• Title/Summary/Keyword: Municipal solid

Search Result 325, Processing Time 0.028 seconds

Evaluation of Landfilling Method of Organic Sludge from Mix of Pre-treated Organic Sludge and Municipal Solid Waste (전처리된 유기성오니와 생활폐기물 혼합에 따른 유기성오니 매립방법 평가)

  • Ko, Jae-Young;Phae, Chae-Gun;Do, In-Hwan;Park, Joon-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.278-285
    • /
    • 2008
  • This research was performed to evaluate the landfilling method of organic sludge from mix of pre-treated organic sludge (OS) and municipal solid waste(MSW). Organic sludges were dried, composted, and solidified as pre-treatment and the OS and MSW were mixed in ratios of 2 to 8 and 4 to 6. Approximately 1,800$\sim$2,500 L of landfill gas(LFG) was generated in the lysimeter with solidified-OS, which was higher than 1,150$\sim$1,650 L of the dried- and composted- ones. Maximum H$_2$S concentration was found in the following order : Composted-20(80 ppmv) > Composted-40(55 ppmv) > Dried-20(30 ppmv) > Dried-40 $\fallingdotseq$ Solidified-20 $\fallingdotseq$ Solidified-40 (20 ppmv). BOD$_5$ at initial leachate generation period was 38,000 mg/L for Composted-40, 28,000 mg/L for Dried-40, 26,000 mg/L for Dried-20, 21,000 mg/L for Composted-20 and Solidified-40, and Solidified-20 for 17,000 mg/L. In the final period of experiment, BOD$_5$ was low as 300$\sim$500 mg/L in the lysimeter with solidified-OS and MSW and showed 2,000$\sim$3,500 mg/L in dried- and composted- ones. As the results, landfilling by mix of solidified-OS and MSW was evaluated as the most appropriate method for biodegradable organics. Direct landfilling of OS is permitted for landfill site with CDM facility. Therefore, mixed landfilling of solidified-OS and MSW should be considered for much more LFG generation as methane.

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.

A Study on the PCDDs/PCDFs Contents in the Flue Gas of Muncipal Solid Waste Incinerator(III) -Emission Concentration Varying the Combustion Temperature- (쓰레기소각로 배출가스의 PCDDs/PCDFs 함유량에 관한 연구(III) -소각로 연소 온도변화에 따른 보일러 후단에서의 배출 농도 변화-)

  • Shin, S.K.;Chung, Y.H.;Lee, J.I.
    • Analytical Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.540-549
    • /
    • 1999
  • The combustion temperature was controlled between $880^{\circ}C$ to $1070^{\circ}C$ to find the relation the combustion temperature and emission amount of PCDDs/PCDFs in the Municipal solid waste incinerator. The emission amount of PCDDs/PCDFs decreased when the temperature increased in the rear of the boiler. The PCDDs/PCDFs concentration were detected $7.82ng-TEQ/Nm^3$ at $880^{\circ}C$, $6.97ng-TEQ/Nm^3$ at $970^{\circ}C$ and $6.13ng-TEQ/Nm^3$ at $1070^{\circ}C$. Also, The chlorophenols, chlorobenzenes, and PCB concentration decreased by increasing the temperature from $880^{\circ}C$ to at $1070^{\circ}C$, and the isomer of the prescsors had a tendency to emit the higbly cbiorinated compounds.

  • PDF

Study on $CaCO_3$ Preparation from MSWI Fly Ash (생활쓰레기 소각(燒却)비산재로부터 $CaCO_3$ 제조(製造)에 관한 연구(硏究))

  • Choi, Woo-Zin;Park, Eun-Kyu
    • Resources Recycling
    • /
    • v.15 no.5 s.73
    • /
    • pp.47-51
    • /
    • 2006
  • The total amount of ash generated from the municipal solid waste incineration(MSWI) in Korea was approximately 420,000 tons in 2005 including 68,000 tons of fly ash. Fly ash from MSWI generally contains high amount of CaO (upto ${\sim}50%$) due to the treatment of flue gas by spraying CaO-base materials. Currently, most of fly ash generated is finally ended up with specially designed landfill sites and only less then 20% of fly ash is recycled. In the present work, preparation of $CaCO_3$ from the MSWI ny ash was studied to promote the fly ash recycling. Fly ash obtained from the dust collector in stoker-type MSWI is used to selectively dissolve CaO by using the sugar solution. Then, $CO_2$ gas was passed through the dissolved solution to pro- duce $CaCO_3$ powder. The optimum conditions for CaO dissolution were solid content 10%, reaction time 15 minutes, sugar concentration $10{\sim}15%\;and\;pH\;10.5{\sim}11.0$. The high grade $CaCO_3$ powder was obtained and the experimental conditions are also discussed.

Enhanced Anaerobic Degradation of Food Waste by Employing Rumen Microorganisms (Rumen 미생물을 이용한 주방폐기물 혐기성소화의 효율증진 방안)

  • Shin, Hang-Sik;Song, Young-Chae;Son, Sung-Sub;Bae, Byung-Uk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.1 no.1
    • /
    • pp.103-113
    • /
    • 1993
  • Every year, over $3.37{\times}10^7$ ton of municipal solid waste is generated in Korea, of which about 28% is organic food waste from restaurant, dining halls and households etc. Methane conversion of the food waste by anaerobic digestion could be a viable approach for energy recovery as well as safe disposal of the waste. However, as food waste is composed of highmolecular complex polymers such as cellulose, lignin and protein, anaerobic digestion of food waste has not been efficient in terms of volumetric loading rate, solid retention time and extent of anaerobic degradation. In this research, the improved anaerobic degradation of food waste was attemped by applying rumen microorganisms to anaerobic digestion. Acidification efficiency of food waste by rumen microorganisms was compared with that of conventional acidogenesis. And optimum acidification conditions by rumen microorganisms were also determined. For the experiments, anaerobic batch reactors of 600 mL was fed with the processed (dried and milled) food waste obtained from a restaurant. Ultimate volatile fatty acid (VFA) yield produced by rumen microorganisms was about 8.4 meq VFA/g volatile solid (VS) that is 95% of the theoretical value. This yield was not much different from that of conventional acidogenesis, but hydrolysis rate was about twice faster. Cumulative VFA concentration increased from 66 meq/L to 480 meq/L, when the initial TS was increased from 1% to 15%. But VFA yield at 15% TS was half of that at 1% TS. This inhibition on the acidification might be caused by the rapid drop of pH and higher concentration of nonionized VFA. Optimal pH and temperature range for the acidification were about 6.0~7.5 and $35{\sim}45^{\circ}C$, respectively.

  • PDF

A Study on Methanogenic Bacteria-Activated Leachate Recirculation Method for Enhancing Waste Stabilization and Landfill Gas Production from a Solid waste Landfill (매립가스 발생량 및 폐기물 안정화 촉진을 위한 메탄생성균 활성 침출수 재순환 공법에 관한 연구)

  • Park, Jin-Kyu;Kang, Jeong-Hee;Chong, Yong-Gil;Lee, Nam-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.2
    • /
    • pp.66-75
    • /
    • 2012
  • The objective of this study was to assess the effects of methanogenic bacteria-activated leachate recirculation method for enhancing waste stabilization and landfill gas production from a solid waste landfill. To simulate a conventional landfill (Lys-A), a landfill recirculated only fresh leachate (Lys-B), and two landfills recirculated leachate after pretreating with ASBR (Lys-C and Lys-D), four lysimeters were operated over a period of 4 years. Lys-D was recirculated two times of pretreated leachate volume than that of Lys-C. In the case of the landfill recirculated only fresh leachate and the landfill recirculated leachate after pretreating with ASBR, methane productions were increased until about 600 days, but there were not effect of leachate recirculation for enhancing methane production after about 600 days. It was assumed that leachate recirculation into fewer biodegradable organic wastes had not effect to enhance landfill gas production. Lys-C and Lys-D showed the highest performance for enhancing cumulative methane yield as well as acceleration waste stabilization. In cumulative methane yield, Lys-C (35.51 mL $CH_4/g$ VS) and Lys-D (36.12 mL $CH_4/g$ VS) were much higher than Lys-A (28.37 mL $CH_4/g$ VS) and Lys-B (30.07 mL $CH_4/g$ VS). In case of between Lys-B and Lys-C with the same recirculation rate, COD concentration in Lys-C was more rapidly decreased compared with that in Lys-B. This was attributed to the presence of methanogenic bacteria as well as dilution of inhibitory substances by the methanogenic bacteria-activated leachate recirculation. Therefore, the landfill recirculated leachate after pretreating with ASBR was found to be the most appropriate operating techniques for enhancing waste stabilization and landfill gas production.

Thermophilic Anaerobic Biodegradability of Agro-industrial Biomass (농축산바이오매스 고온 혐기성 생분해도 평가)

  • Heo, Namhyo;Kang, Ho;Lee, Seungheon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.101-101
    • /
    • 2010
  • Anaerobic digestion(AD) is the most promising method for treating and recycling of different organic wastes, such as organic fraction of municipal solid waste, household wastes, animal manure, agro-industrial wastes, industrial organic wastes and sewage sludge. During AD, i.e. organic materials are decomposed by anaerobic forming bacteria and fina1ly converted to excellent fertilizer and biogas which is a mixture of carbon dioxide and methane. AD has been one of the leading technologies that can make a large contribution to produce renewable energy and to reduce $CO_2$ and other green-house gas(GHG) emission, it is becoming a key method for both waste treatment and recovery of a renewable fuel and other valuable co-products. Currently some 80% of the world's overall energy supply of about 400 EJ per year in derived from fossil fuels. Nevertheless roughly 10~15% of this demand is covered by biomass resources, making biomass by far the most important renewable energy source used to date. The representative biofuels produced from the biomass are bioethanol, biodiesel and biogas, and currently biogas plays a smaller than other biofuels but steadily growing role. Traditionally anaerobic digestion applied for different biowaste e.g. sewage sludge, manure, other organic wastes treatment and stabilization, biogas has become a well established energy resource. However, the biowaste are fairly limited in respect to the production and utilization as renewable source, but the plant biomass, the so called "energy crops" are used for more biogas production in EU countries and the investigation on the biomethane potential of different crops and plant materials have been carried out. In Korea, with steadily increasing oil prices and improved environmental regulations, since 2005 anaerobic digestion was again stimulated, especially on the biogasification of different biowastes and agro-industrial biomass including "energy crops". This study have been carried out to investigate anaerobic biodegradability by the biochemical methane potential(BMP) test of animal manures, different forage crops i.e. "energy crops", plant and industrial organic wastes in the condition of thermophilic temperature, The biodegradability of animal manure were 63.2% and 58.2% with $315m^3CH_4/tonVS$ of cattle slurry and $370m^3CH_4/tonVS$ of pig slurry in ultimate methane yields. Those of winter forage crops were the range 75% to 87% with ultimate methane yield of $378m^3CH_4/tonVS$ to $450m^3CH_4/tonVS$ and those of summer forage crops were the range 81% to 85% with ultimate methane yield of $392m^3CH_4/tonVS$ to $415m^3CH_4/tonVS$. The forge crops as "energy crops" could be used as good renewable energy source to increase methane production and to improve biodegradability in co-digestion with animal manure or only energy crop digestion.

  • PDF

Evaluation of Performance Index for Optimization of Food Waste Treatment and Recovery Facility (음식물류폐기물 자원화시설 최적화를 위한 이행지표 평가)

  • Kim, Jong-Hwan;Park, Joon-Seok;Phae, Chae-Gun
    • Clean Technology
    • /
    • v.22 no.3
    • /
    • pp.181-189
    • /
    • 2016
  • This research was performed to evaluate the food waste recovery facility using optimization performance index. In 2014, the generated amount of food waste occupied approximately 27% in total municipal solid waste. The 97.2% of the food waste was recycled and the others were treated through landfill and incineration in the portion of 0.9% and 1.9%, respectively. In food waste recovery facilities of year 2014, the composting and feed facilities were 49.5% and 22.9%, respectively. The feed facility showed higher scores in all technological, environmental, and especially economical evaluations than those of composting facility. As results of overall optimization performance index, the feed facility has higher score of 61.5 than 52.7 of composting facility. It was demonstrated that the feed facility has the advantage, compared with the composting facility.

A Study on Food-waste Management of Public School Food Service in Jeonbuk Province (전북지역 공립학교에서의 음식물쓰레기 처리에 관한 실태)

  • Jeung, Yun-Ho;Jung, Su-Jin;Kim, Soo-Ran;Cha, Youn-Soo
    • Journal of the Korean Dietetic Association
    • /
    • v.14 no.1
    • /
    • pp.51-63
    • /
    • 2008
  • The purpose of this study was to understand the management status of food wastes in school meal to find the effective ways that would reduce and recycle them. Data was collected using questionnaires from 223 school dietitians located in Jeonbuk area. The results were as followed : 1) Waste was managed by the dietitians(54.7%) and cook(42.2%). The waste disposal contract was made by dietitians(65.0%), executives(31.4%). Therefore, school dietitians had primary responsibilities in the waste management. 2) As disposal ways, 48.9% processed municipal solid waste and food waste together and 46.6% processed separately. 3) A half of schools(52.9%) produced food wastes weighed under 10$\sim$15kg daily and using food wastes as animal food for farms was most popular method to dispose(87.4%). 4) Reasons to have food-wastes were disliking the taste of menu(50.2%) and the inappropriate ways of dealing with remaining food(64.1%) and donating to food bank(33.6%) in order. 5) The suggested ways to reduce the food-waste was to improve on cooking method(72.2%), changing of portion size(61.0%), measuring the amount of leftover food(53.4%) and requesting cooperation to educators(52.9%). 6) The reported consequences of reducing the food waste were: lowered grocery expenses(46.2%), and inspiring students on helping environmental preservation(23.8%). Therefore, the administration should work on finding a method to reduce food-waste and a way to use these resources efficiently. It is important to induct student's attitude on recycling remaining products by using food bank via nutrition education. Dietitian also should consider to reduce the leftover of food by using a standardized recipe.

  • PDF

Exposure Assessment of PCDD/Fs and Monitoring of Health Effects on Workers and Resident near the Waste Incinerators in Korea (국내 일부 소각장 근로자와 주변지역주민들의 PCDDs/Fs 노출과 건강 영향 평가)

  • Hong, Yun-Chul;Lee, Kwan-Hee;Kwon, Ho-Jang;Jang, Jae-Yeon;Leem, Jong-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.4
    • /
    • pp.314-322
    • /
    • 2003
  • Objectives : In this study, the exposure status of the hazardous substances from incinerators, such as polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), were studied , and the relationship between the exposure of these hazardous substances and their heath effects on the workers and residents near municipal solid waste (MSW) incinerators and an industrial incinerator investigated. Methods : Between July 2001 and Jure 2002, 13 workers at two MSW incinerators, 16 residents from the area around the two MSW incinerators, 6 residents from the control area, and further 10 residents near an industrial incinerator, estimated to emit higher levels of hazardous substances, were interviewed. Information, including sociodemographic information, personal habits, and work history, detailed gynecologic and other medical history were collected through interviews. Blood samples were also collected from 45 subjects, and analyzed for PCDD/DFs, by high resolution gas chromatography -high resolution mass spectrometry, using the US EPA 1613 method. In addition to the questionnaire survey, urinary concentrations of 8-hydroxydeoxyguanosine (8-OH-dG) and malondialdehyde (MDA) were measured as oxidative injury biomarkers. The urinary concentrations of 8-OH-dG were determined by in vitro ELISA, and the MDA by HPLC, using u adduct with thiobarbituric acid. Results : The PCDD/DFs concentrations in the residents near the industrial incinerator were higher than those in the controls, workers and residents near the MSW incinerators. The average TEQ (Toxic Equivalencies) concentrations of the PCDD/DFs in residents near the industrial incinerator were 53.4pg I-TEQs/g lipid. The estimated daily intakes were within the tolerable daily intake range (1-4 pg I-TEQ/Kg bw/day) suggested by WHO (1997) in only 30% to the people near the industrial incinerator. Animal studies have already shown that even a low body border of PCDD/DFs, such as 10 ng TEQ/kg bw, can cause oxidative damage in laboratory animals. Our study also showed that the same body burden of PCDD/DFs can cause oxidative damage to humans. Conclusions : The exposures to PCDD/DFs and the oxidative stress of residents near the industrial incinerator, were higher than those in the controls, workers and residents near the MSW incinerators. Proper protection strategies against these hazardous chemicals are needed. Because a lower body burden of PCDD/Fs, such as 10ng TEQ/kg bw, can cause oxidative damage, the tolerable daily intake range should be restrictedly limited to 1pg I-TEQ/kg bw/day.