• Title/Summary/Keyword: Multiple Units Control

Search Result 110, Processing Time 0.031 seconds

FPGA-based Centralized Controller for Multiple PV Generators Tied to the DC Bus

  • Ahmed, Ashraf;Ganeshkumar, Pradeep;Park, Joung-Hu;Lee, Hojin
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.733-741
    • /
    • 2014
  • The integration of photovoltaic (PV) energy sources into DC grid has gained considerable attention because of its enhanced conversion efficiency with reduced number of power conversion stages. During the integration process, a local control unit is normally included with every power conversion stage of the PV source to accomplish the process of maximum power point tracking. A centralized monitoring and supervisory control unit is required for monitoring, power management, and protection of the entire system. Therefore, we propose a field-programmable gate array (FPGA) based centralized control unit that integrates all local controllers with the centralized monitoring unit. The main focus of this study is on the process of integrating many local control units into a single central unit. In this paper, we present design and optimization procedures for the hardware implementation of FPGA architecture. Furthermore, we propose a transient analysis and control design methodology with consideration of the nonlinear characteristics of the PV source. Hardware experiment results verify the efficiency of the central control unit and controller design.

Modeling and Analysis of the Micro-Grid with SVPWM Micro-Sources (SVPWM 방식 마이크로소스로 구성된 마이크로그리드 모델링 및 해석)

  • Son, Kwang-Myung;Lee, Kye-Byung;Kim, Young-Seob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.12-19
    • /
    • 2006
  • Micro-source units having power ratings in thousands of watts can provide power quality with higher reliability and efficiency than the conventional large scale units. This paper develops switching level model of micro-source and studies the characteristics of the micro-grid consisting of multiple micro-sources and interfaced with electric power system. The developed model adopts the space vector PWM to fully utilize the capacity of inverter. The interaction of the grid connected micro-sources and the characteristics of the control system parameters are investigated. Micro-sources and micro-grid are implemented using PSCAD/EMTDC. Simulation results show that the proposed model is efficient for studying micro-grid system.

Design of a bluetooth-based interactive control network

  • Kwak, Jae-Hyuk;Lim, Joon-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.922-925
    • /
    • 2004
  • Bluetooth technology is essentially a method for wireless connection of a diverse set of devices ranging from PDAs, mobile phone, notebook computers, to another equipments. The bluetooth system supports both point-to-point connection and point-to-multipoint connections. In point-to-multipoint connection, the channel is shared among several bluetooth devices. Two or more devices sharing the same channel form a piconet. There is one master device and up to seven active slave devices in a piconet. The radio operates in the unlicensed 2.45GHz ISM band. This allows users who travel world-wide to use bluetooth equipments anywhere. Since the link is based on frequency-hop spread spectrum, multiple channels can exist at the same time. The Bluetooth standard has been suggested that Bluetooth equipments can be used in the short-range, maximum 100 meters . It has been defined that the time takes to setup and establish a bluetooth connection among devices is 10 seconds. It is a long time and may be a cause to lose a chance of finding other non-fixed devices. We propose a routing protocols for scatternets which can be used to control a mobile units(MUs) in this network. The proposed routing protocol is composed of two kinds of bluetooth information, access point(AP) and MU.

  • PDF

Factors affecting satisfaction in National Cancer Screening Program (국가암조기검진 수검자 만족도에 영향을 미치는 요인)

  • Yoon, Nan-He;Kwon, Soon-Man;Lee, Hoo-Yeon;Park, Eun-Cheol;Choi, Kui-Son;Kwak, Min-Son
    • Health Policy and Management
    • /
    • v.19 no.1
    • /
    • pp.31-48
    • /
    • 2009
  • The objectives of this study were to evaluate the satisfaction of participants in the National Cancer Screening Program(NCSP) and to identify factors affecting the satisfaction. The telephone survey was conducted in July 2007 for the participants who were screened by the NCSP from January through May 2007. Student's t-tests and analysis of variance were performed first to determine if the mean satisfaction score differed by the characteristics of study objects, followed by multiple linear regression analyses to examine the factors affecting satisfaction. Dependent variable was general satisfaction for the screening service, and three dimensions of independent variables - 'sociodemographic characteristics', 'screening characteristics', and 'perceived service quality' - were used for the empirical analyses. Female, old-aged, less educated, Medicaid recipients, rural residents and the participants with normal results were more likely to be satisfied with the NCSP. The results of multiple regression analyses show that gender, age, location of residence, type of screening units, and perceived quality of screening services were significantly related to satisfaction. This study is meaningful as the first attempt to measure participant satisfaction with the NCSP, and to identify factors affecting the satisfaction. Among the identified factors, the NCSP needs to pay attention to perceived quality of service, in particular, to improve the satisfaction. This study is expected to contribute to raising the compliance rate and to improve the quality of the NCSP.

Optimal Design of Process-Inventory Network Considering Exchange Rates and Taxes in Multinational Corporations (다국적 기업에서 환율과 세금을 고려한 공정-저장조 망구조의 최적설계)

  • Yi, Gyeong-Beom;Suh, Kuen-Hack
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.9
    • /
    • pp.932-940
    • /
    • 2011
  • This paper presents an integrated analysis of supply chain and financing decisions of multi-national corporation. We construct a model in which multiple currency storage units are installed to manage the currency flows associated with multi-national supply chain activities such as raw material procurement, process operation, inventory control, transportation and finished product sales. Core contribution of this study is to quantitatively investigate the influence of macroscopic economic factors such as exchange rates and taxes on operational decisions. The supply chain is modeled by the Process-Storage Network with recycle streams. The objective function of the optimization is minimizing the opportunity costs of annualized capital investments and currency/material inventories minus the benefit to stockholders interpreted by home currency. The major constraints of the optimization are that the material and currency storage units must not be depleted. A production and inventory analysis formulation, the periodic square wave (PSW) model, provides useful expressions for the upper/lower bounds and average levels of the currency and material inventory holdups. The expressions for the Kuhn-Tucker conditions of the optimization problem are reduced to a subproblem and analytical lot sizing equations. The procurement, production, transportation and financial transaction lot sizes can be determined by analytical expressions after the average flow rates are already known. We show that, when corporate income tax is taken into consideration, the optimal production lot and storage sizes are smaller than is the case when such factors are not considered typically by 20 %.

Triggers and Outcomes of Falls in Hematology Patients: Analysis of Electronic Health Records (혈액내과 입원 환자의 낙상 위험 요인과 환자 결과: 전자의무기록 분석)

  • Jung, Min Kyung;Lee, Sun-Mi
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.26 no.1
    • /
    • pp.1-11
    • /
    • 2019
  • Purpose: The goal was to use electronic health records to identify factors and outcomes associated with falls among patients admitted to hematology units. Methods: This retrospective case-control study included data from a tertiary university hospital. Analysis was done of records from 117 patients with a history of falls and 201 patients with no history of falls who were admitted to the hematology unit from January 1, 2013 to December 31, 2014. Risk factors were analyzed using hierarchical logistic regression; patient outcomes were analyzed using multiple logistic regression, Cox proportional hazards regression, and multiple linear regression. Results: Clinical factors such as self-care nursing (OR=4.47, CI=1.64~12.11), leukopenia (OR=6.03; CI=2.51~14.50), and hypoalbuminemia (OR=2.79, CI=1.31~5.96); treatment factors such as use of narcotics (OR=2.06, CI=1.01~4.19), antipsychotics (OR=3.05, CI=1.20~7.75), and steroids (OR=4.51, CI=1.92~10.58); and patient factors such as low education (OR=3.16, CI=1.44~6.94) were significant risk factors. Falls were also associated with increased length of hospital stay to 21.58 days (p<.001), and healthcare costs of 17,052,784 Won (p<.001). Conclusion: These findings can be a resource for fall prevention education and to help develop fall risk assessment tools for adults admitted to hematology units.

Bluetooth Network for Mobile System Control (이동 시스템 제어를 위한 블루투스 네트워크)

  • 임준홍;곽재혁
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.11
    • /
    • pp.1052-1057
    • /
    • 2004
  • Bluetooth technology is essentially a method for wireless connectivity of a diverse set of devices ranging from PDAs, mobile phone, notebook computers, to another equipments, The bluetooth system both point-to point connection and point-to multipoint connection. In point-to multipoint connection, the channel is shared among several bluetooth devices. Two or more devices sharing the same channel form a piconet. There one master device and up to seven active slave devices in a piconet. The radio operates in the unlicensed 2.45GHz ISM band. This allows users who travel world-wide to use bluetooth equipments anywhere. Since the link is based on frequency-hop spread spectrum, multiple channels can exist at the same time. The bluetooth standard ha s been suggested that bluetooth equipments can be used in the short-range, maximum 100 meters. It has been defined that the time takes to setup and establish a bluetooth connection among devices is 10 seconds. It is a long time and may be a cause to lose a chance of finding other non-fixed devices. We propose a routing protocols for scatternets which can be used to control a mobile units(MUs) in this network. The proposed routing protocol is composed of two kinds of bluetooth information, access point(AP) and MU.

Analysis of Cascaded H-Bridge Multilevel Inverter in DTC-SVM Induction Motor Drive for FCEV

  • Gholinezhad, Javad;Noroozian, Reza
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.304-315
    • /
    • 2013
  • In this paper, analysis of cascaded H-bridge multilevel inverter in DTC-SVM (Direct Torque Control-Space Vector Modulation) based induction motor drive for FCEV (Fuel Cell Electric Vehicle) is presented. Cascaded H-bridge multilevel inverter uses multiple series units of H-bridge power cells to achieve medium-voltage operation and low harmonic distortion. In FCEV, a fuel cell stack is used as the major source of electric power moreover the battery and/or ultra-capacitor is used to assist the fuel cell. These sources are suitable for utilizing in cascaded H-bridge multilevel inverter. The drive control strategy is based on DTC-SVM technique. In this scheme, first, stator voltage vector is calculated and then realized by SVM method. Contribution of multilevel inverter to the DTC-SVM scheme is led to achieve high performance motor drive. Simulations are carried out in Matlab-Simulink. Five-level and nine-level inverters are applied in 3hp FCEV induction motor drive for analysis the multilevel inverter. Each H-bridge is implemented using one fuel cell and battery. Good dynamic control and low ripple in the torque and the flux as well as distortion decrease in voltage and current profiles, demonstrate the great performance of multilevel inverter in DTC-SVM induction motor drive for vehicle application.

Module UPS of multi-parallel operation for use in information & telecommunication systems (정보통신용 다병렬 운전의 모듈식 무정전전원장치)

  • Koo, Tae-Geun;Ryu, Ji-Su;Bae, Sang-Gyu;Park, Keun-Kap
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.390-393
    • /
    • 2007
  • The reliability as well as the power capability of the UPS system can be increased by replacing a single UPS unit with multiple small UPS units in parallel, resulting in a so-called module UPS. This module UPS system allows that a new module can be added or replaced while maintaining power to loads, which is a hot-swappable operation. In addition, it has desirable features such as ease of output power expandability, convenience of maintenance and repair, and high reliability. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. 5kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the module UPS system has a high power factor, a low distortion of output voltage and input current, hot-swappable operations and good load sharing characteristics.

  • PDF

Improved Design in Fishing Operation System for Small Inshore and Coastal Fishing Vessels -II -Design of a Remote Steering System- (소형 연근해 어선의 조업 시스템 개선에 관한 연구-II -원격 조타 시스템의 설계-)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.1
    • /
    • pp.25-32
    • /
    • 2000
  • A combination steering system was designed to provide the flexibility in controlling the steering wheel in fishing operations of the inshore and coastal fishing vessels. The designed steering system basically is consisted of three driving units, such as a electrically driven hydraulic pump unit with a solenoid control valve, a DC motor driven hydraulic pump unit and a manually driven hydraulic pump unit, and two controllers to provide remote steering on the deck, respectively. The steering torque was measured and analyzed to investigate the dynamic performance of the developed steering system. The steering system showed excellent linearity between the working pressure of cylinder and the torque of rudder post in case of increasing in rudder angle from $5^{\circ} to 35^{\circ}$ that is, the steering torque increased from $10.4 kgf{\cdot}m$ to $105.3 kgf{\cdot}m$ and then the working pressure of cylinder fluctuated from 6.3 kgf/cm super(2) to 16.4 kgf/cm super(2). The steering time of 3.2 sec in remote hydraulic steering by the on/off solenoid valve control was much faster than 13.2 sec in the manual steering by the helmsman and 11.6 sec in the electric steering by a DC motor, and then it was verified that operation of one unit does not affect other units in combination steering system in any way. Furthermore, the developed steering system can be remotely controlled in multiple stations of the deck during the fishing operation and the automatic pilot steering unit can be used to add hydraulic steering.

  • PDF