• 제목/요약/키워드: Multiple power sources

검색결과 140건 처리시간 0.037초

Development of Internal linear Inductively Coupled Plasma Sources for Large Area Flat Penal Display Processing

  • Lim, Jong-Hyeuk;Park, Jung-Kyun;Kim, Kyong-Nam;Yeom, Geun-Young
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.933-936
    • /
    • 2007
  • An inductively coupled plasma source with internaltype linear inductive antennas named as "multiple Utype antenna" was developed for the substrate size of $2,300mm\;{\times}\;2,000mm$. High density plasmas on the order of $1.18\;{\times}\;10^{11}\;cm^{-3}$ could be obtained and the RF power of 8kW with good plasma stability.

  • PDF

전기추진 항공기 설계를 위한 사이징 방법 연구 (Aircraft Sizing Methods for the Design of an Electrically Propelled Aircraft)

  • 황호연;남태우
    • 한국항공우주학회지
    • /
    • 제40권7호
    • /
    • pp.590-600
    • /
    • 2012
  • 본 논문에서는 태양전지나 연료전지와 같은 전기 에너지원을 사용하는 항공기에 적용할 수 있는 일반화된 사이징 방법에 대해 연구를 수행하였다. 다중 추진 시스템이나 에너지원이 사용되는 경우를 고려하여 다중 동력경로를 모델링하였고 소모성 에너지와 비소모성 에너지 중량을 각 임무 단계의 중량변화 계산에 반영하였다. 구속조건의 분석에서 기존의 추력 대 중량비 대신 동력 대 중량비를 선택하여 동력 균형 및 에너지 균형의 사이징 과정에 사용하였다.

분산 재생에너지의 효율적 활용을 위한 가상발전소(VPP) 플랫폼 개발에 관한 연구 (A Development of VPP Platform for the Efficient Utilization of Distributed Renewable Energy Resources)

  • 조영혁;백승엽;최원용;정대율
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제27권2호
    • /
    • pp.95-114
    • /
    • 2018
  • Purpose The recent concern over environmental problems such as greenhouse gas emission and fine dust contributes increasing interest in renewable energies. However the intrinsic characteristics of renewable energies, intermittent and stochastic generation, might cause serious problems to the stability and controllability of power grid. Therefore countermeasures such as virtual power plant (VPP) must be prepared in advance of the spread of uncontrollable distributed renewable energy resources to be one of major energy sources. Design/methodology/approach This study deals with the design concept of the VPP platform. we proposed as a technology solution for achieving the stability of power grid by guaranteeing a single power profile combining multiple distributed power sources with ICT. The core characteristics of VPP should be able to participate in the grid operation by responding to operation instructions from the system operator, KPX, as well as the wholesale electricity market. Findings Therefore this study includes energy storage device(ESS) as a controllable component as well as renewable energy resources such as photovoltaic and wind power generation. Based on this configuration, we discussed core element technologies of VPP and protype design of VPP solution platform according to system requirements. In the proposed solution platform, UX design for the integrated control center and brokerage system were included as well as ancillary service function to respond to KPX's operation instruction with utilizing the capability of ESS. In addition, a simulator was suggested to verify the VPP operations.

웨어러블 서비스를 위한 다중 발전소자 기반 에너지 하베스터 플랫폼 구현 (An multiple energy harvester with an improved Energy Harvesting platform for Self-powered Wearable Device)

  • 박현문;김병수;김동순
    • 한국전자통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.153-162
    • /
    • 2018
  • 웨어러블 디바이스의 서비스 제공을 위한 지속 가능한 전원에 대한 요구가 높아짐에 따라 에너지 하베스팅의 중요성이 증대되고 있다. 본 연구는 마찰소자를 고려한 다중 에너지 하베스팅 플랫폼인 EH-P를 개발하였다. 높은 전압과 낮은 전류를 가진 하베스팅 소자에 전압을 낮추면서 전류를 높일 수 있는 스위치 회로 제시하였다. PV와 TENG의 상호보완적 구성을 통해 실내 환경에서 짧은 시간동안 MCU가 동작할 수 있는 전압과 전류를 제공할 수 있었다. 결과적으로 제안된 플랫폼을 통해 웨어러블 플랫폼을 동작시키고, 제작된 웨어러블 디바이스에서 전체 소모 전력 요구량의 29%를 제공함으로써 웨어러블 디바이스 사용시간(device life time)을 증가시킬 수 있었다. 이 논문에 제시된 결과는 멀티플 하베스터 플랫폼에서 웨어러블 하베스팅 애플리케이션의 활용을 위한 발전 소자의 가능성을 보여주었다.

빌딩 내 최대 풍력발전설비 연계를 위한 소형풍력발전원 구성에 관한 연구 (A Study on Configuration of Small Wind Turbines for Maximum Capacity of Wind Power Systems Interconnected With a Building)

  • 이여진;김성열
    • 전기학회논문지
    • /
    • 제66권4호
    • /
    • pp.605-612
    • /
    • 2017
  • One of the biggest environmental issues that our world has been facing is climate change. In order to cope with such environmental issues, the world is putting a great deal of effort into energy conservation. The building sector, in particular, consumes 36% of the energy consumed worldwide and emits considerable amount of greenhouse gases. Therefore, introduction of renewable energies in the building sector is highly recommended. Renewable energy sources that can be utilized in the building sector include sunlight, solar heat, geothermal heat, fuel cells and wind power. The wind power generation system which converts wind energy into electrical energy has advantages in that wind is an unlimited and pollution-free resource. It is suitable to be connected to existing buildings because many years of operational experience and the enhanced stability of the system have made it possible to downsize the electrical generator. In case of existing buildings, it is necessary to consider the live loads of the buildings to connect the wind power generation system. This paper, through the connection of the wind power generation with existing buildings, promotes reduction of greenhouse gas emissions and energy independence by reducing energy consumption in the building sector. In order to connect the wind power generation system with an exciting building, the live load of the building and the area of the rooftop should be considered. The installable model is selected by comparing the live load of the building and the load of the wind power generation system. The maximum number of the wind turbines that can be installed is obtained by considering the separation distance between the wind turbines within the area of the rooftop. Installations are divided into single installations and multiple installations of two different types of wind turbines. After determining the maximum installable number, the optimal model that can achieve the maximum annual power generation will be selected by comparing the respective total annual amount of the power generation of different models.

Vulnerability Assessment of a Large Sized Power System Using Neural Network Considering Various Feature Extraction Methods

  • Haidar, Ahmed M. A;Mohamed, Azah;Hussian, Aini
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.167-176
    • /
    • 2008
  • Vulnerability assessment of power systems is important so as to determine their ability to continue to provide service in case of any unforeseen catastrophic contingency such as power system component failures, communication system failures, human operator error, and natural calamity. An approach towards the development of on-line power system vulnerability assessment is by means of using an artificial neural network(ANN), which is being used successfully in many areas of power systems because of its ability to handle the fusion of multiple sources of data and information. An important consideration when applying ANN in power system vulnerability assessment is the proper selection and dimension reduction of training features. This paper aims to investigate the effect of using various feature extraction methods on the performance of ANN as well as to evaluate and compare the efficiency of the proposed feature extraction method named as neural network weight extraction. For assessing vulnerability of power systems, a vulnerability index based on power system loss is used and considered as the ANN output. To illustrate the effectiveness of ANN considering various feature extraction methods for vulnerability assessment on a large sized power system, it is verified on the IEEE 300-bus test system.

철도소음의 방사특성에 관한 연구 (A Study on Radiation Characteristic for Railway Noise)

  • 김재철;문경호
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.531-536
    • /
    • 2003
  • In order to control the railway noise. we should know the radiation characteristic of the noise during the train passage Generally, the railway noise sources for conventional trains are classified by the rolling noise and power unit noise in tangent track. In this Paper. we describe on a train model that is considered to be a row of point sources to calculate the radiation characteristic The calculation results are compared with short distance measurement of three kinds of trains (EMU, Mookungwha, Saemaul). It is shown that the radiation characteristic of the rolling noise that is major noise source of electric multiple unit is dipole type. We know that characteristic of the engine noise is radiated as the cosine type.

Performance Analysis for Weaker Channel User in Non-Uniform Source SSC NOMA with Novel BTS

  • Chung, Kyuhyuk
    • International journal of advanced smart convergence
    • /
    • 제11권1호
    • /
    • pp.36-41
    • /
    • 2022
  • Recently, to improve the performance of the strongest channel gain user in non-orthogonal multiple access (NOMA) with a non-uniform source and symmetric superposition coding (SSC), a novel bit-to-symbol (BTS) mapping have been proposed. However, only the performance of the user with the stronger channel gain was analyzed. Thus, we compare the bit-error rate (BER) of the new BTS scheme with that of uniform sources, especially for the user with weakest channel gain. First, we show that the performance of the novel BTS scheme for the user with weakest channel gain also improves, compared to that of the uniform sources. Furthermore, the signal-to-noise (SNR) gain of the new BTS scheme over the uniform sourcesis calculated. As a consequence, the novel BTS scheme would improve the performance of the user with weakest channel gain as well as that with the stronger channel gain for SSC NOMA with a non-uniform source.

오픈 와인딩 머신을 이용한 계통 연계형 분산 발전 시스템의 제어 (Control of an Open Winding Machine in a Grid-Connected Distributed Generation System)

  • 곽무신;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.83-86
    • /
    • 2006
  • A grid-connected distributed generation system which consists of engine generator, dc link with multiple energy sources and inverter is proposed. All six of the stator leads of the generator, which is a surface mount permanent magnet machine, are brought out to the terminal of the generator. Three leads are connected to the inverter and the others are connected to the utility grid. In this proposed system the power from the engine-generator and the power from dc link can be controlled simultaneously by only one three-phase power converter. A control algorithm for the system is developed and verified by experiment results.

  • PDF