAP was thought to be a good alternative method to perfuse cardioplegia and protect both ventricle.

  • PDF

CT Fractional Flow Reserve for the Diagnosis of Myocardial Bridging-Related Ischemia: A Study Using Dynamic CT Myocardial Perfusion Imaging as a Reference Standard

  • Yarong Yu;Lihua Yu;Xu Dai;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.1964-1973
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of CT fractional flow reserve (CT-FFR) for myocardial bridging-related ischemia using dynamic CT myocardial perfusion imaging (CT-MPI) as a reference standard. Materials and Methods: Dynamic CT-MPI and coronary CT angiography (CCTA) data obtained from 498 symptomatic patients were retrospectively reviewed. Seventy-five patients (mean age ± standard deviation, 62.7 ± 13.2 years; 48 males) who showed myocardial bridging in the left anterior descending artery without concomitant obstructive stenosis on the imaging were included. The change in CT-FFR across myocardial bridging (ΔCT-FFR, defined as the difference in CT-FFR values between the proximal and distal ends of the myocardial bridging) in different cardiac phases, as well as other anatomical parameters, were measured to evaluate their performance for diagnosing myocardial bridging-related myocardial ischemia using dynamic CT-MPI as the reference standard (myocardial blood flow < 100 mL/100 mL/min or myocardial blood flow ratio ≤ 0.8). Results: ΔCT-FFRsystolic (ΔCT-FFR calculated in the best systolic phase) was higher in patients with vs. without myocardial bridging-related myocardial ischemia (median [interquartile range], 0.12 [0.08-0.17] vs. 0.04 [0.01-0.07], p < 0.001), while CT-FFRsystolic (CT-FFR distal to the myocardial bridging calculated in the best systolic phase) was lower (0.85 [0.81-0.89] vs. 0.91 [0.88-0.96], p = 0.043). In contrast, ΔCT-FFRdiastolic (ΔCT-FFR calculated in the best diastolic phase) and CT-FFRdiastolic (CT-FFR distal to the myocardial bridging calculated in the best diastolic phase) did not differ significantly. Receiver operating characteristic curve analysis showed that ΔCT-FFRsystolic had largest area under the curve (0.822; 95% confidence interval, 0.717-0.901) for identifying myocardial bridging-related ischemia. ΔCT-FFRsystolic had the highest sensitivity (91.7%) and negative predictive value (NPV) (97.8%). ΔCT-FFRdiastolic had the highest specificity (85.7%) for diagnosing myocardial bridging-related ischemia. The positive predictive values of all CT-related parameters were low. Conclusion: ΔCT-FFRsystolic reliably excluded myocardial bridging-related ischemia with high sensitivity and NPV. Myocardial bridging showing positive CT-FFR results requires further evaluation.

Characteristic Findings of Exercise ECG Test, Perfusion SPECT and Coronary Angiography in Patients with Exercise Induced Myocardial Stunning (게이트 심근관류 SPECT상 운동 유발성 기절심근을 보이는 환자의 운동부하 심전도, 관류 SPECT 및 심혈관 조영술 소견)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyoung;Bae, Jin-Ho;Jeong, Shin-Young;Park, Hun-Sik;Lee, Jae-Tae;Chae, Shung-Chul;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.225-232
    • /
    • 2004
  • Purpose : Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Materials and Methods : Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV election fraction (LVEF) was $\geq5%$ lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1 %(non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Results : Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs. 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs. 9.2%, p=0.029; severity 13.5 vs. 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis ($80{\sim}99%$) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Conclusion : Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than patients without post-stress LV dysfunction. All of the patients without perfusion defect in stunning group had significant coronary artery stenosis and needed revascularization. Therefore, we suggest that invasive diagnostic procedures and therapeutic interventions might be needed in patients with post-stress LV dysfunction.

Functional Significance of Angiographic Collaterals in Patients with Totally Occluded Right Coronary Artery: Intracoronary Thallium-201 Scintigraphy (우측 관상동맥 폐쇄 환자에서 관상동맥내 Thallium-201 주사를 이용한 측부 혈행의 의의)

  • Lee, Do-Yun;Lee, Jong-Doo;Cho, Seung-Yun;Shim, Won-Heum;Ha, Jong-Won;Kim, Han-Soo;Kwon, Hyuk-Moon;Jang, Yang-Soo;Chung, Nam-Sik;Kim, Sung-Soon;Park, Chang-Yun;Kim, Young-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.210-217
    • /
    • 1993
  • To compare the myocardial viability in patients suffering from total occlusion of the right coronry artery (RCA) with the angiographic collaterals, intracoronary injection of Thallium-201 (T1-201) was done to 14 coronary artery disease (CAD) patients (pts) with total occlusion of RCA and into four normal subjects for control. All 14 CAD pts had Grade 2 or 3 collateral circulations. There were 14 male and 4 females, and their ages ranged from 31 to 70 years. In nine pts, T1-201 was injected into left main coronary artery (LCA) ($300{\sim}350{\mu}Ci$) to evaluate the myocardial viability of RCA territory through collateral circulations. The remaining five pts received T1-201 into RCA ($200{\sim}250{\mu}Ci$) because two had intraarterial bridging collaterals and three had previous successful PTCA. Planar & SPECT myocardial perfusion images were obtained 30 minutes, and four to five hours after T1-201 injection. Intravenous T1-201 reinjection (six pts) or $^{99m}Tc-MIBI$ (two pts) were also performed in eight CAD pts. Intracoronary myocardial perfusion images were compared with intravenous T1-201 (IV T1-201) images, ECG, and ventriculography. Intracoronary T1-201 images proved to be superior to that of IV T1-201 due to better myocardial to background uptake ratio and more effective in the detection of viable tissue. We also found that perfusion defects were smaller on intracoronary T1-201 images than those on the IV T1-201. All of the 14 CAD pts had either mostly viable myocardium (seven pts) or large area of T1-201 perfusion (seven pts) in RCA territory, however ventriculographic wall motion and ECG did not correlate well with intracoronary myocardial perfusion images. In conclusion, total RCA occlusion patients with well developed collateral circulation had large area of viable myocardial in the corresponding territory.

  • PDF

Comparison Study between Myocardial Velocity obtained from Gated Myocardial SPECT and Myocardial Functional indices with a Focus on Myocardial Perfusion (게이트 심근 관류 SPECT에서 구한 심근 속도와 심근 관류를 중심으로 한 심근 기능 지표와의 비교연구)

  • Ha, Jung-Min;Jeong, Shin-Young;Bom, Hee-Seung;Lee, Byeong-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.386-394
    • /
    • 2009
  • Purpose: We aimed to assess the myocardial velocity on gated myocardial perfusion SPECT (gated MPS), to compare myocardial velocity between patients without coronary artery disease (CAD) and CAD patients and to assess the correlation of myocardial velocity and perfusion and wall thickening on CAD group. Materials and Methods: Seventeen patients without CAD (M:F=9:8, mean age $61.8{\pm}11.1$ yrs: group A) and thirty-nine patients with CAD (M:F=18:21, mean age $66.9{\pm}8.1$ yrs : group B) had undergone one-day adenosine stress gated MPS. In twenty segment model, 12 segments (except apical and basal segments) of each patient were included. We obtained systolic and diastolic gate ratio in left ventricular volume curve by eight frames per cardiac cycle on gated MPS. Using the systolic and diastolic gate ratio and R-R time of each patient, we obtained systolic and diastolic time ratio. The myocardial velocity was defined as wall thickening over systolic or diastolic time. Results: We presented normal range of myocardial velocities according segments and territories of coronary artery. The myocardial velocity of group B was significantly lower than group A (p=0.00). There was no significant difference between the myocardial velocity of group B with preserved EF and group A. The stress systolic velocity significantly correlated with regional myocardial perfusion in group B with preserved EF (p=0.00) as well as decreased EF (p=0.01). In group B, stress perfusion of segments which had decreased wall thickening and decreased myocardial velocity was significantly lower than segments which had decreased wall thickening and preserved myocardial velocity (p=0.01). Conclusion: The new functional index of velocity will be used as an useful of gated MPS.

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

The Correlation Analysis of Stress/Rest Ejection Fraction of $^{201}Tl$ Gated Myocardial Perfusion SPECT ($^{201}Tl$ 게이트 심근관류 스펙트에서의 휴식기와 부하기 좌심실 구혈률 상관관계 분석)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Shim, Dong-Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.3-9
    • /
    • 2009
  • Purpose: It is well-known that stress-induced stunning and reversible perfusion defect have impact on ejection fraction (EF) when performing myocardial perfusion SPECT. Due to these reasons, gated SPECT is recommended at stress and rest studies. And there was many experiments to analyze between Stress and Rest EF by using $^{99m}Tc$-MIBI. The aim of this study is to analyze between stress EF and rest EF at myocardial perfusion SPECT by using $^{201}Tl$ and define possible predictors of EF variability. Materials and Methods: From 2008 June to 2009 February, we analyzed 144 patients undergoing $^{201}Tl$ gated myocardial perfusion SPECT in ASAN medical center. To analyze the data, we use QGS (Quantitative gated SPECT) software, and derived End-systolic volume (ESV), End-diastolic volume (EDV), EF from the result. In this study, we comparatively analyzed stress/rest EF correlation based on stress/rest EF, EDV, ESV and reversibility of myocardial perfusion defect by using paired t-test, Bland-Altman analysis. Results: Mached pairs of stress EF and rest EF demonstrated excellent correlation (r=0.92) with no statistically significant difference (p=0.11). Bland-Altman analysis demonstrated a mean ${\Delta}EF$ was 0.52% (95% confidential interval[CI], -1.17~0.12%). No statistically significant difference between a mean ${\Delta}EF$ and hypothetic mean of 0 (${\Delta}EF$=0) (p=0.10). In the correlation of ${\Delta}EF$ according to stress/rest EDV and ESV, except rest ESV of <28mL (p<0.05), there was no statistically significant difference. In the correlation of ${\Delta}EF$ according to reversibility of perfusion defect, patients with reversible perfusion defect has statistically significant difference of ${\Delta}EF$ (p<0.05). ${\Delta}EF$ of stress/rest EF showed no statistically significant difference except 55% of rest EF (p<0.05). Conclusion: Like studies with $^{99m}Tc$-MIBI, there was generally no statistically significant difference between stress and rest EF in this study results. However a stress EF of <55%, a rest ESV of <28mL and patients with reversible perfusion defect showed statistically significant difference in ${\Delta}EF$. If performing $^{201}T$ myocardial perfusion SPECT to patients with abnormal cardiac function or reversible perfusion defect, consider this study results and apply it. We expect this study results could be useful predictors of ${\Delta}EF$ variability.

  • PDF

The Correlation Analysis of Ejection Fraction: Comparison of $^{201}Tl$ gated Myocardial Perfusion SPECT and Echocardiography ($^{201}Tl$ 게이트 심근관류 SPECT 및 심초음파의 좌심실 구혈률 상관관계 비교)

  • Yoon, Soon Sang;Ryu, Jae Kwang;Cha, Min Kyung;Lee, Jong Hun;Kim, Sung Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose : Gated myocardial perfusion SPECT provides not only myocardial perfusion status, but various functional parameters of left ventricle (LV). The purpose of this study was to analyze ejection fraction (EF) for correlation and difference between $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography depending on extent of perfusion defect, gender and LV volumes. Materials and Methods : From April 2011 to May 2012, we analyzed 291 patients (male:female =165:126; mean: $64.6{\pm}10.8$ years) who were examined both $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography at less than 7 days apart in our hospital. 101 patients showed perfusion defect and the rest of the people without any defect. We applied automatic analysis (Quantitative gated SPECT, QGS), and calculated EF, End-diastolic volume (EDV) and End-systolic volume (ESV) from Stress (G-Stress) and Rest (G-Rest) studies. And we analyzed the correlation and difference for EF between $^{201}Tl$ gated SPECT and echocardiography. Results : The correlation of LVEF among G-Stress, G-Rest and echocardiography was quite a good (G-Stress vs. G-Rest: r=0.909, G-Stress vs. echocardiography: r=0.833, G-Rest vs. echocardiography: r=0.825). And there were significant differences in EDV, ESV and EF in total patients (p<0.01). The normal group showed significant difference in EF (p<0.01) and the group with perfusion defect also demonstrated significant difference (a group with reversible defect: p<0.01, fixed defect: p<0.01) depending on extent of perfusion defect. We analyzed difference in normal group by gender. In normal group, there was no significant difference (p>0.05) in EF from men. However, there was a significant difference (p<0.01) from women. When we classified two groups by average size of EDV in Korean women, there was no significant difference in a group of above average size of EDV (p>0.05). Conclusion : When compared among Stress and Rest of $^{201}Tl$ gated SPECT and echocardiography, we confirmed that there was a good correlation for LVEF. But there were significant differences among three studies. And extent of perfusion defect, gender and LV volumes are independent determinants of the accuracy of LVEF. So, it is hard to compare and interchange quantitative indices among modalities. We should take additional researches to prove results of our study.

  • PDF