• Title/Summary/Keyword: Multiple Defect

Search Result 267, Processing Time 0.025 seconds

Soft tissue reconstruction in wide Tessier number 3 cleft using the straight-line advanced release technique

  • Kim, Gyeong Hoe;Baek, Rong Min;Kim, Baek Kyu
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.4
    • /
    • pp.255-259
    • /
    • 2019
  • Craniofacial cleft is a rare disease, and has multiple variations with a wide spectrum of severity. Among several classification systems of craniofacial clefts, the Tessier classification is the most widely used because of its simplicity and treatment-oriented approach. We report the case of a Tessier number 3 cleft with wide soft tissue and skeletal defect that resulted in direct communication among the orbital, maxillary sinus, nasal, and oral cavities. We performed soft tissue reconstruction using the straight-line advanced release technique that was devised for unilateral cleft lip repair. The extension of the lateral mucosal and medial mucosal flaps, the turn over flap from the outward turning lower eyelid, and wide dissection around the orbicularis oris muscle enabled successful soft tissue reconstruction without complications. Through this case, we have proved that the straight-line advanced release technique can be applied to severe craniofacial cleft repair as well as unilateral cleft lip repair.

Long V-Y advancement technique for large nipple reconstruction in Asian women

  • Jang, Nam;Kim, Junekyu;Shin, Hyun Woo;Suk, Sang Woo
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.44-48
    • /
    • 2021
  • Previously reported nipple-areolar complex reconstruction (NAR) methods involve multiple incisions and wide skin redraping, which increase retraction forces and heighten the risk of nipple-areolar complex (NAC) flattening. We introduce a NAR method using the long V-Y advancement technique that can overcome these disadvantages. A V-shaped flap is designed with the width of the flap base 4-5 mm larger than the diameter of the normal nipple. The flap length is designed to be at least 2.5 times its width. Dissection is performed to the top of the artificial dermal matrix or muscle layer. The nipple is constructed with the same projection as the contralateral side by folding the elevated flap. The tip of the elevated flap is apposed in the middle of the donor defect to minimize the deformity during donor site closure. A 3-point skin suture is applied to the upper third of the folded flap to mold its shape. Using this long V-Y advancement technique, we successfully decreased skin tension in NAC flaps and improved the maintenance of reconstructed nipple projection. The long V-Y advancement technique provides an easy, simple NAR method, effectively maintaining longer nipple projections and reducing breast deformities, especially in Asian women with relatively large nipples.

Cross-Leg Free Flap: Crossing the Border Zone of Ischemic Limb-A Case Report of Limb Salvage Procedure following a Delayed Diagnosis of Popliteal Artery Injury

  • Hui Yuan Lam;Wan Azman Wan Sulaiman;Wan Faisham Wan Ismail;Ahmad Sukari Halim
    • Archives of Plastic Surgery
    • /
    • v.50 no.2
    • /
    • pp.188-193
    • /
    • 2023
  • Vascular injury following traumatic knee injury quoted in the literature ranges from 3.3 to 65%, depending on the magnitude and pattern of the injury. Timely recognition is crucial to ensure the revascularization is done within 6 to 8 hours from the time of injury to avoid significant morbidity, amputation, and medicolegal ramifications. We present a case of an ischemic limb following delayed diagnosis of popliteal artery injury after knee dislocation. Even though we have successfully repaired the popliteal artery, the evolving ischemia over the distal limb poses a reconstruction challenge. Multiple surgical debridement procedures were performed to control the local tissue infection. Free tissue transfer with chimeric latissimus dorsi flap was done to resurface the defect. However, the forefoot became gangrenous despite a free muscle flap transfer. His limb appeared destined for amputation in the vicinity of tissue and recipient vessels, but we chose to use a cross-leg free flap as an option for limb salvage.

Combined Treatment of Stromal Vascular Fraction and Ablative Fractional CO2 Laser for Hypertrophic Foot Scar

  • Kim, Dong Gyu;Park, Eun Soo;Kim, Seok Hwan
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.90-93
    • /
    • 2019
  • The treatment of keloid and hypertrophic scars (HTSs) remains one of the most difficult challenges, with a high recurrence rate regardless of the method of treatment. The latest trend in scar management is a combined approach using multiple modalities that are individualized to the patient and that would provide successful results for keloid and HTSs. There are previous reports that stromal vascular fraction (SVF) is effective for scar remodeling. Based on these reports, we introduced the concept of a combination treatment using SVF injection and fractional ablative CO2 laser. In this report, we present a 21-year-old woman who was involved in a car accident. A defect on her foot was covered with a skin graft, but the scars became elevated, which turned out to be HTSs. She was treated with a fractional ablative CO2 laser for five sessions. A month later, SVF injection and fractional ablative CO2 laser were conducted simultaneously. The result of a year's follow-up showed a flattened scar with resolution of pigment deposition. In conclusion, the combination treatment for HTSs with SVF injection and ablative fractional CO2 laser is one of the modalities to achieve an excellent outcome for treating HTS.

Evaluation of the Adhesion Stability According to the Backfilling Area of the Tile back of the Bathroom of an Apartment House (공동주택 욕실의 타일배면 뒤채움 피착면적에 따른 부착안정성 평가)

  • Kim, Bum Soo;Song, Je Young;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.14-15
    • /
    • 2021
  • Recently, the size of tiles used for bathroom walls in apartment houses is gradually increasing in size. The problem is that when these large-sized tiles are attached by the sticking method, due to the nature of the method, there is a concern about the stability of the attachment to the part (pupil) where the tile and the adhesive are not attached. The problem is serious as it leads to lawsuits in the outbreak court. In addition, it is urgent to verify the adhesion stability of the sticking method because secondary damage occurs due to a safety accident caused by the falling of the tile. Ministry of Land, Infrastructure and Transport [Investigation of defects in apartment houses, calculation of repair cost and defect determination criteria] ① The tile adhesion strength is 0.39N/mm2 or more and ② It is specified to fill 80% or more of the base area of the tile backside, but this is currently trendy. It is considered that large-sized tiles need to be verified from multiple angles, and as part of that, we intend to verify the adhesion stability according to the area to be attached to large-sized tiles.

  • PDF

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Effect of Annealing Temperature on the Luminescence Properties of Digital-Alloy InGaAlAs Multiple Quantum Wells (디지털 합금 InGaAlAs 다중 양자 우물의 열처리 온도에 따른 발광 특성)

  • Cho, Il Wook;Byun, Hye Ryoung;Ryu, Mee-Yi;Song, Jin Dong
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.6
    • /
    • pp.321-326
    • /
    • 2013
  • The effect of rapid thermal annealing (RTA) on the optical properties of digital-alloy InGaAlAs multiple quantum well (MQW) structures have been investigated by using photoluminescence (PL) and time-resolved PL measurements as a function of RTA temperature. The MQW samples were annealed from $700^{\circ}C$ to $850^{\circ}C$ for 30 s in a nitrogen atmosphere. The MQW sample annealed at $750^{\circ}C$ exhibited the strongest PL intensity and the narrowest FWHM (Full width at half maximum), indicating the reduced nonradiative recombination centers and the improved interfaces between the wells and barriers. The MQW samples annealed at $800^{\circ}C$ and $850^{\circ}C$ showed the decreased PL intensities and blueshifted PL peaks compared to $750^{\circ}C$-annealed sample. The blueshift of PL peak with increasing RTA temperatures are ascribed to the increase of aluminum due to intermixing of gallium (Ga) and aluminum (Al) in the interfaces of InGaAs/InAlAs short-period superlattices. The decrease of PL intensity after annealing at $800^{\circ}C$ and $850^{\circ}C$ are attributed to the interface roughening and lateral composition modulation caused by the interdiffusion of Ga and Al and indium segregation, respectively. With increasing RTA temperature the PL decay becomes slower, indicating the decrease of nonradiative defect centers. The optical properties of digital-alloy InGaAlAs MQW structures can be improved significantly with optimum RTA conditions.

Revisit of the Extended Indications and Clinical Utilities of Arterialized Venous Flap for Hand Reconstruction (수부 재건을 위한 동맥화 정맥 피판의 확장된 적응증과 임상적 유용성의 재조명)

  • Woo, Sang-Hyun;Kim, Kyung-Chul;Lee, Gi-Jun;Ha, Seung-Han;You, Sun-O;Kim, Joo-Sung
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.1-13
    • /
    • 2005
  • Purpose: The purpose of this study is to present extended indications for the use of arterialized venous flaps in reconstructing soft tissue, tendon, nerve, blood vessel, and composite tissue defects of the hand of various sizes based on researches and clinical experiences of the authors. Moreover, procedures to achieve complete flap survival and postoperative results are presented. Materials & methods: This study is based on 154 cases of arterialized venous flaps performed to reconstruct the hand during the past 11 years. The most common cause of injury was industrial accidents with 125 cases. One hundred thirty patients or 84% of the cases had emergency operation within 2 weeks of the injury. The flaps were categorized depending on the size of the flap. Flaps smaller than $10\;cm^2$ were classified as small (n=48), those larger than $25\;cm^2$ classified large (n=42) and those in between medium (n=64). Classified according to composition, there were 88 cases (57.1 %) of venous skin flaps, 28 cases of innervated venous flaps, 15 cases of tendocutaneous venous flaps, which incorporated the palmaris longus tendon, for repair of extensor tendons of the fingers, and 17 cases of conduit venous flaps to repair arterial defect. There were 37 cases where multiple injuries to multiple digits were reconstructed. Moreover, there were 6 cases of composite tissue effects that involved soft tissue, blood vessels and tendons. The donor sites were ipsilateral forearm, wrist and thenar area, foot dorsum, and medial calf. The recipient sites were single digit, multiple digits, first web space, dorsum and palm of hand, and wrist. Results: There were seven cases (4.5%) of emergent re-exploration due to vascular crisis, and 3 cases of flap failure characterized by more than 50% necrosis of the flap. The survival rate was 98.1 % (151/154). In small flaps, an average of 1.01 afferent arteries and 1.05 efferent veins were microanastomosed, and in large flaps, an average of 1.88 afferent arteries and 2.19 efferent veins were anastomosed. In 8 cases where innervated flaps were used for reconstructing the palm of the hand, the average static two-point discrimination was $10\;(8{\sim}15)\;mm$. In 12 cases where tenocutaneous flaps were used, active range of motion at the proximal interphalangeal joint was 60 degrees, 20 degrees at the distal interphalangeal joint, and 75 degrees at the metacarpophalangeal joint. Conclusion: We conclude that the arterialized venous flap is a valuable and effective tool in the reconstruction of hand injuries, and could have a more comprehensive set of indications.

  • PDF

Bone Marrow Scintigraphy with Antigranulocyte Antibody in Multiple Myeloma: Comparison with Simple Radiography and Bone Scintigraphy (항과립구 항체 골수스캔을 이용한 다발성 골수종 병변의 평가: 단순골X-선점사 및 골스캔과의 비교)

  • Kim, Dong-Hwan;Lee, Jae-Tae;Baek, Jin-Ho;Jung, Jin-Tae;Hyun, Dong-Woo;Chun, Kyung-Ah;Lee, Young-Hak;Sohn, Sang-Kyun;Song, Hong-Seok;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.354-364
    • /
    • 1998
  • Purpose: Simple X-ray study and bone scan have limitations for early diagnosis of bone or bone marrow lesions in multiple myeloma. The purpose of this study was to evaluate the diagnostic usefulness of bone marrow immunoscintigraphy using anti-granulocyte monoclonal antibody for the evaluation of bone involvement in multiple myeloma. Materials and Methods: In 22 patients (Male: 15, Female: 7) with multiple myeloma, we performed whole-body immunoscintigraphy using $^{99m}Tc$-labelled antigranulocyte antibody (BW 250/183, Scintimum $Granulozyt^{(R)}$ CIS, France) and compared the findings with those of simple bone radiography and $^{99m}Tc$-MDP bone scan. Abnormal findings in bone marrow scintigraphy were, considered to be present in case of expansion of peripheral bone marrow or focal photon defect in axial bones. Results: Marrow expansion was noted in 15 of 22 patients (68%). Focal photon defects were found in 18 patients (82%). While one (33%) of 3 patients with Stage II disease showed focal defects in bone marrow scan, abnormal focal defects were observed in 17 of 19 (90%) patients with Stage III. Among 124 focal abnormal sites which were observed in bone marrow scan, bone scan or simple bone radiography, bone marrow scan detected 92 sites (74%), whereas 82 sites (66%) were observed in simple bone radiography(58 sites, 47%) or bone scan(40 sites, 32%). Fifty-one (41%) out of 124 bone lesions were detected by bone marrow scan only, and located mostly in thoracolumbar spine. Conclusion: Bone marrow scan using $^{99m}Tc$-labelled antigranulocyte antibody seems to be a more sensitive procedure for the detection of pathologic bone lesions than simple bone X-ray or bone scan in patients with multiple myeloma.

  • PDF

Triple Detector SPECT Imaging with $^{99m}Tc-DMSA$ in Adult Patients with Urinary Tract Infection (성인 요로 감염 환자에서 $^{99m}Tc-DMSA$ 삼중검출기 SPECT 영상의 유용성)

  • Ryu Jin-Sook;Bae, Won-Gyu;Moon Dae-Hyuk;Lee, Myung-Hae;Kim, Soon-Bae,;Park, Su-Kil;Park, Jung-Sik;Hong, Chang-Gi D.;Cho, Kyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.290-298
    • /
    • 1992
  • Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head $^{99m}Tc-DMSA$ SPECT imaging in urinary tract infection. We prospectively performed $^{99m}Tc-DMSA$ planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), $^{99m}Tc-DMSA$ SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of $^{99m}Tc-DMSA$ SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radioligic studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on $^{99m}Tc-DMSA$ SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on $^{99m}Tc-DMSA$ SPECT imaging. Follow-up $^{99m}Tc-DMSA$ SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) $^{99m}Tc-DMSA$ SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. $^{99m}Tc-DMSA$ SPECT is useful as a initial diagnostic tool in adult patients with urinary tract infection. 2) The multiple RCD on $^{99m}Tc-DMSA$ SPECT represent the high probability of irreversible tissue change and need of extensive urological work-up.

  • PDF