• Title/Summary/Keyword: Multiple-ion

Search Result 294, Processing Time 0.024 seconds

Characteristics of single/poly crystalline silicon etching by$Ar^+$ ion laser for MEMS applications (MEMS 응용을 위한 $Ar^+$ 이온 레이저에 의한 단결정/다결정 실리콘 식각 특성)

  • Lee, Hyun-Ki;Han, Seung-Oh;Park, Jung-Ho;Lee, Cheon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.396-401
    • /
    • 1999
  • In this study, $Ar^+$ ion laser etching process of single/poly-crystalline Si with $CCl_2F_2$ gas is investigated for MEMS applications. In general, laser direct etching process is useful in microelectronic process, fabrication of micro sensors and actuators, rapid prototyping, and complementary processing because of the advantages of 3D micromachining, local etching/deposition process, and maskless process with high resolution. In this study, a pyrolytic method, in which $CCl_2F_2$ gasetches molten Si by the focused laser, was used. In order to analyze the temperature profile of Si by the focused laser, the 3D heat conduction equation was analytically solved. In order to investigate the process parameters dependence of etching characteristics, laser power, $CCl_2F_2$ gas pressure, and scanning speed were varied and the experimental results were observed by SEM. The aspect ratio was measured in multiple scanning and the simple 3D structure was fabricated. In addition, the etching characteristics of $6\mum$ thick poly-crystalline Si on the insulator was investigated to obtain flat bottom and vertical side wall for MEMS applications.

  • PDF

Particle Simulation Modelling of a Beam Forming Structure in Negative-Ion-Based Neutral Beam Injector (중성빔 입사장치에서 빔형성 구조의 입자모사 모형)

  • Park, Byoung-Lyong;Hong, Sang-Hee
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.40-47
    • /
    • 1989
  • For the effective design of a beam forming structure of the negative-ion-based neutral beam injector, a computer program based on a particle simulation model is developed for the calculation of charged particle motions in the electrostatic fields. The motions of negative ions inside the acceleration tube of a multiple-aperture triode are computed at finite time steps. The electrostatic potentials are obtained from the Poisson's equation by the finite difference method. The successive overrelaxation method is used to solve the matrix equation. The particle and force weighting methods are used on a cloud-in-cell model. The optimum design of the beam forming structure has been studied by using this computer code for the various conditions of elctrodes. The effects of the acceleration-deceleration gap distance, the thickness of the deceleration electrode and the shape of the acceleration electrode on beam trajectories are exmined to find the minimum beam divergence. Some numerical illustrations are presented for the particle movements at finite time steps in the beam forming tubes. It is found in this particle simulation modelling that the shape of the acceleration electrode is the most significant factor of beam divergence.

  • PDF

A Disk-based Archival Storage System Using the EOS Erasure Coding Implementation for the ALICE Experiment at the CERN LHC

  • Ahn, Sang Un;Betev, Latchezar;Bonfillou, Eric;Han, Heejune;Kim, Jeongheon;Lee, Seung Hee;Panzer-Steindel, Bernd;Peters, Andreas-Joachim;Yoon, Heejun
    • Journal of Information Science Theory and Practice
    • /
    • v.10 no.spc
    • /
    • pp.56-65
    • /
    • 2022
  • Korea Institute of Science and Technology Information (KISTI) is a Worldwide LHC Computing Grid (WLCG) Tier-1 center mandated to preserve raw data produced from A Large Ion Collider Experiment (ALICE) experiment using the world's largest particle accelerator, the Large Hadron Collider (LHC) at European Organization for Nuclear Research (CERN). Physical medium used widely for long-term data preservation is tape, thanks to its reliability and least price per capacity compared to other media such as optical disk, hard disk, and solid-state disk. However, decreasing numbers of manufacturers for both tape drives and cartridges, and patent disputes among them escalated risk of market. As alternative to tape-based data preservation strategy, we proposed disk-only erasure-coded archival storage system, Custodial Disk Storage (CDS), powered by Exascale Open Storage (EOS), an open-source storage management software developed by CERN. CDS system consists of 18 high density Just-Bunch-Of-Disks (JBOD) enclosures attached to 9 servers through 12 Gbps Serial Attached SCSI (SAS) Host Bus Adapter (HBA) interfaces via multiple paths for redundancy and multiplexing. For data protection, we introduced Reed-Solomon (RS) (16, 4) Erasure Coding (EC) layout, where the number of data and parity blocks are 12 and 4 respectively, which gives the annual data loss probability equivalent to 5×10-14. In this paper, we discuss CDS system design based on JBOD products, performance limitations, and data protection strategy accommodating EOS EC implementation. We present CDS operations for ALICE experiment and long-term power consumption measurement.

The Analysis of Dioxin-like PCBs in Fishes and Shellfishes using Accelerated Solvent Extraction (ASE) System and Multilayer Column Chromatography (가속용매추출장치(ASE) 및 다층크로마토그래피를 이용한 어패류 중의 dioxin-like PCBs의 분석)

  • Oh, Keum-Soon;Park, Seong-Soo;Chung, So-Young;Sho, You-Sub;Kim, Jung-Soo;Jang, Seoung-Chul;Lee, Jong-Ok;Kim, Hee-Yun;Woo, Gun-Jo;Suh, Jung-Hyuck
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.2
    • /
    • pp.122-127
    • /
    • 2007
  • In this study, an analytical method was optimized for detecting dioxin-like PCBs in fish and shellfish. Here, homogenized samples were extracted using an accelerated solvent extraction (ASE) system with 33 mL cell size. Multilayer column chromatography, which consisted of acidic, basic and neutral silica gels, was used for the clean up of the extracts. The instrumental analysis was executed by HRGC/HRMS to a resolution of 10,000 using 4 window multiple ion detection (MID) mode. For the results, the average recoveries ranged from 94.1 to 104.1% (${\pm}8.4$) and the limit of detection was approximately 0.1 pg/g at S/N ratio >3. Finally, the detected concentrations of dioxin-like PCBs for fish and shellfish were in the range of 0.030-1.836 pg TEQ/g.

Estimation of deep reservoir temperature of thermal groundwaters in Bugok and Magumsan areas, South Korea

  • Park, Seong-Sook;Yun, Seong-Taek;So, Chil-Sup
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.473-476
    • /
    • 2004
  • In this study, hydrochemical studies of thermal waters in the Bugok and Magumsan areas showing geothermal anomalies were carried, and the applicability of ion seothermometers and multiple mineral equilibrium approach was examined to estimate their potential deep reservoir temperatures. Typical thermal waters of the two areas are clearly grouped into two major types, according to water chemistry: Na-Cl type (group A) and Na-SO4 type (group D). Compared to group A, group B and C waters show some modifications in chemistry. Group E waters show the modified chemistry from group D. Geothermal waters from the two areas showed some different chemical characteristics. The thermal waters of group A and B in Magumsan area are typically neutral to alkaline (pH=6.7 to 8.1) and Cl-rich (up to 446.1 mg/L), while the waters of group D and E in Bugok area are alkaline (pH=7.6 to 10.0) and SO$_4$-rich (up to 188.0 mg/L). The group A (Na-Cl type) and group D (Na-SO$_4$ type) waters correspond to mature or partially immature water, whereas the other types are immature water. The genesis of geothermal waters are considered as follows: group A and B waters were formed by seawater infiltration into reservoir rocks along faults and fracture zones and possibly affected by fossil connate waters in lithologic units through which deep hot waters circulate; on the other hand, group D and E waters were formed by the oxidation of sulfide minerals (mainly pyrite) in surrounding sedimentary rocks and/or hydrothermal veins occurring along restricted fracture channels and were possibly affected by the input and subsequent oxidation of S-bearing gases (e.g. H2S) from deep thermal reservoir (probably, cooling pluton). The application of quartz, Na-K, K-Mg geothermometers to the chemistry of representative group A and D waters yielded a reasonable temperature estimate (99-147$^{\circ}C$ and 90-142$^{\circ}C$) for deep geothermal reservoir. Aqueous liquid-rich fluid inclusions in fracture calcites obtained from drillcores in Bugok area have an average homogenization temperature of 128$^{\circ}C$, which corresponds to the results from ion geothermometers. The multiple mineral equilibrium approach yielded a similar temperature estimate (105-135$^{\circ}C$ and 100-14$0^{\circ}C$). We consider that deep reservoir temperatures of thermal waters in the Magumsan and Bugok areas can be estimated by the chemistry of typical Na-Cl and Na-SO$_4$ type waters and possibly approach 105-135$^{\circ}C$ and 100-14$0^{\circ}C$.

  • PDF

Determination of Inorganic Phosphate in Paprika Hydroponic Solution using a Laboratory-made Automated Test Stand with Cobalt-based Electrodes (코발트전극과 자동시험장치를 이용한 파프리카 양액 내 무기인산 측정)

  • Kim, Hak-Jin;Son, Dong-Wook;Kwon, Soon-Goo;Roh, Mi-Young;Kang, Chang-Ik;Jung, Ho-Seop
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.326-333
    • /
    • 2011
  • The need for rapid on-site monitoring of hydroponic macronutrients has led to the use of ion-selective electrodes, because of their advantages over spectrophotometric methods, including simple methodology, direct measurement of analyte, sensitivity over a wide concentration range, and low cost. Stability and repeatability of response can be a concern when using multiple ion-selective electrodes to measure concentrations in a series of samples because accuracy might be limited by drifts in electrode potential. A computer-based measurement system could improve accuracy and precision because of both consistent control of sample preparation and easy calibration of sensors. Our goal was to investigate the applicability of a cobalt-based electrode used in conjunction with a laboratory-made automated test stand for quantitative determination of ${PO_4}^-$ in hydroponic solution. Six hydroponic solutions were prepared by diluting highly concentrated paprika hydroponicsolution to provide a concentration range of 1 to 300 ppm $PO_4$-P. A calibration curve relating electrode response to phosphate in paprika hydroponic solution titrated to pH 4 with 0.025M KHP was developed based on the Nikolskii-Eisenman equation with a coefficient of determination ($R^2$) of 0.94. The laboratory-made test stand consisting of three cobalt-based electrodes measured phosphate concentrations similar to those obtained with standard laboratory methods (a regression slope of 0.98 with $R^2$ = 0.80). However, the y intercept was relatively high, 30 ppm, probably due to the relatively large amount of variation present among multiple measurements of the same sample. Further studies on the high variation in EMFs obtained with cobalt electrodes during replicate measurements were required for P estimations comparable to those obtained with standard laboratory instruments.

The Improved Method for Precise Determination of Pu Isotope Ratio using MC-ICP-MS (다중검출기유도결합플라즈마질량분석기를 이용한 Pu 동위원소비 정밀 분석법)

  • Yim, Seong-A;Han, Eun-Mi;Chae, Jung-Seok;Yun, Ju-Young
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.117-123
    • /
    • 2010
  • Plutonium is by far the most important of the transuranic elements which have been released into the environment due to radio-toxicity and long term radiation effects on humans. And Pu isotope ratio ($^{240}Pu/^{239}Pu$) is of great interest because this ratio is used as a fingerprint for different sources. Mass spectrometry has been used as an useful atom counting technique with several advantages over decay counting techniques for the determination of Pu isotopes. It enables a determination of Pu isotope ratio in the environmental samples with a low detection limit and a short determination time. An ICP-MS is the representative mass spectrometry for Pu determination. In this study, the precision of $^{240}Pu/^{239}Pu$ isotope ratio was improved by using 4 multiple ion counters of MC-ICP-MS. The detection limit of $^{239}Pu$ and $^{240}Pu$ were $0.10\;fg\;ml^{-1}$ ($0.24\;{\mu}Bq\;ml^{-1}$), $0.12\;fg\;ml^{-1}$ ($0.97\;{\mu}Bq\;ml^{-1}$), respectively. The relative standard deviation of $^{240}Pu/^{239}Pu$ isotope ratio was less than 1 % in trace level. The various reference materials (seawater, soil and sediment) were analyzed to verify this method and their analytical results were in good agreement with the certified (or recommended value) value.

Histological Change of Uterus Endometrium and Expression of the Eggshell-related Genes according to Hen Age (닭의 산란연령에 따른 자궁내막조직의 변화 및 난각 관련 유전자의 발현양상)

  • Park, Ji Ae;Cho, Eun Jung;Park, Jung Yeon;Sohn, Sea Hwan
    • Korean Journal of Poultry Science
    • /
    • v.44 no.1
    • /
    • pp.19-28
    • /
    • 2017
  • The eggshell is an intricate and highly ordered structure composed of multiple layers and a calcified matrix. The eggshell is formed at the uterine segment of the chicken oviduct. In this study, histological changes in the uterine endometrium and the expression of the eggshell-related genes were investigated according to hen age. We analyzed the expression of eggshell protein-related genes, such as OCX-32, OCX-36, OC-17, OC-116, and eggshell-ion-related genes, such as CABL-1, SPP1, SCNN1G, ATP2A2, CA2, and CALM1. In chicken uterine endometrium, histological deformation, fibrosis, atrophy and elimination of micro-villi were found with increasing hen age. The concentration of blood-ion components did not significantly change with age. The amount of telomeric DNA in uterine endometrial cells decreased with increasing hen age. The expression of most of the eggshell-related genes changed significantly with increasing hen age. The expression of some ovo-proteins, which play a role in eggshell formation, increased with increasing hen age; however, there were no significant correlations among eggshell protein genes. Eggshell ion-related genes, such as ATP2A2, SCNN1G, CA2, and CALM1, were closely related to each other. The OCX-32 and OCX-36 genes were closely related to some of the eggshell ion genes. Eggshell protein-related genes, such as the OCX-32, OCX-36 genes and ion-related genes such as CALB-1, ATP2A2, SCNN1G, CA2, CALM1, affected eggshell formation, mutually or independently. This study shows that, uterine although endometrial cell damage occurs with increasing hen age, normal eggshells can be formed in old hens. This suggests that eggshell protein-and eggshell ion-related genes also control the homeostasis of eggshell formation.

Immunochemical Studies for the Characterization of Purified $(Na^+,\;K^+)-ATPase$ and Its Subunits with a Special Reference of Their Effect on Monovalent Cation Transport in Reconstituted $(Na^+,\;K^+)-ATPase$ Vesicles

  • Rhee, H.M.;Hokin, L.E.
    • The Korean Journal of Pharmacology
    • /
    • v.26 no.1
    • /
    • pp.35-49
    • /
    • 1990
  • A highly purified $(Na^+,\;K^+)-ATPase$ from the rectal gland of Squalus acanthias and from the electric organ of Electrophorus electricus has been used to raise antibodies in rabbits. The 97,000 dalton catalytic subunit and glycoprotein derived from the rectal gland of spiny shark were also used as antigens. The two $(Na^+,\;K^+)-ATPase$ holoenzymes and the two shark subunits were antigenic. In Ouchterlony double diffusion experiments, these antibodies formed precipitation bands with their antigens. Antibodies prepared against the two subunits of shark holoenzyme also formed precipitation bands with their antigens and shark holoenzyme, but not with eel holoenzyme. These observations are in good agreement with inhibitory effect of these antibodies on the catalytic activity of $(Na^+,\;K^+)-ATPase$ both from the shark and the eel, since there is very little cross-reaction between the shark anticatalytic subunit antibodies and the eel holoenzyme. The maximum antibodies titer of the anticatalytic subunit antibodies is found to be 6 weeks after the initial single exposure to this antigen. Multiple injections of the antigen increased the antibody titer. However, the time required to produce the maximum antibody titer was approximately the same. These antibodies also inhibit catalytic activity of $(Na^+,\;K^+)-ATPase$ vesicles reconstituted by a slow dialysis of cholate after solubilization of the enzyme in a presonicated mixture of cholate and phospholipid. In these reconstituted $(Na^+,\;K^+)-ATPase$ vesicles, effects of these antibodies on the fluxes of $Na^+$, $Rb^+$, and $K^+$ were investigated. Control or preimmune serum had no effect on the influx of $^{22}Na^+$ or the efflux of $^{86}Rb^+$. Immunized sera against the shark $(Na^+,\;K^+)-ATPase$ holoenzyme, its glycoprotein or catalytic subunit did inhibit the influx of $^{22}Na^+$ and the efflux of $^{86}Rb^+$. It was also demonstrated that these antibodies inhibit the coupled counter-transport of $Na^+$ and $K^+$ as studied by means of dual labeling experiments. However, this inhibitory effect of the antibodies on transport of ions in the $(Na^+,\;K^+)-ATPase$ vesicles is manifested only on the portion of energy and temperature dependent alkali metal fluxes, not on the portion of ATP and ouabain insensitive ion movement. Simultaneous determination of effects of the antibodies on ion fluxes and vesicular catalytic activity indicates that an inhibition of active ion transport in reconstituted $(Na^+,\;K^+)-ATPase$ vesicles appears to be due to the inhibitory action of the antibodies on the enzymatic activity of $(Na^+,\;K^+)-ATPase$ molecules incorporated in the vesicles. These findings that the inhibitory effects of the antibodies specific to $(Na^+,\;K^+)-ATPase$ or to its subunits on ATP and temperature sensitive monovalent cation transport in parallel with the inhibitory effect of vesicular catalytic activity by these antibodies provide direct evidence that $(Na^+,\;K^+)-ATPase$ is the molecular machinery of active cation transport in this reconstituted $(Na^+,\;K^+)-ATPase$ vesicular system.

  • PDF

Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity

  • Lee, Jung-Jin;Song, Kwang-Yeob;Ahn, Seung-Geun;Choi, Jung-Yun;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.172-177
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS. It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens ($10{\times}10{\times}1.5mm$) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS. The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION. The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity.