• Title/Summary/Keyword: Multiple-ion

Search Result 295, Processing Time 0.026 seconds

Characterization of Concentrations of Fine Particulate Matter in the Atmosphere of Pohang Area (포항지역 대기 중 초미세먼지(PM$_{2.5}$)의 오염특성평가)

  • Baek, Sung-Ok;Heo, Yoon-Kyeung;Park, Young-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.302-313
    • /
    • 2008
  • The purposes of this study are to investigate the concentration levels of fine particles, so called PM$_{2.5}$, to identify the affecting sources, and to estimate quantitatively the source contributions of PM$_{2.5}$. Ambient air sampling was seasonally carried out at two sites in Pohang(a residential and an industrial area) during the period of March to December 2003. PM$_{2.5}$ samples were collected by high volume air samplers with a PM$_{10}$ Inlet and an impactor for particle size segregation, and then determined by gravimetric method. The chemical species associated with PM$_{2.5}$ were analyzed by inductively coupled plasma spectrophotometery(ICP) and ion chromatography(IC). The results showed that the most significant season for PM$_{2.5}$ mass concentrations appeared to be spring, followed by winter, fall, and summer. The annual mean concentrations of PM$_{2.5}$ were 36.6 $\mu$g/m$^3$ in the industrial and 30.6 $\mu$g/m$^3$ in the residential area, respectively. The major components associated with PM$_{2.5}$ were the secondary aerosols such as nitrates and sulfates, which were respectively 4.2 and 8.6 $\mu$g/m$^3$ in the industrial area and 3.7 and 6.9 $\mu$g/m$^3$ in the residential area. The concentrations of chemical component in relation to natural emission sources such as Al, Ca, Mg, K were generally higher at both sampling sites than other sources. However, the concentrations of Fe, Mn, Cr in the industrial area were higher than those in the residential area. Based on the principal component analysis and stepwise multiple linear regression analysis for both areas, it was found that soil/road dust and secondary aerosols are the most significant factors affecting the variations of PM$_{2.5}$ in the ambient air of Pohang. The source apportionments of PM$_{2.5}$ were conducted by chemical mass balance(CMB) modeling. The contributions of PM$_{2.5}$ emission sources were estimated using the CMB8.0 receptor model, resulting that soil/road dust was the major contributor to PM$_{2.5}$, followed by secondary aerosols, vehicle emissions, marine aerosols, metallurgy industry. Finally, the application and its limitations of chemical mass balance modeling for PM$_{2.5}$ was discussed.

Studies on Nutrio-physiological Response of Rice Plant to Root Environment (근부환경(根部環境)에 따른 수도(水稻)의 영양생리적(營養生理的) 반응(反應)에 관(關)한 연구(硏究))

  • Park, J.K.;Kim, Y.S.;Oh, W.K.;Park, H.;Yazawa, F.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.2 no.1
    • /
    • pp.53-68
    • /
    • 1969
  • The nutriophysiological response of rice plant to root environment was investigated with eye observation of root development and rhizosphere in situation. The results may be summarized as follows: 1) The quick decomposition of organic matter, added in low yield soil, caused that the origainal organic matter content was reached very quickly, in spite of it low value. In high yield soil the reverse was seen. 2) In low yield soil root development, root activity and T/R value were very low, whereas addition of organic matter lowered them still wore. This might be contributed to gas bubbles around the root by the decomposition of organic matter. 3) Varietal difference in the response to root environment was clear. Suwon 82 was more susceptible to growth-inhibitine conditions on low-yield soil than Norin 25. 4) Potassium uptake was mostly hindered by organic matter, while some factors in soil hindered mostly posphorus uptake. When the organic matter was added to such soil, the effect of them resulted in multiple interaction. 5) The root activity showed a correlation coeffieient of 0.839, 0.834 and 0.948 at 1% level with the number of root, yield of aerial part and root yield, respectively. At 5% level the root-activity showed correlation-coefficient of 0.751, 0.670 and 0.769 with the uptake of the aerial part of respectively. N, P and K and a correlation-coefficient of 0.729, 0.742 and 0.815 with the uptake of the root of respectively N.P. and K. So especially for K-uptake a high correlation with the root-activity was found. 6) The nitrogen content of the roots in low-yield soil was higher than in high-yield soil, while the content in the upper part showed the reverse. It may suggest ammonium toxicity in the root. In low-yield soil Potassium and Phosphorus content was low in both the root and aerial part, and in the latter particularly in the culm and leaf sheath. 7) The content of reducing sugar, non-recuding sugar, starh and eugar, total carbohydrates in the aerial part of plants in low yield soil was higher than in high yield soil. The content of them, especially of reducing sugar in the roots was lower. It may be caused by abnormal metabolic consumption of sugar in the root. 8) Sulfur content was very high in the aerial part, especially in leaf blade of plants on low yield soil and $P_2O_5/S$ value of the leaf blade was one fifth of that in high yield soil. It suggests a possible toxic effect of sulfate ion on photophosphorization. 9) The high value of $Fe/P_2O_5$ of the aerial part of plants in low yield soil suggests the possible formation of solid $Fe/PO_4$ as a mechanical hindrance for the translocation of nutrients. 10) Translocation of nutrients in the plant was very poor and most nutrients were accumulated in the root in low yield soil. That might contributed to the lack of energy sources and mechanical hindrance. 11) The amount of roots in high yield soil, was greater than that in low yield soil. The in high-yield soil was deep, distribution of the roots whereas in the low-yield soil the root-distribution was mainly in the top-layer. Without application of Nitrogen fertilizer the roots were mainly distributed in the upper 7cm. of topsoil. With 120 kg N/ha. root were more concentrated in the layer between 7cm. and 14cm. depth. The amount of roots increased with the amount of fertilizer applied.

  • PDF

Development and Validation of Analytical Method for Determination of Fungicide Spiroxamine Residue in Agricultural Commodities Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 Spiroxamine의 시험법 개발 및 검증)

  • Park, Shin-Min;Do, Jung-Ah;Lim, Seung-Hee;Yoon, Ji-Hye;Pak, Won-Min;Shin, Hye-Sun;Kuk, Ju-Hee;Chung, Hyung-Wook
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.4
    • /
    • pp.296-305
    • /
    • 2018
  • Spiroxamine, one of fungicides, is used to control powdery mildew in various crops and black yellow sigatoka in bananas. The major strength of spiroxamine is to control powdery mildew in various crops and bananas yellow sigatoka in bananas. The compound has shown a high level of activity, good persistence and crop tolerance. Besides powdery mildew, good control of rust, net blotch and Rhynchosporium diseases been indicated in cereals, together with a complementary activity against Septoria diseases. In 2017, the maximum residue limit (MRL) of spiroxamine established in Korea. According to Ministry of ood and rug afety) regulations, spiroxamine residues defined only parent compound. Thus, a analytical method is needed to estimate the residue level of the parent compound. The objective of this study was to develop and validate analytical method for spiroxamine in representative agricultural commodities. Samples were extracted with acetonitrile and partitioned with dichloromethane to remove the interfering substances. The analyte were quantified and confirmed liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive-ion mode using multiple reaction monitoring (MRM). Matrix matched calibration curves were linear over the calibration ranges ($0.0005{\sim}0.1{\mu}g/mL$) for the analyte in blank extract with coefficient of determination ($r^2$) > 0.99. For validation purposes, recovery studies will be carried out at three different concentration levels (LOQ, 10LOQ, and 50LOQ) performing five replicates at each level. The recoveries 70.6~104.6% with relative standard deviations (RSDs) less than 10%. All values were consistent with the criteria ranges in the Codex guidelines (CAC/GL40, 2003) and MFDS guidelines. proposed analytical method be used as an official analytical method in the Republic of Korea.

A Study in an Effective Programs for Emergency Care Delivery System (응급의료 전달체계의 충실 방안)

  • Kwon Sook Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.9 no.1
    • /
    • pp.83-102
    • /
    • 1995
  • As the society is being industrialized, the fast-paced economic development that has caused substantial increase in cerebrovascular and coronary artery diseases and the industrial development and increased use of means of transportation have resulted in the rapid rise of incidents in external injuries as well. So the pubic has become acutely aware of the need for fast and effective emergency care delivery system. The goal of emergency care delivery system is to meet the emergency care needs of patients. The emergency care delivery system is seeking to efficiently satisfy the care needs of people. Therefore the purpose of this study is designed to develop an effective programs for emergency care delivery system in Korea. The following specific objectives were investigated. This emergency care delivery system must have the necessary man power, for transfering the patients, communication net work, and emergency care facilities. 1) Man power Emergency care requires n0t only specialized traning in the emergency treatment but also knowledge and experience i11 other related area, so emergency care personnel traning program should be designed in order to adapt to the specific need of emergency patients. It will be necessary to ensure professional personnel who aquires the sufficient traning and experience for emergency care and to look for legal basis. We have to develop re-educational programs for emergency nurse specialist. They should be received speciality of emergency nursing care so that they will work actively and positively in emergency part. Emergency medical doctor and nurse specialist should be given an education which is related in emergency and critical care. Emergency care personnel will continue to provide both acute and continuing care as partner with other medical team. 2) Transfering the patients. Successful management of pre-hospital care requires adequate traning for the emergency medical technician. Traning program should be required to participate in a actual first aids activites in order to have apportunities to acquire practical skills as well as theoretical knowledge. The system of emergency medical technician should be remarkablly successful with first responder firefighters. Establishing this system must add necessary ambulances operating at any given time. It will be necessary to standardize the ambulance size and equipment. Ambulance should be arranged with each and every fire station. 3) Communication net work. The head office of emergency commumication network should be arranged with the head office of fire station in community. It is proposed that Hot-line system for emergency care should be introduce. High controlled ambulance and thirtial emergency center should simultaneously equip critical-line in order to communication with each other. Ordinary ambulance and secondary emergency facility should also simultaneously equip emergency-line in order to communication with each other. 4) Emergency care facilities. Primary emergency care facilities should be covered with the ambulatory emergency patients-minor illness and injuires. Secondary emergency care facilities should be covered with the emergency admission patients. Third emergency care center should be covered with the critical patients who need special treatments and operation. Secondary and third emergency care facilities should employ emergency medical doctor and emergency nurse specialist to treat in-patients with severe and acute illness and multiple injuires. It should be fashioned for a system of emergency facilities that meets emergency patients needs. Provide incentives for increased number of emergency care facilities with traning in personal/clinical emergency care. 5) Finance It is recommended to put the finance of a emergency care on a firm basis. The emergency care delivery system should be managed by the government or accreditted organizations. In order to facilitate this relevant program the fund is needed for more efficient and effective emergency researchs, service, programs, and policy. 6) Gaining understanding and co-operation of pubic It is also important to undertake pubic education to improve understanding of first aids and C. P. R of individuals, communities and business. It is proposed that teachers and health officers be certified in C. P. R. The C. P. R education can be powerful influence save lives. Lastly appropriate emergency care information must be provided to the pubic for assisting them in choosing emergency care.

  • PDF

Development of analytical method for determination of spinetoram residues in livestock using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 Spinetoram 공정시험법 개발 및 검증)

  • Ko, Ah-Young;Kim, Heejung;Do, Jung Ah;Jang, Jin;Lee, Eun Hyang;Ju, Yun Ji;Kim, Ji Young;Chang, Moon-Ik;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.94-103
    • /
    • 2016
  • An analytical method was developed to determine the amount of spinetoram (spinetoram J and spinetoram L) in livestock samples. The spinetoram was extracted with acetonitrile and purified through a primary secondary amine (PSA) sorbent. The spinetoram residues were then quantified and confirmed using a liquid chromatography–tandem mass spectrometer (LC-MS/MS) in the positive ion mode using multiple reactions monitoring (MRM). Matrix-matched calibration curves were linear over the calibration ranges (0.005-0.5 mg/kg) into a blank extract with r2 > 0.994. The limits of detection and quantification were 0.002 and 0.01 mg/kg, respectively. The recovery results of spinetram ranged between 81.9-106.4% at different concentration levels (LOQ, 10LOQ, 50LOQ, n=5) with relative standard deviations (RSDs) less than 10%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL40, 2003). An interlaboratory study was conducted to validate the method. The proposed analytical method proved to be accurate, effective, and sensitive for spinetoram determination. The method will be used as an official analytical method in Korea.

Development of Simultaneous Analytical Method for Determination of Isoxaflutole and its Metabolite (Diketonitrile) residues in Agricultural Commodities Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Isoxaflutole과 대사산물(Diketonitrile)의 동시시험법 개발)

  • Ko, Ah-Young;Kim, Heejung;Do, Jung Ah;Jang, Jin;Lee, Eun-Hyang;Ju, Yunji;Kim, Ji Young;Chang, Moon-Ik;Rhee, Gyu-Seek
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.2
    • /
    • pp.93-103
    • /
    • 2016
  • A simultaneous analytical method was developed for the determination of isoxaflutole and metabolite (diketonitrile) in agricultural commodities. Samples were extracted with 0.1% acetic acid in water/acetonitrile (2/8, v/v) and partitioned with dichloromethane to remove the interference obtained from sample extracts, adjusting pH to 2 by 1 N hydrochloric acid. The analytes were quantified and confirmed via liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive-ion mode using multiple reaction monitoring (MRM). Matrix matched calibration curves were linear over the calibration ranges ($0.02-2.0{\mu}g/mL$) for all the analytes into blank extract with $r^2$ > 0.997. For validation purposes, recovery studies were carried out at three different concentration levels (LOQ, 10LOQ, and 50LOQ) performing five replicates at each level. The recoveries were ranged between 72.9 to 107.3%, with relative standard deviations (RSDs) less than 10% for all analytes. All values were consistent with the criteria ranges requested in the Codex guideline (CAC/GL40, 2003). Furthermore, inter-laboratory study was conducted to validate the method. The proposed analytical method was accurate, effective, and sensitive for isoxaflutole and diketonitrile determination in agricultural commodities.

Film Dosimetry for Intensity Modulated Radiation Therapy : Dosimetric Evaluation (필름을 사용한 세기변조치료법에 대한 선량측정)

  • Ju Sang Gyu;Yeo Inhwan Jason;Huh Seung Jae;Choi Byung Ki;Park Young Hwan;Ahn Yong Chan;Kim Dae Yong;Kong Young Kun
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.172-178
    • /
    • 2002
  • Purpose : X-ray film over responds to low-energy photons in relative photon beam dosimetry because its sensor is based on silver bromide crystals, which are high-Z molecules. This over-response becomes a significant problem in clinical photon beam dosimetry particularly in regions outside the penumbra. In intensity modulated radiation therapy (IMRT), the radiation field is characterized by multiple small fields and their outside-penumbra regions. Therefore, in order to use film dosimetry for IMRT, the nature the source of the over-response in its radiation field need to be known. This study is aimed to verify and possibly improve film dosimetry for IMRT. Materials and Method : Modulated beams were constructed by a combination of five or seven different static radiation fields using 6 MeV X-rays. In order to verify film dosimetry, we used X-ray film and an ion chamber were used to measure the dose profiles at various depths in a phantom. In addition, in order to reduce the over-response, 0.01 inch thick lead filters were placed on both sides of the film. Results : The measured dose profiles showed a film over-response at the outside-penumbra and low dose regions. The error increased with depths and approached 15% at a maximum for the field size of $15{\times}15cm^2$ at 10 cm depth. The use of filters reduced the error to 3%, but caused an under-response of the dose in a perpendicular set-up. Conclusion : This study demonstrated that film dosimetry for IMRT involves sources of error due to its over-response to low-energy Photons. The use of filers can enhance the accuracy in film dosimetry for IMRT. In this regard, the use of optimal filter conditions is recommended.

Corrosion Characteristics of Excavated Bronze Artifacts According to Corrosion Environment (부식 환경에 따른 출토 청동 유물의 부식 특성)

  • Jang, Junhyuk;Bae, Gowoon;Chung, Kwangyong
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.1
    • /
    • pp.24-33
    • /
    • 2020
  • In excavated bronze artifacts, corrosion products of various shapes and colors are observed due to multiple corrosion factors coexisting in the burial environment, and these corrosion products can constitute important data not only in terms of long-term corrosion-related information, but also in connection with preservation of artifacts. As such, scientific analysis is being carried out on the corrosion layer and corrosion products of bronze artifacts, and the corrosion mechanism and the characteristics of corrosion products elucidated, which is essential for interpreting the exposed burial environment and its association with corrosion factors inside the burial environment. In this study, after classifying excavated bronze artifacts according to alloy ratio and fabrication technique, comprehensive analysis of the surface of corrosion artifacts, corrosion layer, and corrosion products was carried out to investigate the corrosion mechanism, formation process of the corrosion layer, and characteristics of corrosion products. The study designated two groups according to alloy ratio and fabrication technique. In Group 1, which involved a Cu-Sn-Pb alloy and had no heat treatment, the surface was rough and external corrosion layers were formed on a part, or both sides, of the inside and the outside, and the surface was observed as being green or blue. α+δ phase selection corrosion was found in the metal and some were found to be concentrated in an empty space with a purity of 95 percent or more after α+δ phase corrosion. The Cu-Sn alloy and heat-treated Group 2 formed a smooth surface with no external corrosion layer, and a dark yellow surface was observed. In addition, no external corrosion layer was observed, unlike Group 1, and α corrosion was found inside the metal. In conclusion, it can be seen that the bronze artifacts excavated from the same site differ in various aspects, including the formation of the corrosion layer, the shape and color of the corrosion products, and the metal ion migration path, depending on the alloy ratio and fabrication technique. They also exhibited different corrosion characteristics in the same material, which means that different forms of corrosion can occur depending on the exposure environment in the burial setting. Therefore, even bronze artifacts excavated from the same site will have different corrosion characteristics depending on alloy ratio, fabrication technique, and exposure environment. The study shows one aspect of corrosion characteristics in specific areas and objects; further study of corrosion mechanisms in accordance with burial conditions will be required through analysis of the corrosive layer and corrosive product characteristics of bronze artifacts from various regions.

Synthesis and Structural Characterization of Benzene-sorbed Cd2+-Y(FAU) Zeolite (벤젠이 흡착된 Cd2+-Y(FAU) 제올라이트의 합성 및 구조연구)

  • Moon, Dae Jun;Suh, Jeong-Min;Park, Jong Sam;Choi, Sik Young;Lim, Woo Taik
    • Journal of the Mineralogical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.45-57
    • /
    • 2017
  • Two single crystals of fully dehydrated $Cd^{2+}$-exchanged zeolites Y were prepared by the exchange of ${\mid}Na_{75}{\mid}[Si_{117}Al_{75}O_{384}]-FAU$ ($Na_{75}-Y$, Si/Al = 1.56) with aqueous $0.05M\;Cd(NO_3)_2$ (pH = 3.65) at 294 K, followed by vacuum dehydration at 723 K (crystal 1) and a second crystal, similarly prepared, was exposed to zeolitically dried benzene for 72 hours at 294 K and evacuated (crystal 2). Their structures were determined crystallographically using synchrotron X-rays and were refined to the final error indices using $F_o$>$4{\sigma}(F_o)$ of $R_1/wR_2=0.040/0.121$ and 0.052/0.168, respectively. In crystal $1({\mid}Cd_{36}H_3{\mid}[Si_{117}Al_{75}O_{384}]-FAU)$, $Cd^{2+}$ ions primarily occupy sites I and II, with additional $Cd^{2+}$ ions at sites I', II', and a second site II. In crystal $2({\mid}Cd_{35}(C_6H_6)_{24}H_5{\mid}[Si_{117}Al_{75}O_{384}]-FAU)$, $Cd^{2+}$ ions occupy five crystallographic sites. The 24 benzene molecules are found at two distinct positions within the supercages. The 17 benzene molecules are found on the 3-fold axes in the supercages where each interacts facially with one of site IIa $Cd^{2+}$ ions. The remaining 7 benzene molecules lie on the planes of the 12-rings where each is stabilized by multiple weak electrostatic and van der Waals interactions with framework oxygens.

Objective Analysis of the Set-up Error and Tumor Movement in Lung Cancer Patients using Electronic Portal Imaging Device (폐암 환자에서 Electronic Portal Imaging Device를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Kim, Woo-Cheol;Chung, Eun-Ji;Lee, Chang-Geol;Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.69-76
    • /
    • 1996
  • Purpose : The aim of this study is to investigate the random and systematic errors and tumor movement using electronic portal imaging device in lung cancer patients for the adequate margin in the treatment planning of 3-dimensional conformal therapy. Material and Methods : The electronic portal imaging device is matrix ion chamber type(Portal Vision, Varian). Ten patients of lung cancer treated with chest irradiation were selected for this study. Patients were treated in the supine position without immobilization device. All treatments were delivered by an 10 MV linear accelerator that had the portal imaging system mounted to its ganrty. AP or PA field Portal images were only analyzed. Radiation therapy field included the tumor, mediastinum and supraclavicular lymph nodes. A total of 103 portal images were analyzed for set-up deviation and 10 multiple images were analyzed for tumor movement because of respiration and cardiac motion. Result : The average values of setup displacements in the x, y direction was 1.41 mm, 1 78 mm, respectively. The standard deviation of systematic component was 4.63 mm, 4.11 mm along the x, y axis, respectively while the random component was 4.17 mm in the x direction and 3.31 mm in the y direction. The average displacement from respiratory movement was 12.2 mm with a standard deviation of 4.03 mm. Conclusion : The overall set-up displacement includes both random and systematic component and respiratory movement. About 10 mm, 25 mm margins along x, y axis which considered the set-up displacement and tumor movement were required for initial 3-dimensional conformal treatment planning in the lung cancer patients and portal images should be made and analyzed during first week of treatment, individually.

  • PDF