• 제목/요약/키워드: Muscle structure

검색결과 392건 처리시간 0.025초

Masticatory muscle tendon-aponeurosis hyperplasia accompanied by limited mouth opening

  • Yoda, Tetsuya
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권4호
    • /
    • pp.174-179
    • /
    • 2019
  • Patients with masticatory muscle tendon-aponeurosis hyperplasia (MMTAH) experience limited mouth opening due to restricted muscle extension. Hyperplastic aponeurosis and tendons lead to the restriction of muscle extension. The criteria for the diagnosis of MMTAH are limited mouth opening that progresses very slowly from adolescence, intraoral palpation reveals a hard cord-like structure along the overhang of the anterior border of the masseter muscle on maximum mouth opening, and a square mandible. Conservative treatment, including pharmacotherapy, occlusal splint and physical therapy are ineffective. The standard therapy is surgical treatment, such as anterior partial aponeurectomy of the masseter muscle and coronoidectomy. The long-term results are very satisfying.

수축중인 근육막에서 actin과 myosin 결합의 구조변화에 관한 연구 (A Study On Structure Change of Binding Actin and Moysin On The Contracting Muscle Membrane)

  • 김덕술;박근호
    • 한국응용과학기술학회지
    • /
    • 제25권3호
    • /
    • pp.380-387
    • /
    • 2008
  • The effects of the applied stretch and MgADP binding on the structure of the actin and myosin cross-bridges in rabbit fibers in the rigor state have been investigatedwith improved resolution by x-ray diffraction using synchrotron radiation. To clarify the structure of the ATP hydrolysis intermediates formed by actin and myosin cross-bridges,the effects of various phosphate analogs in the of MgADP on the structure of the thin and thick filaments in glycerinated rabbit muscle fibers in the rigor state investigated by x-ray diffraction with a short exposure time using synchrotron radiation. These results strongly suggest that when MgADP and phosphate analogs such as metallofluorides(BeF3 and AlF4)and vanadate(VO4(Vi)) were added the rigor fibers in the presence of the ATP-depletion backup system, the intensities of the actin-based layer lines were markedly weakened. We found that the intensity of the 14.5 nm-based meridional reflections increase by 20-50% when phosphate analogs such as metallofluorides(BeF3 and AlF4) and vanadate(VO4(Vi)) was added to the rigor muscle.

Anatomical Study on the Heart Meridian Muscle in Human

  • Park Kyoung-Sik
    • 대한한의학회지
    • /
    • 제26권1호
    • /
    • pp.11-17
    • /
    • 2005
  • This study was carried out to identify the components of the human heart meridian muscle, the regional muscle group being divided into outer, middle, and inner layers. The inner parts of the body surface were opened widely to demonstrate muscles, nerves, blood vessels and to expose the inner structure of the heart meridian muscle in the order of layers. We obtained the following results; $\cdot$ The heart meridian muscle is composed of muscles, nerves and blood vessels. $\cdot$ In human anatomy, the difference between terms is present (that is, between nerves or blood vessels which control the meridian muscle and those which pass near by). $\cdot$ The inner composition of the heart meridian muscle in the human arm is as follows: 1) Muscle H-l: latissimus dorsi muscle tendon, teres major muscle, coracobrachialis muscle H-2: biceps brachialis muscle, triceps brachialis muscle, brachialis muscle H-3: pronator teres muscle and brachialis muscle H-4: palmar carpal ligament and flexor ulnaris tendon H-5: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficialis tendon, flexor digitorum profundus tendon H-6: palmar carpal ligament & flexor retinaculum, flexor carpi ulnaris tendon H-7: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficial is tendon, flexor digitorum profundus tendon H-8: palmar aponeurosis, 4th lumbrical muscle, dorsal & palmar interrosseous muscle H-9: dorsal fascia, radiad of extensor digiti minimi tendon & extensor digitorum tendon 2) Blood vessel H-1: axillary artery, posterior circumflex humeral artery H-2: basilic vein, brachial artery H-3: basilic vein, inferior ulnar collateral artery, brachial artery H-4: ulnar artery H-5: ulnar artery H-6: ulnar artery H-7: ulnar artery H-8: palmar digital artery H-9: dorsal digital vein, the dorsal branch of palmar digital artery 3) Nerve H-1: medial antebrachial cutaneous nerve, median n., ulnar n., radial n., musculocutaneous n., axillary nerve H-2: median nerve, ulnar n., medial antebrachial cutaneous n., the branch of muscular cutaneous nerve H-3: median nerve, medial antebrachial cutaneous nerve H-4: medial antebrachial cutaneous nerve, ulnar nerve H-5: ulnar nerve H-6: ulnar nerve H-7: ulnar nerve H-8: superficial branch of ulnar nerve H-9: dorsal digital branch of ulnar nerve.

  • PDF

Fluidic Muscle 실린더의 특성 해석 및 실험 (An Experiments and Characteristics Analysis of the Fluidic Muscle Cylinder)

  • 허신;김동수;김완두;배상규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.974-979
    • /
    • 2004
  • The fluidic muscle cylinder consist of an air bellows tube, flanges and lock nuts. It's features are softness of material and motion, simplicity of structure, low production cost and high power efficiency. In this study, we carried out the finite element modelling and analysis about the main design variables such as contraction ration and force, diameter increment of fluidic muscle cylinder. On the basis of finite element analysis, the prototype of fluidic muscle cylinder was manufactured and tested. Finally, we compared the results between the test and the finite element analysis.

  • PDF

전복의 동결에 관한 연구 2) 동결에 의한 전복조직의 변화 (STUDIES ON FREEZING OF THE ABALONE 2. Histological Changes by Freezing)

  • 송대진
    • 한국수산과학회지
    • /
    • 제11권2호
    • /
    • pp.91-95
    • /
    • 1978
  • 세가지의 동결방법(air blast, semi air blast, still air freezing)으로 전복을 동결하여 $-20^{\circ}C$ 냉장고에서 3개월간 저장하고 동경방법의 처리에 따른 조직적인 변화를 생전복과 비교하여 다음과 같은 결과를 얻었다. 1. 생 전복의 조직구조는 소라의 그것과 비슷하였다. 2. 동결에 의한 근세포의 파괴는 없었다. 3. 동결방법의 차에서 오는 조직변화의 차이는 거의 없으며, 미세 빙결정이 많이 생겼다. 4. 동결에 의한 근조직 피해는 일반 어류보다 적었다.

  • PDF

어깨 근력보조를 위한 엑소수트 설계 (Design of Exo-Suit for Shoulder Muscle Strength Support)

  • 전광우;김태환;김승우;김정준;정현준
    • 로봇학회논문지
    • /
    • 제18권1호
    • /
    • pp.110-116
    • /
    • 2023
  • In this study describes the design of Exo-suit to assist those who work in unstructured positions. The present study aimed to analyze various types of work, especially those performed in unstructured postures by heavy industry workers. Based on the motion capture analysis results, an attempt was made to develop a shoulder muscle-assistive Exo-suit capable of assisting a wearer who is working using shoulder muscles. In the present study, as the first step of developing a shoulder muscle-assistive Exo-suit, different working scenarios were simulated, and the corresponding motion data were estimated using motion capture devices. The obtained motion data were reflected in the design of the Exo-suit. The main structure of the shoulder muscle-assistive Exo-suit was made of a carbon fiber-reinforced composite to obtain the weight reduction. The shoulder muscle assistive Exo-suit was designed to fully cover the range of motion for workers working in unstructured postures.

생체모방 기반 융합 학습 모델을 적용한 '골격근의 구조와 수축'에 대한 디지털 교재 개발 (Development of a Digital Textbook on 'Structure and Contraction Mechanism of Skeletal Muscle' with the Learning Model for Biomimicry-Based Convergence)

  • 김수연;권용주
    • 과학교육연구지
    • /
    • 제42권2호
    • /
    • pp.95-105
    • /
    • 2018
  • 이 연구의 목적은 생체 모방 기반 융합 학습 모델을 이용하여 골격근의 구조 및 수축 메커니즘에 대한 디지털 교과서를 개발하는 것이다. 골격근의 구조 및 수축 메커니즘 단원은 고등학교 생명과학I에 포함된 내용이다. 융합 학습 모델은 3D 모델링 및 프린팅을 포함하는 3단계의 생체 모방 기반 융합 학습(Exploration-Design-Implementation)으로 설계되었다. 개발된 디지털 교재는 8차시로 구성되어 있는데, 골격근 탐색, 스케치 앱과 3D 모델링을 이용한 골격근 모방 창의적 설계 2개 차시, 3D 프린팅을 이용하여 설계안의 융합적 구현, 근수축의 탐색, 스케치 앱과 3D 모델링을 이용한 근수축 모방 창의적 설계 2개 차시, 3D 프린팅을 이용하여 설계안의 융합적 구현 등으로 구성되었다. 각 차시는 대화 형 및 모바일 학습을 위해 갤러리 위젯, 미디어 위젯, 프레젠테이션 위젯, 스케치 위젯, 클라우드, 설문 위젯 및 평가 위젯의 컨텐츠를 포함하고 있다. 개발 된 디지털 교과서를 고등학생 20 명에게 투입한 결과 학생들의 생명과학 학습에 효과가 긍정적인 것으로 나타났다. 또한 이 연구에서 개발된 생체 모방 기반 융합 학습 디지털 교재는 학생들의 창의적 설계 및 구현 능력의 향상에서 효과적인 학습자료로 평가되었다. 이러한 결과를 볼 때 디지털 교재는 학생들의 흥미와 생명과학에 대한 자기주도적 학습에 유용한 자료임을 보여주었다.

안와파열골절 급성기의 CT영상을 이용한 계측학적인 연구 (Measurement Analytical Study of Computed Tomography of the Orbital Structure in Acute Blow-out Fracture)

  • 정성호;신승한;박승하;구상환
    • Archives of Plastic Surgery
    • /
    • 제34권1호
    • /
    • pp.44-51
    • /
    • 2007
  • Purpose: Blow-out fracture is one of the most common fractures in facial trauma. It is diagnosed by Computed Tomography(CT) scan, which is considered as the most effective diagnostic tool. Since, the Picture Archiving Communication System(PACS) has been provided recently to many hospitals, doctors are more familiar with imaging software of PACS. Because this software has many useful measuring tools, doctors can measure orbital structure easily and make a plan for treatment with its data. Therefore, authors intended to analyze the data of orbital structure measured with PACS imaging software and evaluate its usefulness. Methods: The charts and CT images of 100 patients, which were 50 patients with medial wall fracture and 50 patients with floor fracture, were reviewed. Patients were selected by pre-determined criteria and their CT images were measured with image software of PACS. 'Extraocular muscle thickness', 'Defect ratio'(ratio of defect area to normal area) and 'Globe position index' were measured and analyzed statistically. Results: The thickness of inferior rectus muscle and medial rectus muscle was simultaneously increased in acute-stage of blow-out fracture. The medial rectus muscle was more thickened in medial wall fracture and inferior rectus was more thickened in floor fracture, respectively. In acute blow-out fracture, globe position is exophthalmic rather than enophthalmic. Especially in floor fracture, numerical value summed up thickness of all extraocular muscle is correlated to the defect ratio and globe position index. Conclusion: Clinicians can decide globe position or presume defect ratio in inferior wall fracture by measurement of CT image in acute blow-out fracture using PACS.