• Title/Summary/Keyword: Municipal Wastewater Treatment Plant

Search Result 98, Processing Time 0.02 seconds

The Effect of HRT and SRT on Treatment Efficiency of Activated Sludge Process for Low Concentration Municipal Sewage (저농도 도시하수 처리를 위한 활성슬러지공정에서 HRT 및 SRT가 처리효율에 미치는 영향)

  • Whang, Gye Dae;Kim, Min Ho;Ko, Sae Bom
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.64-73
    • /
    • 1997
  • Most of the municipal wastewater treatment plants operated in Korea are designed for high concentrations municipal sewage. However, activated sludge process employed by municipal wastewater treatment plant is operated at low organic loading. The objective of this study was to determine optimum operating condition of activated sludge process for treatment of low concentration municipal sewage. Three bench scale activated sludge reactors were operated to investigate the effect of HRT and SRT on the COD and TSS removal efficiency. The average concentration of TSS, SCOD, SBOD and TKN in influent were 118mg/l, 61mg/l, 21mg/l, and 12mg/l, respectively. The activated sludge reactors operated with various HRT and SRT showed about 89-93% TSS removal efficiency. HRT and SRT does not affect the TSS removal efficiency of actvatied sludge process significantly. However, HRT affected the SCOD removal efficiency slightly. As the HRT decreases from 13hours to 3hours, the SCOD removal efficiency decreases from 67% to 56%. The average effluent TCOD concentration of the reactor operated with 3hours of HRT was approximatly 40-45mg/l. Kinetic coefficient yield (Yt) and decay coefficients(Kd) were 0.594-0.954 mgMLVSS/mgCOD and $0.0197-0.0317day^{-1}$, respectively. Low concentration municipal sewage can be treated with 3 hours of HRT without effluent quality deterioration and SRT does not affect the substrate removal efficiency at this operation condition.

  • PDF

Treatment of Domestic Wastewater by the Application of Electrochemical Membrane Bioreactor and Generation of Bioelectricity

  • Yadav, Saurabh;Kamsonlian, Suantak;Pal, Shubham
    • Applied Chemistry for Engineering
    • /
    • v.33 no.5
    • /
    • pp.532-537
    • /
    • 2022
  • The need for obtaining treated wastewater that meets high quality standards for discharge or reuse necessitates the use of highly efficient wastewater treatment techniques. In the present study, experiments have been carried out to reduce the concentration level of biological oxygen demand (BOD), chemical oxygen demand (COD), and total dissolved solids (TDS) from the wastewater sample. Treatment of sample of a real municipal wastewater collected from a sewage treatment plant (STP) was carried out in an electrochemical membrane bioreactor (EMBR). The EMBR was operated continuously for five days, and readings were taken at regular intervals. This paper has experimental results conducted in EMBR that indicate reduction of BOD, COD, and TDS levels of up to 32.25%, 29.25%, and 31.93%, respectively. Further, it was observed that a current of magnitude of 0.00752 mA was generated due to the metabolic activities of bacteria present in municipal wastewater, which gradually decreased day by day due to the decay of bacteria.

Survey of the Secondary Effluents from Municipal Wastewater Treatment Plants in Korea (우리나라 하수처리장 방류수 수질현황 및 특성)

  • Kim, Youngchul;An, Ik-Sung;Kang, Min-Gi
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.158-168
    • /
    • 2005
  • In this study, the discharging effluents from have been 9 municipal wastewater treatment plants surveyed for 1 year-period. Statistics including probability distribution, cumulative occurrence concentration and other statistical parameters were presented. In addition, treatment performance and its stability were also discussed. Most of the plants, have an operational problem of high soluble organic content in the secondary effluent which may be associated with the integrated treatment of human and livestock manures. Nitrogen concentration in the effluents were usually higher during the period of summer and winter. It was found that this is mainly due to lack of the proper C/N ratio during the summer, or/and the effects of low temperature and less dilution by dry weather during the winter. Phosphorus concentration is sharply increased in June. Discussion with plant operators told that it is due to the dissolution of phosphate from the sludge accumulated in the primary settling tanks from the early spring to june. During this period, usually, sludge treatment line is highly overloaded with flush-outs of the sediments also stored in the bottom of combined sewer due to the low flow during winter season. Most of the plants can meet new effluent discharge limits of the nitrogen and phosphorus, and total coliform without further treatment.

Rice Cultivation with Reclaimed Wastewater Irrigation for Wastewater Reuse (하수처리수의 재이용을 위한 벼 재배시험)

  • Kang, Moon-Seong;Park, Seung-Woo;Kim, Sang-Min;Seong, Chung-Hyun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.1
    • /
    • pp.75-86
    • /
    • 2004
  • The objective of the research is to develop agricultural resue technologies of reclaiming the effluents from a municipal wastewater treatment plant and reusing for irrigated rice paddies. The Suwon wastewater treatment plant was selected for wastewater reuse tests. The control was the plots with groundwater irrigation (TR#1), the treatment (TR#2) using polluted stream water as it was, and three others using wastewater after treatment. Three levels of wastewater treatments were employed: the effluent from the wastewater treatment plant (TR#3), sand filtering after treatment plant(TR#4), and ultra-violet treatment after sand filtering (TR#5). The randomized block method was applied to wastewater application to paddy rice with five treatments and six replica. The effects of various wastewater treatment levels on water quality, paddy soil, crop growth, yields, and the health hazards were investigated. The primary results indicate that cultivating rice with reclaimed wastewater irrigation did not cause a problem to adverse effects on crop growth and yields. Overall, wastewater could be used as a practical alternative measure for reclaimed wastewater irrigation. However, long-term monitoring is recommended on the effects on soil chemical characteristics and its related health concerns.

Estimate of $CH_4$ Emission Factors in Municipal Wastewater Treatment Plants (하수와 소화슬러지의 $CH_4$가스 배출원단위 산정에 관한 연구)

  • Yang, Hyung-Jae;Park, Jung-Min
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.3
    • /
    • pp.39-46
    • /
    • 2008
  • In order to study the estimate of $CH_4$ emission factors in the municipal wastewater treatment plants, the active sludge process, 5-stage process, Denipho process, and SBR process were investigated. When active sludge process, 5-stage process, and Denipho process were used in wastewater treatment plant, the $CH_4$ emission factors were 2.88, 1.61, and 0.57 g-$CH_4/kg$-BOD, respectively. On the other hand, in the case of SBR process, it was 4.14 g-$CH_4/kg$-BOD. These results indicate that SBR process was effective for $CH_4$ emission in municipal wastewater treatment plants. Using the above processes, the methane emission factor and amount of waste water sludge were $4.78m^3/t$ and $12,204,506m^3/yr$, respectively. The remove of BOD was a range of $93.91{\sim}98.63%$.

Feasibility Study on the Treatment of Food Waste Leachate in Municipal Wastewater Treatment Facility - Case of P city - (음폐수 공공하수처리시설 연계처리 타당성 평가 - P시 사례 -)

  • Park, Jong-Hun;Kang, Shin-Young;Kim, Sang-Hyoun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.2
    • /
    • pp.41-49
    • /
    • 2016
  • P city government considers to treat a part of food waste leachate in a municipal wastewater treatment plant (MWWTP), as the capacity of an existing combined treatment plant for food waste leachate is lower than the generation of food waste leachate in the city. Furthermore, the combined treatment plant also treats landfill leachate and directly discharges the effluent to the sea, which may result in a potential environmental problem. Therefore, this study examined the feasibility of the addition of food waste leachate and the effluent of the combined treatment facility on the MWWTP. Acceptable addition amount of the food waste streams, increased pollution loading on the MWWTP, and the treatment cost were estimated according to four scenarios. All the scenarios estimated that the MWWTP would receive most of the food waste streams according to the manual of the ministry of environment with little increase of pollution loading.

Lime Treatment of Waterworks Sludges for Soil Cover in Municipal Landfilling Site (석회처리에 의한 정수 슬러지의 복토재 활용에 관한 연구)

  • Lim, Sung-Jin;Lee, Jae-Bok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.231-239
    • /
    • 2000
  • Water treatment processes produce sludges resulting from water clarification. Sludge production amount increases each year and its treatment and disposal is growing to social problems according to water demand increase. Water treatment plant sludges can be modified to soil cover in sanitary landfill site through the lime treatment. Compression strength of $1.0kg/cm^2$ or more is recommended for soil cover material in municipal landfilling site. Compression and shear strength properties of modified sludges showed material property improvement applicable for soil cover alternatives. Solidification effect of the modified sludge was observed through the scanning electron microscope. Extraction tests for hazardous components in sludges revealed that extraction levels of cadmium, copper, and lead were below the regulated criteria. When adding 10% calcium hydroxide to water treatment plant sludges, the modified sludges can reach material properties for cover soil after 28 days solidification reaction.

  • PDF

Estimation of energy self-sufficiency in municipal wastewater treatment plant using photovoltaic power simulated by azimuth and hydrophilic coating (방위각과 초친수코팅에 따른 태양광발전량 시뮬레이션과 하수처리장 에너지자립율 산정)

  • An, Young-Sub;Kim, Sung-Tae;Kang, Ji-Hoon;Chae, Kyu-Jung;Yoon, Jong-Ho
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.133-138
    • /
    • 2011
  • This paper presents energy self-sufficiency simulated in municipal wastewater treatment plants (WWTPs) by adopting solar energy production systems that were simulated by varying azimuth and super-hydrophilic coating on the surface of photovoltaic (PV). Relative to the national average energy consumption in WWTPs, the employment of 100 kW PV system was simulated to achieve 2.75% of energy self-sufficiency. The simulated results suggested that the installation of PVs toward South or Southwest would produce the highest energy self-sufficiency in WWTPs. When super-hydrophilic coating was employed in the conventional PV, 5% of additional solar energy production was achievable as compared to uncoated conventional PV. When 100 kW of PV system was installed in a future test-bed site, Kihyeung Respia WWTP located in Yongin, South Korea, the energy self-sufficiency by solar power was simulated to be 1.77%. The simulated solar power production by azimuth and super-hydrophilic coating will be useful reference for practitioners in designing the solar PV systems in the WWTPs.

Capture and Reduction Technology of Greenhouse Gas Using Membrane from Anaerobic Digester Gas (분리막을 이용한 혐기성 소화가스로부터 온실가스 회수저감 기술)

  • Hwang, Cheol-Won;Jeong, Chang-Hun
    • Journal of Environmental Science International
    • /
    • v.20 no.10
    • /
    • pp.1233-1241
    • /
    • 2011
  • The main objective of this experimental investigation was $CH_4$ recovery from biogas generated in municipal and wastewater treatment plant. The polysulfone hollow fiber membrane was prepared in order to investigate the permeation properties of $CH_4$ and $CO_2$. Permeability of $CO_2$ in Polysulfone membrane was 11-fold higher than of $CH_4$ gas. A membrane pilot plant for upgrading biogas was constructed and operated at a municipal wastewater treatment plant. The raw biogas contained 66 ~ 68 Vol % $CH_4$, the balance being mainly $CO_2$. The effect of the operating pressure of feed and permeate side and feed flowrate on $CH_4$ recovery concentration and efficiency were investigated with double stage membrane pilot plant. The $CH_4$ concentration in the retentate stream was raised in these tests to 93 Vol % $CH_4$.

Survey on Public Responses to Odor Produced at Jangrim-Sinpyoeng Municipal and Industrial Wastewater Treatment Plant in Busan (신평장림 공단 폐수처리장 발생의 악취 조사연구)

  • Son, Hyun-Keun;Sivakumar, Subpiramaniyam;Yoon, Young-Hun
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.3
    • /
    • pp.201-208
    • /
    • 2011
  • Objective: Emissions of volatile organic compounds (VOCs) from municipal wastewater treatment plants and industrial wastewater are often overlooked as sources of exposure to toxic chemicals. VOCs from such sources evaporate readily into the air and may have significantly adverse impacts on public health. The present study aimed to establish the concentration of VOCs released from Jangrim-sinpyoeng Municipal and Industrial Wastewater Treatment plant (JWTP) in Busan, South Korea and assess the causes of the odor/stench in the surrounding residential facilities. Stench intensity, frequency and release time, and wind direction were also monitored. Methods: Onsite data were collected on a daily basis from a laboratory located on the JWTP premises through a period spanning 2006 to 2010. A second set of data was obtained in 2006 by conducting a questionnaire survey with 210 respondents living near JWTP. The experimental and survey data were analysed statistically using the SPSS package. Results: The survey results showed that people residing around JWTP strongly perceive a stench from the plant. The intensity of the stench was influenced significantly by wind direction and the location of the apartments facing the JWTP. Public participation formed a significant step in determining the quality of the study environment. Conclusion: Onsite data and survey data obtained in 2006 indicate that the nature of the odor experienced by residents is due to the intensity of total VOCs released by JWTP. However, additional research is needed to determine the effects of the VOC pollution on public health and quality of life.