• Title/Summary/Keyword: Mushim-cheon

Search Result 5, Processing Time 0.017 seconds

Estimation of Suspended Sediment Runoff for Landuse (토지이용에 따른 부유토사 유출 평가)

  • Kim, Joo-Hun;Oh, Deuk-Kun;Kim, Kyung-Tak
    • Journal of Wetlands Research
    • /
    • v.7 no.1
    • /
    • pp.119-128
    • /
    • 2005
  • Sediment yield and sediment transport in a basin bring about decrease of conveyance by the change of bed section, and have an influence on an aggravation of water quality and freshwater ecosystem. This study is to analyze the characteristics of outflow sediment according to land-use in Mushim-cheon flowing through forest area, farmland area and urban area. The upper stream of Mushim-cheon consists of forest area and farmland area. The suspended sediment is observed through 10 rainfall events in 5 sites. As a result of analyzing characteristics of landuse, the site of Bangse-gyo takes up 69% of Mushim-cheon, and farmland area(27.1%) and forest area(63.7%) take up 90.8% in Bangse-gyo. Accordingly, these two areas have the high possibility to occur sediment. The suspended sediment of this site shows the highest concentration. Transferring to the downstream and the urban, the concentration of suspended sediment gets decreased. The suspended sediment occurred in the upper stream of Mushim-cheon prior to Bangse-gyo has an influence on the downstream, and has a slight influence on the urban area. Also relational formula about suspended sediemtn and discharge is leaded. As a result of this formula, $R^{2}$ is 0.506 in the upper stream and is 0.656 in the downstream.

  • PDF

Estimation of Flow Loads for Landcover Using HyGIS-SWAT (HyGIS-SWAT을 이용한 토지피복도에 따른 유출부하 평가)

  • Kim, Joo-Hun;Kim, Kyung-Tak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.2
    • /
    • pp.28-39
    • /
    • 2011
  • This study estimates the characteristics of flow loads by classification items of the Ministry of Environment and by land cover change using HyGIS-SWAT. The result of analyzing the land cover change using the classification items shows that the urban area and the farmland area in Mishim-cheon and Gap-cheon are expanding while the forest area is decreasing. The result of analyzing the characteristics of classification items shows that peak discharge increases and total yearly discharge decreases in Mushim-cheon. The result of analyzing the characteristics by data-construction period shows that peak discharge decreases but total discharge increases in Gap-cheon. Three land cover change scenarios are applicable to the expansion of urban area and farmland area. According to the result of application, urbanization influences and Farmland area expansion influences increase peak discharge, total yearly discharge and sediment concentration.

Contamination of the Mushim-Cheon and its Countermeasure;II. The Status of the Seasonal and Hourly Contamination of the Water(1989${\sim}$1990)-Temperature, pH, DO, BOD, COD, SS, Turbidity, and BOD Load (무심천(無心川) 수질(水質) 오염(汚染) 실태(實態)와 그 방지책(防止策);II. 계절별(季節別) 및 시간별(時間別) 현황(現況) (1989-1990)-수온, pH, DO, BOD, COD, SS, 탁도 및 BOD 부하량(負荷量))

  • Lee, Jae-Koo;Kim, Hak-Nam;Kyung, Kee-Sung;Kwak, Hee-In
    • Korean Journal of Environmental Agriculture
    • /
    • v.10 no.1
    • /
    • pp.33-49
    • /
    • 1991
  • In order to disclose the contamination of the Mushim-Cheon by pollutants and to establish the countermeasures, the water samples collected in November of 1989(lst sample), February(2nd), May(3rd) and August of 1990(4th) were analyzed to obtain the following results : 1. The water temperatures of the seasonal samples ranged from 8.6 to 16.2, 8.3 to 25.2, 18 to 26, and 24 to 32$^{\circ}C$, in the 1st, 2nd , 3rd, and 4th samples, respectively. 2. The pHs of all the samples ranged from 6.5 to 8.5. 3. In the 3rd sample, especially, DO was observed to fall down to 0.8 ppm at the downstream of St 13, which is not allowed even for agricultural use. 4. The BOD and COD values in sewers were much higher than those in the main stream, and especially the values of St 14-A reached 107-608 and 176-635 ppm, respectively, which far exceeded the limit of 40 ppm, the allowed value for the discharges from the disposal facilities. The SS value of St 14A ranged from 142 to 1, 900 ppm, which far exceeded the limit of 70 ppm, the allowed value for the discharges from the disposal facilities. 5. It turned out that the water quality of the Mushim-Cheon flowing through Cheong Ju was more worsened at sewers than the main stream, and at the downstream than the upstream of the surveyed area. Accordingly, the sewage disposal plant and the expansion of the disposal facilities are urgently needed.

  • PDF

Contamination of the Mushim-Cheon and its Countermeasures;I. Analysis of the Water Samples in Summer (무심천 수질 오염 실태와 그 방지책;I. 하계절의 수질 오염 분석)

  • Lee, Jea-Koo;Kyung, Kee-Sung;Kim, Hak-Nam;Oh, Kyeong-Seok
    • Korean Journal of Environmental Agriculture
    • /
    • v.9 no.1
    • /
    • pp.23-37
    • /
    • 1990
  • In order to disclose the contamination of the Mushim-Cheon by pollutants in August and September of 1989 and to establish countermeasures, the collected water samples were analyzed to obtain the following results : 1. The water temperature of the period ranged from 25.8 to $30.8^{\circ}C$ acceptable for the growth of microorganisms and algae to allow the self-purification of the stream. 2. The pHs at the sites during the same period ranged from 6.5 to 8.5 which fall within the allowed values for the first grade water supplies except for site 14. 3. At site 18 which is the confluence of the sewer of the excretion disposal facilities and the main stream, the DO was observed to fall down to 0.7 ppm in September. 4. The BOD value reached a maximum of 62.1 ppm at site 18, which far exceeded the limit of 40 ppm, the allowed value for the discharges from the disposal facilities. In addition, the SS values were 200 and 520 ppm in August and September, respectively, which were three to seven times as high as the allowed limit of 70 ppm. 5. The high $NH_3-N$ value of 46.2 ppm at site 18 in September suggested that the water was heavily contaminated with excretions. 6. The BOD load of the sewage from site 12, the Sajik-Dong Sewer, in September was estimated to be about 0.306 ton/day. 7. The contamination of the influents, the family wastewater, and the discharges from the disposal facilities was greater than that of the main stream. 8. In the samples collected from site 12, the Sajik-Dong sewer at an interval of every two hours, a close correlation was observed between the pollutant load and the life cycle of the nearby inhabitants. 9. Compared with the results obtained from the water samples in 1979, it was observed that the water was heavily contaminated at site 12 (the Sajik-Dong Sewer, under the Chung Ju Great Bridge) and site 15 (Under the 2nd Uncheon Bridge) over the last 10 years, with little difference at site 9(Young Un-Dong water supply source).

  • PDF

Estimation of Flow Loads Characteristics each Sub-watershed for TMDL (TMDL 적용을 위한 소유역별 유출부하 특성 분석)

  • Kim, Joo-Hun;Kim, Kyung-Tak;Lee, Jin-Won
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.443-453
    • /
    • 2011
  • This research aims at suggesting the mitigation measures of decreasing pollution by analyzing land cover characteristics according to subwatershed, and non-pollutant load characteristics occurring in each subwatershed. Mushim-cheon is selected as a research area, and HyGIS-SWAT is used as a water quality model. This research analyzed outflow load characteristics by classifying land cover, which has over 50% classified items, into a city area, a farmland area and a forest area. The result shows that the yearly occurrence load quantity represents a farmland area, a forest area and a city area in order. In subwatershed-2, occurrence load quantity is analyzed by setting up a buffer zone in the center of stream, and by changing a farmland area into a natural grass land. Therefore, a farmland area in a subwatershed changes 36.6% into 27.9% and 15.3% comparing to previous land cover change. In the analysis of sediment loads occurrence quantity and nutritive salt load occurrence quantity in subwatershed-2, sediment loads occurrence quantity decreases 52% to about 47%, and nutritive salt load decreases 49% and 34% in compare with previous change. Hereafter, this research will set up the mitigation measures scenario, and find out which is more effective for the mitigation measures.