• 제목/요약/키워드: Multiple-ion

검색결과 294건 처리시간 0.032초

Disturbance in the Daytime Midlatitude Upper F Region Associated with a Medium Scale Electrodynamic Vortex Motion of Plasma

  • Hegai, Valery V.;Kim, Vitaly P.
    • Journal of Astronomy and Space Sciences
    • /
    • 제33권3호
    • /
    • pp.207-210
    • /
    • 2016
  • Under the assumption of the presence of a medium-scale E × B drift vortex of plasma in the daytime midlatitude F region, and using a simplified ionospheric model, we demonstrate that the E × B drift produces noticeable perturbations in the horizontal distribution of the plasma density in the upper F region. The pattern of ion density perturbations shows two separate medium scale domains of enhanced and reduced ion density with respect to the background. The E × B drift does not produce multiple small-scale ion density irregularities through plasma mixing because of the suppression effect of the field-aligned ambipolar plasma diffusion.

Hybrid Sinusoidal-Pulse Charging Method for the Li-Ion Batteries in Electric Vehicle Applications Based on AC Impedance Analysis

  • Hu, Sideng;Liang, Zipeng;He, Xiangning
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.268-276
    • /
    • 2016
  • A hybrid sinusoidal-pulse current (HSPC) charging method for the Li-ion batteries in electric vehicle applications is proposed in this paper. The HSPC charging method is based on the Li-ion battery ac-impedance spectrum analysis, while taking into account the high power requirement and system integration. The proposed HSPC method overcomes the power limitation in the sinusoidal ripple current (SRC) charging method. The charger shares the power devices in the motor inverter for hardware cost saving. Phase shifting in multiple pulse currents is employed to generate a high frequency multilevel charging current. Simulation and experimental results show that the proposed HSPC method improves the charger efficiency related to the hardware and the battery energy transfer efficiency.

Cell Balancing Scheme with Series Coupling of Multiple Primary Windings for Hybrid Electric Vehicle Lithium-Ion Battery Cells

  • Park, Hong-Sun;Kim, Chong-Eun;Moon, Gun-Woo;Lee, Joong-Hui
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.347-349
    • /
    • 2007
  • Charge equalization scheme for HEV lithium-ion battery system is proposed in this paper, where all the primary windings with in parallel bi-directional switches are coupled in series to provide the equalizing energy from the whole battery string to the specific under charged cells. Moreover, to realize minimized size of equalization circuit employing the proposed cell balancing scheme, the optimal power rating design rule according to equalization time and SOC distribution of imbalance is proposed. A prototype of HEV lithium-ion battery system of four cells shows the outstanding charge equalization performance while maintaining greatly reduced size of cell balancing circuit.

  • PDF

식물 잎을 이용한 중금속 이온의 제거에 관한 연구 (Removal of Heavy Metal Ions from Aqueous Solution by Leaves)

  • 김종규;이장훈;이수영;나경원;나규환;최한영
    • 환경위생공학
    • /
    • 제24권2호
    • /
    • pp.31-39
    • /
    • 2009
  • In this research, I carried out the adsorption and removal test of Pb, Ni, Co and Cu ions using organic substances spread out any where in the nature which can be obtained easily from our neighbor-such as Paulownia coreana, Pinus densiflora, Juniperus chinesis, Quercus dentata, Magnolia kobus, Platanus occidentalis, Gingko biloba, Diospyros kaki leaves. As the result of the research to find the best optional condition for the adsorption and removal, shows that the adsorption and removal ratio of Pb ion by a Paulownia coreana raw leaves is 99% at $70^{\circ}C$, those of Ni ion and Co ion by Magnolia kobus formalin treatment leaves are 79% at $70^{\circ}C$, 97% at $40^{\circ}C$ respectively. And that of Cu ion by Platanus occidentalis treatment leaves is 97% at $50^{\circ}C$ in mixed solution. As the result of comparing the removal ratio by raw leaves and formalin treatment leaves, the removal ratio of treatment is 30~90% more effective than raw leaves in most cases. And I concluded Pb > Cu > Co > Ni ion in multiple solution and Co > Ni > Cu >Pb ion in single solution after testing adsorption and removal ratio of mixed solution separately as time goes by. In general, the reactions were completed within first 5 minutes. The test result of measuring the hydrolysable tannin content of each leaf shows that an overcup Quercus dentata is 11.36%, a Diospyros kaki is 10.81% and the rest of them are 2.49~4.12% in raw leaves cases. In treatment leaves cases, an overcup Quercus dentata is 3.23% and the others are less than 1%.

High-$T_c$ SQUID Application for Roll to Roll Metallic Contaminant Detector

  • Tanaka, S.;Kitamura, Y.;Uchida, Y.;Hatsukade, Y.;Ohtani, T.;Suzuki, S.
    • Progress in Superconductivity
    • /
    • 제14권2호
    • /
    • pp.82-86
    • /
    • 2012
  • A sensitive eight-channel high-Tc Superconducting Interference Device (SQUID) detection system for magnetic contaminant in a lithium ion battery anode was developed. Finding ultra-small metallic foreign matter is an important issue for a manufacturer because metallic contaminants carry the risk of an internal short. When contamination occurs, the manufacturer of the product suffers a great loss from recalling the tainted product. Metallic particles with outer dimensions smaller than 100 microns cannot be detected using a conventional X-ray imaging system. Therefore, a highly sensitive detection system for small foreign matter is required. We have already developed a detection system based on a single-channel SQUID gradiometer and horizontal magnetization. For practical use, the detection width of the system should be increased to at least 65 mm by employing multiple sensors. In this paper, we present an 8-ch high-Tc SQUID roll-to-roll system for inspecting a lithium-ion battery anode with a width of 65 mm. A special microscopic type of a cryostat was developed upon which eight SQUID gradiometers were mounted. As a result, small iron particles of 35 microns on a real lithium-ion battery anode with a width of 70 mm were successfully detected. This system is practical for the detection of contaminants in a lithium ion battery anode sheet.

A Surface Modification of Hastelloy X by Sic Coating and Ion Beam Mixing for Application in Nuclear Hydrogen Production

  • Kim, Jaeun;Park, Jaewon;Kim, Minhwan;Kim, Yongwan
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.205.2-205.2
    • /
    • 2014
  • The effects of ion beam mixing of a SiC film coated on super alloys (hastelloy X substrates) were studied, aiming at developing highly sustainable materials at above $900^{\circ}C$ in decomposed sulfuric acid gas (SO2/SO3/H2O) channels of a process heat exchanger. The bonding between two dissimilar materials is often problematic, particularly in coating metals with a ceramics protective layer. A strong bonding between SiC and hastelloy X was achieved by mixing the atoms at the interface by an ion-beam: The film was not peeled-off at ${\geq}900^{\circ}C$, confirming excellent adhesion, although the thermal expansion coefficient of hastelloy X is about three times higher than that of SiC. Instead, the SiC film was cracked along the grain boundary of the substrate at above $700^{\circ}C$. At ${\geq}900^{\circ}C$, the film was crystallized forming islands on the substrate so that a considerable part of the substrate surface could be exposed to the corrosive environment. To cover the exposed areas and cracks multiple coating/IBM processes have been developed. An immersion corrosion test in 80% sulfuric acid at $300^{\circ}C$ for 100 h showed that the weight retain rate was gradually increased when increasing the processing time.

  • PDF

Single Ion Exchange Process에 의한 LCD용 기판유리의 강화 (Strengthening of Substrate Glass for LCD by Single ton Exchange Process)

  • 이회관;오영석;이용수;강원호
    • 한국세라믹학회지
    • /
    • 제39권7호
    • /
    • pp.675-679
    • /
    • 2002
  • 강화유리를 제조하기 위해서, 디스플레이 기판으로 사용되는 soda-lime-silicate 유리를 대상으로 단일이온교환 특성에 대하여 3점곡강도와 잔류응력을 조사하였다. 단일이온교환을 47$0^{\circ}C$에서 1시간 처리 후, 45$0^{\circ}C$에서 24시간 행하였을 때, 62.5$\times$10$_{6}$ kg/$m^2$의 최대 강도 값을 나타내었다. 또한, 곡강도 측정 후 얻어진 시편의 파단면에 존재하는 잔류응력층을 파괴분석을 통하여 관찰한 결과, 이 잔류응력층이 외부하중에 대한 탄성 변형에너지를 흡수하여 유연성을 증가시킴을 알 수 있었다 또한, 탄성변형에너지 흡수는 만곡변화, 균열가지수 및 취성특성 분석에서도 관찰되었다.

병렬 연결된 리튬이온전지 셀의 비파괴 전기화학적 열화상태 진단 (Degradation diagnosis of parallel-connected lithium-ion battery cells via non-constructive electrochemical approach)

  • 이가람;정지윤;김용태;최진섭
    • 한국표면공학회지
    • /
    • 제55권4호
    • /
    • pp.231-235
    • /
    • 2022
  • As environmental pollution becomes more serious, the demand for electric vehicles (EVs) and lithium-ion batteries for electric vehicles is rapidly increasing worldwide. Accordingly, the amount of waste batteries is also increasing, and a technology for recycling and reusing them is required. In order to reuse a used battery, it is necessary to non-destructively diagnose the deterioration condition of the battery. Therefore, in this study, we investigate the diagnosis of degradation for parallel-connected lithium-ion battery cells through non-constructive electrochemical approach. As the number of parallel-connected cells increased, in addition to linear degradation, abrupt step-like degradation occurred, which is attributed to the predominant degradation of specific cells. In addition, it is confirmed that deteriorated cells among multiple cells can be distinguished through a simple measurement of open circuit voltage (OCV).

LC/MS/MS를 이용한 sildenafil 및 그 유사체 분석 (Analysis of Sildenafil and its Analogues by LC/MS/MS)

  • 명승운;박서희;조현우
    • 분석과학
    • /
    • 제16권6호
    • /
    • pp.488-498
    • /
    • 2003
  • LC/MS/MS를 이용하여 발기부전 (impotence) 치료제인 sildenafil 및 유사체인 homosildenafil, vardenafil, tadalafil을 분석하는 방법을 확립하였다. 이온화 방법으로는 electrospray ionization (ESI)와 atmospheric pressure chemical ionization (APCI) 방법을 사용하였으며 최대 감도와 재현성을 나타내는 조건을 찾기 위하여 여러 가지 파라미터를 변화시켜서 비교하였다. MRM (multiple reaction monitoring)을 위한 적절한 생성이온 (product ion)을 얻기 위하여 ESI 방법에서는 capillary voltage, cone voltage, extractor, entrance, RF lens를 변화시켰으나 전구이온 (precursor ion)을 제외한 뚜렸한 토막이온 (fragment ion)은 생성되지 않았다. 한편, APCI 방법의 경우 entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, desolvation gas를 변화시켰을 때 다른 파라미터들의 변화에 따른 전구이온을 제외한 product ion 생성 패턴의 변화는 감지되지 않고 단지 RF lens 조건의 변화에서 precursor ion을 비롯한 토막이온들의 생성과 더불어 S/N의 증가로 인한 검출 한계의 향상이 나타났다. HPLC에서의 최적 분리 조건과 질량 분석기에서 최대 감도를 나타내는 이동상 조건도 조사되었는데 10 mM ammonium formate (pH 4.8):acetonitrile=70:30 의 등용매 용리조건이 좋은 감도를 나타내었으며, 최적의 방법인 ESI-MRM 방법에서 검출한계 (S/N>5)는 sildenafil은 $0.10{\mu}g/mL$, homosildenafil은 $0.025{\mu}g/mL$, vardenafil은 $0.025{\mu}g/mL$ 그리고 tadalafil은 $0.25{\mu}g/mL$이었다.