• 제목/요약/키워드: Municipal wastewater

검색결과 297건 처리시간 0.027초

FC/FS 비율에 의한 분변오염원의 출처파악의 유효성 (Validity of Fecal Pollution Source Tracking using FC/FS Ratio)

  • 박지은;이영옥
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.28-34
    • /
    • 2010
  • This study was conducted to assess the validity of fecal coliforms to fecal streptococci ratio (FC/FS) for distinguishing the human from animal origin of fecal pollution in surface water. FC/FS ratio determined in effluent from municipal wastewater and human feces treatment plant (WWTP) and in downstream close to discharge of human feces was above 4 which indicates human origin. However FC/FS ratios determined seasonally in other water zones of the Nakdong River, even in the same sampling site, varied differently (above 4 or less than 0.7) due to different survival time of FC and FS and other environmental factors such as rainfall in watershed. Compared to other season, FC/FS ratios in winter were much lower regardless of the origin. It is concluded that the FC/FS ratio determined in surface water is not always valid for determining the origin of fecal pollution.

하수처리장으로 부터의 질소제거 (Nitrogen Removal from Municipal Waste Water Treatment Plants)

  • 최의소
    • 수도
    • /
    • 통권69호
    • /
    • pp.23-46
    • /
    • 1994
  • 하수처리장으로부터의 질소제거는 과거 3차 처리의 개념을 토대로 시설비가 고가로 소요되었으나 현재는 2차 처리시에 탄소제거와 함께 질소를 제거하는 개념으로 바뀌어지고 있다. 또한 질소제거는 탄소제거만에 의한 수질보호 차원에서 암모니아 독성을 제거하며 질소산화에 의한 추가 산소소모를 감소시키는 효과를 기대할 수 있다. 2차 처리시설에 의한 질소제거는 약 6%의 시설비와 연간 유지관리비의 증가에 불과하다. 질소제거는 하천이나 호소수의 수질개선뿐만 아니라 독성제거와 산소공급 내지 산소결핍 가능성을 저하시키며 하수처리장의 수질을 향상시킨다. 따라서 앞으로 질소제거는 모든 하수처리장의 2차 처리시설에 적용이 되리라는 것이 국제적인 추세이다. 하수처리장이 계속해서 신설되고 있는 우리나라로서는 이러한 개념을 되도록 빨리 받아들여 뒤늦게 질소제거를 수행함에 따르는 추가 비용의 낭비를 최소화 시키는 것이 현명하리라 생각된다.

  • PDF

지하수자원의 환경적으로 지속가능한 개발 방안 (Schemes for the Environmentally Sound and Sustainable Development of Groundwater Resources)

  • 홍상표;김정욱
    • 환경영향평가
    • /
    • 제5권2호
    • /
    • pp.49-57
    • /
    • 1996
  • On the basis of sustainable long-term water resources planning, the development of ground water resources should be interlocked with the surface water development In considering the intertemporal equity, overpumping of groundwater may diminish or eliminate the groundwater resources stock of post-generations. Regulatory landuse zoning for groundwater resources recharge area is indispensable measures to prevent groundwater pollution. Adequate treatment of polluted water from various sources such as municipal sewage, industrial wastewater, landfill site leachate, and abandoned boring wells, is also necessary for groundwater protection. To preserve groundwater resources as common property goods, groundwater use tax should be imposed upon the large scale groundwater use. Finally, the establishment of groundwater development license system is recommended to achieve the social optimal production and to avoid external diseconomy.

  • PDF

용수-폐수 분배모형의 민감도분석 (Sensitivity Analysis of Water Supply-Wastewater Allocation Model)

  • 이길성
    • 물과 미래
    • /
    • 제16권1호
    • /
    • pp.41-48
    • /
    • 1983
  • 세계 식량 및 에너지 위기의 심화에 따른 여러 가지 용수공급의 경합에 맞추어, 시스템공학의 지역적 수자원 개발 계획에 대한 적용이 중요시되고 있다. 도시 수자원과 토지 이용 전략 및 이에 따른 환경 영향에 관한 논의와 함께, 분배 관망의 최소 비용안을 구하기 위한 선형계획 및 비선형계획 방법을 제시하였다. 또한 주어진 가상용수 수요에 대비한 부배 모형의 작성 및 실제전산 처리를 통하여 장래 용수 공급원에 관한 민감도를 분석하였다.

  • PDF

생하수의 퍼클로레이트 생분해 특성 (Bioreduction Characteristics of Perchlorate in Raw Sewage)

  • 홍성환;최혁순
    • 한국수처리학회지
    • /
    • 제26권6호
    • /
    • pp.81-87
    • /
    • 2018
  • This research was done to investigate the bioreduction characteristics of perchlorate in raw sewage because sewage contains biodegradable organics and various microorganisms for biological perchlorate reduction. Two different types of sewage were tested for biological perchlorate reduction in the flasks. Sewage A was collected from the screening equipment and sewage B was collected from the primary settlement in the municipal wastewater treatment facilities. Perchlorate was completely reduced within 72hours from 8.2 and 10.4 mg/L in the sewage A and sewage B flask tests. When perchlorate and nitrate were added in sewage A, both perchlorate and nitrate were reduced. However, perchlorate and nitrate removal rates were 9.3% and 64.0% at 72hours in sewage B. Perchlorate reduction was significantly inhibited by high salinity(0.5% NaCl) in the sewage A and B. These results showed the sewage has potential for the biological perchlorate reduction in the sewage pipe.

혐기성 생물반응기에 의한 축산폐수의 처리 (Treating Swine Wastewater by Anaerobic Bioreactors)

  • 이국희;김종수
    • 한국환경농학회지
    • /
    • 제18권1호
    • /
    • pp.54-60
    • /
    • 1999
  • 축산폐수의 효율적 처리와 최적 메탄발생을 위하여 AF 그리고 이단의 ASBF-PR과 ASBF-SP 실험실적 생물반응기를 구성하고 $35^{\circ}C$ 항온조에서 수리학적체류시간 $1{\sim}2$일 그리고 유기물부하 $1.1{\sim}63kg-COD/m^3{\cdot}d$까지 연속 운전하여 처리효율을 비교, 분석하였다. 하수종말처리장의 혐기성 소화조 잉여 슬러지에 의한 혐기성 생물반응기의 식종은 효과적이었으며, 적응 기간은 약 40일 정도가 소요되었다. 생물반응기는 COD 제거율 $66.4{\sim}84.9$% 그리고 바이오 가스 발생량은 제거된 COD 기준 $0.333{\sim}0.796m^3/kg-COD{\cdot}d$. 으로 축산폐수의 처리에 효율적이었으며 유입 COD의 증가와 수리학적체류시간의 감소에 의한 유기물부하 증가의 경우 COD 제거율은 감소하고 바이오가스 발생량은 증가하였다. 높은 유기물부하에서 AF와 ASBF-PR의 처리효율은 비슷하였으며 ASBF-SP보다 우수하였다. 생물반응기에 충진된 미디어의 공극율과 공극의 크기가 비표면적에 비교하여 유기물질 제거능력 향상에 영향을 미치는 것으로 나타났다. 유입수 TKN 농도가 $1,540{\sim}1,870mg/L$ 범위에서 메탄발효 미생물의 활동은 저해영향을 받아 생물반응기의 처리효율과 바이오가스 발생량은 각각 50% 이하로 감소되는 것으로 나타났으므로 혐기성 소화가 축산폐수의 처리에 주 공정으로 응용된다면 전처리에 의한 TKN의 제거는 필수적이다.

  • PDF

ASBR(Anaerobic Sequencing Batch Reactor) 공정의 F/R비가 암모니아가 탈기된 축산폐수의 유기물 제거에 미치는 영향 (Effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) Process on Removal of the Organic Matters in Ammonia Stripped Swine Wastewater)

  • 황규대;조영무
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.687-694
    • /
    • 2005
  • Lab-scale experiments have been carried out to investigate the effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) process on the removal of the organic matters in ammonia stripped swine wastewater. Three ASBR inoculated with sludge mixed with granular sludge of UASB (Upflow Anaerobic Sludge Blanket) and anaerobic digested sludge of municipal wastewater treatment plant were operated. Ammonia stripped swine wastewater was used as influent. Prior to conducting the experiments with varied conditions, the effect of increasing organic loading rate from 2.34 to $5.79gTCOD_{Cr}/L$-day at a fixed F/R ratio of 0.1 on the organic removal efficiency has been studied during start-up period. As the result of the experiment, under the condition of varied organic loadings, less than $4.14gTCOD_{Cr}/L$-day, the removed efficiency $TCOD_{Cr}$ of the ASBR process is 83% resulted from the mean value of effluent $TCOD_{Cr}$, 9,125 mg/L during the start-up period. Then ASBRs were operated with F/R ratio of 0.024, 0.303 and 0.91 respectively. Organic loading rate was increased from 4.56 to $15.43gTCOD_{Cr}/L$-day to investigate the effects of F/R ratio and organic loading rate on the organic removal efficiency. As the result of the experiment, less than $6.23gTCOD_{Cr}/L$/L-day, F/R ratio haven't an effect on the organic removal efficiency and the mean removal efficiency of TSS, $TCOD_{Cr}$ and $SCOD_{Cr}$ was about 80%, 86% and 78% at the all of F/R ratio. But as organic loading rate was increased from 8.54 to $12.04gTCOD_{Cr}/L$-day at the F/R ratio of 0.024, the removal efficiency of $SCOD_{Cr}$ decreased from 71% to 63%. The range of decreased removal efficiency of $SCOD_{Cr}$ at the F/R ratio of 0.024 was much more higher than at the F/R ratio of 0.303, 0.91. Thus, as organic loading rate was increased, ASBRs were operated with high F/R ratio to obtain high removal efficiency.

바이오산업폐수처리수의 재이용을 위한 hybrid 인공습지 시스템의 적용가능성 연구 (Application of the Hybrid Constructed Wetland for a Reuse of the Effluent from Bio-industrial Wastewater Treatment Plant)

  • 신재석;김성철;조광주;최충호;최인욱;박정자;박구현
    • 한국습지학회지
    • /
    • 제11권1호
    • /
    • pp.115-121
    • /
    • 2009
  • 생물산업 연구단지에서 발생되는 폐수를 처리하기 위해 건설된 폐수처리장의 3차 처리시설로 hybrid 인 공습지 시스템을 적용하여 최종 방류수의 재이용가능성을 평가하였다. 폐수처리를 위한 1차 처리공정은 화학적 처리(약품 응집)이며, 2차 처리공정은 생물학적 처리(표준활성슬러지법)로 구성되어 있다. 3차 처리시설로서 hybrid 인공습지는 자연통풍시스템이 구비된 호기성 인공습지와 혐기/무산소성 인공습지가 순차적으로 연결된 시스템이다. Hybrid 인공습지로 유입되는 2차 생물학적 처리공정의 처리수 농도는 BOD, SS, T-N 및 T-P의 평균 농도가 각각 53mg/L, 48mg/L, 34mg/L 및 3mg/L로 나타났으며, hybrid 인공습지에서의 최종방류수의 BOD, SS, T-N 및 T-P의 평균농도는 각각 2.3mg/L, 1.2mg/L, 7.95mg/L 및 0.83mg/L로 나타나 하수처리수의 재이용권고수질기준과 비교할 때 조경용수나 세척용수 등의 용도로 직접 재이용이 가능한 수질이 확보될 수 있었다. Hybrid 인공습지는 반응조를 호기 및 혐기/무산소 조건으로 기능화 함으로서 높은 효율로 오염물질이 제거될 수 있었으며, 이러한 결과로부터 다양한 하수 및 폐수의 3차 처리시설로서 활용이 가능한 것으로 평가되었다.

  • PDF

Pilot scale 세정산발효를 이용한 하수 일차슬러지의 산발효 (The Recovery of Carbon Source from Municipal Primary Sludge using Pilot Scale Elutriated Acidogenic Fermentation)

  • 권구호;김시원;정용준;민경석
    • 한국습지학회지
    • /
    • 제15권2호
    • /
    • pp.165-170
    • /
    • 2013
  • 본 연구에서는 하수일차슬러지의 가용화 및 산발효를 위한 pilot scale 세정산발효공정의 운전 특성을 검토하였다. 하수일 차슬러지의 가용화 및 산발효 특성을 평가하기 위해 SRT, 세정수 및 운전온도를 변화시켜 실험을 수행하였다. 세정산발 효공정의 가용화율은 온도가 높을수록 증가하는 반면, 산생성율은 중온조건($35^{\circ}C$)이 고온조건($55^{\circ}C$)보다 높게 나타났다. VS 감량은 약 56%, 슬러지 부피감량은 약 93%까지 나타났다. 가용화측면에서 세정산발효공정의 최적운전조건은 pH 9, $35^{\circ}C$ 및 SRT 5일이 적합 할 것으로 판단된다.

Nitrate Removal by Pseudomonas fluorescens K4 Isolated from a Municipal Sewage Treatment Plant

  • Lee, O-Mi;Oh, Jong-Hyeok;Hwang, Doo-Seong;Choi, Yun-Dong;Chung, Un-Soo;Park, Jin-Ho;Kim, Min-Ju;Jeong, Seong-Yun;Lee, Sang-Joon
    • 한국환경과학회지
    • /
    • 제16권11호
    • /
    • pp.1219-1223
    • /
    • 2007
  • The removal of nitrogen compounds from a wastewater is essential and it is often accomplished by bio-logical process. An aerobic nitrate-removing bacterium was isolated from a municipal sewage treatment plant and soil. On the basis of its morphological, cultural and physiological characteristics and 16S rRNA sequencing data, this strain was identified as Pseudomonas fluorescens, and named as P. fluorescens K4. The optimal conditions of the initial pH and temperature of media for its growth were $7.0{\sim}8.0$ and $30^{\circ}C$, respectively. P. fluorescens K4 was able to remove 99.9% of nitrate after 24 h in a culture. The strain could grow with a nitrate concentration up to 800 mg/l and was able to remove 99.9% of nitrate after 104 h of incubation. The optimal electron donor was sodium citrate for a nitrate removal. The strain K4 showed a capability of a complete nitrate removal when the initial C/N ratio was 1.0. An effect of the initial seed concentration was observed for a cell of 10% (v/v) for a nitrate removal. Especially P. fluorescens K4 could completely remove 200 mg/l ammonium for 3 days.